2
The Original All-in-One Veterinary Digital Radiography Solution KONICA MINOLTA MEDICAL IMAGING USA, INC. 411 NEWARK POMPTON TURNPIKE WAYNE, NJ 07470 TEL: (973) 633-1500 FAX: (973) 633-0562 WEBSITE: medical.konicaminolta.us ©2011 Konica Minolta KMMI-IP_Vet/11 ImagePilot Features and Specifications* Hardware Components (specifications vary with each ImagePilot model) Imaging Station (specification ranges) Platform Desktop or Tower Drive Capacity 250GB (single drive) to 2TB RAID 5 (3x1TB) RAM 2GB to 4GB Display 19” to 24” . Available in resolutions up to 3MP CD/DVD Read/Write capability REGIUS 110 Series CR Reader Throughput (14x17) 40 cassettes per hour (REGIUS 110S) 60 cassettes per hour (REGIUS 110) 76 cassettes per hour upgrade (REGIUS 110) Grayscale 12 bit Outer dimensions W29.1” x D14.4” x H29.4” Weight 220 lbs Backup or Extended Storage NAS 2TB RAID 5, 4TB RAID 5 DVD Back-up tool Manual or scheduled back-up to DVD Software Features (features vary with each model) Patient Registration Manual data entry or through work-list provider (DICOM or HL7) Image Acquisition REGIUS 110 or 110S CR Reader Import Images from CD/DVD, USB or folder – DICOM, PDF or JPEG Acquires images from other DICOM modalities Basic Viewing Tools Window / Level, Viewing Size, Invert, Magnifier, Rotate/Flip Standard Annotation Tools Line, Arrow, Free Form, Rectangle, Polygon, Ellipse, Closed Free Form Free Text and Preset Markers Standard Measurement Tools Distance, Angle, Cardio Index, Cobb Angle, Pelvis Analysis, Rectangular Area, Elliptical Area, Polygonal Area, Rectangular CT Image Output Export images to media (JPEG, DICOM and other files types) Export images to CD/DVD with DICOM viewer (PDI) Print – Windows paper printer or DICOM film printer DICOM Store to other PACS Reporting Tools Simple Note Tools Diagnostic Reporting Tool - Requires Microsoft Office Distributed Workflow Maximum of seven concurrent users (including the server) Maximum of 19 authorized client connections Image compression for remote client connections DICOM Connectivity Tools DICOM Store, DICOM Print, DICOM Modality Worklist (SCU), DICOM Query / Retrieve (SCU & SCP) HL7 Connectivity Tools HL7 message reception for automatic patient registration Features and specifications are subject to change. KONICA MINOLTA’S COMMITMENT TO CUSTOMER SATISFACTION At Konica Minolta, your complete satisfaction is our number one goal. From pre-installation through the lifetime of your in- vestment, our professional staff, along with Konica Minolta’s trained and certified resellers, provides the technical expertise you need. Whether it be our 24/7 telephone support, our remote access service, or our Field Service Support Team, your needs are always covered. With the honor of being the number one rated CR vendor in the industry five years in a row comes great responsibility. You can rest assured that your Konica Minolta equipment will meet or exceed your highest expectations for many years to come. ImagePilot Client Minimum Requirements Minimum Specifcations for ImagePilot Client PCs: Computer - Pentium IV 2.66Hz, 2GB RAM, 160GB, CD/DVD RW. Display - Minimum resolution of 1280x1024. OS - Windows XP PRO SP2 or SP3, Vista, Windows 7 Professional (32- bit only for all operating systems). Note - Increased PC specifcations may be recommended when other software applications are also in use on the same PC. Antivirus software is recommended but should be set in accordance to Konica Minolta’s Antivirus Policy Installation Guidelines for optimum performance. 11999 Vet_ImagePilot_Bro.qx:Layout 1 2/9/11 1:04 PM Page 1

The Original All-in-One Veterinary Digital Radiography ... · The Original All-in-One Veterinary Digital Radiography Solution KONICA MINOLTA MEDICAL IMAGING USA, INC. 411 NEWARK POMPTON

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The Original All-in-One Veterinary Digital Radiography ... · The Original All-in-One Veterinary Digital Radiography Solution KONICA MINOLTA MEDICAL IMAGING USA, INC. 411 NEWARK POMPTON

The Original All-in-One VeterinaryDigital Radiography Solution

KONICA MINOLTA MEDICAL IMAGING USA, INC.411 NEWARK POMPTON TURNPIKEWAYNE, NJ 07470TEL: (973) 633-1500 FAX: (973) 633-0562WEBSITE: medical.konicaminolta.us

©2011 Konica Minolta KMMI-IP_Vet/11

ImagePilot Features and Specifications*

Hardware Components (specifications vary with each ImagePilot model)Imaging Station (specification ranges)Platform Desktop or TowerDrive Capacity 250GB (single drive) to 2TB RAID 5 (3x1TB)RAM 2GB to 4GBDisplay 19” to 24”. Available in resolutions up to 3MPCD/DVD Read/Write capability

REGIUS 110 Series CR ReaderThroughput (14x17) 40 cassettes per hour (REGIUS 110S)

60 cassettes per hour (REGIUS 110)76 cassettes per hour upgrade (REGIUS 110)

