Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Specifications – Intracorneal Rings
• Pre-programmedtrajectoriesforallringsegments• Fullflexibility:1or2individualtunnels,or
1complete360°tunnel• Tailoredprocedures:differentdimensionsand
depthsforeachtunnelpossible• Maximalresectiondepth:850µm
Specifications – Intrastromal Pockets
• Pre-programmedtrajectoriesformostinlays• Manualoptionforcustomizationofthetrajectory• Secondarytunneloption
FEMTO LDV Z6Theultimatefemto-technologyforthewholeanteriorsegment
Z‑LASIK and Z‑LASIK Z – total flexibility
Xy-planarmodeorthree-dimensionalmode–yourchoice.Trulycustomizableflabcreation.
Specifications – Z‑LASIK and Z‑LASIK Z
• Flapdiameter:from6.5to10.0mm(0.1mmsteps)• Flapthickness:90to180µm(1µmsteps)• Flapgeometry:roundandoval• Borderresection:in-planecircularrimcutor
verticalcutsbetween30°and150°
Corneal surgery
Presbyopia1-tailoredtreatment:
• SIM-LASIK™–all-in-onecombinedZ-LASIKpluspresbyopiacorrection
• Post-LASIKtreatments–highlyprecisepocketresectionbelowanexistingflap
• Tailoredpocketsoftwareforintrastromalinlays
Keratoconustreatmentwithyourfemtosecondlaser–beoneofthefirst:
• Tunnelresectionsforintracornealringsegments• Easyinsertionthankstocompleteresection
ZIemeR IS the Femto‑teChnoLogy ComPAny oF todAy, TOMORROw AND THE FUTURE
Specifications – Keratoplastic
• Penetrating Keratoplasty• Lamellar Keratoplasty:
(D)ALK preparationofpatientanddonorresectionDSAEK verythinlamellaspossible
• Flexiblegeometry:roundandovalresection• Customizableanglededge• Adjustablepulseenergypossible(depending
onresectiondepthandcorneaquality)• Maxresectiondepth:850µm
therapeutic procedures
TheoptionalKeratoplastymodulesenableadditionalsurgicalcapabilitiesontotheFEMTO LDV Z6andZ6 PowerPlusmodels.
By means of an Artificial Anterior Chamber designed specifi-cally for the FEMTO LDV systems, perfect donor buttons can be excised.
Femto LdV Z6 PowerPlus
Anevenmorepowerfullasersourceallowingforhigherandadjustablepulseenergy.
PowerPlusisarealbreak-throughinfemtosecondlasertechnology.Yourchoicefortherapeuticprocedures.Amust-havefortheadvancedcornealsurgeon.
designed for future applications
Thecornealapplicationsareconstantlybeingdevelopedaswecontinuetolearn–andyourZ6 Modelsarealreadydesignedfortheseapplications.
THE FUTURE IN YOUR HANDS
1Thecreationofacornealpocketispartofapresbyopiaintervention.Availabilityofrelatedcornealinlaysandimplantsaccordingtopolicyoftheindividualmanufacturersandregulatorystatusintheindividualcountries.CataractprocedureswiththeFEMTOLDVZ2,Z4andZ6modelsarenotclearedintheUnitedStatesandinallothercountries.Anupgradepossibilityforthesedevicesisplannedoncecataractoptionsareavailableandclearedbytheresponsibleregulatorybodies.
• Preparedforfuturecornealapplications• DesignedforOCT• Designedforcataract1
Unique femtosecond technology
• Lowestpulseenergy(nJrange)• Highestpulserepetitionrate(MHz)• Microscopelensqualityoptics
true mobility, true efficiency
• Designedtobemovedbetweendifferentsurgicalrooms/clinics
• Fitswitheveryexcimer• Noneedtomovethepatient
FEMTO LDV Z MODELSThepowerofone
Ziemer ophthalmic Systems Ag,aZiemerGroupCompany,Allmendstrasse11,CH-2562Port,Switzerlandwww.ziemergroup.comwww.femtoldv.com
REF510.931.008
modular platform solution
• Convenienton-siteupgrades• Tailoredapplicationpackages• Designedforfutureapplications
outstanding clinical results
• Excellentvision• Veryfastvisualrecovery• FullcapabilityforLASIK,corneal
surgeryandtherapeuticprocedures
Z2 model
Z-LASIK
Z-LASIKZ
IntracornealRings(ICR)
IntrastromalPocket(ISP)
LamellarKeratoplasty(LKP)
PenetratingKeratoplasty(PKP)
Z4 model Z6 model Z6 modelPowerPlus
• • • •
• • •
• •
• •
• Standard software package To be purchased separately
DesignedforOCTDesignedforcataract
modular architectureAdaptedtoyourindividualrequirements
Keepingoureyeonthefuture,developmentisongoingonarangeofapplications.Haveconfidencethatyourplatformisreadyfortomorrow’stechnologytoday.every model is designed for an on‑site upgrade to the next model – and beyond!