Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
The Implementation of the NUD Process
How it is used to develop reliable products such as the Lennox S30 thermostat
26 March 2019 | Joe Powell
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
Agenda
02 NUDS and FMEA
Why and what is NUDS01
06 Questions
03 The NUDS Process
04 Lennox S30 and NUDs
05 Summary
2
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
Why
• Tool that is part of our DFR process.
• In use for over 10 years.
• Identify risks.
• Begin mitigation sooner, with higher confidence of product success.
• NUDS
3
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
What is NUDs
• New: an adjective referring to something recently made, discovered, or created.
• Unique: a state or condition wherein something is unlike anything else.
• Difficult: requiring much work or skill to do or make.
4
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
What is NUDs
• New: Just as it implies, anything that is new. − First time using a material, component or technology.
› Switch, motor or LCD display never used before.
› Plastic material change.
› Newly implemented process.
− First time use in the present design.
› Used in xyz product, now used in abc product but same use and environment profile.
5
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
What is NUDs
• Unique: − Different use of material or component, with different use or environmental profile.
› What was used as an evaporator motor in a furnace, now is used as condenser motor in an outdoor unit.
• Different ambient temperature, humidity, vibration, dust.
› Same refrigerant pressure switch used in walk-in coolers, now is used in commercial HVAC.
• Also different ambient temperature and humidity, as well as duty cycles and use profile.
6
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
What is NUDs
• Difficult: requiring much work or skill to do or make.
− Challenging agency or government regulation requirement.
› Fuel efficiency improvement 20% by 2020 for automobile.
› Phase out of ozone-depleting refrigerants.
7
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and FMEA
• Supportive and helpful for FMEA and design process, not a replacement.• Why do we need an alternative?
• FMEA NEVER GETS COMPLETED SOON ENOUGH!!!
Why not? − People are too busy. Schedule driven.
− FMEA is boring, design is more fun.
− Difficult to get all members to attend.
− Paperwork check box.
− Design engineer not skilled in preparing FMEA.
8
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and FMEA
• FMEA Output:− Systematic identification of potential failures modes, and cause mechanisms.
− Manage risks.
− Recommend alternative solutions.
• All important for identifying tests to insure that the product meets all targeted performance criteria, but especially reliability objectives.
• NUDs can provide the same and sooner.
9
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and FMEA
10
Concept DFMEA
PrototypeDesign VerifyPre-
productionProduction
Specification Design
Ideal development process with DFMEA
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
PrototypeDesign VerifyPre-
productionProduction
NUDs and FMEA
11
Concept DFMEASpecification Design
What really happens with design DFMEA
THIS DOES NOT WORK FOR RELIABILITY ENGINEERS
DFMEA
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and FMEA
12
Concept
PrototypeDesign Verify
ProductionPre-
Production
Specification
Ideal development process with DFMEA, PFMEA AND S&IFMEA
PFMEAS&IFMEA
DFMEA Design
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and FMEA
Concept
PrototypeDesign Verify
ProductionPre-
Production
Specification
What really happens with PFMEA and S&IFMEA
PFMEA and S&IFMEA
THIS DOES NOT WORK FOR ANYONE
DFMEA Design
13
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
HOW DOES NUDs IMPROVE THIS?
14
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and FMEA
15
Concept DFMEA
PrototypeDesign VerifyPre-
productionProduction
Specification Design
NUDs for design
NUDs
RELIABILITY ENGINEERS CAN BEGIN TEST PLAN ON
HIGH RISK, SPECIAL REQUIREMENT ELEMENTS
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and FMEA
16
Concept
PrototypeDesign Verify
ProductionPre-
Production
Specification
NUDs for Process and Service and Installation
PFMEAS&IFMEA
THIS WORKS FOR P AND S&I FMEAs
DFMEA DesignNUDs
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
Summary to this Point
• New concept, NUDs.− New
− Unique
− Difficult
• Gets to high risks issues of change quickly.
• Helps reliability engineer develop risks mitigation sooner.
• Not a FMEA replacement.
• Efficient utilization of resources.
17
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Process
18
Block Diagram
Failure Mode
Worksheet
Interface
MatrixDFMEA Form
P-Diagram
FMEA Diagram
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Process
• Utilizes a portion of DFMEA process.
Block Diagram: Describes system relationships.
P-Diagram: Describes external factors.
