35
THE FIRST CHURCH OF CHRIST, SCIENTIST EXTERIOR LIGHTING PROJECT BLC PRESENTATION September 25, 2018

THE FIRST CHURCH OF CHRIST, SCIENTIST EXTERIOR ......S18 LED LINEAR UPLIGHT CENTERED ON WINDOW WITH 1 "WAM2" 2 INCH ADJUSTABLE MOUNT PER FIXTURE FASTENED TO EXISTING STONE SILL WITH

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    BLC PRESENTATIONSeptember 25, 2018

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT CONCEPTUAL APPROACH

    Mother Church and MotherChurch Extension primarywall facing the "Great Room".

    GREAT

    ROOM

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT CONCEPTUAL APPROACH

    REFLEC

    TING P

    OOL

    • Color temperature of lighting unified for both buildings.• Careful attention to how light would reflect in reflecting pool.

    Soft washes on the exterior tohelp frame the internallyilluminated stained glassthroughout.

    Primarily illuminatedfrom the outside, no internal illumination.

    Key Design Aspects:

    TMCXTMCO

    Softer R

    eflections

    in the Po

    ol

    Dramatic

    Reflectio

    ns

    in the Po

    ol

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT VIEW PRIOR TO RENOVATION

    EXISTING• CURRENTLY THE MOTHER CHURCH IS IN SILHOUETTE TO THE EXTENSION

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    CONCEPTUAL PROPOSED VIEW

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    PROPOSED RENDERED VIEW 1

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    PROPOSED RENDERED VIEW 2

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    PROPOSED RENDERED VIEW 3

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT LIGHT FIXTURE LOCATION VIEW

    S8

    S9S10

    S11

    S12

    S13

    S13

    S14

    S15

    S7

    S16S16

    S20

    xi

    S23

    S23

    S22

    S22S23

    S24

    S24

    S17

    S17's mounted at baseof roof

    S25

    S25

    S25

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    S8

    S9S10

    S15 S7

    S13

    S14

    S11S16

    S16 S16

    S16S16

    S22

    xi

    S20

    S23

    S23S23

    S23

    S24

    S16S16S12

    S17

    S17's mounted at baseof roof

    LIGHT FIXTURE LOCATION VIEW

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    S8

    S9

    S15

    S7

    S14

    S11S16

    S22

    S10

    S16

    S6

    S19S19

    S12 S16

    S18

    Sim. onoppositefacade

    Sim. onoppositefacade

    S23S23

    S23

    S17

    S17's mounted at baseof roof

    S25

    LIGHT FIXTURE LOCATION VIEW

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT CONSTRUCTION PHASING APPROACH

    PHASE 2

    PHASE 3

    PHASE 4

    PHASE 5

    PHASE 6

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT LIGHT FIXTURE LAYOUT PLAN

    A

    B

    C

    D

    S8S8

    S8

    S8

    S8

    S8

    S8

    S8S8

    S8

    S8

    S8

    S8

    S8

    S8

    S8

    S9

    S9

    S9

    S9

    S9S9

    S9

    S9

    S9

    S9

    S9

    S9

    S9S9

    S9

    S9

    S10

    S10 S10

    S10

    S10

    S10

    S10

    S10

    S10

    S10S10

    S10

    S10

    S10

    S10

    S10

    S11

    S11

    S11

    S11 S11S11

    S11

    S11

    S11

    S11

    S11

    S11 S11

    S11

    S11

    S11

    S12 S12

    S12

    S12

    S22

    S22

    S22

    S22S22

    S22

    S22

    S22

    S22

    S22

    S22

    S22

    S22S22

    S22

    S22

    S22

    S22

    S7

    S7

    S15 S15 S15

    S15 S15 S15S15

    S15

    S15

    S15

    S15

    S15

    S16

    S16 S16

    S16

    S16

    S16

    S16 S16

    S6

    S6

    S19

    S19

    S18

    S18

    S18S18

    S18

    S18's inlowerwindows

    S18's inlowerwindows

    S18

    S18

    S18S18

    S18

    Lam Partners

    Facade Lighting Diagram -with Conceptual MountingDetails

    180238/14/2018

    Red fixtures are existing thatare to be replaced with newLED fixtures

    Blue fixtures are new locationswith new LED fixtures, that neednew power feeds and control

