2
The HammerFiX Advantage... PEEK Material Non-resorbable polymer Radiolucent = visualization of fusion site Safe: Medical device for 20+ years Mimics cortical bone = less chance of phalanx breakthrough Ability to cut through the implant = easy removal Zeniva is a registered trademark of the companies that comprise the Solvay Group. Unique Monolithic Design Opposing helical thread pattern on screw and barbed sides = compression Barbed segment designed to deploy to natural position in proximal phalanx and grab inner cortex = balanced pull-out strength Screw Segment Barbed Segment Opposing Thread Pattern Natural Position Fully Cannulated Ability to temporarily pin the MPJ = complete correction With wire in place, pull-out strength is increased by 50% Pullout Force – Non threaded section (N) HammerFiX (wire) n=5 HammerFiX (no wire) n=5 Single Piece Stainless Device n=2 K-wire (.9mm) n=5 0 5 10 15 20 25 30 35 4.4 2.0 20.7 31.4 *Data on file at Extremity Medical

The HammerFiX Advantage - Extremity Medical...Screw Segment Barbed Segment Opposing Thread Pattern Natural Position Fully Cannulated • Ability to temporarily pin the MPJ = complete

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The HammerFiX Advantage - Extremity Medical...Screw Segment Barbed Segment Opposing Thread Pattern Natural Position Fully Cannulated • Ability to temporarily pin the MPJ = complete

The HammerFiX™ Advantage...

PEEK Material• Non-resorbable polymer

• Radiolucent = visualization of fusion site

• Safe: Medical device for 20+ years

• Mimics cortical bone = less chance of phalanx breakthrough

• Ability to cut through the implant = easy removal

Zeniva is a registered trademark of the companies that comprise the Solvay Group.

Unique Monolithic Design• Opposing helical thread pattern on

screw and barbed sides = compression• Barbed segment designed to deploy to

natural position in proximal phalanx and grab inner cortex = balanced pull-out strength

Screw Segment

Barbed Segment

Opposing Thread Pattern

Natural Position

Fully Cannulated• Ability to temporarily pin the MPJ =

complete correction

– With wire in place, pull-out strength is increased by 50%

Pullout Force – Non threaded section (N)

HammerFiX (wire) n=5

HammerFiX (no wire) n=5

Single Piece Stainless Device n=2

K-wire (.9mm) n=5

0 5 10 15 20 25 30 35

4.4

2.0

20.7

31.4

*Data on file at Extremity Medical

Page 2: The HammerFiX Advantage - Extremity Medical...Screw Segment Barbed Segment Opposing Thread Pattern Natural Position Fully Cannulated • Ability to temporarily pin the MPJ = complete

300 Interpace ParkwaySuite 410Parsippany, NJ 07054Phone: 973.588.8980Customer Service: 888.499.0079Fax: 888.499.0542www.extremitymedical.com

Size Small – 2.8 Medium – 3.4 Large – 4.0

Overall Length (mm) 13.5 15 15

Major Diameter Screw (mm) 2.8 3.4 4.0

Major Diameter Barb (mm) 4.0 4.5 5.5

Barb Length (mm) Proximal 5.5 6.8 6.8

Threaded Length (mm) Middle 6.5 7.0 7.0

Guidewire (mm) Compatibility 1.1 (.045in) 1.4 (.054in) 1.6 (.062in)

Driver

ForcepsModular Handle

Guidewires

Drill/Tap Combo

Three Implant Sizes• Sized for all lesser joints

• Designed for all bone qualities

Convenience• Sterile packed implants

and instruments

• Each implant specific instrument kit contains the following items:

Extremity Medical and HammerFix are trademarks of Extremity Medical, LLC.

©Extremity Medical, LLC. 2017. All rights reserved.LBL-132-99305-EN Rev A 2/2017

Indication For Use: The Extremity Medical Hammer toe device is indicated for the fixation of osteotomies and reconstruction of the lesser toes

following correction procedures for hammer toe, claw toe, and mallet toe. Before use, physicians should review all risk

information which can be found in the instructions for use.