98
The effects of retinal image motion on the limits of spatial vision by Kavitha Ratnam A dissertation submitted in partial satisfaction of the requirements for the degree of Doctor of Philosophy in Vision Science in the Graduate Division of the University of California, Berkeley Committee in charge: Prof. Austin Roorda, Chair Prof. Susana Chung Prof. Michael DeWeese Summer 2017

The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

The effects of retinal image motion on the limits of spatial vision

by

Kavitha Ratnam

A dissertation submitted in partial satisfaction of the

requirements for the degree of

Doctor of Philosophy

in

Vision Science

in the

Graduate Division

of the

University of California, Berkeley

Committee in charge:

Prof. Austin Roorda, Chair

Prof. Susana Chung

Prof. Michael DeWeese

Summer 2017

Page 2: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

The effects of retinal image motion on the limits of spatial vision

© 2017

by Kavitha Ratnam

Page 3: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

1

Abstract

The effects of retinal image motion on the limits of spatial vision

by

Kavitha Ratnam

Doctor of Philosophy in Vision Science

University of California, Berkeley

Prof. Austin Roorda, Chair

Vision is not a static process. Our perception of the world is not merely a sequence of fixed snapshots but rather involves a dynamic process in which the visual input is synthesized over time to provide a more detailed and informative signal than would otherwise be possible using a fixed array of sensors. This dynamic signal is largely a result of fixational eye motion, or the constant ocular jitter that creates an ever-changing signal in each photoreceptor cell. It is not known how the visual system potentially exploits such transient signals to serve our finest spatial acuity, and how the relationship between visual acuity and the photoreceptor sampling limit can be muddled because of this fact. We used an adaptive optics scanning laser ophthalmoscope to precisely control the spatiotemporal input on a cellular scale in human observers to assess how acuity differed as a function of retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades, in relocating stimuli to a preferred region within the central foveal region. Combined, these results show the utility of fixational eye movements in high spatial vision.

Page 4: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

i

Table of Contents Table of Contents ..................................................................................................................................... i

List of Figures .......................................................................................................................................... iv

List of Tables ............................................................................................................................................. v

List of Abbreviations ............................................................................................................................. vi

Acknowledgements ............................................................................................................................ viii

Chapter 1 .................................................................................................................................................... 2

1.1 Introduction ................................................................................................................................ 2

1.1.1 Optical quality of the eye ................................................................................................ 2

1.1.2 Adaptive optics for retinal imaging ............................................................................ 2

1.1.3 Adaptive optics scanning laser ophthalmoscopy ................................................. 5

1.2 Methods ........................................................................................................................................ 6

1.2.1 Retinal imaging with AOSLO ........................................................................................ 6

1.2.2 Retinal eye tracking and stimulus delivery ............................................................ 7

1.2.3 Eye motion analysis......................................................................................................... 8

1.3 Summary ...................................................................................................................................... 9

Chapter 2 ................................................................................................................................................. 11

2.1 Abstract ...................................................................................................................................... 11

2.2 Introduction ............................................................................................................................. 11

2.3 Methods ..................................................................................................................................... 13

2.3.1 Study design .................................................................................................................... 13

2.3.2 Subjects ............................................................................................................................. 13

2.3.3 Clinical examination ..................................................................................................... 14

2.3.4 AOSLO image acquisition and cone structure analysis .................................. 15

2.3.5 Statistical analysis ......................................................................................................... 16

2.4 Results ........................................................................................................................................ 16

2.5 Discussion ................................................................................................................................. 22

2.5.1 Normal variability of human foveal cone density............................................. 22

2.5.2 Comparison of AOSLO normative cone measures with histologic data ... 22

2.5.3 Uncertainty of the relationship between PRL and the location of peak cone density….. ............................................................................................................................................ 23

Page 5: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

ii

2.5.4 AOSLO density measurements represent an upper bound of structural changes ………………………………………………………………………………………………………… 23

2.5.5 Longitudinal studies would facilitate accurate assessments of degeneration in individual subjects .......................................................................................................................... 24

2.5.6 Intrasubject variability of psychophysical measures ...................................... 24

2.5.7 Relationship between structural measures and VA ........................................ 25

2.5.8 Relationship between structural measures and foveal sensitivity ............ 25

2.5.9 AOSLO-based microperimetry for single-cell functional testing ................ 26

2.5.10 Structural measures may provide more reliable predictors of foveal degeneration than visual field .................................................................................................... 26

2.5.11 Less commonly used clinical measures of function may be more sensitive to structural changes than VA or sensitivity .............................................................................. 27

2.6 Summary ................................................................................................................................... 28

2.7 Longitudinal follow-up study and AOSLO-based acuity measures .................... 28

2.8 Acknowledgements ............................................................................................................... 29

Chapter 3 ................................................................................................................................................. 31

3.1 Abstract ...................................................................................................................................... 31

3.2 Introduction ............................................................................................................................. 31

3.2 Methods ..................................................................................................................................... 32

3.2.1 Subjects ............................................................................................................................. 32

3.2.2 AOSLO imaging and stimulation .............................................................................. 32

3.2.3 Eye movement analysis and trial rejection ......................................................... 33

3.2.4 Experiment 1: Natural versus manipulated retinal motion ......................... 33

3.2.5 Experiment 2: Contrast matching and discrimination performance ........ 34

3.2.6 Experiment 3: External computer-based simulation ...................................... 35

3.3 Results ........................................................................................................................................ 36

3.3.1 Nature of FEM during the acuity task and quality of stabilization ............ 36

3.3.2 Experiment 1: Discrimination benefits from FEM at the resolution limit ... ………………………………………………………………………………………………………… 38

3.3.3 Experiment 2: Contrast reduction during stabilization is not critical ...... 39

3.3.4 Experiment 3: Dynamic cone activation patterns suffice for discrimination benefit….. ............................................................................................................................................ 40

3.4 Discussion ................................................................................................................................. 41

3.6 Follow-up neural model of high-acuity vision in the presence of fixational eye movements ............................................................................................................................................. 43

Page 6: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

iii

3.7 Acknowledgements ............................................................................................................... 44

Chapter 4 ................................................................................................................................................. 46

4.1 Abstract ...................................................................................................................................... 46

4.2 Introduction ............................................................................................................................. 46

4.2 Methods ..................................................................................................................................... 48

4.2.1 Subjects ............................................................................................................................. 48

4.2.2 AOSLO imaging and stimulation .............................................................................. 48

4.2.3 Session 1: Mapping acuity within the central fovea ........................................ 49

4.2.4 Session 2: Stimulus refoveation within the central fovea ............................. 50

4.2.5 Measurement of location of peak cone density ................................................. 51

4.2.6 Eye movement analysis and trial rejection ......................................................... 51

4.3 Results ........................................................................................................................................ 51

4.3.1 Stability of PRL across sessions and distance from location of peak cone density ………………………………………………………………………………………………………… 51

4.3.2 Session 1 results: Acuity within the central fovea............................................ 53

4.3.3 Session 2 results: Fixational eye movements by initial stimulus location ... ……………………………………………………………………………………………………....... 53

4.4 Discussion ................................................................................................................................. 67

4.4.1 Fixation displacement across sessions and relationship to location of peak cone density……. ......................................................................................................................................... 67

4.4.2 Mapping acuity within the central fovea.............................................................. 67

4.4.3 Fixational eye movements by initial stimulus location .................................. 68

4.5 Acknowledgements ............................................................................................................... 71

4.6 Supplementary Figure ......................................................................................................... 72

Bibliography ........................................................................................................................................... 73

Page 7: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

iv

List of Figures

Chapter 1

Figure 1.1: Aberrations of the eye 4 Figure 1.2: Schematic of multi-wavelength AOSLO 6 Figure 1.3: Image-based eye motion trace 8 Chapter 2 Figure 2.1: AOSLO images of foveal cone mosaics 18 Figure 2.2: Visual acuity as a function of cone spacing 20 Figure 2.3: Foveal sensitivity as a function of cone spacing 21 Chapter 3 Figure 3.1: AOSLO micro-stimulation for projecting diffraction-limited stimuli… 36 Figure 3.2: Distribution of microsaccades over experimental trials 37 Figure 3.3: Retinal image motion due to FEM and motion manipulation 38 Figure 3.4: Stimulus motion improves acuity at the resolution limit 39 Figure 3.5: Contrast matching and discrimination at reduced contrast 40 Figure 3.6: Modelled dynamic cone activation produces a similar benefit to… 41 Chapter 4 Figure 4.1: Stimulus delivery locations during Sessions 1 and 2 50 Figure 4.2: PRL topography and location relative to peak cone density 52 Figure 4.3: Acuity measurements within central fovea 53 Figure 4.4: First microsaccade orientation and amplitude relative to stimulus… 55 Figure 4.5: Microsaccade frequency by initial stimulus location 57 Figure 4.6: Polar histograms of drift step orientation for Subjects S3 and S4 58 Figure 4.7: Drift step orientation relative to location of stimulus 60 Figure 4.8: Boxplots of horizontal microsaccade amplitude data 62 Figure 4.9: Visualization of results from Tukey-Kramer analysis 63 Supplementary Figure Figure S4.1: Initial microsaccade probability relative to stimulus onset 72

Page 8: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

v

List of Tables

Chapter 1

Chapter 2 Table 2.1: Summary of clinical and structural characteristics of patients studied 13 Table 2.2: Summary of statistical analyses: correlation between cone spacing… 17 Chapter 3 Chapter 4 Table 4.1: PRL characteristics across sessions 52 Table 4.2: First microsaccade orientation and amplitude relative to stimulus… 64 Table 4.3: Stimulus location relative to fixation center and location of peak cone… 65 Table 4.4: Tukey-Kramer analysis of microsaccade amplitudes (horizontal only) 66

