1 Proprietary & Confidential
The world leader in serving science
Proprietary & Confidential
Rich Palatine
June 2, 2016
Thermo Scientific Nuclear Power Instrumentation Update
2 Proprietary & Confidential
“Topics to be Covered”
Rad Eye NL+ Moderator, B 20 and others
NEW RID Eye XG : Gamma Isotopic Meter
NPP ‘New’ Service Offerings
3 Proprietary & Confidential
RadEye™ Family History
•First model introduced in 2002; gamma dose
rate and personnel dose (Rad Eye G); post 9/11
•Over past 13 years, have added 10+ different
models and 20+ different variants
•Core design remains same for all
models/variants (PCB, case, display, etc.)
•Through 2015: >75,000 units world-wide in
many different markets
•Simple & Rugged enough for NYPD/NYFD
means NPP HP’s should have no prob’s
4 Proprietary & Confidential
Current US NPP’s using the Rad Eyes ….in some form
•TVA (3 sites): Rad Eye B20 ER: Dual
Survey + Dose Rate Instrument
•Surry/North Anna: Rad Eye G, Rad
Eye GX, and PRD: Gamma Dose
rates/uR Meter
•Turkey Point: Rad Eye PX + Rem Ball;
neutron Dose rates
•VC Summer; Rad Eye G’s for D.R.
Surveys
•Several others ……..
Duke, TVA, North Anna, VC Summer
conducting Neutron Rad Eye Testing
Exelon (LaSalle) conducted
evaluation in 2015 …generally positive!
↑ Acceptance due to Size, Durability and $$
5 Proprietary & Confidential
RadEye NL Details and Accessories
• Much Lighter than traditional Rem Ball N meters; Eliminate
Safety Hazard of climbing, etc!
• Add Rad Eye G and get N and Gamma readings w/ 1 Hand!
• Easy to Calibrate; H3 Detector
• Easy to use Neutron Moderator
• Can be set for minimal gamma spill over
• Same size and weight as traditional RadEyes
• All standard RadEye accessories compatible (including s/w)
• Wolfcreek purcahsed and implementing (2016); nice job James!
• Duke Power, TVA, North Anna and VCS currently evaluating
• Cheaper than Rem Ball + ASP 2 Meter!
• QSA Global Data vs REM BALL..calibration procdure basics
6 Proprietary & Confidential
Cf 252 md Testing and CF Determination
Units Measured Dose Rate #1 Dose Rate #2 Dose Rate #3 Dose Rate #4
mR/hr 19 210 1960 5300
mSv/hr 0.19 2.1 19.6 53
uSv/hr 190 2100 19600 53000
CPS reading 72 782 6430 15200
CF (uSv/hr/per cps) 2.6 2.7 3 3.5
mR/hr per cps 0.26 0.27 0.30 0.35
0
1
2
3
4
0 2000 4000 6000
RAD EYE NL Cal FX vs Dose Rate (mR/hr) for Mod Cf-252
7 Proprietary & Confidential
Multi-Purpose Survey/Contamination Meter Rad Eye B20 ER
Pancake Geiger Frisker + Dose Rate
Meter (Ion Chamber Replacement!)
•Beta Contamination + DR Meter
•Scaler/Counter
Gamma dose rate with Energy
Compensation Filter
•Easy to switch from CPS to mR/hr
(Tissue Equivalent---use as ion
chamber reading! )
•One handed; wear on belt!
•B20-ER 10 R/hr range
Single Instrument on belt for DR’s and Frisking!
8 Proprietary & Confidential
TVA Feedback ‘User Feedback Summary’
• Some of the advantages we have seen:
• 1. One instrument will perform the job of three instruments
(DR, CR, and micro-rem).
• 2. Savings in calibration and source response check costs
• 3. Since we issue each individual their own RadEye, less
damage and breakage. The technicians are responsible for
performing and documenting their own source checks
• 4. Less safety risk, as the instruments are easier carry when
climbing ladders and moving around the site.
• 5. They can be used in Noble Gas areas without worrying
about the detector filling up with noble gas.
• There are some minor challenges: FME controls w/ filters, a
filter has been lost, & magnets out of a couple units
9 Proprietary & Confidential
RadEye G & G-10 Dose Rate Meters
• General purpose gamma survey meter; RP
Supervision to have in pocket for field dose
rate verifications!
