9
PROJECT DESCRIPTION MAJOR OCCUPANCY(S) 1 2 3/4 5 6 NUMBER OF STOREYS AREA (m ) 2 NUMBER OF STREETS/ FIRE FIGHTER ACCESS 7 BLDG CLASSIFICATION 8 SELECTED FLOOR AREAS SELECTED COMPARTMENTS BASEMENT ENTIRE BLDG SPRINKLER SYSTEM PROPOSED ADDITION NEW CHANGE OF USE ALTERATION PART 3 ONTARIO BUILDING CODE MATRIX PART 9 PART 11 1.1.2. [A] &9.10.1.3 9.10.2 3.1.2.1.(1) PART 3 PART 9 BUILDING AREA: EXISTING= NEW= TOTAL= TOTAL= GROSS AREA: NEW= EXISTING= 1.4.1.2. [A] 1.4.1.2. [A] 3.2.1.1 & 1.4.1.2. [A] 9.10.20. & 1.4.1.2. [A] 3.2.2.10 & 3.2.5 3.2.2.20-83 9.10.2 3.2.2.20-83 3.2.1.5 3.2.2.17 INDEX 9.10.8.2 INDEX 9 STANDPIPE REQUIRED YES NO ABOVE GRADE: BELOW GRADE: 10 FIRE ALARM REQ'D YES NO 11 YES NO WATER SERVICE/ SUPPLY IS ADEQUATE 12 HIGH BUILDING YES NO CONSTRUCTION TYPE 13 COMBUSTIBLE PERMITTED NON-COMBUSTIBLE REQ'D PERMITTED CONSTR. BOTH NON-COMBUSTIBLE COMBUSTIBLE ACTUAL CONSTR. BOTH MEZZANINE(S) AREA (m ) 2 14 OCCUPANT LOAD 15 BASED ON: m /PERSON DESIGN OF BUILDING 2 BASEMENT: 1ST FLOOR: 2ND FLOOR: 3RD FLOOR: BARRIER-FREE DESIGN 16 YES HAZARDOUS SUBSTANCES 17 YES NO 3.3.1.2. & 3.3.1.19 9.10.1.3.(4) 3.8 9.5.2 3.1.17 9.9.1.3 9.10.4.1 3.2.1.1.(3-8) 3.2.2.20-83 9.10.6 3.2.6 3.2.4 9.10.18 3.2.9 REQUIRED FIRE RESISTANCE RATING (FRR) 18 HORIZONTAL ASSEMBLIES FLOORS: ROOF: MEZZANINE: HRS HRS HRS SUPPORTING MEMBERS LISTED DESIGN NO. OR DESCRIPTION (SG-2) MEZZANINE: FLOORS: ROOF: HRS HRS HRS 3.2.2.20-83 3.2.1.4 9.10.8 9.10.9 19 SPATIAL SEPARATION -- CONSTRUCTION OF EXTERIOR WALLS 3.2.3 9.10.14 WALL AREA OF EBF (m ) 2 L.D. (m) L/H OR H/L PERMITTED MAX. % OF OPENINGS FRR (HOURS) LISTED DESIGN OR DESCRIPTION COMB. CONSTR. NONCOMB. CLADDING NON- COMB. CONSTR. NO (EXPLAIN) NORTH SOUTH EAST WEST COMB. CONSTR. PROPOSED MAX. % OF OPENINGS LISTED DESIGN NO. OR DESCRIPTION (SG-2) NAME OF PROJECT: LOCATION: 63 PAMILLA STREET OTTAWA ON K1S 3K7 CONTACT: BARRY J HOBIN 238-7200 1.1.2. [A] 9.10.20 IN LIEU OF ROOF RATING NOT REQUIRED N/A 3.2.5.7 N/A N/A OCCUPANCY: OCCUPANCY: OCCUPANCY: OCCUPANCY: LOAD ____ PERSONS LOAD ____ PERSONS LOAD ____ PERSONS LOAD ____ PERSONS 0.00 m² 865.00 m² 865.00 m² 0.00 m² 1179.00 m² 1179.00 m² 0.00 m² 2 1 2 STREETS 3.2.2.25 0HR N-COMB N-COMB N/A GROUP A,, DIVION 2 - ASSEMBLY 602 106 455 SQ.M. 501 SQ.M. 208 SQ.M. COMP-A PARKING LEVEL 36 SQ.M. COMP-B LEVEL 1 92SQ.M. COMP-C LEVEL 101 SQ.M. 1.2 m 4.9 7 % 6 % 1HR 1HR 1HR 45HR THE OTTAWA CHINESE ALLIANCE CHURCH 22 ECCLES, OTTAWA, ON. 2 m 4.9 7 % 2 % 7.4 m 1.9 20 % 2 % 5.047 m 4.1 55.8% 31 % 45HR 5.047 m 4.6 27.4% 22 % 45HR 5.047 m 4.6 25.2% 22 % note: refer to OBC 3.2.3.7 - 4a for permitted non combustible cladding. N-COMB N-COMB COMB COMB COMB COMB Email: [email protected] 613-238-7200 Fax: 613-235-2005 63 PAMILLA STREET OTTAWA, ONT. K1S 3K7 revision date no. All contractors must comply with all or omissions to the engineer. sions on site and report all errors and/ It is the responsibility of the appropriate contractor to check and verify all dimen- Copyright reserved. construction until signed. This drawing may not be used for Do not scale drawings. DRAWING TITLE PROJECT REVISION NO. DRAWING NO. PROJECT SCALE DATE DRAWN 1 : 20 1 Author 10/17/14 1307 A0.00 TITLE SHEET The Ottawa Chinese Alliance Church 22 Eccles, Ottawa, ON. SCALE: 1 : 20 A0.00 1 OCAC CODE MATRIX Sheet List A0.00 TITLE SHEET 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A1.00 SITE PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A1.01 CONSTRUCTION ASSEMBLIES A1.20 SITE DETAILS A1.50 EXISTING BUILDING PARKING & LEVEL 1 DEMO A2.00 LEVEL 0 - PARKING LEVEL 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A2.01 LEVEL 1 FLOOR PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A2.02 LEVEL 2 FLOOR PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A2.03 ROOF PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A2.11 REFLECTED CEILING PLAN - LEVEL 1 A2.12 REFLECTED CEILING PLAN - LEVEL 2 A2.20 FOUNDATION PLAN A2.30 LEVEL 0 - PARKING LEVEL SLAB EDGE PLAN A2.31 LEVEL 1 SLAB EDGE PLAN A2.32 LEVEL 2 SLAB EDGE PLAN A2.40 PLAN BLOW UPS A3.01 ELEVATIONS 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A3.02 ELEVATIONS 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A4.01 BUILDING SECTIONS 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL A4.10 WALL SECTIONS A4.11 WALL SECTIONS A4.12 WALL SECTIONS A4.13 WALL SECTIONS A6.01 PLAN DETAILS THE OTTAWA CHINESE ALLIANCE CHURCH 22 ECCLES , OTTAWA, ONTARIO 1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

