2
Model SMAN3 Digital Refrigerant Manifold and Vacuum Gauge Professional-grade instruments for HVAC/R field service Measure liquid line and suction line pressure and temperature. Measure vacuum in microns. Loud vacuum alarms. Easy field calibration for pressure AND temperature. Highly accurate 2 point field pressure calibration. Center button cycles temps. Calculate TARGET superheat, real-time ACTUAL superheat and actual subcooling automatically. Thermocouple storage posts and easy calibration pots. Magnetic hook storage. Drawstring pouch. Auto off. THE Digital Manifold for HVAC/R T1 T2 Atmospheric Pressure Superheat Subcooling T1 T2 Direct Saturation Target Superheat CAL CAL CAL CAL Test Pressure AUTO OFF Refrigerant ON/OFF Enter Units Alarm Digital Manifold + Vacuum Gauge SMAN3 ODDB HH:MM:SS Psig Kpa inHg cmHg Psig Kpa inHg cmHg SHT1 VSAT APO Microns HiLo Set Stable Alarm IDWB Target SH R- °F°C SCT2 LSAT °F°C °F°C SMAN3-clamshell-v10.qxd 5/28/2010 2:22 PM Page 1

THE Model SMAN3the HVAC/R field service tech. Specifications Best Parameter Ranges Accuracy Resolution Pressure 0Psig to 200Psig ±1Psi 0.1 200Psig to 500Psig ±0.3%rdg + 1Psi 0.1

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: THE Model SMAN3the HVAC/R field service tech. Specifications Best Parameter Ranges Accuracy Resolution Pressure 0Psig to 200Psig ±1Psi 0.1 200Psig to 500Psig ±0.3%rdg + 1Psi 0.1

Model SMAN3Digital Refrigerant Manifold

and Vacuum Gauge

Professional-grade instruments for HVAC/R field service

Measure liquid line and suction linepressure and temperature.Measure vacuum in microns.Loud vacuum alarms.

Easy field calibration forpressure AND temperature.Highly accurate 2 pointfield pressure calibration.Center button cycles temps.

Calculate TARGET superheat, real-time ACTUAL superheat and actual subcooling automatically.Thermocouple storage postsand easy calibration pots.

Magnetic hook storage.Drawstring pouch.Auto off.

THE Digital

Manifold forHVAC/R

T1 T2

AtmosphericPressure

SuperheatSubcooling

T1 T2 Direct Saturation

Target Superheat

CAL CAL

CAL CAL

TestPressure

AUTOOFF

Refrigerant ON/OFF

Enter

UnitsAlarm

Digital Manifold + Vacuum Gauge

SMAN3

ODDBHH:MM:SS

PsigKpainHgcmHg

PsigKpainHgcmHg

SHT1VSAT

APOMicronsHiLo

SetStableAlarm

IDWB

Target SH

R-

°F°C SCT2LSAT

°F°C

°F°C

SMAN3-clamshell-v10.qxd 5/28/2010 2:22 PM Page 1

Page 2: THE Model SMAN3the HVAC/R field service tech. Specifications Best Parameter Ranges Accuracy Resolution Pressure 0Psig to 200Psig ±1Psi 0.1 200Psig to 500Psig ±0.3%rdg + 1Psi 0.1

Digital Manifold with Micron GaugeModel SMAN3Functions for the

HVAC/R TechnicianWe made the SMAN3 to make it easy for HVAC/R techs to quickly optimizethe performance of air conditioners and refrigerations systems. It measurespressures and temperatures. It measures wet bulb for TARGET superheatcalculations. It even measures vacuum in microns for proper system evacuations. It calculates TARGET superheat, ACTUAL superheat, and actual subcooling.

Temperature and pressure sensors are easily field calibratable. The BIGbacklit widescreen display is viewable from 20 ft and impact resistant. Thebattery lasts 135 hours and has an auto-off feature. It's surrounded in rubberand comes with a protective 'hood-style' pouch. In other words, it's made forthe HVAC/R field service tech.

SpecificationsBest

Parameter Ranges Accuracy ResolutionPressure 0Psig to 200Psig ±1Psi 0.1

200Psig to 500Psig ±0.3%rdg + 1Psi 0.1Vacuum 50 to 1000microns ±10% or ±10microns 1°F -76°~199.9°F ±1°F 0.1

200°~999.9°F ±2°FPorts 3 x standard 1/4” male flare fittingUnits Psi, kPa, inHg, cmHg, °F, °C, micronsPower 6 x AA, auto-power-off 30 minutes, can be disabledBattery Life 135 hours typical alkaline

Features

Versatile

Vacuum Gauge AlarmsPressureReal-time Superheat and Subcooling SimultaneouslyTarget Superheat

Direct T1 T2 TemperatureSaturation TemperatureTwo Point Pressure Field Calibration

Safe

Easy to use

Enough refrigerant tables (35+) to analyze the vast majority of systems installed around the world.Measures microns of mercury for pulling a vacuum.Use any K-type thermocouple with K-type mini plug.Ports are fully compatible with the premium hoses you already own. 800Psi max overload pressure.Quick calibration of thermocouples and pressure.Select refrigerant, hook it up, view real-time SH/SC.

8 872 641 00 242

Model: SMAN3

T1 T2

AtmosphericPressure

SuperheatSubcooling

T1 T2 Direct Saturation

Target Superheat

CAL CAL

CAL CAL

TestPressure

AUTOOFF

Refrigerant ON/OFF

Enter

UnitsAlarm

Digital Manifold + Vacuum Gauge

SMAN3

ODDBHH:MM:SS

PsigKpainHgcmHg

PsigKpainHgcmHg

SHT1VSAT

APOMicronsHiLo

SetStableAlarm

IDWB

Target SH

R-

°F°C SCT2LSAT

°F°C

°F°C

IncludedSMAN3, (2) ATC1 Pipe Clamp Thermocouples, ATWB1 Wet Bulb Thermocouple, ATA1 Thermocouple, Drawstring Pouch, Batteries, Operator’s Manual

© Fieldpiece Instruments, Inc 2010