49
© Intergraph 2014 The Power of Symbol Keys (SKEYs) Sonia Delgadillo

The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

Embed Size (px)

Citation preview

Page 1: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Sonia Delgadillo

Page 2: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Definable vs. Non-Definable Redefine ISOGEN Symbols SKEY Graphics Symbol Management Configure ISOGEN Questions

Page 3: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Understanding Symbol Keys Character Code Symbol Information Piping Component File (PCF) Spec Editor Configuration End Type Overwrite

Definable vs. Non-Definable Redefine ISOGEN Symbols SKEY Graphics Symbol Management Configure ISOGEN Questions

Page 4: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Understanding Symbol Keys

All components generated by ISOGEN are defined by unique symbol key referred to as SKEYS.

The Symbols Editor is supplied with CADWorx to allow users to quickly alter existing re-definable ISOGEN symbol key shapes (SKEYS) to meet their drawing annotation needs.

Page 5: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Character Code

SKEYS are defined by a 4 character code. The first two characters define the component type and the last two define the end type.

ISOGEN uses (**) to automatically assign predefined component end-types. The (**) allows CADWorx to assign end-types as predetermined by the CADWorx end connections and conditions.

ISOGEN component SKEYS allow default end-type definitions. In some cases an SKEY with component type VG** can be VGFL.

Component Type

End Type

SKEY

Gate Valve

**

VG**

Gate Valve

FL

VGFL

Page 6: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Information

An identifier is the component type An SKEY is a component symbol

Page 7: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Piping Component File (PCF)

The PCF file contains the definition for each component of it’s symbol and it’s associated end-types. ISOGEN uses this PCF definition to generate the isometric plot.

Page 8: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Spec Editor Configuration

By default the Identifier and the SKEY values will be blank. This indicates that CADWorx will handle ISOGEN symbol assignment.

Page 9: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

End Type Overwrite

The CADWorx ISOGEN Properties dialog provides End Connections and Conditions fields to allow users to overwrite the SKEYS end-types at each end point.

Page 10: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Definable vs. Non-Definable

User Definable Symbols Non User Definable Symbols Single Level Valves Multi Level Valves

Redefine ISOGEN Symbols SKEY Graphics Symbol Management Configure ISOGEN Questions

Page 11: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

User Definable Symbols

The following symbol categories can be redefined:

Page 12: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Non User Definable Symbols

The following symbol categories can not be redefined. Elbows Pulled Bends Tees Crosses

Page 13: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Single Level Valves

These identifiers can be redefined by changing the common shape that has been assigned to the SKEY.

Page 14: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Multi Level Valves

The SKEY for the VALVE-MULTIWAY will remain as shown below

Page 15: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Definable vs. Non-Definable Redefine ISOGEN Symbols

Symbol Editor Interface Symbol Workflow New Symbol Dialog Box

SKEY Graphics Symbol Management Configure ISOGEN Questions

Page 16: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Editor Interface

Page 17: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Editor Interface

Page 18: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Workflow

In the Library Explorer, select a component category or type If necessary, preview the symbols in the library explorer tree

To customize the symbol, Select Symbol > New Symbol Specify new SKEY name, if needed, copy graphics and choose spindle

Use the Edit Window to make changes to symbol Predefined start, exit, and spindle points are displayed A preview box displays the spindle and plotted isometric view Draw the symbol with the line, rectangle, and circle buttons

To save the redefined symbols Export the XML file The import option allows users to import other redefined symbols

For CADWorx isometrics use the Export ISOGEN Symbols option The Export ISOGEN Symbols creates a ASCII file

Associate the ASCII symbols file with Isometric Styles using I-Configure Create CADWorx isometrics using updated styles to see the results

Page 19: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

New Symbol Dialog Box

Specify a new SKEY name or overwrite existing SKEY Specify the new SKEY Description as needed The Original SKEY is a selection to choose the base symbol Specify the associated Spindle SKEY if applicable

The spindle option will only be available for valves Check Copy original symbol graphics as needed Click OK

Page 20: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Definable vs. Non-Definable Redefine ISOGEN Symbols SKEY Graphics

Best Practice New Symbol Points Tapping Points Tapping Rules Insulation & Tracing Properties Dialog SKEY Examples

Symbol Management Configure ISOGEN Questions

Page 21: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Best Practice

If the default SKEY uses ** for end-type then the user defined overwrite of that SKEY also has to use ** for the end-type. Otherwise two symbols could be applied to the VG SKEY (e.g. VGFL can be VG** or VGFL in the library)

User defined SKEY should not use the same SKEY already defined under a different component type.