THE OTTAWA CHINESE ALLIANCE CHURCH

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

PROJECT DESCRIPTION

MAJOR OCCUPANCY(S)

1

2

3/4

5

6

NUMBER OF STOREYS

AREA (m ) 2

NUMBER OF STREETS/FIRE FIGHTER ACCESS

7 BLDG CLASSIFICATION

8SELECTED FLOOR AREAS

SELECTED COMPARTMENTS

BASEMENT

ENTIRE BLDGSPRINKLER SYSTEMPROPOSED

ADDITIONNEW CHANGE OF USEALTERATION

PART 3

ONTARIO BUILDING CODE MATRIX

PART 9 PART 11

1.1.2. [A]&9.10.1.3

9.10.23.1.2.1.(1)

PART 3 PART 9

BUILDING AREA:EXISTING=NEW=

TOTAL= TOTAL=

GROSS AREA:

NEW=EXISTING=

1.4.1.2. [A] 1.4.1.2. [A]

3.2.1.1 &1.4.1.2. [A]

9.10.20. &1.4.1.2. [A]

3.2.2.10 &3.2.5

3.2.2.20-83 9.10.2

3.2.2.20-833.2.1.5

3.2.2.17INDEX

9.10.8.2INDEX

9 STANDPIPE REQUIRED YES NO

ABOVE GRADE: BELOW GRADE:

10 FIRE ALARM REQ'D YES NO

11YES NO

WATER SERVICE/ SUPPLYIS ADEQUATE

12 HIGH BUILDING YES NO

CONSTRUCTION TYPE13COMBUSTIBLE PERMITTED

NON-COMBUSTIBLE REQ'D

PERMITTED CONSTR.

