The World's Most AdvancedUniversal AC Drive
Features
6 control modes
· V/f variable torque control
· V/f constant torque control
· Sensorless vector control
· Closed-loop vector control
· Sensorless PM motor control
· Closed-loop PM motor control
Intelligent
· User-programmable built-in PLC
! Application-specific features
+ PID control
+ Multi-pump control
+ Traverse control for fibre
machines
+ Spinning ring frame
+ Energy optimiser
+ Elevator programme
Environment-friendly
! Optional built-in EMC filter
(up to 30kW in 400V series,
5.5kW in 200V series.)
! Optional built-in DC reactor
! (37kW in 400V series,
! 22kW in 200V series, and above)
! RoHS Directive compliant
! Selectable Soft-sounds
! High-efficiency operation
! Dioxin-free plastic cases
Global Design
! UL, cUL and CE compliant
! Fieldbus interfaces
(Modbus, Profibus-DP,
DeviceNet, CANopen, CC_Link)
! LED display as standard
! Multi-language LCD monitor as option
AN ISO 9001 : 2008 COMPANY
2
Built-in PCB options
Wall-mounted, Free-standing type (optional) for 022L and above
2Altitude: 1000m (3300 ft) or less, Vibration: 4.9m/s or less, From corrosive or explosive gases, steam, dust, oil mist, or cotton lint.
4P0H
Wall-mounted Standard, Free-standing (option) 037H (37kW) and above.
4P0L
: Enhanced type (018H ~ 037H)E
External (option)
External (option)
External (option)
Built-in (Standard)
Built-in (option)
DC Reactor
DBR resistor
DBR control circuit
Installation system
Installation system
DBR resistor
DBR control circuit
DC reactor
Rated output voltage 5
Output frequency range
EMC filter
60 Hz + 5%
200~240V (Max.) 200~230V (Max.)
0.1 to 440Hz
External (option)
Built-in (option)
Built-in (Standard)
Built-in (Standard)
Built-in (option) External (option)
External (option)
External (option)
3
3 4 5 6 7 8
Carrier frequency (kHz)
Ou
tpu
t c
urr
en
t (%
)
Ratedcurrent
5% of rated current
Fig. 1 Derating according to carrier frequency
oAmbient temperature ( C)
Outp
ut c
urre
nt (%
)
20 30 40 50 60
100
90
80
70
60
50
40
30
20
10
Fig. 2 Derating according to ambient temperature
Note : 1. The output voltage indicates the output capacity [HP] at 200V for the 200V series, and 400V for the 400V series. 2. Indicates the total effective value including the higher harmonics. 3. Indicates the case for the standard 4-pole squirrel cage motor. 4. If the carrier frequency exceeds 4kHz, the rated current must be reduced. Please ref. fig.1. 5. An output voltage exceeding the input voltage cannot be attained.
6. Any optional accessory will be provided at extra cost and to be specified in order clearly.
380 to 480V +/-5%, 50 or 60 Hz ± 5%
External (option)
External (option)
External (option)
Wall-mounted (standard) / Free-standing (option)
EMC filter
DBR control circuit
DBR resistor
Installation system
Protective
Control Specifications Table
V/f control Sensor-lessvector control
Vector control withencoder
1
PM motor controlwith encoder
2
Fre
qu
en
cy C
on
tro
lC
on
tro
l sp
eci
fica
tion
sS
ett
ing
Linear/S-character selective
8 stepsAcceleration / Deceleration time as programmable
5-bit non-encode mode
Braking start speed set between 0.00 and 50.00%Braking current set between 50 and 150%
Up to 1 : 7
± 0.01%
0.01 to 60,000 secAcceleration/deceleration time x 2, jogging dedicated X1, program cushion x 8
Multi-step frequencySetting
1 : 100
Up to 1 : 2
± 0.5%
5Hz
1 : 1000
Up to 1 : 4
± 0.01%
30Hz
1 : 100
Up to 1 : 1.5
± 0.01%
–
4
0.03% (analog)
.
