Upload
bonifacy-ania
View
31
Download
0
Embed Size (px)
DESCRIPTION
Thermal Cycling Tests of Dummy Modules. Setup Pre-cycling resistance measurements IZM module results Alenia module underway. Setup. Modules built with CERN Flex V.2 and bare dummy module. Used Ecobond glue under MCC, pigtail bonding field, and 4 corners. - PowerPoint PPT Presentation
Citation preview
Thermal Cycling Tests of Dummy Modules
• Setup• Pre-cycling resistance
measurements• IZM module results• Alenia module underway
Setup
• Modules built with CERN Flex V.2 and bare dummy module.
• Used Ecobond glue under MCC, pigtail bonding field, and 4 corners.
• Modules used for FE wirebonding tests prior to thermal cycling
• First cycled modules unconstrained, then attached to sector using CGL and UV-cure tacks on 4 corners.
• Cycled 21oC to –35oC in environmental chamber.
• Monitored module temperature and chain resistance in real time
Setup (cont.)
Only 4 columns monitored in real time during cycling
All columns measured on probe station before and after
Column Resistances (before cycling)
IZMAlenia
Bad chip
IZM Module results
• No change after 2 cycles of unconstrained module
• No change DURING 19 cycles of module on sector
• Open columns detected AFTER overnight storage at 21oC
RED = location of open column32/270 columns failed
On bad chip, all columns were open prior to tests & chip fell off after removing module from sector. Solder bumps left ½ on chip ½ on sensor.
Possible Explanation
• Results are consistent with differential movement of dummy chips and dummy sensor.• For example, assume sensor doesn’t move under cooldown(probably not correct, just
example), then contraction of each chip is about (2.5x10-6) x(either 3.7 or 5.5x103
microns)x56=0.5-0.8 microns.• Worst case is corners of chip, but we only measure columns.• Approximate strain is (0.5-0.8)/(20) or 2.5-3.8%.. Solder stress vs strain becomes non-linear
for strains above about 1%.• Creep rupture is possible explanation for failure after sitting.
UV Tack UV Tack
Carbon-carbon on sectorCGL
Alenia Module Tests Underway
• 3 Cycles to –35o unconstrained
• 3 Cycles to –35o mounted on sector
• Time at –35o 30-40 minutes/cycle
• Let sit for a day
• No failures yet
• Tests continuing