BOTH

NON-COMBUSTIBLE

COMBUSTIBLE

ACTUAL CONSTR.

BOTH

MEZZANINE(S) AREA (m ) 214

OCCUPANT LOAD15 BASED ON: m /PERSON DESIGN OF BUILDING2

BASEMENT:

1ST FLOOR:

2ND FLOOR:

3RD FLOOR:

BARRIER-FREE DESIGN16YES

HAZARDOUS SUBSTANCES17 YES NO3.3.1.2. &3.3.1.19 9.10.1.3.(4)

3.8 9.5.2

3.1.17 9.9.1.3

9.10.4.13.2.1.1.(3-8)

3.2.2.20-83 9.10.6

3.2.6

3.2.4 9.10.18

3.2.9

REQUIRED FIRERESISTANCE RATING (FRR)

18 HORIZONTAL ASSEMBLIES

FLOORS:

ROOF:

MEZZANINE: HRS

HRS

HRS

SUPPORTING MEMBERS

LISTED DESIGN NO. ORDESCRIPTION (SG-2)

MEZZANINE:

FLOORS:

ROOF:

HRS

HRS

HRS

3.2.2.20-833.2.1.4

9.10.89.10.9

19 SPATIAL SEPARATION -- CONSTRUCTION OF EXTERIOR WALLS 3.2.3 9.10.14

WALL AREA OF EBF(m ) 2

L.D.(m)

L/HORH/L

PERMITTEDMAX. % OFOPENINGS

FRR(HOURS)

LISTEDDESIGN OR

DESCRIPTION CO

MB.

CO

NST

R.

NO

NC

OM

B.C

LAD

DIN

G

NO

N- C

OM

B.C

ON

STR

.

NO (EXPLAIN)

NORTH

SOUTH

EAST

WEST

CO

MB.

CO

NST

R.

PROPOSEDMAX. % OFOPENINGS

LISTED DESIGN NO. ORDESCRIPTION (SG-2)

NAME OF PROJECT:

LOCATION:

63 PAMILLA STREETOTTAWA ONK1S 3K7CONTACT: BARRY J HOBIN 238-7200

1.1.2. [A]

9.10.20

IN LIEU OF ROOF RATINGNOT REQUIRED

N/A

3.2.5.7 N/A

N/A

OCCUPANCY:

OCCUPANCY:

OCCUPANCY:

OCCUPANCY:

LOAD ____ PERSONS

LOAD ____ PERSONS

LOAD ____ PERSONS

LOAD ____ PERSONS

0.00 m²865.00 m²865.00 m²

0.00 m²1179.00 m²1179.00 m²

0.00 m²

2 1

2 STREETS

3.2.2.25

0HR

N-COMBN-COMBN/A

GROUP A,, DIVION 2 - ASSEMBLY

602106

455 SQ.M.501 SQ.M.208 SQ.M.COMP-APARKING LEVEL36 SQ.M.

COMP-BLEVEL 192SQ.M.

COMP-CLEVEL101 SQ.M.

1.2 m 4.9 7 % 6 % 1HR1HR1HR45HR

THE OTTAWA CHINESE ALLIANCE CHURCH

22 ECCLES, OTTAWA, ON.

2 m 4.9 7 % 2 %7.4 m 1.9 20 % 2 %5.047 m 4.1 55.8% 31 %

45HR5.047 m 4.6 27.4% 22 %

45HR5.047 m 4.6 25.2% 22 %

note: refer to OBC 3.2.3.7 - 4afor permitted non combustiblecladding.

N-COMBN-COMBCOMBCOMB

COMB

COMB

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 : 20

1

Author 10/17/14

1307

A0.00

TITLE SHEET

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 20A0.001 OCAC CODE MATRIX

Sheet List

A0.00 TITLE SHEET 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA1.00 SITE PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA1.01 CONSTRUCTION ASSEMBLIESA1.20 SITE DETAILSA1.50 EXISTING BUILDING PARKING & LEVEL 1

