EcoNetTM Control Center Home control with intuitive LCD
touchscreen navigation
PRINTED IN U.S.A. 3/14 WP FORM NO. CORP-RU-ECO-2014-3-REV
Rely on RuudTM
INTEGRATED CONTROLS
UETST600SYS
Efficiency Controls 65%** or more of a typical home's energy use from a single interface• Reduces energy costs by up to 30%*
Performance• Built with our 360°+1 Philosophy for
optimal Performance, Integration, Installability and Serviceability
• Control from anywhere with system-wide remote wireless, air and water system management web portal, and mobile applications
Operation Modes• Modes include:
- Heat - Cool - Auto (includes Vacation mode) - Emergency Heat - Fan Only
Compatibility• Fully integrates with:
- U96V and U97V Gas Furnaces (U97V available Q4 2014) - CC2 AC/HPs - AC/HP Line*** - Heat Pump Water Heaters - Gas Water Heaters*** - Electric Water Heaters - Gas Pool & Spa Heaters*** - Heat Pump Pool & Spa Heaters***
Display• Full-color, 4.7"x1" depth LCD
touchscreen display• Attractive, modern design with
interchangeable faceplates•Easy-to-read icons and text•Indoor/outdoor temperature display
Easy Installation•Simple 4/3 wiring • Advanced setup tools automatically
recognize and configure connected equipment and select optimal operating mode
Intuitive Programming• Lifestyle-based scheduling with 1-touch
mode selection (including 1-touch vacation mode)
• Auto-mode control automatically switches between Heat and Cool mode to maintain set temperature range
• Continuous Fan Mode ensures even temperatures and continuous air filtering throughout home
• Humidification (auto/manual) & Dehumidification
•Low Ambient Cooling
Interchangeable Faceplates• Shown with black, includes easy-to-
change soft white and taupe
Warranty• 5-year limited warranty
(5 years from date of installation)
* When compared to non-programmable thermostats. Source: ENERGY STAR for Programmable Thermostats
**Source: Department of Energy***Future-generation
DESCRIPTION FEATURESROUGHING IN DIMENSIONS
(SHOWN IN INCHES)
Model Number Programmable Duel Fuel Ready
Auto Change Over
Programmable Fan
System Switches Fan Switch Warranty Depth
AWidth
B
UETST600SYS Yes Yes Yes Yes
Heat, Cool, Auto, Emer-gency Heat,
Fan, Off
5 Speeds, Off 5-Year Limited 1 4.7
The Ruud EcoNet™ Control Center, our intuitive, integrated air and water management system, customizes comfort while cutting energy costs* from anywhere.
RuudHeating,Cooling&WaterHeating•P.O.Box17010,FortSmith,Arkansas72917•www.ruud.com
Full-Color LCD Touchscreen Interface
In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.
StatusSettings
heat set pointinside
Service HeatMode
72°
outside
72°Wed. Jan. 1, 6:00 am 55º
1 2 3
4
5679
8
1 EcoNet Logo – Touch to access and control connected air and water equipment
2 Day, Date and Time – Touch the settings icon to adjust
3 Outside Temperature Display – Displays the current outside temperature
4 Temperature Set Point – Touch the corresponding arrow to adjust the temperature set point up or down for comfort
5 Mode – Touch to change current operating mode
6 Service – Stay up to date on system alarms and service alerts; touch to easily access service contact information
7 Status – Touch to view current operating status as well as runtime and cycle records
8 Inside Temperature Display – Displays current temperature
9 Settings – Touch to adjust several control settings, from humidity control to background color customization
Cancel
04 06 am
Oct. 20 2013
Accept
set the time and date
StatusSettings
heat set pointinside
Service HeatMode
72°
outside
72°Wed. Jan. 1, 6:00 am 55º
StatusSettings
heatinside cool
Service AutoMode
79°
outside
72°Wed. Jan. 1, 6:00 am 55º
StatusSettings
fan speed adjust
off
inside
Service FanOnlyMode
outside
72°Wed. Jan. 1, 6:00 am 55º
statusInside Temp: 80˚ Outside Temp: --˚
furnace ac/hp
Inside Rel. Humidity: 44%Thermostat Mode: offEquipment Operating status: off
basic
humidity schedules
Fan Speed: Auto
vacation
installer
time/date colors
settings
Heat Mode Auto Mode Fan Only Mode
Basic equipment settings to adjust
Control Center or equipment settings
Personalize background screen color
basic settings Follow Schedules ?Schedule Override TimeMain Screen Locked ?Alarm Beep Enable ?Auto-Changeover TimeSet Point DeadbandInside Temp Sensor OffsetTemperature Display
Yes2 hoursNoYes5 min.2˚ F-6.0˚ FFahrenheit
Morning:
CopyDay
Smooth Arrival Enabled
06:00 am 70˚ 78˚FanCoolHeatTime
Mon. Tue. Wed. Thu. Fri. Sat. Sun.
Auto
Day: 08:00 am 62˚ 85˚ Auto
Evening: 06:00 pm 70˚ 78˚ Auto
Night: 10:00 pm 62˚ 78˚ Auto
Edit the schedule by day/time
Vacation schedule
vacation
start: 12:00 pm Dec. 21 2013Jan. 01 201412:00 pmend:
Heat Cool Fan72˚ 80˚ Auto
EcoNetEnabled
VacationDisabled
background theme color
accept cancel
CC2 Translator
AC or HP
Select Water Heaters
U96V – 2-stage VSU97V – Modulating(U97V available Q4 2014)
EcoNet Control Center
WiFi Device Remote Access (Available Spring 2014)
Ruud EcoNet Air and Water System
StatusSettings
heat set pointinside
Service HeatMode
72°
Wed. Jan. 1 6:00 am outside
72°55º