Tornado Spectral Systems555 Richmond St W., Suite 705, Toronto, ON M5V 3B1P: +1 416.361.3444 E: [email protected]
Tornado Spectral Systems2359 N. Triphammer Rd., Ithaca, New York 14850P: +1 607.379.6185 E: [email protected]
tornado-spectral.com
The first high-performance virtual slit spectrometer. For fast, high-resolution sample discrimination that outperforms the competition.
Key Features
• High-resolutionwhilemaintaininghighflux
• Easytointegrateintoexistingdesigns
• Nosignificantresonanceunder600Hz
• Nomovingpartsorelectronics
HyperFlux 750msSpectrometerA 750msSpectrometerB 3375ms
300600900120015001800
SNR
350
300
250
200
150
100
50
0
RamanShift(cm-1)
ComparisonofHyperFlux785withtwoconventionalOEMspectrometers,RamanspectrumofKerosene
The HyperFlux 532 & 785 series is a compact high-resolution, high-throughput spectrometer designed for ease of integration as a powerhouse OEM component. Its small, rugged design delivers high performance even in challenging and space-constrained applications.
Specifications
Spectroscopic Performance
Spectral Range 480-680 nm (4090 cm-1 from a532 nm laser)
730-1095 nm (3600 cm-1 from a785 nm laser)
Spectral Resolution R = 2500 (0.24 nm FWHM, 7 cm-1), dispersion = 0.07 nm/pix
R = 1400 (0.65 nm FWHM, 8 cm-1), dispersion = 0.25 nm/pix
Grating 1800 lines/mm volume phase holographic, peak efficiency 85%
1200 lines/mm volume phase holographic, peak efficiency 80%
Input Source SMA fiber optic cable, NA = 0.22, core diameter 200 μm
SMA fiber optic cable, NA = 0.22,core diameter 200 μm
Slit No slit No slit
Detector SpecificationsPeak SNR 300 550
Detector Toshiba TCD1304DG Hamamatsu S11510-1106 array
Pixel Size 8 μm x 200 μm 14 μm x 14 μm
Cooling None None
Detector Length 3648 pixels (29 mm) 2048 x 64 pixels (29 mm x 0.9 mm)
Wavelength Sensitivity 200 - 1100 nm 200 -1100 nm
A/D Resolution 16 bits 16 bits
Integration Time 100 μsec - 6.5 sec >10 ms
Readout Rate 138 Hz 103 Hz
Linearity <1% deviation from linear fit <1% deviation from linear fit
Computer RequirementsComputer Interface USB 2.0 USB 2.0
Operating System Windows 7, XP, Vista Windows 7, XP, Vista
Memory Required RAM > 64 MB, Hard disk space >10 MB RAM > 64 MB, Hard disk space >10 MB
External Trigger Yes No
Software Libraries DLL files and static library DLL files and static library
Power Supply USB, no external source required USB, no external source required
Physical DimensionsWidth 6.7” [17.1 cm] 6.7” [17.1 cm]
Height 2.4” [6.0 cm] 3.2” [8.1 cm]
Depth 10.1” [25.8 cm] 10.1” [25.8 cm]
Weight 5 lbs [2.3 kg] 5.5 lbs [2.5 kg]
HyperFlux 532 HyperFlux 785
Tornado Spectral Systems555 Richmond St W., Suite 705, Toronto, ON M5V 3B1P: +1 416.361.3444 E: [email protected]
Tornado Spectral Systems2359 N. Triphammer Rd., Ithaca, New York 14850P: +1 607.379.6185 E: [email protected]
tornado-spectral.com