DEMOA2.00 LEVEL 0 - PARKING LEVEL 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA2.01 LEVEL 1 FLOOR PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA2.02 LEVEL 2 FLOOR PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA2.03 ROOF PLAN 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA2.11 REFLECTED CEILING PLAN - LEVEL 1A2.12 REFLECTED CEILING PLAN - LEVEL 2A2.20 FOUNDATION PLANA2.30 LEVEL 0 - PARKING LEVEL SLAB EDGE PLANA2.31 LEVEL 1 SLAB EDGE PLANA2.32 LEVEL 2 SLAB EDGE PLANA2.40 PLAN BLOW UPSA3.01 ELEVATIONS 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA3.02 ELEVATIONS 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA4.01 BUILDING SECTIONS 1 2014.11.26 ISSUED FOR SITE PLAN CONTROLA4.10 WALL SECTIONSA4.11 WALL SECTIONSA4.12 WALL SECTIONSA4.13 WALL SECTIONSA6.01 PLAN DETAILS

THE OTTAWA CHINESE ALLIANCE CHURCH22 ECCLES , OTTAWA, ONTARIO

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

UP

UP

DN

DNNEW STORAGE

X003

STAIRX002 69604

EXISTING OPEN AIR GARAGE ENTRANCE

NEW UNDERGROUNDPARKING ENTRANCE

DC

EXISTING TWO STOREY BUILDINGTHE OTTAWA CHINESE ALLIANCE CHURCH

22 ECCLESZONING - I1A

24 PARKING SPACES IN EXISTINGOPEN AIR GARAGE

7.5mINTERIOR SIDE YARD SETBACK

1.0 mINTERIOR SIDE YARD SETBACK

2.0 mINTERIOR SIDE YARD SETBACK

3.5 mINTERIOR SIDE YARD

SETBACK

2.0

mFR

ON

T YA

RD S

ETB

ACK

46.3

32 m

23°

29'

20"

43.607 m 66° 23' 49" 43.592 m 66° 24' 45"

23.1

55 m

23°

29'

36"

43.589 m 66° 24' 45"

23.1

6 5 m

23 °

29 '

05 "

43.610 m 66° 24' 45"SMH

CBI

UP UP

CBI

UP

CBI

CB

CB

CB

CB

CB

FH

CBI

CBI

BMH

CBI

3000

3000

CB

B

BB

B

ECCLES STREET

LEBR

ETO

N S

TREE

T

BELL

STR

EET

75

00

10

00

2000

20

00

EXISTINGTWO STOREYRESIDENTIAL

BUILDINGEXISTING

TWO STOREYRESIDENTIAL BUILDING

EXISTINGTWO STOREY

RESIDENTIAL BUILDINGEXISTING

ONE STOREYGARAGE

EXISTINGTWO STOREY

RESIDENTIAL BUILDING

EXISTINGTWO STOREY

RESIDENTIAL BUILDING

EXISTINGTWO STOREYRESIDENTIAL

BUILDING

EXISTINGTWO STOREYRESIDENTIAL

BUILDING

EXISTINGONE STOREY

GARAGE

EXISTINGSTRUCTURE

TO BE DEMOLISHED

EXISTINGSTRUCTURE

TO BEDEMOLISHED

EXISTINGGARAGE

STRUCTURETO BE

DEMOLISHED

EXISTING GARAGESTRUCTURE

TO BE DEMOLISHED

EXISTING RAMP

EXISTING TREESTO BE REMOVED -REFERTO SURVEY FOR TREE SIZE

EXISTING TREESTO BE REMOVED -REFER TO SURVEY

FOR TREE SIZE

EXISTING TREESTO BE REMOVED -REFER TO SURVEYFOR TREE SIZE

CANOPYABOVE

EXTE

NT

OF

CAN

OPY

35200

2043

19

09

3

CANOPY ABOVE

POURED CONC.RETAINING WALL

NEW 2 STOREY BUILDING+ UNDERGROUND PARKING

GARAGEZONING: I1A [1969]

