Tilt Aggregation Procedure for Kathrein PCA
1
This procedure requires PCA v2.3.3 software on the computer.
Begin by launching the PCA software and connecting to the FlexRET module.
Click Start Scan and Connect.
After the scan is done, you will see the current configuration. The antenna type in
this example is 80010892V01. Your type may differ.
Click Software Update.
Tilt Aggregation Procedure for Kathrein PCA
2
If the Software Update screen shows 86010153V01 under Product Number and FW_V02.02.00 under
Software Version, proceed directly to the aggregation process on page 9. If not, the firmware on the
FlexRET MUST be updated, or the aggregation files cannot be loaded. For this procedure, continue to
the next page.
Tilt Aggregation Procedure for Kathrein PCA
3
On this screen, click Select. Any one of the RET numbers can be used for this
process.
Tilt Aggregation Procedure for Kathrein PCA
4
Browse to the location of the files you received, select the file named
86010153_FRET_FW_V02-02-00 and click Open.
Tilt Aggregation Procedure for Kathrein PCA
5
Click Start.
Tilt Aggregation Procedure for Kathrein PCA
6
You will see a typical progress bar. It will take a few minutes.
Tilt Aggregation Procedure for Kathrein PCA
7
When it is done, the Finish button will be enabled and you can click it.
Tilt Aggregation Procedure for Kathrein PCA
8
The Device Status screen will reappear. Click Software Update.
Tilt Aggregation Procedure for Kathrein PCA
9
Note the Software Version is now V02.02.00 on all the RETs. The product number
will not change if you have just updated the firmware.
Click Select on any of the RETs.
Tilt Aggregation Procedure for Kathrein PCA
10
Browse to the location of the files you received and select the antenna type you
are using. Note that your antenna type may vary. Click Open.
Tilt Aggregation Procedure for Kathrein PCA
11
Click Start.
Tilt Aggregation Procedure for Kathrein PCA
12
This file loads quickly and you will not see a progress bar. Click Finish.
Tilt Aggregation Procedure for Kathrein PCA
13
Note that the RETs to be aggregated are in ERROR. That is because they no longer
exist and have been replaced by aggregated RETs.
Click the Device Status button to return to the main screen.
Tilt Aggregation Procedure for Kathrein PCA
14
Click Yes to go to the opening screen.
Tilt Aggregation Procedure for Kathrein PCA
15
Click Start Scan and Connect.
Tilt Aggregation Procedure for Kathrein PCA
16
Note that the newly aggregated RETs have appeared. Note the new Serial
Numbers with the descriptive suffixes.
The ERROR messages indicate the they must be calibrated. Click the Details
button on the first one.
Tilt Aggregation Procedure for Kathrein PCA
17
Note the NOT_CALIBRATED Status. Click Calibrate.
Tilt Aggregation Procedure for Kathrein PCA
18
This takes several seconds while the aggregated RET is calibrated.
The Status is MOVING during this process.
Tilt Aggregation Procedure for Kathrein PCA
19
When it is done, the Status will be OK. Click Back to Device Status.
Tilt Aggregation Procedure for Kathrein PCA
20
Calibrate the remaining aggregated RET in the same manner as before.
Tilt Aggregation Procedure for Kathrein PCA
21
Click Calibrate.
Tilt Aggregation Procedure for Kathrein PCA
22
Note the OK Status message.
Tilt Aggregation Procedure for Kathrein PCA
23
Click Back to Device Status to confirm proper configuration and Status.