72
This slide is used for start page and chaptering. Insert your image here (The image should cover the whole grey square by doing that you automatically follow the new graphic manual) Rumsakustik Erling Nilsson, Akustiker ECOPHON Saint-Gobain

This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Embed Size (px)

Citation preview

Page 1: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

This slide is used for start page and chaptering.

Insert your image here(The image should cover the whole grey square by doing that you automatically follow the new graphic manual)

RumsakustikErling Nilsson, AkustikerECOPHON Saint-Gobain

Page 2: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Community school no 15, Gdynia, Poland. Architect: Adam Drochomiercki. Photo: Szymon Polanski.System: Ecophon Master A/alpha

Page 3: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Hospital Spital św. Zofii, Warsaw, Poland. System: Ecophon Hygiene A dvance

Page 4: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Axel Springer AG, Hamburg, Germany. Photo: Eric Sha mbroom. System: Ecophon Light coffer with Focus E .

Page 5: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Restaurang Restaurangen, Stockholm. Architect: Matt ias Ljunggren. Photo: Åke E:son Lindman. System: Focus D with Connect Shadow channel trim

Page 6: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

• SWIMMINGPOOL

Miejska Sala Widowiskowo-Sportowo, Community Sports Hall. Architect: Przedsibiorstwo Projektowo-Wykona wcze pro-Art KONOPKA. Photo: Szymon Polanski. System: Ec ophon Focus DG

Page 7: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Sultan Ahmad State Mosque, Kuantan, Malaysia. Syste m: Ecophon Gedina.

Page 8: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Örat

Page 9: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Hörselsnäckan

Page 10: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Hair cells in cochlea: a) In healthy conditions

b) With ongoing damage by noise, gluing together.

c) With ongoing damage by noise, loss of stiffness.

d) Complete degeneration, hair cells broken off.

Skador på hårcellerna i örat

Page 11: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Hörseltest

Page 12: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Did you .eethe .portmaga.inelast .aturday?

Audiogram

Page 13: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Normal hörsel

Page 14: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Hörselskada

Page 15: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Kerstin Persson Waye, Occupational and Environmental Medicine, Gothenburg University

Gränsvärden för att undvika hörselskador• 75 dB LAeq 8 timmar – anses som en riskfri nivå

• 85 dB LAeq 8 timmar, riktvärde i många länder

• 130-150 dB peak – ökad risk för hörselskada

Page 16: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Kerstin Persson Waye, Occupational and Environmental MedicineGothenburg University

� annoyance, disturbance

Effects in the occupational environment due to noise

� performance and learning

� speech interference

� tiredness

� lower job satisfaction

� social interaction

� hearing impairment, tinnitus

Page 17: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Wallace Clement Sabine(June 13, 1868 – January 10, 1919)

American physicist who founded the field of architectural acoustics

Page 18: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Definition: Reverberation time

Sound pressure level, dB

Time, seconds

60 dB

T60

Page 19: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

His formula

where

T=the reverberation time (s)V=the room volume (m3)A=the total equivalent absorption area (m2 sabin)

where

=A

VT 16.0

=TV

A 16.0or

The equivalent absorption area A for a surface with area S m2

is equal to α x S where α is the absorption coefficient for the surface

Page 20: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Standards and regulations

Page 21: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Absorption coefficient at normal incidence

AbsorberIncident sound energy

Reflected sound energy

Absorbed sound energy

������������ ����� � = �������������������

�������������������

Page 22: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Impedance tube (Kundt’s tube)

Lmax (dB)

Lmin (dB)

� = 10(#$%&'#$())/,-

� =4�

(1 + �),

Absorber

Page 23: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Absorption coefficient

AbsorberIncident sound energy at angle θ

θ

θ

Reflected sound energy at angle θ

Absorbed sound energy at angle θ

������������ ����� �(0) = �������������������1�1��2�3

�������������������1�1��2�3

Page 24: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Reflected sound

0,30 – 0,55 (class D) 1-4 dB0,60 – 0,75 (class C) 4-7 dB0,80 – 0,85 (class B) 7-10 dB0,90 – 0,99 (class A) 10-20 dB

The reflected sound is reduced by

Absorption coefficient

)1log(10 α−⋅=∆ L

LincidenceLreflected ∆L = Lincidence- Lreflected (dB)

Page 25: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Glass wool

Page 26: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Open and closed structures

Closed cell Open cell Simple model of porous absorber

Page 27: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Microscopic structure

Page 28: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Friction

Page 29: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Acoustic design with Sabine formula