EXISTING RETAINING WALL TO BEDEMOLISHED & REBUILTALONGPROPERTY LINE

EXISTING CURBTO BE REMOVED

NEW 7' HIGHWOOD FENCE

PLANTING BED

UNITPAVEVRS

EXISTING VEHICLEPARKING ENTRANCE

EXISTINGMAIN ENTRANCE

NEWVEHICLE ENTRANCE

EXISTINGTREE

EXISTINGTREES TO BEREMOVED

EXISTINGTREE

EXISTING

TREE

EXISTING TREEEXISTING TREE

15

0

EXISTING PARKINGAREA TO BE

DEMOLISHED

PLANTING BED

NEW UNITPAVEVRS

PLANTINGBED

EXISTINGRETAINING

WALL TO BEDEMOLISHED

DC

LIM

ITIN

GD

ISTA

NCE

LIMITINGDISTANCE

NEW

EXI

T

NEW EXIT

LOOSE LAIDCONCRETE MASONRYUNIT RETAINING WALL

LOOSE LAIDCONCRETE

MASONRY UNITRETAINING WALL

WOODSCREEN

EXTENT OFZONING

GATE

GATE

1 2 3 4 5 6 7 8 9 10 11 12 13 14

15

16

17

18

19

20

21

ZONINGR4H

ZONINGR4H

3641

21 20 19 18 17 1615 14 13

1211

9

10

242322

1 2 3 4 5 6

8

7

5057

BFP

FR

FR

FIRE

RO

UTE

FIRE ROUTE

FR FR FR

UNIT PAVEVRS

CURB LOCATED@ WHEEL STOP

NEW 7' HIGHWOOD FENCE

NEW 7' HIGHWOOD FENCE

NEW 7' HIGHWOOD FENCE

EXTENT OF NEWADDITION

GUARD

FIRE ROUTE

FIRE ROUTE

TEXISTINGTRANSFORMER PAD

1A1.20

ENTRY LEVELEL. 72.100

LEVEL 1 EL. 73.000

EXISTING PARKING LEVEL - EL. 69.604EXISTING GROUND LEVEL - EL. 72.041

3000 26002400260024002600240026002400260024002600240026002400

67

06

52

00

NEWTRANSFORMER

PLANTING

11

00

GROUNDING LOOP

EXISTINGTREE TO BEREMOVED

26

00

26

00

26

00

26

00

26

00

26

00

35

97

EXISTING MAN HOLE

EXISTING BELL MAN HOLE

EXISTING SANITARY MAN HOLE

EXISTING FIRE HYDRANT

EXISTING CATCH BASIN

EXISTING CATCH BASIN INLET

EXISTING UTILITY POLE

MH

BMH

SMH

FH

CB

CBI

UP

EXISTING BUILDING

NEW BUILDING

TREES TO BE REMOVED

EXISTING TREES TO BE RETAINED

BARRIER FREE PARKING SIGNAGEBFP

FIRE ROUTE SIGNAGEFR

EXISTING DEPRESSED CURB

NEW DEPRESSED CURB

UNIT PAVERS

0 5 10 mFIRE ROUTE

EXTISTING BUILDING DATA

PROPSOED BUILDING DATA

ZONING I1A

ZONING I1A [1969]

BUILDING AREABUILDING GFA

853 sq.m.Level 1 gfa 853 sq.m.Level 2 gfa 484 sq.m.Total gfa 1,337 sq.m.

BUILDING AREABUILDING GFA

870 sq.m.

Level 1 gfa 696 sq.m.Level 2 gfa 258 sq.m.Total gfa 968 sq.m.

Parking level gfa 14 sq.m.

SETBACKS & HEIGHTS FRONT YARDNORTH SIDE YARD

REAR YARDMAX. HEIGHT

2m2m

0m11m

3.5m after 35.2mSOUTH SIDE YARD 1m

REQ. PROPOSED2m2m

0m10.8m

3.5m after 35.2m1m

EXISTING PARKING SPACES

NEW PARKING SPACES

-PARKING REQUIREMENTSAS PER PLANNINGCOMMITTEE REPORT OCT24th, 2012 PAGE 76, 2-e

73 SPACES

REQUIRED

25 SPACES

PROPOSED

28 SPACES

PARKING REQUIREMENTS

INTERIORSURFACE PARKING 27 SPACES

21 SPACES21 SPACES24 SPACES

73 SPACES

STOREYS 2

TOTAL SITE AREA: 32610 sq.m.