Page 9: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

vi

List of Abbreviations

ADRP Autosomal-dominant retinitis pigmentosa

AOM Acousto-optic modulator

AOSLO Adaptive optics scanning laser ophthalmoscope

BCVA Best-corrected visual acuity

CCD Charge-coupled device

CD Cone density

CHM Choroideremia

CM Curved mirror

CNTF Ciliary neurotrophic factor

D Diopters

dB Decibels

DC Dichroic mirror

DM Deformable mirror

ETDRS Early Treatment of Diabetic Retinopathy Study

FEM Fixational eye movements

FM Flat mirror

FOC Fraction of cones

FS Fast scanner

LGN Lateral geniculate nucleus

MEMs Microelectromechanical systems

MS Microsaccade

NARP Neurogenic weakness, ataxia, retinitis pigmentosa

Nc Nyquist limit

OCT Optical coherence tomography

OD Right eye

OS Left eye

PMT Photomultiplier tube

PRL Preferred retinal locus of fixation

RGC Retinal ganglion cells

RP Retinitis pigmentosa

RP Retinitis pigmentosa

SD Standard deviation

SHWS Shack-Hartmann wavefront sensor

SLO Scanning laser ophthalmoscope

SS Slow scanner

USH Usher syndrome

VA Visual acuity

Page 10: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

vii

WFS Wavefront sensor

XL X-linked

Page 11: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

viii

Acknowledgements

First and foremost, I thank my advisor, Austin Roorda, for his support, advice, and

encouragement during my graduate years. The Roorda lab has been a wonderful

environment in which to pursue science, and I am grateful for the resources and unique

technology that have been available to me as a student in the lab. I have been fortunate to

have amazing colleagues from whom I have learned a great deal about psychophysics and

optics in the context of vision science. The support of fellow former and current students

William Tuten, Christy Sheehy, Ally Boehm, Katarina Foote, Sanam Mozaffari, Ethan

Bensinger, and Norick Bowers is much appreciated. I am especially thankful to Christy

Sheehy for being my cheerleader during the early years of graduate school and Ally Boehm

for supporting me through the latter. I would also like to thank Alex Anderson of the

Redwood Center for Theoretical Neuroscience for fostering a unique collaboration between

our research groups.

I express my heartfelt gratitude to Jacque Duncan, through whom I fortuitously stumbled

upon the fields of vision science and adaptive optics. My first exposure to clinical research

was in her lab, which motivated me to pursue a graduate career in vision science.

I thank my qualifying exam committee: Susana Chung, Dennis Levi, Tony Adams, and Laura

Waller for their time, advice and feedback. Their advice and knowledge were invaluable in

developing my thesis projects. I also thank my dissertation committee: Susana Chung and

Michael DeWeese for taking the time to read and give feedback on this dissertation.

I thank the many friends who have fostered my passions and contributed to the person I

am today. I appreciate their companionship and their efforts to make sure I maintained

work-life balance during my graduate years. Special thanks to Adeola Harewood and Kelly

Byrne for always lending a sympathetic ear and fostering baking as a (delicious) outlet for

creativity.

I am eternally grateful to Michael Oliver for his love and support in and out of graduate

school. Thank you for helping me maintain perspective and balance during graduate school

and for mentoring me in all things vision science-related.

And finally, I would like to thank my parents for their lifelong love and support. I am

grateful for the sacrifices they have made so that I could obtain an education and pursue

graduate school. None of this would have been possible without them.

Page 12: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

1

Chapter 1

Retinal imaging and stimulation with adaptive

optics scanning laser ophthalmoscopy

Page 13: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

2

Chapter 1

Retinal imaging and stimulation with adaptive optics scanning laser ophthalmoscopy

1.1 Introduction

1.1.1 Optical quality of the eye

For vision, the eye serves as the intermediary between the external world and our

perceptual experience. Photons from physical objects are transmitted through the eye onto

the retina; in spite of the perceived sharpness of our environment, this optical path is

fraught with aberrations that reduce the fidelity of the resulting retinal image. As

Helmholtz famously said, “Now, it is not too much to say that if an optician wanted to sell

me an instrument which had all these defects, I should think myself quite justified in

blaming his carelessness in the strongest terms, and giving him back his instrument”

(translated from Helmholtz, 1962). Much work has been done to understand the optics of

the eye, characterize their imperfections, and study their effects on visual perception

(Gerald Westheimer, 2006).

When a photon of light arrives at the eye, it must pass through the cornea, lens, and

vitreous before reaching the retina. Though imperfect, these transparent tissues form a

focused image at the retinal plane in an emmetropic eye. A non-accommodating eye has a

refractive power of about 60 diopters (D), which when focusing an image onto the retina,

corresponds to an ocular focal length of approximately 22 mm (Larsen, 1971). Deviations

from this axial length after eye growth result in hyperopia (undergrowth) or myopia

(overgrowth), the latter of which is predicted to afflict 50% of the global population by

2050 (Holden et al., 2016).

Ocular imperfections are typically categorized into low-order and high-order aberrations

(Figure 1.1). Low-order aberrations, defocus and astigmatism, are corrected with glasses or

contact lenses. Defocus results from a discrepancy between the eye’s focusing power and

axial length, while astigmatism is caused by radial asymmetries in the cornea and lens.

While low-order aberrations typically account for most of the eye’s imperfections, high-

order aberrations also contribute to noticeable retinal image blur (one such example being

the asymmetrical light scatter observed when viewing a street lamp at night).

1.1.2 Adaptive optics for retinal imaging

The low- and high-order components of ocular imperfections are oftentimes quantified as

Zernike polynomials, a set of orthogonal polynomials that constitute a wavefront function

for the eye (Born & Wolf, 1989). The ability to deconstruct and quantify these aberrations

was pertinent for the development of adaptive optics, a technique for wavefront

Page 14: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

3

measurement and correction that has its origins in astronomy. When collecting images of

celestial objects using ground-based telescopes, image quality is degraded due to the

Earth’s atmospheric turbulence (the same reason that stars appear to “twinkle” in the night

sky). In order to compensate for atmospheric turbulence, or ocular imperfections in the

case of ophthalmic imaging, one needs to measure a wavefront passing through an optical

system and compensate for the distortions thereafter. An early method for measuring the

image quality of a telescope was developed by Johannes Franz Hartmann, in which multiple

holes were created in an opaque mask covering a telescope’s aperture. The relative

alignment of images seen through the holes were an indication of the image quality of the

telescope (Hartmann, 1900). Later, Roland Shack and Ben Platt replaced the holes with an

array of lenslets with equivalent focal lengths; the local shape of a wavefront could then be

determined by the position of each lenslet’s focal spot on a photon sensor (Platt & Shack,

2001). For a flat wavefront, resulting from undistorted light coming from optical infinity,

the lenslet spots would form a grid-like lattice at the sensor; any deviations from a flat

wavefront would result in deviations in this pattern, with larger aberrations resulting in

larger deviations. This device, termed the Shack-Hartmann wavefront sensor (SHWS),

would prove to be instrumental in the development of adaptive optics for ophthalmic

imaging. Shack-Hartmann wavefront sensing for the eye was first implemented at the

University of Heidelberg to make fast, objective measurements of ocular aberrations

(Liang, Grimm, Goelz, & Bille, 1994). Later, at the University of Rochester, SHWS was used

to characterize wavefront properties in the normal human eye (Liang & Williams, 1997;

Porter, Guirao, Cox, & Williams, 2001).

Page 15: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

4

Figure 1.1 | Aberrations of the eye. The first 21 Zernike polynomials that constitute the expansion of a wavefront function for optical systems with a circular pupil, such as the eye. Each polynomial corresponds with a unique contributor to the wavefront: piston (Z0), tip/tilt (Z1), low order aberrations (Z2), and high order aberrations (Z3 onwards). Image from Wikipedia (licensed under Creative Commons License 3.0).

As previously mentioned, the low-order component of ocular aberrations can be corrected

using prescription lenses. High-order aberrations, however, are more complex in shape and

cannot easily be compensated for. A deformable mirror (DM), typically consisting of an

array of smaller mirrors on individual actuators, can take the complex shape necessary for

cancelling out errors in an incoming wavefront. Although DMs have been utilized for

closed-loop control in astronomy since the 1970’s (Hardy, Lefebvre, & Koliopoulos, 1977),

it was not until two decades later that closed-loop AO systems were developed for the eye

(Liang, Williams, & Miller, 1997).

Adaptive optics was initially integrated into flood-illuminated ophthalmoscopes, which

provided the first high-quality in vivo images of the cone photoreceptor mosaic (Liang,

Williams, & Miller, 1997). Correcting for aberrations over a larger, dilated pupil increased

the numerical aperture and hence angular resolution of the system, enabling

unprecedented visualization of the cone photoreceptor mosaic. Delivery of stimuli through

this system resulted in improvements in contrast sensitivity and visual acuity, suggesting

that the eye’s optical performance was improved with adaptive optics (Liang et al., 1997;

Roorda & Williams, 1999, 2002; Yoon & Williams, 2002).

Page 16: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

5

1.1.3 Adaptive optics scanning laser ophthalmoscopy

Although early adaptive optics ophthalmoscopes offered unprecedented in vivo images of

the cone photoreceptor mosaic, these systems were limited in temporal resolution by the

low capture rate of the charge-coupled devices (CCDs) available at the time. While early

flood-illuminated AO systems had frame rates capping at 10 Hz, more recent systems have

reached rates upwards of 100 Hz due to improvements in sensor semiconductor

technology (Bedggood & Metha, 2012; Rha et al., 2006). Although flood-based AO systems

have sufficient resolution for visualizing individual cones, the ability to track and stimulate

specific retinal regions is impaired by the inability to measure and compensate for ongoing

fixational eye movements. This limitation in the capabilities of flood-based system

motivated the integration of AO into the scanning laser ophthalmoscope (SLO).

