fisioline
fisioline
The new multi-wavelength
diode laser for epilation
Lumix® Epil Med Dual version is an innovative laser
technology at double wavelength of 808-1064nm for progressive
and permanent epilation.
Lumix® Epil Med Dual version generates a laser
beam with the combined action of two synergic wavelengths:
808nm and 1064nm. The laser light penetrates the skin and it
is absorbed by hair pigments inside the piliferous bulbs, with a
subsequent rise in temperature and permanent destruction of
hair follicle germ cells.
The result is progressive and permanent depilation through the
principle of selective photothermolysis.
Lumix® Epil Med Dual version adopts the Dual Wave System: the perfect combination of power (808nm)
and efficiency (1064nm).
The perfect mixing of the two wavelengths 808 and 1064nm
simultaneously emitted, allows a wider field of action,
guaranteeing a safer and even more effective epilation.
Lumix® Epil Med Dual version offers extensive
versatility and ease of use.
Hypodermis
Epidermis
Dermis
Skin Cooling System up to -10°C
Chiller Cooling System
2 independent water cooling
systemsLumix® Epil Med Dual version features a double and integrated cooling system: the Skin Cooling system, through Peltier
cells, guaranteeing greater client safety and comfort during treatment, and Chiller Cooling system, featuring chillers for laser
source temperature control.
Thanks to the innovative system, the subject‘s skin is double cooled: both before and after the spot.
Cooling ensures a great client comfort during Lumix® Epil Med Dual version treatment: the area
becomes desensitized before emission and the skin is refreshed after the spot, while guaranteeing maximum
freedom of movement for the operator.
The entirely automatic Chiller Cooling system maintains a constant cooling system liquid temperature,
thus preventing the device and laser source from over-heating. This system enables prolonged device
use; the operator can complete treatments over extensive parts of the body, with guaranteed source
duration.
SKIN COOLING UP TO -10°C
MAXIMUM COMFORT FOR THE TREATED SUBJECT
TREATMENTS ON EXTENSIVE PARTS OF THE BODY
Lumix® Epil Med Dual version enables the selection of a range of emission types
Single Pulse is the single step emission method, perfect for small zones and maximum
precision treatments.
Single Pulse
Modulated PulseModulated Pulse is a dynamic, rapid-action emission method. Thanks to the width
of the spot area equal to 3.0 cm2 and the modulation of pulses, treatment times
are halved, larger body areas can be treated in extremely short periods of time, while
guaranteeing homogeneous and uniform treatment on all body parts. This modality is
particularly effective for thin hair.
operatingmethods
PEAK POWER: 1700W
FOCUS ON THIN HAIR
808-1064nm: FOR ALL HAIR TYPES AND PHOTOTYPES
The Lumix® Epil Med Dual version device features a an intuitive use colour Touch Screen user interface.
The Wizard, a veritable digital guide to laser technology use, enables the operator to select, change and keep all
operation functions and working parameters under control at all times.
Lumix® Epil Med Dual version enables the operator to use both preset woman/man treatment protocols with
intuitive and easy to understand parameters.
Wizard and treatment protocols
Wizard and protocols
L E G S
5
5 20
745
Wizard and protocols
Lumix® Epil Med Dual version: handpiece
with 1700W power with Dual Wave System.
Handpiece Dual
R&D Fisioline® Study, Design and Laser TechnologyState-of-the-art Laser Technologies for over 30 years.
The laser device is equipped with an ergonomic handpiece, specifically designed by Fisioline® and which ensures highly
effective and fast treatment.
The Lumix® Epil Med Dual version handpiece has a spot area of 3.0 cm2 and it is separable from the device.
It ensures simple management and optimal maintenance.
It is a highly manageable applicator, compact and small in size.
The handpiece holder rod, an integral part of equipment, ensures that operators do not become tired during application.
handpiece Dualfor even faster treatments
M A D E I N I T A L YFisioline® srlBorgata Molino, 29 • 12060 VERDUNO (CN) • ITALY Tel.: +39.0172.470432-0172.470433 • Fax.:+39.0172.470891http://www.fisioline.com • e-mail:[email protected]
fisioline
fisioline
Ed. 0
9/20
19
Technical Specifications and Standards
Technical features and sizes of the devices described herein may be subject to change, based on technological evolution and constant improvements to production.
TECHNICAL SPECIFICATIONS
Technical classification electromedical device - Class I type B
Commercial classification laser device for epilation
Laser Source Class 4
Wavelengts 808-1064nm
High efficiency emission controlled fluence over 100 Joules
Closed deionised water cooling systemActive Chiller Cooling System: cooling with chiller; Active Skin Cooling System: cooling with semiconductor (Peltier)
Sapphire cooling -10/+5 °C on contact
Maximum irradiated area ~3cm2
Maximum power per impulse 1700W
Operating Procedures Single Pulse (5ms)Modulated Pulse (frequency up to 20 Hz)
Impulse Counter
Viewing work parameters colour Touch Screen display 5.7” resolution 640x480 pixels
Temperature sensor constant visualisation on display
Preset programs large database of treatment protocols
Phototype selection from phototype 1 to phototype 6
Safety pedal
Emergency stop button
Interlock connection
Power supply voltage 230Vac
Line frequency 50Hz
Absorbed power 1200VA
Weight 45Kg
Size 320x430x980mm
ACCESSORIES SUPPLIED
N° 1 Handpiece with high power laser source 1700 Watt
N° 1 Handpiece holder rod
N° 1 Mains network power cable
N° 1 Safety pedal
N° 2 Laser protection goggles
REFERENCE STANDARDS
EN 60601-1 (IEC 60601-1)
EN 60601-2-22 (IEC 60601-2-22)
EN 60825-1 (IEC 60825-1)
EN 60601-1-2 (IEC 60601-1-2)
EN 60601-1-6 (IEC 60601-1-6)
mark: the device complies with provisions contained in Directive 93/42/EEC, modified by the Directive 2007/47/EC.