LEGAL DESCRIPTION: LOTS 11 AND 12ANDPART OF LOTS 9 AND 10REGISTERED PLAN 4908CITY OF OTTAWA

INT. PARKING GARAGE

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

As indicated

1

PB 09/30/14

1307

A1.00

SITE PLAN

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 150A1.001 SITE PLAN

SCALE: 1 : 100A1.002 NEW BUILDING DATA

SITE PLAN LEGEND

OWNER:THE OTTAWA CHINESE ALLIANCE CHURCH22 ECCLESOTTAWA, ONTEL: 613-235-8187

CONSULTANTS:

SURVEYOR:ANNIS O'SULLIVAN VOLLEBECKK14 CONCOURSE GATE, SUITE 500NEPEAN, ON.TEL: 613-727-0850

CIVIL:DOUGLAS GRAYD.B. GRAY ENGINEERING1052 Karsh Dr, Ottawa, ON K1G 4N1TEL:613-249-8044

LANDSCAPE:RUDY LEVSTEKLAROCQUE LEVSTEK LANDSCAPE ARCHITECTS5871 HUGH CRESCENTOSGOOD, ONTEL:613-826-0518

GEOTECHNICAL:LUC BOUCHARDHOULE CHEVRIER180 WESCAR LANE, P.R.2CARP, ON.613-836-1422

STRUCTURAL ENGINEER:RICK CUNLIFFECUNLIFFE & ASSOCIATES1737 WOODWARD DRIVE, SUITE 102OTTAWA, ON.TEL:613-729-7242

M&E ENGINEER:QUANDRANT ENGINEERING107 PRETORIA AVE.OTTAWA, ON.TEL:613-567-1487

NOTE: ALL EXISTING SITE INFORMATION ASPER SITE SURVEY PLAN DATED 04/09/2014AND PREPARED BY "ANNIS O'SULLIVANVOLLEBECKK"

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

DN

UP

UP

A3.01

1

A3.012A3.02 2

A3.02

1

1 1

B

B

C

C

D

D

E

E

F

F

H

H

33

44

Cx

Cx

5x 5x

Dx

Dx

Ex

Ex

5y 5y

UNDERGROUNDPARKING

A008

VEST.A002

ELEC. CLOSETA003

ELEV. LOBBYA004

MECHANICALROOMA006

FD

STAIRA001

67

00

E.M.R.A005

800 1200 2280 1550 4070 3640 4260 4730 3170 6360 1540 8800

18

60

32

80

15

57

48

50

18

50

42

30

12

00

88

0

30

23

02

001

002003004

007

1

A4.01

2

A4.01

3

A4.01

2100

18

27

006

005

1 2 3 4 5 6 7 8 9 10 11 12 13 14

15 16 17

1819

202122232425262728

CHAIN LINK FENCE STORAGE ENCLOSURE4731 4731 4731 4731 4731

STOR. STOR. STOR. STOR. STOR.

12

00

300

12

00

300

12

00

300

12

00

12

00

12

00

12

00

12

00

67

37

2600 2600150 150

2600 2400 2600150 150

2600 2400 2600150 150

2600 2400 2600150 150

2600 2400 2600150 150

2600 2950 2600 250

ø 1500

2

A4.10

1

A4.10

69800

69925

70200

70225

66

97

67

00

42

30

20

80

FD FD

FD

FD

150 2600 2400 2600 150 150 2600 2400 2600150 150

2600 2400 2600 1950 2400 2600

52

00

52

00

1A2.40

2A6.01

A'

A'

Ax

Ax

Ay

Ay

Bx

Bx

By

By

3x3x

G

G

2y

5 5

A

A

22

23

0

20

20

230

2x

69150

69900

69550

69780

69900

30

26

09

63

02

1A6.01

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 : 75

1

Author 10/01/14

1307

A2.00

LEVEL 0 - PARKING LEVEL

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 75A2.001 PARKING LEVEL FLOOR PLAN