The SLO was invented in the 1980’s and is similar to a scanning laser microscope in that an

image is collected pixel-by-pixel as the imaging beam moves across the tissue of interest.

The primary difference between modalities is that the eye, rather than a fabricated lens,

serves as the objective in an SLO (Webb, Hughes, & Delori, 1987). As a result, the presence

of ocular aberrations set an upper limit to the image quality achievable by such a system.

To mitigate this problem, Roorda and colleagues developed the first adaptive optics

scanning laser ophthalmoscope (AOSLO), improving lateral resolution from 5 to about 2.5

microns and axial resolution from 300 to better than 100 microns (Roorda et al., 2002).

The enhanced axial resolution afforded by AOSLO enabled true optical sectioning of the

retina’s vascular, photoreceptor and nerve fiber layers, improving in vivo characterization

of retinal structure.

Subsequent generations of the AOSLO have upgraded deformable mirrors (Zhang, Poonja,

& Roorda, 2006), multiple wavelengths for imaging and stimulation (Grieve, Tiruveedhula,

Zhang, & Roorda, 2006), and the ability to visualize parafoveal rods and foveal cones

(Dubra & Sulai, 2011; Merino, Duncan, Tiruveedhula, & Roorda, 2011). Most recently,

implementation of non-confocal split-detection techniques have significantly improved

visualization of retinal vasculature with the AOSLO (Sulai, Scoles, Harvey, & Dubra, 2014).

Since its creation, the AOSLO has been used extensively to characterize retinal

degenerations (Carroll, Kay, Scoles, Dubra, & Lombardo, 2013; Duncan et al., 2007; Roorda

& Duncan, 2015; Roorda, Zhang, & Duncan, 2007; Talcott et al., 2011), correlate visual

psychophysics with retinal structure (Harmening, Tuten, Roorda, & Sincich, 2014; Rossi &

Roorda, 2010; Rossi, Weiser, Tarrant, & Roorda, 2007; Sabesan, Hofer, & Roorda, 2015;

Tuten, Tiruveedhula, & Roorda, 2012), and to characterize chromatic aberrations across

the visual field (Winter et al., 2016).

Page 17: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

6

1.2 Methods

1.2.1 Retinal imaging with AOSLO

Figure 1.2 | Schematic of multi-wavelength AOSLO. Wavefront sensing is done with 940 nm light with 3 separate channels (543, 680, 840 nm) for imaging and stimulus delivery. CM, curved mirror; DC, dichroic mirror; DM, deformable mirror; FM, flat mirror; FS, fast scanner; PMT, photomultiplier tube; SS, slow scanner; WFS, wavefront sensor.

Figure 1.2 shows a schematic of a multi-wavelength AOSLO. The first experiment reported

in this document (see chapter 2) was conducted with the AOSLOIII system located at the

University of California, San Francisco. Subsequent experiments were respectively

implemented with the AOSLOII (chapter 3) and AOSLOIV (chapter 4), located at the

University of California, Berkeley.

The imaging source for the AOSLOII and AOSLOIII systems was 840 nm light from either a

superluminescent diode (Superlum, Cork, Ireland) or broadband supercontinuum light

source (SuperK Extreme, NKT Photonics A/S, Birkeød, Denmark); 680 nm light (source)

was used for experiments conducted with AOSLOIV. Images were obtained by moving the

imaging beam across the retina in raster pattern using resonant and galvanometric

scanner. For the experiments described in this document, scanning amplitudes ranged

from 0.9° (~260 µm) to 1.5° (~440 µm) of visual angle. Ocular monochromatic aberrations

were dynamically measured with a custom-built Shack-Hartmann wavefront sensor and

corrected with a deformable mirror (source) at a maximum rate of 24 Hz.

Page 18: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

7

A photomultiplier tube (PMT; Hamamatsu, Japan) detected and recorded the imaging light

intensity reflected from the eye; to block light scattered from other retinal layers from

entering the PMT, a confocal pinhole was placed conjugate to the focus location of the

ingoing beam. Each 512-by-512-pixel frame of an AOSLO video was created by assigning

pixel intensities based on the position of the scanning mirrors, with a maximum frame rate

of 30 Hz.

For the experiments reported in this document, stimuli for visual psychophysics were

embedded directly into the raster by selectively turning off the laser (Poonja, Patel, Henry,

& Roorda, 2005) at discrete points during the scan using an acousto-optic modulator (AOM;

Brimrose Corp, Baltimore, MD, USA). Since the stimulus was generated pixel-by-pixel in the

scanning raster, a given point in the retina was exposed to the stimulus for a short duration

of time; subjects perceived the stimulus as appearing continuous.

1.2.2 Retinal eye tracking and stimulus delivery

The eye is constantly in motion, even during fixation on a static object. These fixational eye

movements serve several purposes, including relocating objects of interest to the preferred

retinal locus of fixation (PRL) and preventing neural adaptation and image fading to an

unmoving object (for review see (Martinez-Conde, Macknik, & Hubel, 2004)). These eye

movements, which can move an image across several to several dozen photoreceptor cells,

impose difficulties when trying perform visual psychophysics at specific retinal locations.

Although the AOSLO video rate is 30 Hz, eye motion traces can be retrieved from AOSLO

images at temporal frequencies exceeding 1000 Hz. Since AOSLO images are collected via

raster scanning, eye movements occurring during the collection of a single frame induce

compression, shearing, translation, or expansion in the final image. The positional

differences between horizontal segments of an individual frame and reference image can

then be used to quantify eye motion at much higher frequencies than the video rate

(Stevenson & Roorda, 2005; Vogel, Arathorn, Roorda, & Parker, 2006). While this technique

was initially performed exclusively during offline analyses, hardware and algorithmic

improvements have made real-time eye motion tracking possible (Arathorn et al., 2007;

Yang, Arathorn, Tiruveedhula, Vogel, & Roorda, 2010).

The accuracy of real-time AOSLO eye tracking depends on numerous factors, including

image quality, field size, the amplitude of eye motion, small inaccuracies in predicting the

eye’s current location, and slight lags in preparing the AOM for stimulus delivery. In spite of

these factors, AOSLO stimulus delivery has been shown to be precise to within 0.15 arcmin

(Arathorn et al., 2007; Yang et al., 2010), less than half the diameter of a foveal cone. For

stimuli directly encoded into the imaging scanning raster, there is an unambiguous record

of stimulus retinal position during a given trial.

Page 19: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

8

1.2.3 Eye motion analysis

AOSLO eye tracking depends on co-registration of individual frames to a standard

reference retinal image. The reference image is assumed to be undistorted by eye

movements; since individual frames contain distortions, the reference frame is an averaged

composite of these frames, assuming net motion of the eye is zero over the course of the

video (Stevenson & Roorda, 2005). Reference frames are generated iteratively by first

creating an average image with good frames only. Additional frames without saccades are

then added to improve the reference image; this final image is then used to register

horizontal strips from each frame to the reference. If N horizontal strips are analyzed per

image and the video frame rate is 30 Hz, the final eye tracking frequency is N*30 Hz. For

the eye motion analyses cited in this document, each frame was divided into 28 strips,

resulting in a temporal resolution of 840 Hz (Figure 1.3).

Figure 1.3 | Image-based eye motion trace. Example 840 Hz eye movement trace derived using an image-based cross correlation algorithm (Stevenson and Roorda, 2005 & 2010). The blue and orange traces indicate horizontal and vertical eye movements respectively. The high frequency spikes, most noticeable in the vertical trace, result from artifacts in the original reference image and tracking errors with the top strip of each frame.

Registration of each strip to the reference frame is performed by computing a two-

dimensional cross correlation. To expedite this step, the search region within the reference

frame is constrained based on motion traces from an earlier, coarser correlation step. Sub-

pixel accuracy can be achieved by fitting a cubic spline function to the correlation peak in

the finer resolution step.

Page 20: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

9

If the reference frame has any distortions, such as those caused by torsion, the power

spectrum of the eye movement trace will show artifacts at 30 Hz and at every subsequent

harmonic. Additionally, large saccades may impair the cross-correlation analysis for two

reasons: (1) the image shear within a strip resulting from a high-velocity movement and

(2) minimal overlap between the retinal regions visible in the reference frame and the

given image. In spite of these limitations, the eye tracking algorithm is typically accurate to

< 1 arcmin and has been shown to outperform other conventional eye trackers (Stevenson

& Roorda, 2010).

1.3 Summary

Monochromatic ocular aberrations have imposed limitations on the resolution achievable

by conventional ophthalmoscopes. Within the past several decades, the development of

adaptive optics has made it possible to quantify and compensate for the light scatter caused

by these imperfections. The adaptive optics scanning laser ophthalmoscope offers

unprecedented visualization of cells within the living human eye, and the integration of

high-accuracy eye tracking and stimulus delivery make possible visual psychophysics at the

scale of individual cells. Chapter 2 will describe how the AOSLO has been applied to

correlate retinal structure with clinical measures of visual function. Chapters 3 and 4 will

describe our efforts to better study the effects of fixational eye movements on high spatial

resolution (Chapter 3), as well as the specific role of microsaccades during high-acuity

tasks (Chapter 4).

Page 21: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

10

Chapter 2

Relationship between foveal cone structure

and clinical measures of visual function

Page 22: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

11

Chapter 2

Relationship between cone structure and clinical measures of visual function

2.1 Abstract

The fovea is the retinal location with highest cone density and thus sharpest spatial

resolution, making it a crucial region to study when monitoring the progression of retinal

diseases. Due to difficulties in quantifying structural retinal changes, clinical measures of

function, namely visual acuity (VA), are used to indirectly monitor disease progression.