    S14S14S14

    S14

    S14S14

    S14

    S14

    S23

    S23

    S23

    S23 S23 S23

    S23

    S23

    S23

    S23

    S23

    S23

    S23S23S23S23 S23S23

    S23

    S23

    S23

    S23's mountedon sill, centeredon window, typ.

    S17

    S17

    S17

    S17

    New fixtures with customarchitectural enclosures ormounting

    S17's mounted at baseof roof witharchitectural shield

    S23 S23 S23

    S25

    S25

    S25

    S25

    S25 mounted ategress door

    S25's mounted ategress door

    S25 mounted ategress door

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT LIGHT FIXTURE LAYOUT SECTION

    S17S17

    S15

    Extension Plaza Level0' - 0"

    Extension AuditoriumLevel

    16' - 9"

    Extension Balcony Level 133' - 8"

    Extension Balcony Level 246' - 10 3/4"

    Extension Balcony Level 357' - 5"

    Extension Dome AtticLower Level

    67' - 11 1/4"

    Extension Dome AtticMiddle Level

    98' - 6 7/8"

    Extension Dome AtticUpper Level

    131' - 4 3/16"

    Extension Dome CupolaLevel

    177' - 8 11/16"

    Extension Dome CupolaApex

    218' - 0 11/16"

    Extension Basement Level-9' - 5"

    Original Crawlspace-13' - 5 1/4"

    Original Vestry Level-7' - 6 1/4"

    Original Lobby Level-0' - 9 1/4"

    Original Auditorium Level6' - 8 3/4"

    Original Balcony Level23' - 11 3/4"

    Original Main Attic Level39' - 2 3/4"

    Original Tower BelfryLevel

    60' - 3 3/4"

    Original Tower Attic Level84' - 9 1/4"

    Original Tower Apex117' - 4 3/4"

    1A301

    S12

    S14 S14

    S8

    S9

    S10

    S8

    S9

    S10

    S12

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    Extension Plaza Level0' - 0"

    Extension AuditoriumLevel

    16' - 9"

    Extension Balcony Level 133' - 8"

    Extension Balcony Level 246' - 10 3/4"

    Extension Balcony Level 357' - 5"

    Extension Dome AtticLower Level67' - 11 1/4"

    Extension Dome AtticMiddle Level

    98' - 6 7/8"

    Extension Dome AtticUpper Level

    131' - 4 3/16"

    Extension Dome CupolaLevel

    177' - 8 11/16"

    Extension Dome CupolaApex

    218' - 0 11/16"

    Extension Basement Level-9' - 5"

    1A300

    S11

    S14 S14

    S8

    S9

    S10

    S8

    S9

    S10

    S22 S11S22

    LIGHT FIXTURE LAYOUT SECTION

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    LIGHT FIXTURE BRACKET AND MOUNT. FOUR PER FACADE.

    SLATES CUT ON RADIUS AROUND LIGHT FIXTURE BRACKET

    LIGHT FIXTURE BRACKET PLATE

    2 3/8" SQ. GALVANIZED STEEL TUBE POST WITH 16'-0" HORIZONTAL TO MOUNT LIGHT FIXTURE AND ELECTRICAL. (3) VERTICAL POST ATTACHEMENTS TO ROOF PER FACADE.

    SELF-ADHERED MEMBRANE UNDERLAYMENT STRIP FLASHING

    12"

    S17 16'-0" LINEAR FIXTURE, COMPRISED OF (4) 4'-0" LINEARS WITH 2 ADJUSTABLE MOUNTS PER FIXTURE BOLTED TO GALVINZED FRAME.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST

    1 1/2" = 1'-0"2S17 - Exterior LED Light Fixture Mounting Detail

    MOUNTING DETAIL AT TOWER

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT MOUNTING DETAIL AT EGRESS

  • THANKYOU

  • EXTRA DETAILS

    THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

  • THE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    2"

    2" M

    IN.

