Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
│8862 & 8863│
The New Gold Standard inNeurosurgical Ultrasound
Premium performance neuroimaging
Exceptionally intuitive system
Unmatched transducer function and design
Convenient, sterile needle guides
World’s smallest high-resolution
burr hole transducer
High-resolution craniotomy
transducer
BG
0480-B
01/2
011
Premium performance neuroimaging
• Superior, detailed images for precise neurostructural imaging.
• Clear, sharp images of brain and spinal cord.
• Real-time image guidance.
Exceptionally intuitive system
• Clinically intuitive – start quickly.
• Easy-to-use – finish fast.
• “Instant on” system start-up with the BK Power Pack.
Unmatched transducer function and design
• Extremely comfortable – like a natural extension of your hand.
• Press-and-scan transducer button for one-hand system control.
• Direct contact for sharper images without sterile covers.
Convenient, sterile needle guides
• Easy to use, the needle guide1 just snaps on and off.
• One patient one guide, sterile and ready-to-use.
• Easily detachable, needle and shunt stay in place.
Compatible with Brainlab Cranial navigation application with external ultrasound integration hardware and software.
Real Clinical Impact with High-Resolution Neuroimaging
Headquarters: Europe and Rest of World BK Medical Mileparken 34 ● DK-2730 Herlev Denmark Tel: +45 4452 8100 ● Fax: +45 4452 8199 www.bkmed.com
A wholly owned subsidiary of Analogic Corporation
Headquarters: USA B-K Medical Systems, Inc. 8 Centennial Drive ● Peabody, MA 01960 Tel: +1 800 876-7226 / +1 978 326-1300 Fax: +1 978 326-1399 www.bkmed.com
Specifications
Frequency range
5-12 MHz
Focal range
3-60 mm
Frame rate
>150
Scanning modes
B, M, Doppler, BCFM,
Tissue Harmonic Imaging
Contact surface (acoustic)
Transverse: 23 x 5.5 mm
Sagittal: 65 x 5.5 mm
Contact surface (overall)
Transverse: 127 mm2
Sagittal: 357 mm2
Image field (expanded)
180˚(transverse)
Weight (approx.)
Specifications Craniotomy transducer – 88622
Burr hole transducer – 88632
Frequency range
8862: 10-3.8 MHz
8863: 10-3.8 MHz
Focal range (typical)
8862: 5-68 mm
8863: 5-57 mm
Contact surface
8862: 29 x10 mm
8863: 10 x 8.6 mm
Sector angle
8862: 66º
8863: 46º
Disinfection
8862: Immersion,
STERRAD® 50, 100S, 200, NX,
100NX3
STERIS SYSTEM1®4
8863: Immersion,
STERRAD® 50, 100S, 200, NX,
100NX3
STERIS SYSTEM1®4
Weight (approx)
8862: 50 g
8863: 50 g
1Needle guides for future release. 2Market cleared by FDA only.
3Trademark Advanced Sterilization Products.4STERIS SYSTEM1® is not marked cleared in
the USA.