21
For immediate assistance call 1-800-750-6842 This document courtesy of: Data Weighing Systems, Inc. Contact Us

This document courtesy of - Data Weigh

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: This document courtesy of - Data Weigh

For immediate assistance call

1-800-750-6842

This document courtesy of:

Data Weighing Systems, Inc.

Contact Us

Page 2: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

Sartorius AG, Weender Landstrasse 94-108, 37075 Goettingen, Germany Contact: Benno Gatzemeier ! +49+551/308-1661 FAX +49-551/308-3495. Version 1.0

Marketing Information

Sartorius Weighing Technology Cables and Connectors

• Diagrams for connecting Sartorius weighing equipment to PCs, printers, display and control units and accessories

• Diagrams of connections in hazardous areas/locations

• Pin assignments for data interfaces in laboratory and industrial weighing instruments

Page 3: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 2

Page 4: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 3

CONTENTS

INTRODUCTION................................................................................................................... 4

1 OVERVIEW OF CABLES .................................................................................................. 5 1.1 Connecting PCs ...........................................................................................................................................5 1.2 Connecting Printers......................................................................................................................................6

1.2.1 Industrial Printers...................................................................................................................................6 1.2.1 Laboratory and PC Printers ...................................................................................................................7

1.3 Connecting Display and Control Units..........................................................................................................8 1.4 Connecting Accessories...............................................................................................................................9 1.5 Connections in Hazardous Areas/Locations ..............................................................................................10 1.6 Cables and Connectors..............................................................................................................................11

2 PIN ASSIGNMENTS........................................................................................................ 12 2.1 12-pin Round Connectors ..........................................................................................................................12 2.2 Explosion-proof Connectors: 14-pin and 12-pin Round Connectors for Zener Barriers ............................13 2.3 25-pin Sub-D Connectors (current-model weighing instruments) .......................................................14 2.4 25-pin Sub-D Connectors (older-model weighing instruments) ..........................................................15 2.3 25-pin Sub-D Connectors (interface converters) ................................................................................16 2.4 9-pin Sub-D Connectors.............................................................................................................................17

Page 5: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 4

Introduction The equipment used in Sartorius weighing technology, with the numerous interfaces and their various pin assignments, has grown so complex in the past few years that we have decided to create a single information package to provide an overview of the wide range of connection options. This overview is intended to answer questions such as:

• Which devices can I connect to which weighing instruments? • Which connecting cable do I need? • Can my weighing instrument be powered through the data interface? • Which devices have control output lines? • Can the weighing instrument supply power through the data interface?

You will find all of this information in this Marketing Information package. The cables are listed according to the device to be connected (PC, printer, terminal) rather than by weighing instrument model. This is because there are many different weighing instruments that use a single cable type. Weighing instruments that have the same type of connector, with identical pin assignments, are also listed together. The overview of connectors is organized in the same manner. The advantage here is that a table shows the differences between pin assignments at a glance. With all of this information at hand, our resellers can answer customers' questions about cables and connectors without having to call our Customer Service department or the Hotline.

Page 6: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 5

1 Overview of Cables 1.1 Connecting PCs

EA, EB, LA, LP, BP, BL, MA, MC, ME

IS Platform

83,213 kg

isi, FB, FC, FD, QA, QC, QAT, QCT, Zener barrier YDI(01/02/03)-Z

7357314 / 1.5 m

7357312 / 1.5 m

YCC01-0017D2 / 0.3 m

YCC01-03ISM5 / 5 m

YCC01-09ISM5 / 5 m

Adapter cable 25-pin →→→→ 9-pin 6965619 / 0.3 m

113

14

25

15

69

SUB-

D 9

po

lSU

B-D

25

po

l

Page 7: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 6

1.2 Connecting Printers 1.2.1 Industrial Printers

83,213 kg

QA, QC, QAT, QCT YDI(01/02/03)-Z

cable included with printer

LA, LP

isi, FB, FC, FD

Industrial printer YDP02IS-0CE cable included with printer

15

69

Industrial printer NEW YDP04IS-0CE cable included with printer

15

69

Industrial printer YDP01IS-0CE (No longer available) cable included with printer 15

69

EA, EB

Fast Factory cable

Fast Factory cable

15

69

IndustrieDrucker

15

69

Industrialprinter

15

69

IndustrieDrucker

15

69

Industrialprinter

15

69

IndustrieDrucker

15

69

Industrialprinter

cable included with printer

cable included with printer

cable included with printer

Page 8: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 7

1.2.1 Laboratory and PC Printers

83,213 kg

15

69

PMA, CarMix

PC printer

YCC01-0019M3 / 3 m

YCC01-0018M3 / 3 m power supplies necessary

YCC01-0011M1 / 1,5 m

YCC01-0015M3 / 3 m

YCCDI-06M3 / 3 m

YCC01-0011M3 / 3 m

113

1425

COM 1 BNC COM 2 M1

Epson Lx300113

1425

113

1425

LA, LP, BP, BL, MA, MC, ME

direct, cable on printer

isi, FD

113

1425

15

69

9pol cable included with printer

25pol YDP03-0CE YDP04-0CE

YDP02-0CE

FB, FC

YCC01-06ISM3 / 3 m power supplies necessary

YCC01-0016M3 / 3 m

YCC01-0011M3 / 3 m

15

69

Laboratory printer

113

1425

Laboratory printer

Page 9: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 8

1.3 Connecting Display and Control Units

EA, EB, LA, LP, BP, BL, MA, MC, ME

YCC01-02ISM3 / 3 m

113

1425

COM 1 BNC COM 2 M1

YCCDI-02M3(M1) / 3 m (1 m)