19
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Process
20
Block Diagram
Failure Mode
Worksheet
Interface
MatrixDFMEA Form
P-Diagram
NUDs
NUDs Diagram
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Development Example
21
XYZ
Control
HW
FW
Detect ckt 1
Detect ckt 3
Detect ckt 2
Pump Drive
Regulator Drive
3.3V regulator circuit
Output Drive 1
CPU function
GV Drive
Power Supply
Input Detection
Relay Driver
LED
K5
PCB
R49
R46
R44
C4
D12
D13
R48
Input 1 Input 2 Output 1
24V Rectifier/
Regulator circuit
Block Diagram Step
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Development Example
22
XYZ Control: Noise
Factors
System Factors New/Unique/Difficult
Input 1 Yes
Input 2 No
Output 1 No
User Factors New/Unique/Difficult
Voltage Surges No
Number of cycles Yes
Wiring Yes
Environmental Factors New/Unique/Difficult
Temperature No
Humidity No
Vibration No
XYZ ControlINPUTS
Signal Factors
Response/Ideal
Function
OUTPUTS
P-Diagram Step
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUD Electronic Example
23
• Cell Phone− Next years model, what has changed.
NUD RISK MITIGATION
Table with
Headers
Display/touchscreen
Different button supplier
and increased count of
presses.
Breaking of glass.
Scratch resistance.
Touch sensitivity.
Meet lifetime button
presses.
Perform standard drop test.
Perform standard scratch
test.
Perform touch sensitivity test.
Perform standard button press
life test with increased number of
cycles.
Identify and
Record NUDs
Identify and
Record Risk
List Mitigation
Method
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Development, NUD Worksheet Step
24
• Simple:
Pump efficiency > 20 % Fuel economy Redesign -valve size and
shape
Insufficient torque Improve pump flow
List the NUD
Identify the
associated
risk.
List the test,
analysis, method
you will use to
mitigate that risk.
NUD RISK MITIGATION
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Development
• Two reasons to develop NUD list:− Type 1: Existing product change, upgrade etc.
− Type 2: New product development.
25
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Development
26
What has
changed?
What is
different about
use?
Anything
different about
environment?
What worries
you?
New Parts?
ABC Control
KEEP ASKING QUESTIONS!! INTERACTIVE DIALOGUE
Type 1: Existing Product Change
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs Development
27
New
Processor?
Different p/s
design?
More cycles
over lifetime,
different relay?
What wakes
you up at night?
What have we
never done
before?
XYZ Control
KEEP ASKING QUESTIONS!! INTERACTIVE DIALOGUE
Type 2: New Product
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
Summary
• NUDs process is straight forward table.
• Uses block diagram and p-diagram of FMEA process to focus thinking.
• Interactive dialogue with designer is important.
28
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
How was NUDS used for S30 Testing
29
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and S30
30
What is S30
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and S30
31
Over 250 parts Over 135 parts
HD Display
Over 500 parts
Device DFMEA Lines No. of Man Hours
HD Display 290 110
Mag Mount 218 60
Smart Hub 274 73
Total 782 243
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and S30
32
NUD Risk Mitigation
Display Touchscreen
Breakage for use or droppingPackaging drop test
Drop test without packaging
Scratch resistance Test to be developed.
Capacitive TouchElectronic qualification test, touch
sensitivity test
Chemical SusceptibilityChemical exposure with environmental
stresses.
UV susceptibility UV testing
Backlight life Analytics for backlighting life.
Viewing angle, brightness and contrast Display testing
Battery
LifeCombination of analytics and testing
under adverse conditions.
Fire Fire test
ESD susceptibility of regulator failure allowing
battery to thermally runaway.Electronic qualification test
Electronics EMI and Environmental Electronic qualification test
Plastic Housing Environmental susceptibility UV testing, thermal shock,
Durability and mounting strength. FEA, Plastic
Microphone and speaker
Durability (household chemicals) Durability test to be developed
Loudness of speaker Test to be developed.
Sensitivity of microphone Test to be developed.
PC Board Thermal/mechanical stresses FEA, HALT, Thermal Shock.
New FirmwareUnintended operation or not meeting
specificationFirmware test
Temperature Sensor Location Poor temperature control Temperature test
Proximiity Detector False triggering Proximity test
9 NUDs
Display NUD list
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and S30
33
NUD Risk Mitigation
Magnetic support for display Loss of strength over time.Analytics. Test to be
developed.
