r Dry Gas system was initially designed as a standalone unit meant t through manual and pneumatically driven valves. ion criterion for the gas source was based on the available gas pres of the detector (detector open, people working=>Dry Air is the gas er cases Nitrogen is the gas of choice). election line has been implemented onto this, based on the monitored ors read via the “Monitor” Tracker PLC which led to decisions on the e actions that define the Dry Gas source are performed via the “MAST C following the Tracker TSS “philosophy”. The “Monitor”<-> “MASTER” ion is based on hardware, dry contact exchange. TIB- TIB+ TEC- TOB- TOB+ TEC+ MASTER MONIT OR Therma l Screen Cable Channe l Pix

The Tracker Dry Gas system was initially designed as a standalone unit meant to be

  • Upload
    zelig

  • View
    31

  • Download
    0

Embed Size (px)

DESCRIPTION

The Tracker Dry Gas system was initially designed as a standalone unit meant to be operated through manual and pneumatically driven valves. The selection criterion for the gas source was based on the available gas pressure and - PowerPoint PPT Presentation

Citation preview

Page 1: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

The Tracker Dry Gas system was initially designed as a standalone unit meant to be operated through manual and pneumatically driven valves. The selection criterion for the gas source was based on the available gas pressure and the status of the detector (detector open, people working=>Dry Air is the gas of choice; in all other cases Nitrogen is the gas of choice). A second selection line has been implemented onto this, based on the monitored values from sensors read via the “Monitor” Tracker PLC which led to decisions on the gas source. The actions that define the Dry Gas source are performed via the “MASTER” Tracker PLC following the Tracker TSS “philosophy”. The “Monitor”<-> “MASTER” communication is based on hardware, dry contact exchange.

TIB- TIB+TEC- TOB- TOB+ TEC+

MASTER MONITOR

Thermal Screen

Cable Channel

Pix

Page 2: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

Enable dry gas, enable dryer

Enabled dry gas, enabled dryer

To Gas Room

Page 3: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

Monitor Analog Inputs• The Monitor currently checks and issues directions to

the Master:– Two Dew Point temperatures in what should be the ones of the dry

gas flowing to the Tracker; dew-point limits set to -45 0C for N2 and -15 0 C for Dry Air.

• It additionally reads Analogue values:– One Dew Point temperature at the output of the Air Dryer (limited to

>= -65 Celsius);– The total dry gas Flow to the Tracker (limit set to 12m3/hr ) ;– The Pressure in the Air Dryer line;– The Pressure in the Air Bottles line – broken.– The Pressure in the Dry Air line to the Trimatic;These pressure meters are not maintainable; when we change the one

in the air bottles we change them all.

Page 4: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

Dryer Electrovalve

Dew-point meter #3

N2 Electrovalve

Trimatic indicators in the horizontal direction= N2, vertical=Dry Air

Page 5: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

Monitor Digital Inputs• The Monitor reads Digital states:

– The Open/Closed status of the pressure-actuated valve on the Nitrogen line (1 bit);

– The Open/Closed status of the pressure-actuated valve on the Dry Air line (1 bit);

– The Open/Closed status of the pressure-actuated valve on the Air Dryer to Dry Air line (1 bit);

– The Open/Closed status of the pressure-actuated valve on the Air Bottles to Dry Air line (1bit, broken, to be changed);

Page 6: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

Dry Air source switchboard

Dryer

Push-buttons

Bottles

When going back from bottles or from Dryer, the red pushbuttons have to be used, then no MASTER Acknowledge needed; pressure-driven action

Master acknowledge

When going back from dew-point dry gas source change a MASTER Acknowledge needed; MASTER-drivenaction

Page 7: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

Master Digital Outputs• The Master, on the basis of two Digital lines from the

Monitor, currently controls:– One electro-pneumatic valve on the Nitrogen line (Request

Nitrogen Enable to allow flow);– One electro-pneumatic valve on the Air Dryer to Dry Air

line (Request Dryer Enable to allow flow);• In case of out-of-limits dew point measurement or

flow, the Master sends the request to go to warm to the Cooling plants, as well as changes the Dry Air source. This is not a topic of the current meeting, however the implementation and procedure has been tessted thoroughly.

Page 8: The Tracker Dry Gas system was initially designed as a standalone unit meant to  be

The changes of the Dry Panel – Dry bottle switch and the change of the pressure gauges are important and should be carefully scheduled since both the gas group and the TSS group have to test and work together.The coming interventions, in July, are by far less intrusive and have to do withthe Dry Gas source for the cold boxes. However, they will still be performed together since we would like to avoid any disruption to the cooling plant operation. We should plan on a “meeting of experts…Andrea, PGV, machi” on the 15th forPreparing the action list and the software changes during the intervention if any will be needed.