Control Specifications Table (continued) AXPERT-VT240S
V/f control Sensor-lessvector control
Vector control withencoder
1
PM motor controlwith encoder
2
Se
ttin
gC
on
tro
l in
pu
t/o
utp
ut
Con
trol i
nput
/out
put
Cont
rol
Comm
unica
tion
Pro
tect
ion
10-step automatic run function Synchronous / Asynchronous selective
5
6
(DBR)
Type Dimensions in mm (Inch) Approx.weightkg(lb)
Wall Mounted Unit200V 400V W0 H0W1 H1
0P7L
1P5L
2P2L
5P5L
4P0L
140(5.51”)
0P7H
1P5H
2P2H
5P5H
4P0H
155(6.10”)
250(9.84”)
235(9.25”)
180(7.09”)
6(0.24”)
3 (6.6)
φEφdD
7P5L 7P5H
011L 011H
015H
190(7.48”)
205(8.07”)
275(10.83”)
260(10.24”)
196(7.72”)
7(0.28”)
12 (26.5)
5 (11.0)
240(9.45”)
260(10.23”)
350(13.78”)
330(12.99”)
298(11.73”)
015L
018L
175(6.89”)
235(9.25”)
330(12.99”)
312(12.28”)
189.5(7.46”)
018HE
022HE
7(0.28”)
10 (22.0)
200(7.87”)
260(10.24”)
350(13.78”)
335(13.19”)
195(7.68”)
030HE
037HE
7(0.28”)
11.5 (25.4)
022L
030L045H
055H
200(7.87”)
300(11.81”)
470(18.50”)
450(17.72”)
317(12.48”)
10(0.39”)
15(0.59”)
23 (50.7)
27 (59.5)
30 (66.1)037L
045L340
(13.38”)240
(9.44”)
520(24.47”)
500(19.69”)
075H
090H
110H
132H
160H
200H
250H
315H
400H
475H
090L
075L
055L435
(17.13”)300
(11.81”)615
(24.21”)595
(23.43”)350
(13.78”)10
(0.39”)20
(0.78”)
42 (92.6)
45 (99.2)
60 (132.3)
65 (143.3)
90 (198.4)
100 (220.5)
200 (440.9)
285 (628.3)
290 (639.3)
295 (650.4)
23(0.90”)
13(0.51”)
15(0.59”)
470(10.50”)
580(22.83”)
400(15.75”)
870(34.25”)
600(23.62”)
1260(49.61”)
1230(48.43”)
500(19.69”)
400(15.75”)
710(27.95”)
684(26.93”)
1020(40.16”)
990(38.98”)
1260(49.61”)
1230(48.43”)
D5
d
φdW0W1
Note: The above-mentioned dimensions are applicable when no DC reactor is mounted on the main unit. Please inquire for the dimensions with the DC reactor.
-
E
User Selectable Functions
PID Control
Multi-pump Control
Ratio Interlock Setting
External Brake Control
User-programmable built-in PLC
Flying Start or Catch-a-Spinning Load
Traverse Run
Automatic Braking on power failure function
Pattern run function
Pressure FB
r
AI* PID
monitor
M
MPump 1
MPump 2
MPump 3
MPump 4
MPump 5
MPump 6
MPump 7
MPump 8
(MPO1)
(MPO2)
(MPO3)
(MPO4)
(MPO5)
(MPO6)
(MPO7)
(MPO8)
VT240S
(AI*)
System power
P
P
P
P
P
P
P
P
Pre
ssu
re s
en
so
P
PSO1
PSO2
PSO3
PSO4
PSO5
PSO6
PSO7
PSO8
* MP01 to 8 are sequence outputs
Example of system configuration (When operating nine ON/OFF control pumps)
External brake sequence example with program setting used (B46-0 f2=1), and brake answer (B46-5=0.0)
RUN
B46-1(LB)
B46-2(BL)
B46-3(DB)
B46-4RUN errordetermined
ZSP
S-shape disabled
Program setting input
Internal program settings
No change made
External brakecommand (MBRK)
External brake answer(MBRK_ans)
Output frequency/motor rotation countcommand
0 7 3 0
0 7 3 0
Auxiliary Motor Control
Auxillarydrivemotor
Powersupply
Input OFF
ON
Control switching command(AUXDV)
Control switching confirmation(AUXDV)
Output Maindrivemotor
IMor
PM
IM
Main Drive Control(Selected with) C30-0
Auxillary drive control(V/F Control)
Sequence Input Sequence Output
AXPERT-VT240S
Co
ntr
ol
Se
lect
ion
AUXDV
B51-1B50-1
B53-2
B54-1
B52-1
Time
RUN
Step-2B52-2
Step-3B53-2
Step-4B54-2
Step-1B51-2
Step-0B50-2
Coding
��
��
�O
�O
�O
�O
�O
�O
Input Output
RemoteI/O
RemoteI/O
��
��
��
��
Ladder
Function Block Diagram
InstructionLanguage
Programcode
Programcode
Interpreter
Internalmemory
Operation panel orSerial communication
AXPERT-VT240S
Y = AX + B + C X: Frequency (speed) setting input A: Coefficient Y: Frequency (speed) command B: Bias 1 (operation results) C: Bias 2
Sequence input IPASS : Ratio interlock bypass (C03-A) BUP : Ratio interlock bias increase (C04-9) BDW : Ratio interlock bias decrease (C04-A) IVLM : Ratio interlock bias increase/decrease
selection (C04-B)
Frequency(speed) settinginput
(X)
Coefficient
(A) (B)
(X')
Bias
(B')
(B'')
on
off
IPASS
(X')(C)(B')
Z-1
IVLM
Bias(C07-3)
(C)
BUP
BDW Acceleration/deceleration ramp rate
Frequency(speed) command
Z-1
off
on
:*1.&
:DWH $DWH
Currently valid ramp deceleration rate
Currently valid ramp acceleration rate