Magcon ConnectorCorrosion, connection reliability Corrosion test
Maintain spring tension Test to be developed.
Communication Bus EMI Electronic qualification test
2 screw wall mount with sheetrock
anchors
Holding strength to wall versus removal
strength of display
Analytics. Testing to be
developed.
Humidity SensorEMI Electronic qualification test
Accuracy Humidity sensor test
Plastic HousingEnvironmental susceptibility UV testing, thermal shock,
Durability and mounting strength. FEA, Plastic
METZ Connector Corrosion, connection reliability Corrosion/connector test
Life Meet Lennox life requirements ALT
PC Board Thermal/mechanical stresses FEA, HALT, Thermal Shock.
Power supplyEMI
Electronic qualification testHandle range of input voltage
New processor EMI/Environmental/LifeElectronic qualification test and
ALT
Communication protocol to HD Display EMI/Environmental/Life Electronic qualification test
New firmwareUnintended operation or not meeting
specificationFirmware test
13 NUDs
Mag-Mount NUD list
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and S30
34
Smart-Hub NUD listNUD Risk Mitigation
Pushbutton Switch
Meet # of pushes Analytics, testing if necessary.
Meet push force Analytics, testing if necessary.
2 wifi antennaESD Electronic qualification test
Gimbal Testing to be developed.
Plastic HousingEnvironmental susceptibility UV testing, thermal shock,
Durability and mounting strength. FEA
Linux operating system Intended and reliable functionality Firmware Testing
METZ Connector Corrosion, connection reliability LR-805
Power Sequencer Failure to process correctly during EMI. Electronic qualification test
WIFI RadioEMI, environment Electronic qualification test
Meet distance requirements Testing to be developed.
LED Meet brightness requirements Half Life calculation
Clear Plastic Lens Clear becomes cloudy over time. UV testing, thermal shock,
SD Card Holder Application SD card becomes dislodged. Package testing, HALT
Life Meet Lennox life requirements ALT
PC Board Thermal/mechanical stresses FEA, HALT, Thermal Shock.
12 NUDs
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs and S30
35
Comparison
Device FMEA Lines (man
hrs)
NUDs (man hrs)
HD Display 290 (110) 9 (2.5)
Mag Mount 218 (60) 13 (1)
Smart Hub 274 (73) 12 (2)
Total 782 (243) 34 (5.5)
Quicker than FMEA, higher confidence of reliability, early.
• Brought to market 1 month earlier with higher confidence of reliability.
• Warranty rate is lower than predecessor.
• No warranty claims due to high risk items.
• Identified unique manufacturing issues, magnet orientation.
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
NUDs
36
Pros/Cons of NUDs Method
• Pros:− Quicker path to identifying critical issues/components.
− Efficient utilization of engineering and manufacturing resources.
− Fewer team members to reach critical point.
− Help guide engineering team to prioritize corrective actions.
− Helps focus and prioritize FMEA process.
− Actions underway on addressing high risk items at start of FMEA.
− Help to reduce the time of project life cycle.
− Identify risks at the beginning when costs of change are low.
− Scales to scope of the project.
• Cons:− Not 100% coverage as FMEA.
− Doesn’t necessarily include historical failure history data.
− There is a chance failure modes can be missed.
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
Summary
37
• NUDs: New, Unique, Difficult.
• Uses block diagram, p-diagram.
• Does not replace FMEA.
• Identifies high risk issues at beginning of project with mitigation.
• Efficient use of resources, (S30 3% of FMEA man hours).
• Use for DFMEA, PFMEA, S&IFMEA.
• Quicker to market, higher confidence of reliability.
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
Speaker Bio
Joe Powell, Reliability Engineer, Fellow
Lennox International
Joe has been with Lennox for 31 years in various positions of design and management of electronic
controls and has spent the last 10 years in electronic control reliability. Previous to Lennox he worked in
electronic design at Ranco Electronics, Luminator, Northern Telecom. Joe holds an Associate and Bachelors
degree in Electrical Engineering and holds 8 patents.
Contact
214-460-3966
38
9000 Virginia Manor Rd Ste 290, Beltsville MD 20705 | 301-474-0607 | www.dfrsolutions.com
Copyright of DfR Solutions 2019
Questions?
39