However, VA is known to be preserved until late stages of rod-cone degeneration due to

factors such as intrasubject variability and the inherent subjectivity of such techniques. As

such, efforts have been made to develop objective measures for quantifying foveal

degeneration, but these attempts have been limited due to the low optical quality of

conventional imaging systems. The integration of adaptive optics into the scanning laser

ophthalmoscope has made it possible to directly visualize the in vivo photoreceptor mosaic

and measure cone spacing and density in normal and diseased eyes. In the present cross-

sectional study, we compare AOSLO cone structural measures with clinical measures of VA

and foveal sensitivity in a cohort of patients with retinal degenerations. The results show

that VA and sensitivity are less sensitive indicators of the integrity of the cone mosaic than

direct, objective measures of cone structure. A recent longitudinal follow-up to the cross-

sectional study, outlined in section 2.7, shows that structural cone loss precedes acuity

changes over a period of 10 months to 5 years.

2.2 Introduction

The fovea, with its high cone density and sharp visual acuity, is the retinal location used for

most everyday tasks, such as reading and driving. Because of its importance in fine visual

resolution, foveal vision is commonly used to track the progression of retinal

degenerations. In the case of rod-cone degenerations, in which cone loss works its way

inward from the retinal periphery, the foveal function is preserved until late stages of

disease, making it imperative to monitor vision loss before it encroaches on central vision.

Since most imaging modalities have insufficient resolution to quantify structural changes in

the cone photoreceptor mosaic, clinical measures of function, such as visual acuity and

foveal sensitivity are used to monitor disease progression. However, patients with good

Snellen VA (20/30 or better) have shown significant foveal cone abnormalities measured

via contrast sensitivity (Akeo, Hilda, Saga, Inoue, & Oguchi, 2002; Lindberg, Fishman,

Anderson, & Vasquez, 1981; Wolkstein, Atkin, & Bodis-Wollner, 1980) and foveal

thresholds (Alexander, Hutman, & Fishman, 1986). The inherent subjectivity of

psychophysical techniques lead to increased intrasubject variability in VA (Arditi &

Cagenello, 1993; G A Fishman et al., 1994; Grover, Fishman, Gilbert, & Anderson, 1997;

Page 23: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

12

Vanden Bosch & Wall, 1997) and sensitivity (Kim, McAnany, Alexander, & Fishman, 2007;

Ross, Fishman, Gilbert, & Anderson, 1984; William Seiple, Clemens, Greenstein, Carr, &

Holopigian, 2004) measures, making it difficult to objectively quantify the extent of foveal

degeneration. Previous studies of inherited retinal degenerations have shown that

conventional functional measures have anywhere from 5-year to 15-year half-life times of

visual field loss (Berson, Sandberg, Rosner, Birch, & Hanson, 1985; Holopigian, Greenstein,

Seiple, & Carr, 1996; Iannaccone et al., 2004; Massof, Dagnelie, Benzschawel, Palmer, &

Finkelstein, 1990).

Due to the unreliability of clinical functional measures, objective measures of cone

structure may serve as more robust and sensitive indicators of foveal degeneration.

Previous studies have shown significant disparities between psychophysical and

anatomical data. Cone photopigment optical density reductions have been observed in

retinitis pigmentosa (RP) patients with normal acuity (Elsner, Burns, & Lobes, 1987;

Kilbride, Fishman, Fishman, & Hutman, 1986; van Meel & van Norren, 1983), and Geller

and Sieving reported that loss of 90% of foveal cones was necessary to significantly impair

grating acuity (Geller & Sieving, 1993). Alexander and colleagues concluded that increased

foveal cone spacing rather than reduced photopigment optical density was responsible for

lowered grating, Vernier, and letter acuities (Alexander, Derlacki, Fishman, & Szlyk, 1992).

A histologic study showed abnormal foveal cone spacing in an RP patient with normal

acuity (Flannery, Farber, Bird, & Bok, 1989).

Due to monochromatic ocular aberrations, structural assessment of the living retina has

been precluded by the low optical quality of conventional imaging systems. Within the past

few decades, the development of non-invasive, high-resolution techniques such as optical

coherence tomography and adaptive optics have revolutionized the field of clinical

ophthalmology. AO-based studies of retinal degeneration have shown significant

correlations between macular cone spacing and central visual function, but the unique

anatomy (Ahnelt, 1998) and small diameter of foveal cones made it difficult to assess cone

structure at the foveal center. Within the past few years, improvements in AOSLO optical

design (Dubra & Sulai, 2011) have made it possible visualize the foveal cone mosaic in

patients with retinal degeneration. Although there is a growing body of studies (Carroll et

al., 2012; Merino et al., 2011; Yoon et al., 2009) on foveal cone anatomy, comparisons

between foveal cone structure and clinical measures of function in a large cohort of

patients with retinal degeneration have yet to be done.

In the present study, we quantified foveal cone spacing and density in 26 patients with

retinal degeneration and compare these measures with best-corrected VA (BCVA) and

foveal sensitivity. Cone density values below normal were compared to visual function to

determine whether cone structure is a more sensitive indicator of disease severity.

Page 24: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

13

2.3 Methods

2.3.1 Study design

Research procedures followed the tenets of the Declaration of Helsinki, and informed

consent was obtained from all subjects. The study protocol was approved by the

institutional review board of the University of California, San Francisco; the University of

California, Berkeley; and the Medical College of Wisconsin.

2.3.2 Subjects

Twenty-six patients (18 female and 8 male) with inherited retinal degenerations were

characterized clinically (Table 2.1). Patients were excluded if they had other ocular or

systemic conditions that could affect VA, including amblyopia, cataract, and foveal edema.

Subj

Age/

sex

Eye Condition Visual acuity Humphrey 10-2 foveal sensitivity

PRL Foveal cone spacing % Cones below average

BCVA

ETDRS Logarithmic (dB); Linear (1/Lambert))

Location Fixational stability in arcmin

(SDx, SDy)

Z-score

Average eccentricity from PRL (arcmin [degrees])

1 17/M

OS CHM 20/25

80 34*; 2511.89* Fixation target

4.51, 3.86 2.07 1.62 [0.03] 38.02

2 38/F OD CHM carrier

20/16

88 36; 3981.07 Fixation target

3.32, 3.14 2.38 1.07 [0.02] 41.64

3 26/F OS CHM carrier

20/20

85 38; 6309.57 Fixation target

2.17, 5.52 2.97 1.8 [0.03] 48.14

4 27/F OS CHM carrier

20/20

85 36; 3981.07 Fixation target

3.56, 8.92 2.72 0.82 [0.01] 45.33

5 37/F OD ADRP 20/16

89 37; 5011.87 Fixation target

1.95, 2.95 0.28 0.36 [0.01] 6.87

6 45/F OD ADRP 20/25

83 35; 3162.28 Peak cone density

N/A -0.97 0.00 -30.40

7 38/F OD Simplex RP 20/32

81 34*; 2511.89* Fixation target

4.71, 2.54 5.88 8.08 [0.13] 69.90

8 48/F OS Simplex RP 20/25

80 34*; 2511.89* Fixation target

1.09, 0.89 3.07 7.57 [0.13] 50.85

9 40/M

OD Simplex RP 20/20

83 37; 5011.87 Fixation target

4.20, 1.66 -0.20 0.40 [0.01] -5.34

10 28/F OS Simplex RP 20/25

82 39; 7943.28 Fixation target

3.66, 6.24 2.61 1.62 [0.03] 44.37

11 32/F OD Simplex RP 20/40

62* 12*; 15.85* Fixation target

1.61, 2.37 5.44 0.90 [0.01] 65.64

Page 25: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

14

12 40/F OD Simplex RP 20/16

89 37; 5011.87 Fixation target

3.76, 8.55 0.29 0.36 [0.01] 7.04

13 30/M

OD Multiplex RP

20/25

81 34*; 2511.89* Fixation target

4.43, 2.67 3.06 2.49 [0.04] 49.17

14 30/M

OD XLRP 20/50

63* 25*; 316.23* Fixation target

1.65, 3.50 2.37 0.76 [0.01] 41.41

15 49/F OS XLRP carrier

20/12.5

93 35; 3162.28 Fixation target

6.23, 3.30 -0.32 0.85 [0.01] -8.98

16 20/F OS XLRP carrier

20/50

67* 32*; 1584.89* Fixation target

5.49, 2.98 7.08 1.44 [0.02] 72.95

17 18/F OD NARP 20/50

65* 32*; 1584.89* Fixation target

9.90, 4.08 5.01 0.69 [0.01] 63.19

18 22/F OS NARP 20/25

79* 35; 3162.28 Fixation target

1.72, 2.65 3.90 0.51 [0.01] 55.82

19 50/F OS NARP 20/50

65* 27*; 501.19* Fixation target

8.67, 3.07 7.61 0.70[0.01] 74.61

20 27/F OS NARP 20/16

90 38; 6309.57 Fixation target

3.84, 3.63 2.55 0.40 [0.01] 43.36

21 26/M

OS USH2 20/25

77* 33*; 1995.26* Peak cone density

N/A 2.29 0.00 40.30

22 34/M

OD USH2 20/20

85 36; 3981.07 Fixation target

1.53, 1.62 2.15 0.75 [0.01] 38.86

23 33/M

OD USH2 20/20

85 39; 7943.28 Peak cone density

N/A -0.41 0.00 -11.47

24 29/F OS USH2 20/30

80 32*; 1584.89* Peak cone density

N/A 2.33 0.00 40.83

25 20/M

OS USH3 20/16

90 36; 3981.07 Fixation target

3.60, 2.40 1.86 0.62 [0.01] 35.04

26 25/F OD USH3 20/20

85 35; 3162.28* Fixation target

2.77, 3.33 -0.86 0.00 [0.05] -26.47

Table 2.1 | Summary of clinical and structural characteristics of patients studied. BCVA, best-corrected visual acuity; ETDRS, early treatment of diabetic retinopathy score, expressed as number of letters correctly identified; dB, decibels; PRL, preferred retinal locus for fixation; SD, standard deviation; SDx, horizontal standard deviation of fixation; SDy, vertical standard deviation of fixation; OD, right eye; OS, left eye; M, male; F, female; RP, retinitis pigmentosa; XL, X-linked; NARP, neurogenic weakness, ataxia, retinitis pigmentosa; USH, Usher syndrome. *Abnormal values for ETDRS score and foveal sensitivity. Adapted from Ratnam et al., 2013.