    9"

    S14 LED LINEAR UPLIGHT CENTERED ON WINDOW WITH 1 "WAM2" 2 INCH ADJUSTABLE MOUNT PER FIXTURE FASTENED TO GALVANIZED POST.

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTEDTO EXISTING STRUCTURE WITH HILTI EXPANSION ANCHORS.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST.

    1 1/2" = 1'-0"4S14 - Exterior LED Light Fixture Mounting Detail

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    TBD

    S23 LED LINEAR UPLIGHT CENTERED ON WINDOW WITH 1 "WAM2" 2 INCH ADJUSTABLE MOUNT PER FIXTURE FASTENED TO EXISTING STONE SILL WITH 2-4 HILTI EXPANSION ANCHORS.

    CONDUIT AND "J" BOX TO BE EXPOSED AT BUILDING INTERIOR. DRILL HOLE IN EXISTING WINDOW FRAME TO ROUTE WIRING TO SURFACE MOUNTED FIXTURE. FILL WITH SEALANT.

    1 1/2" = 1'-0"4S23 - Exterior LED Lighting Fixture Mounting Detail

    TYPICAL FOR EACH CORNER TOWER

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    2' - 6"

    GALVANIZED STEEL ANGLE TO MOUNT TO ELECTRICAL TO POST

    THREADED ROD

    GALVANIZED STEEL TUBE POST TO MOUNT LIGHT FIXTURE AND ELECTRICAL

    NOTES:1. SUPPORT POST SHOWN SCHEMATICALLY; FIELD VERIFY POST SIZE AND COMPONENTS NESCESSARY TO MOUNT FIXTURE AS SHOWN. COORDINATE WITH FIXTURE TYPE. SUBMIT FINAL PROPOSED CONFIGURATION, INCLUDING ANCHORAGE TO EXISTING DECK.

    HILTI EXPANSION ANCHORS OR LAG BOLTS; DEPENDING ON SUBSTRATE.

    8" M

    IN.

    S16 LED SPOT LIGHT 24" FROM ADJACENT WALL.BOLTED TO GALVANIZED FRAME.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST.

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTEDTO EXISTING ROOF STRUCTURE.1'

    - 0"

    TBD

    3 4

    1 1/2" = 1'-0"1S16 - Exterior LED Light Fixture Mounting Detail

    TYPICAL FOR MIRRORED FACADE

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    1' - 0

    "

    TBD

    S11 LED SPOT LIGHT CENTERED ON DOME RIB BETWEEN WINDOWS, BOLTED TO GALVANIZED POST

    GALVANIZED STEEL ANGLE ELECTRICAL TO MOUNT TO ANGLE ON POST

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTED TO EXISTING ROOF WITH HILTI EXPANSION ANCHORS

    1 2 1 1/2" = 1'-0"3S11 - Exterior LED Light Fixture Mounting Detail

    TYPICAL FOR OTHER HALF DOME

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    1' - 0

    "

    TBD

    S22 LED SPOT LIGHT CENTERED ON WINDOW. BOLTED TO GALVANIZED POST.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST.

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTEDTO EXISTING ROOF STRUCTURE.

    1 2

    1 1/2" = 1'-0"3S22 - Exterior LED Lighting Fixture Mounting Detail

    TYPICAL FOR OTHER HALF DOME

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    1' - 6"

    1' - 0

    "

    S19 LED FLOOD LIGHT BOLTED TO GALVANIZED POST.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST.

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTED TO EXISTING ROOF STRUCTURE.

