27
The MIT HED Accelerator Facility for Diagnostic Development for OMEGA, Z and NIF APS DPP New Orleans, LA 26-31 October 2014 NIF & OMEGA WRFs

The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

The MIT HED Accelerator Facility for Diagnostic

Development for OMEGA, Z and NIF

APS DPP New Orleans, LA

26-31 October 2014

NIF & OMEGA WRFs

Page 2: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Collaborators

M. Gatu Johnson, E. Armstrong, D. Orozco, H. Rinderknecht,

J. Rojas-Herrera, M. Rosenberg, H. Sio, C. Waugh, A. Zylstra,

D.T. Casey*, M. Manuel**, J.A. Frenje, C.K. Li, F.H. Séguin,

N. Sinenian***, R.D. Petrasso

Plasma Science and Fusion Center, MIT

T.C. Sangster

Laboratory for Laser Energetics

C. L. Ruiz

Sandia National Laboratories

R. J. Leeper

Los Alamos National Laboratories

*Now at LLNL

**Now at University of Michigan

***Now at Exponent

Page 3: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

The MIT Accelerator Facility provides a versatile precision

platform for HED Diagnostic Development and student training

• A linear ion accelerator generates DD, D3He and DT fusion products relevant for developing and testing NIF and OMEGA nuclear diagnostics

• A new x-ray source will replace the existing one and enhance the capabilities for diagnostic development and CR-39 response testing

• A pulsed DT neutron source will be implemented in the next year

• An etch/scan lab allows for precision on-site CR-39 processing

• Work done at the facility includes: WRF and Indium calibration, pTOF and CR-39 testing, development of the MRS Coincidence Counting Technique

Summary

This highly accurate development platform allows for refined work which has resulted in many student papers based on lab data

Page 4: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Capabilities

Page 5: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

The 150-keV linear ion accelerator runs with D+ or 3He+ ion beams, generated with a new ion source

Beam currents around 10 A are routinely achieved

Ion source

Target chamber

Gas inlet

Page 6: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Beam ions strike ErD2 or ErT2 targets, provided by

Sandia

Target Camera

Target

Turbopump

Residual

Gas

Analyzer

Target Positioner

Beam

Dump

AccessPort

NECRFIon

Source

Focus

(Einzel Lens)

IonSource

Power Supplies

GasControl

System

ErD2 targets are frequently doped with 3He to allow for generation of D3He fusion products

Page 7: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

DD, D3He, DT and T3He fusion products are generated

when D+ or 3He+ ions strike the target

+

+ D D

+

+ +

OR

3He (0.8 MeV)

n (2.45 MeV)

T (1 MeV)

p (3 MeV)

ErD2 target

+ D

3He

+

+ p (14.7 MeV)

+

4He (3.6 MeV)

+ 3He-doped ErD2 target

+ D T

ErT2 target

n (14.0 MeV)

+

4He (3.5 MeV)

+

OR

4He (4.8 MeV)

p

+ 3He +

ErT2 target

+ n

+ 4He +

+ +

D (9.5 MeV) +

T

Page 8: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

SBDs and an MCA provide real-time monitoring of

fusion rates, and fusion product energies

226Ra alphas are used to calibrate the system to within ± 50 keV. Precise calibration is important for charged-particle diagnostics development

Aluminum WRF (for use on NIF)

SBD

preamp

SBD

Page 9: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

A new X-ray source will allow extended studies of

diagnostic x-ray response and sensitivity

• Peak energy: 225 keV • Max dose rate: > 12 Gy/min

• Peak energy: 35 keV • Max dose rate: 0.5 Gy/min

The new system provides > 10x larger and more uniform irradiation area

Page 10: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

A pulsed DT source generating 3108 neutron/s in

~5 s pulses is being added to the lab

Source will be used to:

Characterize CR-39 DT-

neutron background

Improve calibration of

recently developed neutron

Wedge-Range-Filter (nWRF)

spectrometers

Test components for the

MRS-t neutron spectrometer

Page 11: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

The CR-39 etch/scan lab has served as model for

similar facilities at OMEGA and NIF

Research specialist Ernie Doeg scanning WRF CR-39

Page 12: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Applications

Page 13: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

The foundation for many diagnostics at OMEGA

and NIF is laid at the MIT HED accelerator facility

Recent work includes:

• Calibration (and re-calibration) of WRF spectrometers

• Indium calibration (Sandia)

• Assembly and testing of pTOF CVD diamond detectors

• CR-39 response and sensitivity testing and development of new processing techniques

• Development of the Coincidence Counting Technique (CCT) used in MRS analysis

• Development of a Step-Range-Filter for DD proton spectrum measurements

• Development of a scattering pinhole for proton and alpha yield measurements in high-fluence applications

Ongoing/upcoming work includes:

• Calibration of the magnet for the planned MagPTOF detector

• Development of an orange spectrometer for low-yield, low-energy proton and alpha spectrum measurements

• MRS-t component testing

Page 14: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Polar

Equatorial

50 cm

WRF spectrometers

A. Zylstra et al., submitted to Phys. Rev. E and Phys. Plasmas (2014) F.H. Séguin et al., Rev. Sci Instrum 83, 10D908 (2012) P.B. Radha et al., Phys. Plasmas 18, 012705 (2011) H.F. Robey et al., Phys. Plasmas 17, 056313 (2010)