2.3.3 Clinical examination

BCVA was measured using a standard eye chart according to the Early Treatment of

Diabetic Retinopathy Study (ETDRS) protocol (“Early Treatment Diabetic Retinopathy

Study Research Group. Photocoagulation for diabetic macular edema: Early Treatment

Diabetic Retinopathy Study report number 1.,” 1985). Foveal sensitivity thresholds were

Page 26: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

15

measured using a Goldmann III stimulus on a white background (10.03 cd/m2) and

exposure duration of 200 ms (Humphrey Visual Field Analyzer HFA II 750-6116-12.6; Carl

Zeiss Meditec, Inc., Dublin, CA). Foveal sensitivity was expressed in logarithmic decibel

scale (dB = 10 x log(1/Lambert) and linearly (1/Lambert).

2.3.4 AOSLO image acquisition and cone structure analysis

Pupils were dilated with 1% tropicamide and 2.5% phenylephrine before AOSLO imaging.

High-resolution AOSLO images of the macula were obtained for the 26 patients and 37 age-

similar visually normal subjects. For patients measured at the University of California,

Berkeley (n=22), the PRL was determined by recording 10-second videos during which

patients looked at a fixation dot delivered via the AOSLO scanning raster. The mean and

standard deviation (SD) locations of the PRL were analyzed to quantify fixational stability.

For patients assessed at the Medical College of Wisconsin (n=4), PRL analysis was

unavailable and hence it was assumed that patients fixated with the foveal location with

maximum cone density. The PRL and location of maximum cone density are similar but

have been shown to differ by 6-10 minutes of arc (arcmin) of visual angle (Li, Tiruveedhula,

& Roorda, 2010; Putnam, Hofer, Chen, & Williams, 2005; Wilk et al., 2017). For each patient,

the eye in which unambiguous cone mosaics could be visualized closest to the PRL was

chosen for further analysis. Custom software was used to quantify cone spacing using

previously described methods (Duncan et al., 2007), and cone spacing measurements for

patients were compared with those of 37 visually normal subjects. For controls, the foveal

center (eccentricity = 0°) was defined as the location of peak foveal cone density when

known (n=11); for the remaining 26 normal subjects, the foveal center was identified as the

PRL. Cone locations in control subjects were measured as eccentricity in degrees relative to

PRL or location of peak cone density; cone spacing in patients was measured close to or at

the PRL (mean [SD] eccentricity, 0.02 [0.03] degree; maximum eccentricity, 0.13 degree).

Deviation from normal mean cone spacing was calculated as a Z-score, or the number of

SDs from the mean. Z-scores between -2 and 2 were considered normal.

Cone spacing was converted to cone density using a previously published method (Duncan

et al., 2007). Cone density was computed this way for two reasons. First, due to lower

image quality at the fovea for reasons mentioned earlier, not all foveal cones are visible in

the AOSLO image. As such, densities based on subjective identification of visible cones will

likely be underestimated (see Figure 2.1). Second, fine spatial tasks are likely mediated by

small patches of contiguous cones (Geller, Sieving, & Green, 1992), so our method of

estimating cone density within small patches is adequate. Cone density (CD) was converted

to fraction of cones (FOC) using the equation:

Page 27: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

16

𝐹𝑂𝐶 =𝐶𝐷𝑠𝑢𝑏𝑗𝑒𝑐𝑡

𝐶𝐷𝑛𝑜𝑟𝑚𝑎𝑙,𝑎𝑣𝑒𝑟𝑎𝑔𝑒

[2.1]

FOC was used to calculate the percentage of cones below average, or the difference in the

patient’s cone density as a certain eccentricity compared to the average value from the

normal controls. The relevant equation is:

% 𝐶𝑜𝑛𝑒𝑠 𝐵𝑒𝑙𝑜𝑤 𝐴𝑣𝑒𝑟𝑎𝑔𝑒 = 100(1 − 𝐹𝑂𝐶) [2.2]

Negative percent values indicate cone density was greater than average. Cone spacing Z-

scores within 2 SD at the foveal center correspond to cone densities up to 36.7% below or

above the normal mean, which may be attributable to the high individual variability in

human foveal cone density (Ahnelt, 1998; Chui, Song, & Burns, 2008; Chui, Song, & Burns,

2008; Curcio, Sloan, Kalina, & Hendrickson, 1990; Li et al., 2010; Song, Chui, Zhong, Elsner,

& Burns, 2011). Therefore, percentage of cones below average does not necessarily

indicate percentage of cone loss; Z-scores exceeding 2 however strongly suggest foveal

cone loss has occurred.

2.3.5 Statistical analysis

Z-scores were compared to ETDRS scores and foveal sensitivity using Spearman rank

correlation (ρ), which computes the correlation between the ranked order of variables and

is unaffected by the nonlinearity of monotonic relationships between variables. P values

were calculated using the Holm adjustment; P < 0.05 was considered statistically

significant.

Percentage of cones below average was plotted against VA and foveal sensitivity. The cone

percentage threshold after which the ETDRS score dropped below 85 letters (~20/20) and

80 letters (~20/25) (Ferris, Kassoff, Bresnick, & Bailey, 1982) was determined. Thresholds

were similarly determined for foveal sensitivities below normal values (logarithmic scale:

<35 dB; linear scale: <3162.28 1/Lambert). Data were fit to a locally weighted scatterplot

smoothing curve with 95% confidence intervals (CI) generated using the cases bootstrap

method (Davidson & Hinkley, 1997).

2.4 Results

Clinical characteristics of the patients are summarized in Table 2.2. Patients (18 female and

8 male) ranged in age from 17 to 50 years (mean [SD] age, 31.9 [9.6] years). Visually

normal subjects (20 female and 17 male) were similar in age (age range, 14-58 years; mean

[SD] age, 31.3 [12.2] years). Patients’ ETDRS acuity ranged from 93 to 62 letters (mean [SD]

acuity, 80.5 [8.9] letters), and foveal sensitivities ranged from 39 to 12 dB (mean [SD]

sensitivity, 33.8 [5.5] dB). Normal ETDRS acuity ranged from 93 to 80 letters, and normal

Page 28: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

17

foveal sensitivity ranged from 39 to 35 dB. Patients’ mean (maximum) fixational SD was

3.84 (9.90) arcmin for the horizontal meridian and 3.63 (8.92) arcmin for the vertical

meridian, which is similar to observations in normal subjects (Barlow, 1952; Ditchburn,

1973; Putnam et al., 2005; R. M. Steinman, Haddad, Skavenski, & Wyman, 1973). Cone

selections were made on average within 1 SD of the PRL, with the exception of patients 7

and 8. Cone spacing Z-scores ranged from -0.97 (30.4% cones above the normal average) to

7.61 (74.6% cones below the normal average). Figure 2.1 shows examples of foveal cone

mosaics with varying Z-scores.

Spearman’s rank

correlation

P-value (α

= 5%)

%-Cones-Below-Average

Visual acuity (ETDRS Score) -0.60 0.003 For <85 letters (20/20 VA):

24.82%

(95% CI = 1.77- 43.59%)

For <80 letters (20/25 VA):

51.75%

(95% CI = 34.16- 65.83%)

Foveal Sensitivity, Logarithmic

-0.47 0.017 51.66%

(95% CI = 17.90- 67.27%)

Foveal Sensitivity, Linear -0.47 0.017 61.85%

(95% CI = 46.58- 69.90%)

Table 2.2 | Summary of statistical analyses: correlation between cone spacing Z-scores and visual function. Foveal sensitivities are in logarithmic (decibel) and linear (1/Lambert) scales. P < 0.05 is statistically significant; %-Cones-Below-Average, upper limits of cone density change before abnormal values were observed for ETDRS acuity (<85 letters and <80 letters) and foveal sensitivity (logarithmic, <35 decibels; linear, <3162.28 1/Lambert). Adapted from Ratnam et al., 2013.

Page 29: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

18

Figure 2.1 | AOSLO images of foveal cone mosaics. 0.5° x 0.5° AOSLO images of foveal cone mosaics in six subjects’ eyes, centered around the preferred retinal locus of fixation (white dot). Patients arranged by increasing % cones below average from left to right and top to bottom. Red crosshairs indicate cone selections used to calculate cone spacing z-scores and percentage of cones below average, with blue diamonds indicating the average location of cone selections. Green and orange lines indicate 1 standard deviation of fixation from the average PRL location in the horizontal and vertical directions, respectively. White scale bar = 0.25°. Adapted from Ratnam et al., 2013.

Visual acuity (Figure 2.2) and foveal sensitivity (Figure 2.3) are plotted against Z-scores

and percentage of cones below average; Table 2.2 summarizes the statistical analyses. Cone

spacing Z-scores and ETDRS acuity were significantly correlated (ρ= -0.60, P= 0.017). Cone

percentage reductions before abnormal acuity was observed were 24.82% (95% CI, 1.77-

43.59%) for fewer than 85 letters and 51.75% (95% CI, 34.16-65.83%) for fewer than 80

Page 30: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

19

letters (Figure 2.2). Cone percentages below average for abnormal logarithmic and linear

foveal sensitivities were 51.66% (95% CI, 17.90-67.27%) and 61.85% (95% CI, 46.58-

69.90%), respectively (Figure 2.3).