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

UP

UP

DN

DN

DN

DN

DN

A3.01

1

A3.012A3.02 2

A3.02

1

1 1

B

B

C

C

D

D

E

E

F

F

H

H

33

44

Cx

Cx

5x 5x

Dx

Dx

Ex

Ex

5y 5y

WORSHIPMULTI-PURPOSE

A108

STOR.A112

STOR.A111

STAGINGA110

KITCHENA106

MEN'S W/CA105

STOR.A115

WOMEN'S W/CA104

COATSA101

STOR.A113STAIR 1

A107JAN.A102

FOYERA103

A.V. HUBA108a

STAGEA108b

VESTIBULEA100

VESTIBULEA100a

ELEV. LOBBYA114

951

61

3

HALLA103a

820 3580 800 1200 2280 1550 4070 3640 4260 4730 3170 6360 1540 7040 1760

100

100a

104 105

115

106

106a

107

113a

118

109 110

111

112

108

110a 108STAIR 2

A118

STOR.A109

107a

1

A4.01

1

A4.01

2

A4.01

3

A4.01

0

18

27

16

78

5

26789 1791

102

12

00

82

5

11

65

73000

60

0

60

0

1151

ø 1500

ø 1500

ø 1500

40

0

2

A4.10

7354073000

1

A4.10

820 3580 800 1200 2280 1550 4070 3640 4260 4730 3170 6360 1540 7040 1760

18

60

32

80

15

57

48

50

18

50

42

30

12

00

88

0

18

60

34

62

13

75

48

50

18

50

42

30

12

00

88

0

73000

72100

72100

EQEQ

EQEQ

9076

45

75

29'-9" x 15'-0"RETRACTABLE STAGE

2A2.40

A'

A'

Ax

Ax

Ay

Ay

1200

Bx

Bx

By

By

3x3x

18

50

106h

G

G

EXHAUST SHAFT

2y

STOR.A116

116

5 5

A

A

22

2x

13

75

108f

108e

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 : 75

1

PB 10/01/14

1307

A2.01

LEVEL 1 FLOOR PLAN

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 75A2.011 LEVEL 1 FLOOR PLAN

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

DN

DN

A3.01

1

A3.012A3.02 2

A3.02

1

1 1

B

B

C

C

D

D

E

E

F

F

H

H

33

44

Cx

Cx

5x 5x

Dx

Dx

Ex

Ex

5y 5y

MULTI-PURPOSEROOMA202

MULTI-PURPOSEROOMA204

MULTI-PURPOSEROOMA210

MULTI-PURPOSEROOMA211

MULTI-PURPOSEROOMA206

MULTI-PURPOSEROOMA205JAN.

A201

ROOF ACCESSA209

LOBBYA200

CORRIDORA203

WCA207

WCA208

18

30

1132

1830

209

1100

7900 3640 4260 4730 3170 6360 1540 8800

202 204

205

206

211210

209

208

207

201 STAIRA213

RoomA212

212

213

1

A4.01

2

A4.01

3

A4.01

CANOPY BELOW

CANOPY BELOW

CANOPY BELOW

18

89

2099

300300

2

A4.10

1

A4.10

OPEN TO BELOW

7900 3640 4260 4730 3170 6360 1540 8800

66

97

67

00

42

30

20

80

66

97

67

00

42

30

20

80

A'

A'

Ax

Ax

Ay

Ay

Bx

Bx

By

By

3x3x

G

G

2y

5 5

A

A

22

2x

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 : 75

1

PB 10/01/14

1307

A2.02

LEVEL 2 FLOOR PLAN

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 75A2.021 LEVEL 2 FLOOR PLAN