83,213 kg

YCC01-04ISM3 / 3 m

QA, QC, QAT, QCT FB, FC

isi

Page 10: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 9

1.4 Connecting Accessories

83,213 kg

FB, FC, only with YDO(03/04)F or LA with YCC01-0024M01

EA, EB, LA, LP, BP, BL, MA, MC, ME,

Industrial checkweighing display unit YRD01IS

direct, cable with the display unit

direct, cable with the display unit

YCC01-0016M3 / 3 m

Sartorius11 3

1 42 5

Laboratory red-green-red display unit YRD01Z

Bar-code scanner YBR02FC

Bar-code scanner YBR02IS

direct, cable with the scanner Isi, FD

direct, cable with the scanner

QA, QC, FB, FC, YDI03Z

Page 11: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 10

1.5 Connections in Hazardous Areas/Locations

I-X, F-X, L-X

83,213 kg

EB-X, FC-X, FCT-X

Zener barrier YDI01-Z

Zener barrier YDI(02/03)-Z

Interface converter 723524

direct, cable with the Zener barrier

direct, cable with the converter

Foot switch YPE(04/05)Z-X

T connecter YTE(01/02)Z-X

YCC01-08ISM5 (Sartonet cable)

Page 12: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 11

1.6 Cables and Connectors

YCC01-01ISM6 69QC0010 69QC0011 YCCDI-03M5 (12-wire) YCC01-08ISM5 (4-wire) 69Y03166 Extension cable 12-pin plug 12-pin socket 12-pin plug with 5m cable 12-pin plug with 5m 14-pin Ex-proof plug Sartonet cable

Page 13: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 12

2 Pin Assignments 2.1 12-pin Round Connectors RU12 isi Terminal

YDO(03/04)IS I/O

FD/isi Terminal YDO(01/02/03)IS RS-232/RS-485

FD/isi Terminal YDO04IS RS-232

Terminal YDI 100 / 150

A K1 Make contact RxD-TxD-N RxD-TxD-N B Input - 2 TxD RxD-TxD-N electrically isolated TxD C Input - 1 RxD RxD-TxD-P electrically isolated RxD D K4 Make contact DTR DTR E K2 Center Signal GND Signal GND electrically isolated Signal GND F K2 Make contact +5V - out +5V - out G K3 - Center Line (11-30V) Line (11-30V) H GND CTS CTS J K1 - Center Line GND Line GND K Input - 3 Line GND Line GND L K4 - Center RxD-TxD-P RxD-TxD-P M K3 -. Make contact Line (11-30V) Line (11-30V)

RU12 FB/FC/QA/QC QAT01/QCT01 RS-232

FB/FC/LA/LP YDO(01/02)F RS-485

IS platform YDO(52/54)IS RS-232

IS platform YDO(50/53)IS RS-485

A > > RxD-TxD-N B TxD RxD-TxD-N RxD C RxD RxD-TxD-P TxD D DTR CTS E Signal GND Signal GND Signal GND Signal GND F +5V - out +5V - out Block calibration/adj. Block calibration/adj. G < < Line (11-30V) Line (11-30V) H CTS DTR J = = Line GND Line GND K Universal in Universal in Line GND Line GND L Set Set RxD-TxD-P M +12V - out +12V - out Line (11-30V) Line (11-30V)

Page 14: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 13

2.2 Explosion-proof Connectors: 14-pin and 12-pin Round Connectors for Zener Barriers RU14 EX-connector Weighing inst. output Zener barrier input

FC-EX / FCT01-X YDI0(01/02/03)-Z RS-232

EB-EX YDI0(01/02/03)-Z RS-232

FC-EX / FCT01-X YDI0(01/02/03)-Z RS-485

A CTS CTS B SBI/BPI C Reset - out D Set Set Set E = = only optional FF = F < < only optional FF < G > > only optional FF > H J RxD RxD RxD-TxD-P K TxD TxD RxD-TxD-N L M Signal GND Signal GND Signal GND N DTR DTR O Universal in Universal in Universal in

RU12 Zener barrier output

YDI02-Z RS-232

YDI03-Z RS-232

YDI(01/02)-Z RS-485

YDI03-Z RS-485

A > > B TxD TxD RxD-TxD-N RxD-TxD-N C RxD RxD RxD-TxD-P RxD-TxD-P D DTR DTR E Signal GND Signal GND Signal GND Signal GND F G < < H CTS CTS J = = K L Set Set M