Page 31: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

20

Page 32: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

21

Figure 2.2 | Visual acuity as a function of cone spacing. (Top) Visual acuity measured as ETDRS letter scores correlates with cone spacing Z-scores. Vertically-shaded grey region indicates range of normal Z-scores (within ±2); horizontally-shaded region indicates normal range of visual acuity (100-85 letters). (Center) Visual acuity plotted against percentage of cones below average. Vertically-shaded grey region indicates % cone values corresponding to the normal range of Z-scores; horizontally-shaded grey region indicates normal range of visual acuity. Red line indicates cone percentage after which ETDRS scores fall below 85 letters (20/20 acuity); red shaded region indicates 95% confidence intervals (95% CI). (Bottom) Percentage of cones below average with threshold value and 95% CI for EDTRS scores below 80 letters (20/25 acuity). Adapted from Ratnam et al., 2013.

Figure 2.3 | Foveal sensitivity as a function of cone spacing. (Top) Foveal sensitivity in logarithmic (decibel; left column) and linear (1/Lambert; right column) scales do not correlate with cone spacing Z-scores; vertical grey regions indicate normal range of Z-scores (within ±2) and horizontal grey regions indicate normal range for sensitivity. (Bottom) Foveal sensitivity plotted against percentage of cones below average. Red vertical lines and shaded regions indicate cone percentage reductions that correspond to foveal sensitivity and 95% confidence intervals (95% CI) after which sensitivity in decibel (<35 dB) and 1/Lambert units (<3162.28 1/Lambert) become abnormal. Adapted from Ratnam et al., 2013.

Page 33: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

22

2.5 Discussion

This study is the first cross-sectional assessment of in vivo foveal cone structure and

clinical measures of visual function in patients with inherited retinal degenerations. Earlier

AOSLO studies have compared cone structure metrics in normal and diseased eyes, yet

none reported correlations between these measures and visual function (Chen et al., 2011;

Choi et al., 2006; Duncan et al., 2007, 2012; Duncan, Ratnam, et al., 2011; Duncan, Talcott,

et al., 2011; Li & Roorda, 2007; Merino et al., 2011; Ratnam, Västinsalo, Roorda, Sankila, &

Duncan, 2013; Rha et al., 2010; Roorda et al., 2007; Talcott et al., 2011; Wolfing, Chung,

Carroll, Roorda, & Williams, 2006; Yoon et al., 2009). Our study reports a significant

correlation between increased AOSLO cone spacing Z-scores and decreased VA and foveal

sensitivity at the fovea. Near-normal VA (>20/40) and normal foveal sensitivity were

observed when cone density was up to 52-62% below the normal mean.

2.5.1 Normal variability of human foveal cone density

This study reports percentage of cones below normal, rather than cone loss, due to the high

individual variability in foveal cone density, which precludes such a metric when

comparing density across subjects (Ahnelt, 1998; Chui et al., 2008; Chui et al., 2008; Curcio

et al., 1990; Li et al., 2010; Song et al., 2011). Cone spacing Z-scores within 2 SD were

considered normal; when converted to density, this value corresponded to a cone

percentage decrease of approximately 36.7% from the normal mean.

Histologic evidence suggests that in spite of this high intersubject variability in cone

density, the total number of cones near the foveal center is relatively constant (Curcio et al.,

1990). Age-dependent changes in foveal cone density have been previously reported

(Panda-Jonas, Jonas, & Jakobczyk-Zmija, 1995; Song et al., 2011). Although our patients and

normal controls were age-matched for the purpose of this study; comparison of patient and

normative data by decade may have further reduced variability effects. The limited number

of subjects in our normative dataset prevented more specific age-related comparisons.

Despite these limitations, our calculated threshold for cone densities below which visual

function became abnormal was lower than the lower bound of cone densities attributable

to normal variability (~36.7% cones below average), with the exception of ETDRS acuity

less than 85 letters (threshold of 24.8% cones below average; Table 2.1). Although these

results do not provide exact measurements of cone loss, they suggest that VA and foveal

sensitivity are preserved when cone density is significantly lower than normal.

2.5.2 Comparison of AOSLO normative cone measures with histologic data

AOSLO cone spacing measures at the foveal center were converted into density and

compared with histologic data from seven subjects (mean [SD] histologic peak foveal cone

Page 34: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

23

density, 199,200 [87,200] cones/mm2, range, 98,200-324,100 cones/mm2) by Curcio et al.

(Curcio et al., 1990). To convert values from angular cone density to retinal distances, the

assumption of 289 µm/deg was used (Bennett, Rudnicka, & Edgar, 1994; Merino et al.,

2011). Mean AOSLO foveal density was hence 127,774.27 cones/mm2 (95% CI, 85,297.41-

235,152.41 cones/mm2), which is within 1 SD of, yet reduced from, the data by Curcio et al.

The source of this disparity may be the larger sample size of the AOSLO normative data set

(n = 37), which may be less susceptible to variability of a smaller dataset. Additionally, the

PRL was assumed to coincide with the anatomical foveal center for 26 of the 37 normal

AOSLO eyes, so the mean density value was likely lower than if the peak cone location had

been used, as was done for the histologic data. However, since cone spacing measurements

for the present study were made at or near the PRL, it was appropriate that the normative

database was similarly collected relative to the PRL.

2.5.3 Uncertainty of the relationship between PRL and the location of peak

cone density

In four patients for whom the PRL was unknown, the location of peak cone density was

used for analysis. Although the PRL is typically displaced from the location of peak cone

density (Li et al., 2010; Putnam et al., 2005; Wilk et al., 2017), the eye’s optical blur reduces

VA below the theoretical sampling limit of foveal cones (Marcos & Navarro, 1997),

lessening the effect of absolute cone density on visual function. Weymouth and colleagues

(Weymouth, Hines, Acres, Raaf, & Wheeler, 1928) mapped grating acuity in 11-arcmin

intervals within the fovea and found that acuity was highest at the PRL, suggesting that the

location of highest cone density does not necessarily indicate maximum function.

Therefore, the substitution in the present study of peak cone density for comparison with

visual function is appropriate, although it may underestimate the extent of cone density

reductions occurring at the PRL. The four patients had peak cone densities of 40.83%

below to 30.40% above the mean foveal density of visually normal subjects; because these

were derived near the PRL rather than the location of peak cone density, these values likely

reflect a lower bound of cone changes occurring at fixation.

2.5.4 AOSLO density measurements represent an upper bound of structural

changes

In the present study, cone spacing was used to quantify foveal cone structure. Cone spacing

represents a conservative measure of cone mosaic integrity (Duncan et al., 2007) since

reliable spacing estimates can be made even if not all cones have been identified within the

retinal region. Since the spacing to density conversion assumes a close-packed hexagonal

mosaic, the cone density measures reported represent an upper limit of percentage of cone

density differences from normal. Worded differently, actual cone densities are likely lower

Page 35: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

24

than what is reported. Nevertheless, cone density thresholds observed in this study are in

agreement with earlier studies in which significant cone loss was predicted to be necessary

to cause measurable reductions in visual function. By analyzing the psychometric functions

of patients with Stargardt disease, Geller and Sieving (Geller & Sieving, 1993) estimated

that 90% of cones would be lost before significant functional changes occurred in these

subjects. Additionally, Eagle and colleagues (Eagle, Lucier, Bernardino, & Yanoff, 1980)

reported that a patient with juvenile macular degeneration maintained 20/30 acuity prior

to his death, in spite of significant foveal deterioration. Seiple et al. (Seiple, Holopigian,

Szlyk, & Greenstein, 1995) used pixel blanking in optotypes to simulate foveal cone

dropout and determined that a loss of 80% of foveal cones was necessary to reduce acuity

below 20/40. These results support our observations that VA is resilient to significant

changes in foveal cone topography.

2.5.5 Longitudinal studies would facilitate accurate assessments of

degeneration in individual subjects

The cross-sectional design of this study precluded tracking of longitudinal structural and

functional changes in individual subjects. Because normal intersubject variability in foveal

cone density prevents measurement of absolute photoreceptor loss, a longitudinal follow-

up to the present study would facilitate accurate tracking of degenerative changes

measured structurally and functionally. A longitudinal study of AOSLO cone measures

published by Talcott et al. (Talcott et al., 2011) tracked three patients with inherited retinal

degenerations treated with sustained-released ciliary neurotrophic factor (CNTF) over 30

to 35 months. Cone spacing increased by 2.9% and density decreased by 9.1% more per

year in sham-treated versus CNTF-treated eyes, but VA and visual field sensitivity

remained stable. These findings indicated preserved visual function despite significant

cone loss in sham-treated eyes, and a longitudinal follow-up (summarized in section 2.7) to

the present study showed similar findings.

2.5.6 Intrasubject variability of psychophysical measures

Due to the small size of the present study’s dataset, Spearman rank correlation, which is

more robust and insensitive to the effects of outliers than regression analysis, was used to

evaluate correlations between cone spacing and visual function. The noise in the current

dataset may be partially attributed to intrasubject variability in psychophysical

examinations, which is worsened in patients with increased disease severity (Bittner,

Ibrahim, Haythornthwaite, Diener-West, & Dagnelie, 2011; Grover, Fishman, Gilbert, et al.,

1997; Kiser, Mladenovich, Eshraghi, Bourdeau, & Dagnelie, 2005). This amplified

inconsistency with advanced stages of disease may be due to the irregular response of

remaining foveal cones to light stimulation. Additionally, variations in test procedures (e.g.,

Page 36: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

25

chart luminance, test distance, and examiner instructions) may also increase statistical

error (Arditi & Cagenello, 1993). Although the ETDRS scoring protocol used in this study

provides high test-retest ability (Arditi & Cagenello, 1993; Vanden Bosch & Wall, 1997),

trained, visually normal subjects can still have inter-test variability of 3.5 to 5 letters (Arditi

& Cagenello, 1993; Bailey & Lovie, 1976; Elliott & Sheridan, 1988). This variability

reinforces the need for more objective measures such as cone structure for assessing

retinal health.