Page 22: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

New Symbol Points

By default a new symbol will have the following 3 points defined Start Point Spindle End Point

Page 23: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Tapping Points

Tap Points are needed for connectivity in the isometric drawing. As a precaution it is recommended if you plan to connect CADWorx components to this component type then always add tap points.

Page 24: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Tapping Rules

The software allows you to place up to 9 tapping points according to the following rules. No more than 3 tapping points can be: On the vertical axis To the left of the vertical axis To the right of the vertical axis On the horizontal axis To the left of the horizontal axis To the right of the horizontal axis

Warning: The Symbol Editor will not warn you if they are located incorrectly. The Symbol Editor does not perform any rule-checking regarding tapping point placement.

Page 25: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Insulation & Tracing

ISOGEN Option Switch 61 and 62 must be turned on for Insulation and tracing to show on the isometric drawing :

Page 26: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Properties Dialog

In the Library Explorer, right-click an SKEY and view the symbol properties.

The property information for a system symbol is read-only and cannot be modified. System symbols appear as black text in the Library Explorer.

The property information for a redefined symbol can be modified. Redefined symbols appear as blue text in the Library Explorer.

Page 27: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples

Redefine Raised Face Weld Neck Redefine Flanged Filter Define Non Category Item Redefine Hanger Support

Page 28: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples

Overwrite Flange: Raised Face Weld Neck Redefine Filter Redefine Non-Category Item Redefine Support: Hanger

Page 29: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Raised Face Weld Neck

Permanently Overwrite Flange Symbol

Page 30: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Raised Face Weld Neck

Page 31: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Filter

Redefine Default Filter Symbol

Page 32: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Filter

Page 33: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Hanger Support

Redefine Default Non-Category Symbol

Page 34: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Non-Category Item

Page 35: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Hanger Support

Redefine Default Hanger Support Symbol

Page 36: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Examples:Redefine Hanger Support

Page 37: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Definable vs. Non-Definable Redefine ISOGEN Symbols SKEY Graphics Symbol Management

Symbol Library XML File

Export ISOGEN Symbols ASCII File

Configure ISOGEN Questions

Page 38: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Library

Symbols can be saved to an XML library. If any customized symbols exist in the imported symbol library, the component group and component type labels display in blue text.

Page 39: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Symbol Library: XML File

Page 40: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Export ISOGEN Symbols

Symbols that you create with Symbol Editor must be exported to an XML- or ASCII-based file. These symbol libraries can, in turn, be imported into Symbol Editor so that individual symbols can be modified and then saved. To use any symbols that you define in Symbol Editor on an isometric drawing generated in a third party 3D design tool, they must be exported to an ISOGEN ASCII symbol file.

Page 41: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Export ISOGEN Symbols: ASCII File

Page 42: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Definable vs. Non-Definable Redefine ISOGEN Symbols SKEY Graphics Symbol Management Configure ISOGEN

Assign the ASCII symbols file to the ISOGEN Isometric Style Tie ISOGEN ASCII symbols file to CADWorx component ISOGEN generates Isometric drawing with custom symbols

Questions

Page 43: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Assign the ASCII symbols file to the ISOGEN Isometric Style

I-Configure allows users to create and manage the isometric directories, projects and styles that are used by CADWorx to generate isometric drawing and report outputs.

Map the ASCII Symbols file. Remember to export style.

Page 44: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Assign the ASCII symbols file to the ISOGEN Isometric Style

Page 45: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Tie ISOGEN ASCII symbols file to CADWorx component

Add User Defined SKEY to the Specification Project or add to the CADWorx component in the model.

Page 46: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Tie ISOGEN ASCII symbols file to CADWorx component

Page 47: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

ISOGEN generates Isometric drawing with custom symbols

Page 48: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

The Power of Symbol Keys (SKEYs)

Overview Definable vs. Non-Definable Redefine ISOGEN Symbols SKEY Graphics Symbol Management Configure ISOGEN Questions

Page 49: The Power of Symbol Keys (SKEYs) - · PDF file · 2014-04-272014-04-27 · The Power of Symbol Keys (SKEYs) ... ISOGEN uses (**) to automatically assign predefined component end-types

© Intergraph 2014

Thank you

Questions