Page 15: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 14

2.3 25-pin Sub-D Connectors (current-model weighing instruments) DB25 Q… with DB25 EA/EB BL BP LA/LP ME/MA50/100 PMA 1 Shield Shield Shield Shield Shield Shield 2 TxD TxD TxD TxD TxD TxD TxD 3 RxD RxD RxD RxD RxD RxD RxD 4 Signal GND Signal GND Signal GND Signal GND Signal GND 5 CTS CTS CTS CTS CTS CTS CTS 6 intern.

connected intern. connected intern.

connected intern. connected

intern. connected

intern. connected

7 Signal GND GND GND GND GND GND Signal GND 8 Signal GND GND GND GND GND GND 9 intern. connected Reset - in Reset - in Reset - in 10 -12V out -12V out 11 +12V out +12V out +12V out +12V out +12V out 12 +5V out Reset - out Reset - out Reset - out Reset - out Reset - out 13 +5V out intern. connected +5V out +5V out +5V out +5V out 14 Signal GND GND GND GND GND GND Signal GND 15 Universal in Universal in Universal in Universal in Universal in Universal in 16 < < only optional FF In tare / out < Digital I/O 17 = = only optional FF In cal / out = Digital I/O 18 > > only optional FF In F / out > Digital I/O 19 Set In CF / out Set Digital I/O 20 DTR DTR DTR DTR DTR DTR DTR 21 Line GND Line GND Line GND Line GND Line GND 22 intern. connected 23 intern. connected 24 Line (12-30V) Line (15-25V) Line (15-25V) 25 +5V out +5V out +5V out +5V out +5V out

113

1425

Page 16: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 15

2.4 25-pin Sub-D Connectors (older-model weighing instruments) DB25 MC1 MC_SC PT/GT MA30/40/50 Computer M8-4 1 Shield Shield Shield Shield Shield 2 TxD TxD TxD TxD TxD TxD 3 RxD RxD RxD RxD RxD RxD 4 Signal GND Signal GND Signal GND Signal GND GND extern 5 CTS CTS CTS CTS CTS CTS 6 SPI/BPI switch signal intern. connected intern. connected intern. connected GND 7 GND GND GND GND Signal GND GND 8 GND GND GND GND intern. connected 9 Reset - in Reset - in Reset - in Reset - in 10 -12V out -12V out -12V out -12V out 11 +12V out +12V out +12V out +12V out 12 Reset - out Reset - out Reset - out Reset - out Reset - out 13 +5V out +5V out +5V out +5V out +5V out 14 GND GND GND GND Signal GND intern. connected 15 Universal in Universal in / Print Print Print 16 < Open/close draft

shield / Ctrl. output Tare < / Tare

17 = F1 / Ctrl. output = 18 > F2 / Ctrl. output > 19 Set Tare / Ctrl. output 20 DTR DTR DTR DTR DTR DTR 21 Line GND Line GND Line GND 22 23 24 Line (11-30V) Line (15-25V) 25 +5V out +5V out +5V out +5V out +5V out

113

1425

Page 17: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 16

2.3 25-pin Sub-D Connectors (interface converters) DB25 Interface Converters 725324 RS-232

Standard D-Sub 25p up to 15m

RS-232 Sartorius D-Sub 25p up to 15m

RS-423 D-Sub 25p up to 300m

RS-422 D-Sub 15p up to 3000m

RS-485 D-Sub 25p up to 3000m

TTY-20mA D-Sub 25p up to 300m

Ex-proof scale D-Sub 9p up to 300m

1 Shield Shield Shield Shield Shield Shield Shield 2 TxD TxD TxD TxD TxD 3 RxD RxD RxD CTS RxD 4 Ext. GND Ext. GND RxD 5 CTS CTS CTS DTR CTS 6 7 Signal GND Signal GND 8 Signal GND 9 TxD inverted Send + DTR 10 CTS inverted Send - 11 RxD inverted 12 DTR inverted 13 14 Signal GND Signal GND 15 16 17 18 19 20 DTR DTR DTR 21 22 RxD-TxD-P 23 RxD-TxD-N 24 Receive + 25 Receive -

113

1425

Page 18: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 17

2.4 9-pin Sub-D Connectors DB9 ME

socket PMA socket

PC / CarMix plug

YSPI3-232 socket

YSPI3-485 socket

YSPI3-Profibus socket

Printer YDP (02/03/04)-0CE

Printer YDP (01/02)IS-0CE

1 DCD Shield Shield Shield +5V out +5V out 2 TxD RxD RxD TxD RxD TxD 3 RxD TxD TxD RxD RxD-TxD-P B line TxD RxD 4 CTS DTR DTR RTS DTR 5 GND GND GND GND GND GND, +5V GND GND 6 DSR +5V out +5V out +5V out Reset RDY 7 RTS CTS 8 DTR CTS CTS DTR RxD-TxD-N A line CTS RDY 9 Universal in RI Line 12V

15

69

Page 19: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 18

Page 20: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

/ 19

Page 21: This document courtesy of - Data Weigh

Sartorius Cables and Connectors

Sartorius AG, Weender Landstrasse 94-108, 37075 Goettingen, Germany Contact: Benno Gatzemeier ! +49-551/308-1661 FAX +49-551/308-3495. Version 1.0