2.5.7 Relationship between structural measures and VA

The present study found a significant relationship between foveal cone spacing and VA,

which is consistent with previous structure-function correlations using optical coherence

tomography (OCT). Previous reports have shown significant correlations between VA and

foveal thickness (Ergun et al., 2005; Sandberg, Brockhurst, Gaudio, & Berson, 2005; Witkin

et al., 2006), but they did not determine the extent of degeneration before abnormal values

were observed psychophysically. Ergun and colleagues (Ergun et al., 2005) found

significant linear relationships between VA and foveal thickness (R2 = 0.51, P = 1x10-4).

Sandberg et al. (Sandberg et al., 2005) compared ETDRS acuity and foveal thickness in RP

patients using multiple models and found that second-order polynomial models provided

the best fits, accounting for a decline in VA at smaller and larger retinal thicknesses

because of cone loss and edematous thickening, respectively. They predicted a four-year

time course before significant structural changes were observed with OCT, which is similar

to the time needed to observe significant changes in ETDRS acuity (0.9 letters/year x 4

years = 3.6-letter decrease over 4 years), which is within the threshold range for significant

acuity change in normal subjects (3.5-5 letters; (Arditi & Cagenello, 1993; Bailey & Lovie,

1976; Elliott & Sheridan, 1988)). Talcott et al. (Talcott et al., 2011) reported significant

reductions in cone density over 30 to 35 months in the absence of VA changes, suggesting

that direct visualization of the cone mosaic may provide an earlier measure of structural

changes.

2.5.8 Relationship between structural measures and foveal sensitivity

The present work found a significant correlation between cone spacing and foveal

sensitivity. Cone density thresholds were 52-62% below normal before abnormal values

were seen in sensitivity. This inconsistency is likely due to inability of perimetry stimuli to

detect subtle changes in photoreceptor topography. The Goldmann III stimulus has a size of

0.12 degree2 (432 arcmin2) on the retina from a distance of 0.33 meter (m) (Vislisel, Doyle,

Johnson, & Wall, 2011). Since the diameter of a foveal cone is 0.5 arcmin (Putnam et al.,

2005), approximately 2200 foveal cones would sample a Goldmann III stimulus. Since each

foveal cone corresponds to a single receptive field (Dacey, 1993), functionally normal cones

Page 37: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

26

may conceal dysfunctional regions. Smaller stimulus sizes such as the Goldmann I (0.0075

degree2 at 0.33 m) may increase sensitivity to subtle structural abnormalities, but these

benefits may be compromised by the increased test-retest variability of smaller stimuli

(Vislisel et al., 2011). Since AOSLO images showed 52-62% decrease in foveal cones before

abnormal sensitivity was observed, these results suggest that structural measures may

provide an earlier and more objective measure of degeneration.

2.5.9 AOSLO-based microperimetry for single-cell functional testing

Although AOSLO cone measures assess the integrity of the cone mosaic, they do not

provide information on the health of individual cones. For AOSLO imaging to become a

comprehensive and objective measure of disease progression, the structure-function

relationship for individual foveal cones needs to be assessed. Makous and colleagues

(Makous et al., 2006) used 0.75-arcmin AO-corrected stimuli to identify microscotomas and

an estimated 30% cone loss in a deuteronopic patient with normal VA and visual field. This

finding suggests that single-cone microperimetry may be necessary for evaluating subtle

functional changes in the cone mosaic; to facilitate testing individual cone function, Tuten

et al. (Tuten et al., 2012) have developed AOSLO-based microperimetry with real-time eye

tracking. AOSLO microperimetry thus facilitates targeted, longitudinal functional testing of

individual cones. Recent work using AOSLO-based microperimetry has shown visual

sensitivity within retinal areas of ambiguous cone morphology, suggesting that single-cell

functional testing is important for quantifying the health of cone photoreceptors within

retinal lesions (Tu et al., 2017; Wang et al., 2015).

2.5.10 Structural measures may provide more reliable predictors of foveal

degeneration than visual fields

For rod-cone degenerations in which cone loss begins in the periphery and encroaches

inwards, natural history studies predict half-life times of Goldmann V-4e field loss ranging

from 5 to 15 years (Holopigian et al., 1996; Iannaccone et al., 2004). Alexander and

colleagues reported that VA loss in RP patients occurred following parafoveal

photoreceptor degeneration, after which inner segment enlargement increased foveal cone

spacing and decreased foveal sampling resolution (Alexander et al., 1992). Madreperla et

al. showed that clinically significant VA loss (<20/40) in RP patients occurred after the

visual field narrowed to a 15° radius, suggesting that visual field radius could be a useful

marker for the onset of foveal dysfunction (Madreperla, Palmer, Massof, & Finkelstein,

1990). This prognosis however requires knowledge of the rate of visual field decay, which

varies due to factors such as visual field loss pattern (Grover, Fishman, Anderson,

Alexander, & Derlacki, 1997), critical age (Fishman, Bozbeyoglu, Massof, & Kimberling,

2007; Iannaccone et al., 2004), disease genotype (Sadeghi, Eriksson, Kimberling, Sjöström,

Page 38: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

27

& Möller, 2006; Sandberg, Rosner, Weigel-DiFranco, Dryja, & Berson, 2007), and

environmental and dietary factors (Hartong, Berson, & Dryja, 2006; Sunga & Sloan, 1967).

Additionally, the rates of field loss can fluctuate over an individual’s lifetime (Sunga &

Sloan, 1967). Because of these variations, the rate of visual field loss cannot be reliably

predicted as a marker for VA decline. Instead, structural measures such as those provided

by AOSLO may be used as an earlier indicator of parafoveal cone changes than visual

function, enabling disease monitoring and treatment intervention before the fovea exhibits

signs of degeneration.

2.5.11 Less commonly used clinical measures of function may be more

sensitive to structural changes than VA or sensitivity

The purpose of the present study was to show that clinical measures of visual function,

specifically VA and foveal sensitivity, are insensitive indicators of cone structural integrity.

However, other psychophysical tests may provide improved sensitivity. Conventional tests

such as ETDRS charts or Landolt rings use high-contrast figures to assess visual

dysfunction, which may not be as sensitive to foveal degradation as contrast sensitivity

tested at specific spatial frequencies. Akeo et al. (Akeo et al., 2002) reported systematic

correlations between Landolt ring VA and contrast sensitivity at lower spatial frequencies

(1.5, 3.0, and 6.0 cycles/degree) in RP patients with greater than 20/50 VA. At 18

cycles/degree however, a subset of these patients with 20/25 acuity had significantly

reduced contrast sensitivity (<15 cycles/degree). Lindberg et al. (Lindberg et al., 1981)

showed similar contrast sensitivity reductions at higher frequencies in patients with RP

undetected by Snellen acuity, suggesting that abnormalities in patients with normal VA

may be detectable with contrast gratings at high spatial frequencies. Despite these

advantages, contrast sensitivity is difficult to implement routinely since test distance,

lighting, and duration of grating presentation must be precisely controlled (Lindberg et al.,

1981) and is more affected than conventional VA by ocular conditions such as cataract

(Elliott, 1993).

In conclusion, direct, high-resolution images of cone structure such as those provided by

AOSLO may provide more sensitive and reliable indicators of foveal degeneration than VA

and foveal sensitivity. These findings support the use of AOSLO images as an outcome

measure of disease progression and suggest that treatment intervention is best done

before measurable functional loss occurs, at which point significant structural changes may

already be present. Large cross-sectional and longitudinal assessments of patients are still

necessary for better understanding the relationship between cone structure and standard

measures of visual function.

Page 39: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

28

2.6 Summary

The fovea is the most crucial retinal location for vision due to its high spatial resolution and

hence importance in everyday tasks. In rod-cone degenerations during which central vision

is initially spared, visual acuity is preserved until late stages of disease in spite of

observable cone abnormalities (Akeo et al., 2002; Alexander et al., 1986; Birch, Sandberg, &

Berson, 1982; Lindberg et al., 1981; Wolkstein et al., 1980). Intrasubject variability in

psychophysical techniques such as VA and sensitivity preclude accurate quantification of

foveal degeneration and early therapeutic intervention. More objective measures of vision

loss, such as the direct visualization of foveal cones, would provide a more reliable

assessment of degeneration. In the present study, AOSLO-derived cone spacing and density

measures were compared to best-corrected VA and foveal sensitivity in 26 patients with

rod-cone degenerations. Cone density was reduced to up to 62% below normal before VA

and sensitivity reached abnormal levels, suggesting that direct, objective measures of cone

structure may be more sensitive indicators of disease severity.

2.7 Longitudinal follow-up study and AOSLO-based acuity measures

Since the preceding cross-sectional study was inadequate for measuring intrasubject

changes in acuity with degeneration, a longitudinal follow-up study was necessary to

quantify functional changes with respect to cone loss. Saud et al. (Saud et al., 2017)

compared foveal cone spacing with BCVA in 15 eyes of 11 patients with inherited retinal

degenerations and 10 eyes of 5 normal subjects monitored longitudinally over periods

ranging from 10 months to 5 years. Similar to the current study, cone spacing

measurements were made as close to the PRL as possible. There was no significant change

in ETDRS acuity or foveal sensitivity across imaging sessions in normal subjects. In

patients, however, significant increases in cone spacing (mean Z-score = +0.56) were

observed while acuity (mean change, 0.13 letters; 95% CI, - 1.2 - 1.7) and foveal sensitivity

(mean change, -0.6 dB; 95% CI, - 1.5 - 0.3) remained stable, suggesting that clinical

measures of function inadequately reflect retinal structural changes.