Downshift gives ρR

WRF spectrometers calibrated at MIT are used

at OMEGA and the NIF for diagnosing ρR

WRF calibration

Graduate project: Alex

Example: Diagnosing R asymmetries on NIF

N101218 D3He Proton Spectra

Page 15: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Sandia Indium activation diagnostics were

calibrated using the facility DD-neutron capability

Indium calibration

Accelerator before major 2011-2012 upgrade

Page 16: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Recent experiments address CR-39 sensitivity to

x-rays, important for NIF and Sandia applications

CR-39 testing

DD

D3He

Thick Thin

90° 84° 87° 93° 96°

6 um

23 um

40 um

55 um

70 um

694 um

958 um

1061 um

1111 um

1161 um

No x-rays

Each filter results in a different proton energy

Undergraduate project: Jimmy

No x-rays

X-ray exposure

J. Rojas Herrera, UP8.00120 (this session)

Page 17: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Scattering pinhole

Undergraduate project: David

D. Orozco, UP8.00121 (this session)

The Scattering Pinhole measures charged-particle

yield and energy in high-fluence conditions

Total counts yield Particle spread (FWHM) energy

Page 18: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Orange Spectrometer

Undergraduate project: Emily

E. Armstrong, UP8.00119 (this session)

The Mini Orange Spectrometer will measure

charged-particle spectra E<5 MeV at low yield

CR-39

Simulated distribution on CR-39:

Preliminary design: Efficiency 510-4

Resolution 400 keV

Page 19: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

N-type connector

CVD diamond 200 um thick 10 mm diam

Filter Cap

100 um Au filter

50 um Ta filter

pTOF Exploded View

pTOF

pTOF* CVD diamond detectors are tested on the

x-ray source before fielding at NIF or OMEGA

WRF

pTOF testing

*H.G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)

Graduate project: Hans

Page 20: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Accelerated particles

ErD Target

Fusion Products

Magnet

CR-39

~30cm

~50cm

(Not to scale)

The MagPTOF* magnet will be tested using D3He-p

on the accelerator with mocked-up NIF geometry

MagPTOF calibration

Graduate project: Hong

*H.G. Rinderknecht et al., Rev. Sci. Instrum. (2014)

Page 21: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

NIF Diagnostics Leader Dr. Joe Kilkenny visits MIT

The MIT HED Accelerator Facility is continuously

adapting to serve the needs of the ICF community

Page 22: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

…while simultaneously allowing students to get real

hands-on experience…

Former graduate students Mario Manuel (now at U of Michigan) and Daniel Casey (now at LLNL) working on the accelerator

Page 23: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

H. Sio et al., “A technique for extending by 103 the dynamic range of compact proton spectrometers for diagnosing ICF implosions on the National Ignition Facility and OMEGA” (RSI 2014) M. Rosenberg et al., “Empirical assessment of the detection efficiency of CR-39 at high proton fluence and a compact proton detector for high-fluence applications” (RSI 2014) A. Zylstra et al., “A new model to account for track overlap in CR-39 data” (Nucl. Instrum. Meth. A 2012) N. Sinenian et al., “Improvements to the MIT Linear Electrostatic Ion Accelerator for advanced diagnostics development for OMEGA, Z and the NIF” (RSI 2012) D.T. Casey et al., “The Coincidence Counting Technique for orders of magnitude background reduction in data obtained with the Magnetic Recoil Spectrometer at OMEGA and the NIF” (RSI 2011) N. Sinenian et al., “The response of CR-39 nuclear track detector to 1-10MeV protons” (RSI 2011) M. Manuel et al., “Observable change in proton response of CR-39 due to prolonged exposure to high vacuum environments” (RSI 2011) Zylstra et al., “Increasing the energy dynamic range of solid-state nuclear track detectors using multiple

surfaces” (RSI 2011) S. McDuffee et. al., “An accelerator based fusion-product source for development of inertial

confinement fusion nuclear diagnostics” (RSI 2008)

…and publishing critical instrumentation papers in

peer-reviewed journals

Page 24: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Appendix

Page 25: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

Source size and scattering of neutrons are important for neutron diagnostics development

A target viewing system and MCNP simulations are used to

characterize the neutron-fluence field in the target chamber

Page 26: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

5.E+00

5.E+01

5.E+02

5.E+03

5.E+04

3.5 5.5 7.5 9.5 11.5 13.5 15.5

Co

un

ts /

Me

V

Deuteron Energy [MeV]

Response Matrix FitdataDS-fuelTTPrimary

CR-39

Implosion CD-foil

3-18 MeV (d)

215 cm

10 cm

Front side

Back side

J.A. Frenje et al., Rev. Sci. Instrum. 72, 854 (2001) J.A. Frenje et al., Rev. Sci. Instrum. (2008)

The MRS’ on OMEGA and the NIF use

CR-39 for detecting recoil deuterons

Analysis techniques

For low-signal applications, special processing is required to enhance S/B

Page 27: The MIT HED Accelerator Facility for Diagnostic ... Page/Papers/GatuJo… · The foundation for many diagnostics at OMEGA and NIF is laid at the MIT HED accelerator facility Recent

CR39

1st etch - track etch

Incident Neutron

Incident proton / deuteron Rl

Intrinsic noise

Coincidence

3rd etch – track etch – signal is revealed again

By applying the CCT, S/B is enhanced orders of magnitude*

-40 -20 0 20 40

-40

-20

0

20

40

0

5

10

15

-40 -20 0 20 40

-40

-20

0

20

40

0

5

10

15Misaligned 200mAligned

Rc Rc

Co

un

ts / P

ixe

l

y [

m]

x = xfront - xback [m] x [m]x = x1 - x2 [m]

*D.T. Casey et al., Rev. Sci. Instrum. (2011)

2nd etch – bulk etch up - to 200m removed

The coincidence counting technique* (CCT) for the

MRS was developed and optimized on LEIA

Analysis techniques

Graduate project: Dan