Bias increace/ decreace buffer value (B")
0 clear
Time
IVLM
BDW
BUP
0
Cente
r fr
equency
(sp
eed)
Traverse run
0
RUN ONOFF
PROG ONOFF
FH (B45-0)
B (B45-3) C (B45-4)
D (B45-2)A (B45-1)
A (B45-1)
D (B45-2)
AI1 or AI2
VT240S
0-10V or 4-20mA
Speed sensorCushion
AI3
C12-9
PID+
–
PID operation block
AI3
Max. frequency B00-4 orMax. speed B01-4
Differential time constant (B43-2)
Integral time constant (B43-1)
Proportional gain (B43-0)
Frequency (speed) setting
Upper limit (B43-3) Lower limit (B43-4)
0 to 100%
Limit
PID+
–
AI1 or AI2
PumpM
Converter0-10V
7
Ch
an
ge
ove
r fr
eq
ue
ncy B
12
-6
Subtracted frequencyB12-4
Deceleration ramp time 1 B12-2
Deceleration ramp time 2B12-3Output frequency
Time
Output frequency
Max.Frequency
Setting reequency
Motor speed
Motor current
C21-3 (100%)
B 18-0 (150%)
Output Voltage
tpw
C21-2 Pick-upcurrent
limit
V/fmatch
Re-accelerationafter V/f match
E-6, GIDC Electronics Zone, Gandhinagar - 382028, Gujarat, India.Phone: +91-79-23289101, 23289102, 23289103 | Fax: +91-79-23289111Email: [email protected] | Website: www.amtechelectronics.com
Specifications in this catalog are subject to change without notice.
OUR OTHER OFFERINGS
We provide complete motion control system solutions or individual system components to address industry specific requirements and optimize your process.
Our solutions are simple, compatible and environment friendly, resulting in efficient production, cost optimization a n d m i n i m i z i n g h u m a n intervention. It even leads to energy conservation especially i n t y p i c a l F a n , B l o w e r applications.
Flagship Solutions
l AXPERT-EAZY AC Drive
l AXPERT-VT240S AC Drive
l AXPERT-HIVERT Medium Voltage Drive
l AXPERT-OPTI torque Soft Starter
l AXPERT-EAZY HF-High Frequency Drive
Applications
l Fans, Blowers, pumps
l Compressors, Centrifuges
l Agitators & Conveyors
l Oil & Gas
l Mining
CA
T.N
O. :
AE
IL/V
T24
0S/0
6-15
“Automation made Easy” is our philosophy to simplify the increasing complexi ty of modern production systems through our AMTECH JETTER PROCESS PLC Technology platform.
We simplify the contradictory imperatives in modern auto-mation to provide simplistic but cost effective customized solutions.
Flagship Solutions
NANO, DELTA, M IKRO, JETWEB, JETVIEW, HMI & SCADA, SERVO & AXES CONTROL SYSTEM
Applications
l Paper Machine Automation
l Textiles Manufacturing
l Packaging
l Winder Machine
l Crane & Material Handling Equipment
l CNC Machines
l Semiconductor Assembly line
l Retrofit solutions
Amtech 's Power Qual i ty Solutions offer you the synergy of multiple benefits - energy conse rva t i on , enhanced operational efficiency and reliability through a dedicated r a n g e o f p r o d u c t s a n d services.
Products
l Passive Harmonic Filter
l Active Harmonic Filter
l Harmonic Reactor
l Static Harmonic Converter
l EMI/RFI Filter
l Sinus Filter
l Active Front end Converter
Services
l Harmonic Audit and Solutions to comply with IEEE-519 standard
l System design, optimization & pay-back analysis
l Consultancy for Power Quality improvement
l Training on Power Quality Management
l Energy Audit and solutions by experienced BEE certified professionals
We offer technology solutions to independent R&D labs as well as industrial segments, l ike Traction, Renewable Energy sources (Wind, Solar etc.) thereby zeroing your lead time to commercialization.
Products
l Traction Drive
l High Voltage Power Supply
l Battery back-up drive & systems for critical loads
l Wind Power Converter
l Solar Inverter
Services
l Retrofit Solutions
l Customized solutions for industry specific applications
l Solution for Oil, Gas & Mining
l Power Electronics Technology outsourcing
MOTION CONTROL AUTOMATION POWER QUALITY INDUSTRIAL ELECTRONICS
“DRIVE FOR SUCCESS”“AUTOMATION.MADE EASY”
“ONE STOP SOLUTIONTO QUALITY POWER”
“YOUR TECHNOLOGYPARTNER”
i-SineAXPERT-Active Harmonic Filter
i-SineAXPERT-Active Harmonic Filter
N o r m0 . 0 % L 4 1 5 V r y0 . 0 l r 0 0 V oV R a m p . L c l , S t o p