� A(before treatment)=0,161xV/T= 0,161x200/2,5=12,9 m2 sabin

� A(needed to fulfil 0,40 s)= 0,161xV/T=0,161x200/0,40=80,5 m2 sabin

� A( to be added to fulfil 0,40 s)=A(needed)-A(before)=80,5-12,9=67,6 m2 sabin

Example: The reverberation time in a room with a volume of 200 m3

is 2,5 s at 1000 Hz. Target value for the reverberation time is 0,40 s at 1000 Hz

If e.g. the absorption coefficient for a ceiling absorber is 0,90 at 1000 Hzwe will need S= A/α=67,6/0,90=75 m2

Page 30: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Sabine formula: How it works in theory

Absorption coefficients (500 Hz):

Walls=0,15Ceiling=0,80Floor=0,10

Page 31: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Absorption data from EN 12354-6

Page 32: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Absorption data from EN 12354-6

Page 33: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Sabine formula: How it works in theory

Absorption coefficients (500 Hz):

Walls=0,15Ceiling=0,80Floor=0,10

A=∑αi x Si = 0,10x6x7,5+2x0,15x7,5x2,5+2x0,15x6x2,5+0,80x6x7,5=51 m2 sabin

T60=0,161x(V/A)=0,161x112,5/51≈0,36 s

Page 34: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Not a typical classroom

Page 35: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Reverberation decay in rooms with suspended absorbent ceiling

T20

Increased diffusivity

Page 36: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

On the use of practical absorption coefficients

Page 37: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

On the use of practical absorption coefficients

Page 38: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

S,

VA=equivalent absorption area, m2 sabine

V= room volyme, m3

T= reverberation time, s

absorption coefficient

α = ∆A/S

Measurement of absorption coefficients according to EN ISO 354

α

withoutTV

withTVAAA

withoutwith⋅−⋅=−=∆ 16.016.0

Page 39: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

FHU - Acoustic specification

S

A=α

Equivalent absorption area (ISO 354)

A (m2)

Absorption factor (ISO 354)

S ?

Absorbent ceiling FHU – free hanging unit

Page 40: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

V

Reverberation chamber

)11(16.0withoutTwithT

VA −=

AFHU =A/6

Free hanging units “Solo”

Page 41: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Typical classroom

Page 42: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Effect of furniture

absorption

scattering

Page 43: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

No boxes

Boxes on the wall

Sabine

Scattering – why is it important?

Glass wool

Page 44: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Reflection from a surface

Specular reflection

–Angle of reflection equals

angle of incidenceθ

θ

Incident sound energy, Iinc

Reflected sound energy, Irefl

Absorption coefficient:

� = 4��� − 4��62

4���=

41��

4���

Page 45: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Reflection from a surface

Specular reflection

–Angle of reflection equals

angle of incidence

Diffuse reflection

–Scattered in many

directions

Page 46: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Reflection from a surface

Scattering coefficient, s

• Fraction of energy which is scattered

• Always between 0 and 1

Page 47: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Absorption and scattering

� + 1 − � ∙ 1 − � + 1 − � ∙ � = 1

absorbed specularly reflected diffusely reflected

Page 48: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Simulation of sound fields

Page 49: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

This slide is used for start page and chaptering.

Insert your image here(The image should cover the whole grey square by doing that you automatically follow the new graphic manual)

Room Acoustic Comfort

Page 50: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Assessment of sound in rooms

Page 51: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Room types

Reverberant room

(Sabine room)

Open-plan spaces

Corridors

Room with absorbent

ceiling

Page 52: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

An approach to create room acoustic comfort

Sensation of soundSeveral room acoustical descriptors

Characterisation of room types

Room acoustic requirements adapted for the activity

People Room

Activity

Reverberance: EDT, T20, T30

Speech inelligibility: C50, STI

Strength of sound: G, SPL

Sound propagation: DL2, DLf

Reverberant rooms

industrial spaces,

central stations,

cathedrals

Ordinary rooms with absorbent ceilings

class rooms,

offices,

health care premises

dining rooms,

conference rooms,

day-care centres

Rooms with extended forms

open-plan offices,

corridors

Education

Machinery noise

Noisy activities

Office sounds

Music

Page 53: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Room acoustic quality aspects• Reverberation• Speech clarity• Auditory strength• Spatial decay

Page 54: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Efterklang

• Relaterar till hur snabbt ljudenergin försvinner i ett rum

Lång efterklang

Kort efterklang

Page 55: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Taltydlighet

• Relaterar till hur tydligt tal uppfattas

Otydligt

Tydligt

Page 56: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Ljudstyrka

• Upplevelsen av ljudets styrka

Hög ljudnivå

Låg ljudnivå

Page 57: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Ljudets avståndsdämpning

• Ljudnivån avtar med avståndet från ljudkällan.