• Range up to 10 R/h
• Criticality and Area Monitor Applications
10 Proprietary & Confidential
Simple, EXEMPT, easy to use Lutetium (Lu2O3) source check
• 3.7E10 year half-life means:
no need for error-prone half-life corrections
• No need for reoccurring purchase of the
(decayed) check sources
• The adapters provide a highly reproducible
and uniform activity content: 50 Bq/g (1.3 nCi/g)
• All test adapters of the same type have the same
activity!
• Beta-type adapters provide identical surface
emission rates
γ Energy 8 keV, 54 keV, 55 keV, 63 keV, 88 keV, 202 keV, 307 keV, 401 keV
Β Energy 188 keV, 589 keV
These energies are ideally suited to simulate a mixture of Am-241, Pu-239, U-235 and heavily
shielded industrial sources (Cs-137, Ir-192, Co-60):
11 Proprietary & Confidential
RadEye – X Series
A RadEye-X Solution for Every Application
3500 Reader
4500 Reader
5500 Reader
Variant Detector
Type
Probe Category Application
RadEye-
GX/GXL
Geiger-Mueller
(GM)
Dose Rate, Pancake Gamma Dose Rate
Surveys, Object &
Personnel Frisking
RadEye-
PX
Proportional Neutron, Air
Proportional, Gas
Proportional
Neutron Dose Rate
Surveys & Surface
Contam.
RadEye-
SX
Scintillation PMT based probes i.e.,
surface contamination,
NaI
Alpha and/or Beta
Surface Contam,
High Sensitivity
Gamma
12 Proprietary & Confidential
RadEye SX
Multi-purpose Meter for external Scintillation Probes
13 Proprietary & Confidential
Rad Eye’s Missing Link …. Quick & Easy Wearable Telemetry
CNET 600 Key Features:
• Low powered Mesh wireless network with
backward compatibility paths for existing CNET
mesh customers
• Bluetooth Low Energy capability for communication
with nearby devices like the Rad Eye BT PD
• XBee based high power radio provides longer
range wireless communication (various – 900MHz,
2.4GHz, Wi-Fi)
• Very compact design
• USB port for easy PC configuration – also used as
an external Power Port
• 2 x AA batteries for standalone operation.
Convenient sliding latched cover.
• Standard DE-9 serial instrument port offers a
RS232 or RS485 2/4 wire connection to
instruments
• Compatible with ViewPoint and other industry
standard software packages
• Supporting hardware exists (base radios, etc.)
14 Proprietary & Confidential
The Rid Eye X-G Gamma Spec Meter
X stands for Extreme
• 2” x 2” NaI Detector + Large Color Coded Display
• Fastest & most accurate radio-isotopic identification –
Live spectrum building w/ color coded peaks
• Rugged construction of RIIDEye X stands up to harsh
NPP-type environments
• Low cost of ownership – Fair acquisition price, NO
maintenance or calibration needed for life of
instrument; only source check required prior to use!
• Easy to Use – Clear, simple screens display critical
information; new users proficient in just a few min’s!
15 Proprietary & Confidential
RIIDEye: Simple to Use
1. Switch on, wait for Auto-Cal to be completed
2. Use arrows to highlight Identify on command line
3. Press Enter
4. View live spectrum display and colored peak classification during count
5. View result screen
6. Note nuclide, classification and confidence of identification
7. Stored spectrum and data can via telemetry for remote
Simple instructions for easy operation
16 Proprietary & Confidential
The Rid Eye X-G NPP Applications
• Control Point Alarm Investigation: What is
the contamination?? Noble Gas? Medical?
NORM?, Plant Mix? Locate and ID
…almost immediately (seconds); Eliminate
Count Room Trips
• Rad Waste: Waste ID, Verification, etc.
• EP: Release Verification, Supplement Rad
Halo in Plume Location, Iodine (Yes or No?);
Sample Analysis
• ??????
17 Proprietary & Confidential
NEW Certified Outage Support Offerings
•Pre-Outage SupportConfigurable pre-outage support program ranging
from preventative maintenance, calibration checking,
calibration services, & system optimization.
•Outage SupportConfigurable outage support program offering ranging
from emergency replacement kits, on-site
instrument/systems support.
•Post-Outage SupportCustomizable post-outage support: Repairs of outage
damage; etc
•Instrument Procedure Development Plant instrument procedure development; turn-key
instrument procedures written by SME’s for new or
existing Thermo instruments.
Customized Outage/Non-outage Support Packages fit your needs