Grayscale 12 bitOuter dimensions W29.1” x D14.4” x H29.4”Weight 220 lbs

Backup or Extended Storage NAS 2TB RAID 5, 4TB RAID 5 DVD Back-up tool Manual or scheduled back-up to DVD

Software Features (features vary with each model)

Patient Registration Manual data entry or through work-list provider (DICOM or HL7)

Image Acquisition REGIUS 110 or 110S CR ReaderImport Images from CD/DVD, USB or folder – DICOM, PDF or JPEGAcquires images from other DICOM modalities

Basic Viewing Tools Window / Level, Viewing Size, Invert, Magnifier, Rotate/Flip

Standard Annotation Tools Line, Arrow, Free Form, Rectangle, Polygon, Ellipse, Closed Free FormFree Text and Preset Markers

Standard Measurement Tools Distance, Angle, Cardio Index, Cobb Angle, Pelvis Analysis, Rectangular Area, Elliptical Area, Polygonal Area, Rectangular CT

Image Output Export images to media (JPEG, DICOM and other files types)Export images to CD/DVD with DICOM viewer (PDI)Print – Windows paper printer or DICOM film printerDICOM Store to other PACS

Reporting Tools Simple Note ToolsDiagnostic Reporting Tool - Requires Microsoft Office

Distributed Workflow Maximum of seven concurrent users (including the server)Maximum of 19 authorized client connectionsImage compression for remote client connections

DICOM Connectivity Tools DICOM Store, DICOM Print, DICOM Modality Worklist (SCU), DICOM Query / Retrieve (SCU & SCP)

HL7 Connectivity Tools HL7 message reception for automatic patient registration

Features and specifications are subject to change.

KONICA MINOLTA’S COMMITMENT TO CUSTOMER SATISFACTION

At Konica Minolta, your complete satisfaction is our number one goal. From pre-installation through the lifetime of your in-vestment, our professional staff, along with Konica Minolta’s trained and certified resellers, provides the technical expertise you need. Whether it be our 24/7 telephone support, our remote access service, or our Field Service Support Team,your needs are always covered.

With the honor of being the number one rated CR vendor in the industry five years in a row comes great responsibility. You canrest assured that your Konica Minolta equipment will meet or exceed your highest expectations for many years to come.

ImagePilot ClientMinimum Requirements

Minimum Specifications for ImagePilot Client PCs:Computer - Pentium IV 2.66Hz, 2GB RAM, 160GB, CD/DVD RW.

Display - Minimum resolution of 1280x1024.

OS - Windows XP PRO SP2 or SP3,Vista, Windows 7 Professional (32-bit only for all operating systems).

Note - Increased PC specificationsmay be recommended when othersoftware applications are also in useon the same PC. Antivirus softwareis recommended but should be setin accordance to Konica Minolta’s Antivirus Policy InstallationGuidelines for optimum performance.

11999 Vet_ImagePilot_Bro.qx:Layout 1 2/9/11 1:04 PM Page 1

Page 2: The Original All-in-One Veterinary Digital Radiography ... · The Original All-in-One Veterinary Digital Radiography Solution KONICA MINOLTA MEDICAL IMAGING USA, INC. 411 NEWARK POMPTON

Signal Value

Capture images from CR, ultrasound, digital dental, andother modalities. Import images from a patient’sCD/DVD. Output patient images to CD/DVD (withDICOM viewer). Print images and reports. Send imagesto another PACS (i.e. to hospital or teleradiologist).

Register patients at reception. Perform exams in x-rayroom. Diagnose in your private office. Review imageswith patients in exam rooms. Maximum of 19 clientstations with a maximum of seven concurrent userstotal (including the server).

Nothing Makes Your Transition To Digital Easier

Simple... Yet AdvancedVersatility And Expandability To Meet Your Needs Now And In The Future

AutoPilot Image Processing optimizes image quality by analyzingthe actual captured image and applying the best image process-ing parameters. AutoPilot can also compensate for technique errors and off-centered positioning. Result: Consistent diagnosticquality images with every exposure. Retakes are virtually eliminated.

ImagePilot exemplifies the true meaning of an integrated digital radiography system. It combinespatient registration, CR acquisition, distributed workflow, image review, and long-term storage inone easy to use and maintain system. These advanced features meet private practice workflowneeds and eliminate the need for a separate PACS.

Referral and exam reports can be created using predefined or customized templates. Requires Microsoft Word 2003 or higher.

Patient images can be written to CD or DVD in PDIformat (includes a DICOM viewer). Excellent format foruse by other hospitals, by referring physicians, or bythe patient.

Register Patient Perform Exam Review Images

AutoPilot Image Processing

Consistent Image Quality

Versatile Input and Output

All-in-One Design

No need to specify species or exam type. Simply take the exposure and review the image.

Simplified Image Acquisition

Distributed Workflow

Review images from outside the office. Retrieve a patient’s images from another office or hospital. Shareimages with referring physicians. Additional software licenses and VPN connectivity may be required.

Efficiently exchange patient information between your office systems – no re-typing means error-free.DICOM and HL7 standards for maximum compatibility.

Veterinary EMR

Imaging

Demographics

OfficeNetwork

gnigamI

s

korNetwicefOfOff

ccsiichhipphaaprgommoeem

DDe

Advanced ConnectivityVeterinary Practice

Management Interoperability

CD/DVD Output Reporting

1 2 3

As Easy As1-2-3!