Tal på 1 meters avstånd

Tal på 4 meters avstånd

Tal på 8 meters avstånd

Page 58: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Reverberation

Speech Clarity

Auditory Strength

Spatial decay

Early Decay Time (EDT), T20, T30 (ISO 3382-1/2)

C50 , U50, STI (ISO 3382-1, IEC 60268-16)

Sound Strength G (ISO 3382-1)

D2,S , Lp,A,S,4m , STI (ISO 3382-3)

Human qualities – objective descriptors

Page 59: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Useful reflections

Detrimental reflections

)end)Energy(50

50ms)Energy(0log(10C50 −

−×= , dB

Definition of room acoustic measures: Speech Clarity C50 (dB)

Page 60: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Room acoustic measures: Sound strength G (dB)

G = LpRoom – Lp10m =Lp – Lw + 31 dB (omni-directional sound source)

10 m

Page 61: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Subjective listener aspect

Room acoustic quantity

Just noticeable difference

Subjective level of sound

Sound Strength G in dB 1 dB

Perceived reverberance

Reverberation time T20 in seconds

5%

Perceived clarity of sound

Speech Clarity C50 in dB 1 dB

Just noticeable difference of room acoustic quantities according to ISO 3382-1

Page 62: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Microphone

Loudspeaker

Reverberation time, T20

Speech clarity, C50

Sound Strength, G

Impulse response

time, s

Room acoustic measurements

Page 63: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Dining/meeting room at a hospital in Landskrona, Sweden.

• It echoes a lot.• If you sit in the middle of the room you

can’t participate in any conversation at all.

• I just take shorts breaks and avoid having lunch together with others.

• Sometimes you have to ask people to repeat what they said.

• There is an incredible din that prevents you from talking, even with the person sitting next to you, when there are a lot of people here.

• I leave the room as fast as possible.

Page 64: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Dining/meeting room at a hospital in Landskrona, Sweden.

Page 65: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Room dimension

Volume = 68 m3

Floor area = 25 m2

Page 66: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Acoustic refurbishment

• Ceiling: Master B

• Wall: Wall Panel C/Texona (2700 x 1200)

0

0,2

0,4

0,6

0,8

1

1,2

125 250 500 1000 2000 4000

Frequency Hz

Pra

ctic

al s

ound

abs

orpt

ion

coef

ficie

nt

Page 67: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Acoustic treatment of dining/meeting room

Page 68: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Room acoustic measurements

1. before acoustic treatment

2. for the room with ceiling treatment only and

3. for the ceiling treatment in combination with the wall panel

Page 69: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Table 2. Result of measurements at Landskrona Hospi tal

Parameter Before acoustic treatment

Only acoustic ceiling

Acoustic ceiling and wall panel

Average 500 and 1000 Hz

Average 500 and 1000 Hz

Average 500 and 1000 Hz

T20 [s] 0.76 0.37 0.27

∆L [dB]* - -8 -8

C50 [dB] 1.8 8.6 12.0

D [%] 60 88 94

RASTI ** 0.66 0.82 0.87

* * ∆L is the reduction of sound levels in the room compared to the untreated room.**Room Acoustic Speech Transmission Index according to IEC 60268-16

Page 70: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Some comments from the staff after the refurbishment

• Much more subdued environment. I feel more relaxed in the room.• It’s easier to talk to each other.• There’s less din when a lot of people are in the same room.• There are less echoes in the room.• A lot of people can talk simultaneously in different parts of the room without a

problem.

Page 71: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Acoustics extremes

Anechoic chamber

Reverberation chamber

Page 72: This slide is used for start page and chaptering. Insert ... · This slide is used for start page and chaptering. Insert your image ... start page and chaptering. Insert your image

Equaliser: Balanced sound for optimal room acoustics

T20 (s) (250 – 4000 Hz) G (dB)

0,200,30

0,80

0,500,600,70

1,001,101,201,30

0,90

78

13

9101112

15161718

14

D50 (%)

5056

80

61677276

86899193

83

Reverberation Sound strength Speech clarity

T20 (s) (125 Hz)

0,200,30

0,80

0,400,500,600,70

1,001,101,201,30

0,90

Example: Classroom, traditional education

1,401,501,501,40 19

20

44

94

0,40