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

DN

A3.01

1

A3.012A3.02 2

A3.02

1

1 1

B

C

C

D

D

E

E

F

F

H

H

33

44

Cx

Cx

5x 5x

Dx

Dx

Ex

Ex

5y 5y

RD

RD

7900 3640 4260 4730 3170 6360 1540 8800

CANOPY BELOW

CANOPY BELOW

1

A4.01

2

A4.01

3

A4.01

Roof hatch

2

A4.10

1

A4.10

PROJECTING BROWBELOW

7900 3640 4260 4730 3170 6360 1540 8800

66

97

67

00

42

30

20

80

66

97

67

00

42

30

20

80

RD

92

59

7683

92

59

7733

82

64

7239

A' Ax Ay Bx By

3x3x

G

G

2y

5 5

A

22

2x

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 :75

1

PB 10/02/14

1307

A2.03

ROOF PLAN

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 :75A2.031 ROOF PLAN

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

LEVEL 1

73.00

LEVEL 1

73.00

Level 2

77.30

Level 2

77.30

PARKING LEVEL

69.90

PARKING LEVEL

69.90

ENTRANCE LEVEL

72.10 ENTRANCE LEVEL

72.10

LOW ROOF

80.95

LOW ROOF

80.95

HIGH ROOF

82.61

HIGH ROOF

82.61

BCDEFH CxDxEx

33

50

16

50

CCP

PCA

PHWS

PFM

WSC

SC

PC

PHWS SWS

PCA ? SC

CCP

1000 2600

R 5000

CCP

PFM96

10

PFMPFMPFM

A'AxAyBxByG A

22

00

90

04

30

03

65

01

66

0

LEVEL 1

73.00

Level 2

77.30

PARKING LEVEL

69.90

ENTRANCE LEVEL

72.10

LOW ROOF

80.95

HIGH ROOF

82.61

1345x5y

904

PHWS CCP

CCP

CCP

WSC

SC

PFM

PC

16

60

36

50

43

00

90

02

20

0

68

0

2080 4230 6700 6697

1

A4.01

108

PFM

PFM

3x 2y5 22x

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 : 100

1

PB 10/09/14

1307

A3.01

ELEVATIONS

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 100A3.011 NORTH ELEVATION

SCALE: 1 : 100A3.012 EAST ELEVATION

SCALE:A3.013 VIEW FROM NORTH EAST

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

LEVEL 1

73.00

Level 2

77.30

PARKING LEVEL

69.90

ENTRANCE LEVEL

72.10

LOW ROOF

80.95

HIGH ROOF

82.61

B C D E F HCx Dx Ex

PHWSCCP

CCP

SWS

PCA

PCA

PCA PHWS

PFM

61

0

41

0

118

R 5000

PFMPFM

PFMPFM

A' Ax Ay Bx By GA

LEVEL 1

73.00

Level 2

77.30

PARKING LEVEL

69.90

ENTRANCE LEVEL

72.10

LOW ROOF

80.95

HIGH ROOF

82.61

1 3 4 5x 5y

19

41

20

3

30

70

61

5

12

20

65

2

1

A4.01

CCP

PCA

CCP

PCA

CCP

PC007

100

107a

PFM

PFM

PFM

3x2y 52 2x

16

60

36

50

43

00

90

02

20

0

16141

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 : 100

1

PB 10/09/14

1307

A3.02

ELEVATIONS

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 100A3.021 SOUTH ELEVATION

SCALE: 1 : 100A3.022 WEST ELEVATION

SCALE:A3.023 VIEW FROM SOUTH WEST

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL

LEVEL 1

73.00

Level 2

77.30

PARKING LEVEL

69.90

ENTRANCE LEVEL

72.10

LOW ROOF

80.95

HIGH ROOF

82.61

B C D E F HCx Dx Ex

2

A4.01

MULTI-PURPOSEROOMA206

CORRIDORA203

WCA208

MULTI-PURPOSEROOMA204

MULTI-PURPOSEROOMA202

VESTIBULEA100a

FOYERA103

UNDERGROUNDPARKING

A008

16

60

36

50

43

00

90

02

20

0

88001540636031704730426036407900

61

0

60

0

2

A4.10

A' Ax Ay Bx By GA

LEVEL 1

73.00

Level 2

77.30

PARKING LEVEL

69.90

ENTRANCE LEVEL

72.10

LOW ROOF

80.95

HIGH ROOF

82.61

1 3 4 5x 5y

1

A4.013

A4.01

83

97

UNDERGROUNDPARKING

A008

STAGINGA110

16

60

36

50

43

00

90

02

20

0 31

00

197076697 6700 4230

20

0

31

00

12

00

3x2y 52

LEVEL 1

73.00

Level 2

77.30

PARKING LEVEL

69.90

ENTRANCE LEVEL

72.10

LOW ROOF

80.95

HIGH ROOF

82.61

B C DCx Dx

2

A4.01

16

60

36

50

43

00

90

02

20

031

00UNDERGROUND

PARKINGA008

36407900

946

27

50

2

A4.10

OVERHEAD DOOR

19

81

A' Ax Ay Bx ByA

Email: [email protected] Fax: 613-235-2005

63 PAMILLA STREETOTTAWA, ONT. K1S 3K7

revisiondateno.

All contractors must comply with all

or omissions to the engineer.sions on site and report all errors and/

It is the responsibility of the appropriatecontractor to check and verify all dimen-

Copyright reserved.

construction until signed.This drawing may not be used for

Do not scale drawings.

DRAWING TITLE

PROJECT

REVISION NO.

DRAWING NO.

PROJECT

SCALEDATEDRAWN

1 : 75

1

PB 10/15/14

1307

A4.01

BUILDING SECTIONS

The Ottawa ChineseAlliance Church

22 Eccles, Ottawa, ON.

SCALE: 1 : 75A4.011 BUILDING SECTION

SCALE: 1 : 75A4.012 BUILDING SECTION

SCALE: 1 : 75A4.013 BUILDING SECTION

1 2014.11.26 ISSUED FOR SITE PLAN CONTROL