    3 4

    C

    D

    1 1/2" = 1'-0"2S19 - Exterior LED Lighting Fixture Mounting Detail

    TYPICAL FOR OTHER HALF DOME

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    TBD

    S18 LED LINEAR UPLIGHT CENTERED ON WINDOW WITH 1 "WAM2" 2 INCH ADJUSTABLE MOUNT PER FIXTURE FASTENED TO EXISTING STONE SILL WITH 2-4 HILTI EXPANSION ANCHORS.

    CONDUIT, "J" BOX AND DRIVER TO BE LOCATION IN CRAWL SPACE ADJACENT TO RADIATOR ENCLOSURE.CUT OUT PORTION OF EXISTING WINDOW FRAME AND DRILL HOLE IN THROUGH FRAME TO ROUTE WIRING TO SURFACE MOUNTED FIXTURE. FILL WITH SEALANT AT EXTERIOR. PROVIDE OIL-RUBBED BRONZE PLATE COVER TOP CONCEAL WIRING AT INTERIOR.

    A

    B

    1 1/2" = 1'-0"1S18 - Exterior LED Lighting Fixture Mounting Detail

    TYPICAL FOR OTHER HALF DOME

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    LIGHT FIXTURE BRACKET AND MOUNT. FOUR PER FACADE.

    SLATES CUT ON RADIUS AROUND LIGHT FIXTURE BRACKET

    LIGHT FIXTURE BRACKET PLATE

    2 3/8" SQ. GALVANIZED STEEL TUBE POST WITH 16'-0" HORIZONTAL TO MOUNT LIGHT FIXTURE AND ELECTRICAL. (3) VERTICAL POST ATTACHEMENTS TO ROOF PER FACADE.

    SELF-ADHERED MEMBRANE UNDERLAYMENT STRIP FLASHING

    12"

    S17 16'-0" LINEAR FIXTURE, COMPRISED OF (4) 4'-0" LINEARS WITH 2 ADJUSTABLE MOUNTS PER FIXTURE BOLTED TO GALVINZED FRAME.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST

    1 1/2" = 1'-0"2S17 - Exterior LED Light Fixture Mounting Detail

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    2"

    2" M

    IN.

    9"

    S16 LED SPOT LIGHT BOLTED TO GALVANIZED POST FRAME ON BACK OF EXISTING STONE BALUSTRADE.

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTED TO EXISTING STRUCTURE WITH HILTI EXPANSION ANCHORS.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST.

    1 1/2" = 1'-0"4S15 - Exterior LED Light Fixture Mounting Detail

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    2" MIN.

    1' - 6"

    1' - 8"S7 LED FLOOD LIGHT WITH TENON ADAPTER FASTENED TO GALVANIZED POST AT TOP OF TMCO CHIMNEY.

    GALVANIZED STEEL ANGLE.ELECTRICAL TO MOUNT TO ANGLE ON POST.

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTED TO EXISTING STONE WITH HILTI EXPANSION ANCHORS.

    6"

    1 1/2" = 1'-0"2S7 - Exterior LED Light Fixture Mounting Detail

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    2" MIN.

    10"

    8"S6 LED FLOOD LIGHT WITH TENON ADAPTER CENTERED ON "ROSE WINDOW", FASTENED TO GALVANIZED POST AT PARAPET.

    2 3/8" DIA. GALVANIZED STEEL POST AND PLATE BOLTED TO EXISTING STONE WITH HILTI EXPANSION ANCHORS.

    3 4 1 1/2" = 1'-0"1S6 - Exterior LED Light Fixture Mounting Detail

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    S11

    S11

    S22

    S22

    S16

    S16 S16

    S18

    S23

    S23 S23 S23

    S25

    at

    Remove existing fixtureand clean stone

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    S25

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    S23 S23

    S23

    S25

  • DETAILSTHE FIRST CHURCH OF CHRIST, SCIENTISTEXTERIOR LIGHTING PROJECT

    DETAILS

    11 S11S11

    S22S22

    S19

    S18S18

    S25

    S25 mounted ategress door

  • THANKYOU