Both the cross-sectional and longitudinal studies suggest that the relationship between

foveal structure and psychophysical measures is not linear, which may be partially

attributed to the redundancy or oversampling of foveal cones in relation to clinical

measures of ‘normal’ function. Given reported foveal cone densities (Curcio, Sloan, Kalina,

& Hendrickson, 1990), a loss of 40% of foveal cones is still adequate for obtaining 20/20

acuity levels (Geller et al., 1992). Additionally, the direct relationship between visual acuity

and cone spacing is confounded by the presence of ocular aberrations, which blur the

image on the retina and effectively make clinical acuity a blur-limited rather than sampling-

limited task.

Page 40: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

29

Since the AOSLO is a robust tool for compensating for ocular-blur and delivering near-

diffraction limited stimuli to the retina, AOSLO-based measures of function would provide a

more systematic way for measuring functional changes at the level of individual cone

photoreceptor cells. We have recently implemented AOSLO-based acuity tests to better

gauge how spatial resolution is affected by subtle changes in the cone topography of

degenerative retinas (Loumou et al., 2016). AOSLO-based acuity measures thus allow a

more precise measure of functional changes than clinical-based tests.

It is important to mention that visual acuity is not necessarily a static task. Fixational eye

movements, or the normal jitter of the eye, perpetually moves an otherwise static retinal

image across multiple photoreceptor cells, shifting spatial signals into the temporal

domain. Recent work by Rucci et al. has shown that the dynamic signal conferred by eye

movements can improve the discriminability of high spatial frequencies (Rucci, Iovin,

Poletti, & Santini, 2007). In the next chapter, we investigate whether this benefit of

fixational eye movements extend to spatial frequencies at the retinal sampling limit, which

could help explain how acuity is preserved despite considerable cone loss.

2.8 Acknowledgements

The efforts described in this chapter with the exception of section 2.7 were published as a

manuscript in Investigative Ophthalmology and Visual Science in August 2013 with the

invaluable assistance of co-authors Drs. Joseph Carroll, Travis Porco, Jacque Duncan, and

Austin Roorda. The longitudinal follow-up study described in section 2.7 was conducted by

Asma Saud under direct guidance from the current author, with the assistance of Panagiota

Loumou, Shane Griffin, Jia Qin, Austin Roorda, Travis Porco, and Jacque Duncan. The

current author developed the AOSLO-based acuity software and protocol cited in Loumou

et al.; she also trained the personnel who used the system and participated in collection of

some of the earlier data.

Page 41: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

30

Chapter 3

Benefits of retinal image motion at the limits

of spatial vision

Page 42: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

31

Chapter 3

Benefits of retinal image motion at the limits of spatial vision

3.1 Abstract

Even during fixation, our eyes are constantly in motion, creating a dynamic signal in each

photoreceptor cell. Neuronal processes can synthesize these temporal signals to serve

spatial vision, but it is unknown how our finest visual acuity is maintained during this

process. We used an adaptive optics scanning laser ophthalmoscope to control the

spatiotemporal signal at the cone photoreceptor scale in human observers during a visual

discrimination task under motion conditions in which normal, cancelled, or manipulated

retinal image motion occurred. When stimuli moved, acuities were 25% better than in the

case of stabilized presentation, regardless of whether the motion was self-induced, a

playback of similar motion, or an external simulation of cone activation patterns. We argue

that in our experimental condition, the visual system is able to synthesize a higher

resolution percept from multiple views of a poorly resolved image; these results may

extend the current understanding of how fixational eye motion affects high acuity vision.

3.2 Introduction

Even when fixating on a static object, our eyes are constantly moving. As a result, the

human visual system has to incorporate methods that transform a dynamic retinal signal

into a stable, acute percept. Classic theories of visual acuity postulated that fixational eye

movements (FEM), small mostly involuntary movements of the eye, may enhance fine

spatial detail through a dynamic sampling process (Ahissar & Arieli, 2012; Arend, 1973;

Averill & Weymouth, 1925; Marshall & Talbot, 1942). Early experiments, limited by

available technology, were unable to support these hypotheses (Kelly, 1979; Riggs, Ratliff,

Cornsweet, & Cornsweet, 1953; Tulunay-Keesey, 1960, 1982; Tulunay-Keesey & Jones,

1976). Recent work by Rucci et al. (Rucci et al., 2007) showed FEM benefit discrimination

of high spatial frequencies as high as 10 cycles/degree of visual angle. This benefit was

attributed to the equalization or “whitening” of spatial energy across the temporal domain

(Kuang, Poletti, Victor, & Rucci, 2012; Rucci et al., 2007), reducing the relative power of low

spatial frequencies in natural scenes. While spectral equalization can account for

improvements in perceptual contrast of retinal images resolvable by the cone mosaic

(Rucci & Victor, 2015), this benefit cannot readily predict discrimination improvement of

high-contrast images at the retinal sampling limit. Humans can resolve optotypes at the

20/10 acuity level and above (Rossi et al., 2010), suggesting that spatial resolution is not

necessarily limited by the structural sampling limit of the retina (Curcio, Sloan, Kalina, &

Hendrickson, 1990). The role of FEM in spatial resolution therefore remains unclear.

Page 43: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

32

With recent improvements in eye tracking and stimulus delivery using adaptive optics

scanning laser ophthalmoscopy (AOSLO), stimuli at the cellular scale can be delivered to

the retina with an accuracy of 0.15 arcmin, smaller than the diameter of a foveal cone

(Arathorn, Stevenson, Yang, Tiruveedhula, & Roorda, 2013; Harmening, Tuten, Roorda, &

Sincich, 2014). By also correcting for ocular blur, the ability to deliver near diffraction-

limited, retinally stabilized stimuli enables testing the effects of FEM on visual perception

at the cone photoreceptor level. We find that FEM improve discrimination performance for

poorly resolved images.

3.2 Methods

3.2.1 Subjects

In Experiments 1 and 2 (AOSLO-based), subjects were four adults (three males, one female;

ages 30-38 years), who had no known visual issues and were naïve to the purpose of the

study. Subject S4 was available for Experiment 1 only. A drop of 1% Tropicamide solution

was instilled in the test eye 15 minutes prior to testing for pupil dilation and cycloplegia.

For Experiment 3 (stimuli presented on LCD), eight additional subjects were recruited (six

naïve, two of the authors; five female, three male; ages 25-37 years). Informed consent was

obtained for each subject and experimental procedures adhered to the tenets of the

Declaration of Helsinki.

3.2.2 AOSLO imaging and stimulation

Adaptive optics imaging and micro-stimulation were used to present retina contingent

visual stimuli to targeted locations in cone-resolved retinae of human observers, a method

described in detail elsewhere (Arathorn et al., 2007; Rossi & Roorda, 2010b). The light

source was a supercontinuum laser (SuperK Extreme; NKT Photonics) with an infrared

imaging wavelength of 842 ± 25 nm (luminance of ~ 4 cd/m2). Retinal images were derived

by raster scanning a spot across the retina with horizontal and vertical scan rates of 16 kHz

and 30 Hz respectively. High order aberrations were measured with a Shack-Hartmann

wavefront sensor, and a 144-actuator, 5.5-micron stroke deformable MEMs mirror (Boston

Micromachines Corp) corrected the computed wavefront error. Corrected light was

captured with a photomultiplier tube, whose voltage output combined with positional

signals from scanning mirrors created 512 x 512 pixel videos with a framerate of 30 Hz. A 1

second retinal video was recorded with every stimulus presentation trial (500 trials per

condition per subject).

Stimuli were encoded into the scanning raster via 20 MHz acousto-optic modulation that

switched off the laser beam at points in the raster corresponding to the stimulus location,

producing stimulus decrements with high contrast (dark “E” on a red background).

Page 44: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

33

Michelson contrast between full-on and full-off stimulation was 99.9%. Diffraction reduced

the actual “E” contrast to between 60%-75%. Sampling resolutions for imaging and

stimulus projection ranged from 0.12 to 0.16 arcmin per pixel, depending on the specific

letter size chosen for each subject (see Results). The 30 Hz scanning rate has been shown to

elicit neural signals in LGN parvocellular neurons (Sincich, Zhang, Tiruveedhula, Horton, &

Roorda, 2009). Since AOSLO images provide unambiguous records of stimulus location

during delivery, proper stimulus encoding and stabilization were verified during

postprocessing. Retinal locations 0.8°-1.3° from the fovea along the horizontal meridian

(nasally in S1 and S4; temporally in S2 and S3) were selected for testing (Figure 3.1A-C).

3.2.3 Eye movement analysis and trial rejection

Fixational eye movements were analyzed offline from recorded AOSLO videos with a

sampling rate of 840 Hz (Stevenson, Roorda, & Kumar, 2010). Since microsaccades rarely

occurred during the 750-ms stimulus presentation (Figure 3.2), and to avoid confounding

effects due to microsaccadic suppression, trials in which microsaccades occurred where

removed from further analysis. Eye movement characteristics described in this study are

therefore due to drift and tremor only.

Proper stimulus delivery was verified by looking for distorted, improperly stabilized, or

otherwise incorrectly delivered stimuli in the AOSLO videos. Trials with misdelivered

stimuli were removed from further analysis.

3.2.4 Experiment 1: Natural versus manipulated retinal motion

In Experiment 1, we compared visual discrimination under two manipulated image motion

conditions (stabilized and incongruent) with natural viewing. In natural viewing, retinal

image motion was caused by ongoing FEM (Figure 3.3A, Figure 3.4A). In stabilized viewing,

stimulus presentation was modulated to be locked onto a targeted set of cones (Figure

3.3B, Figure 3.4B). Incongruent motion was derived by (1) compensating for habitual FEM

in real-time and (2) inducing net stimulus motion that followed a trajectory extracted from

subjects’ earlier eye motion traces. Since subjects showed idiosyncratic eye movements,

stimulus trajectories were selected randomly from a set of subjects’ earlier eye motion

traces. The resulting net movement of the stimulus relative to the retina was a path similar

to typical eye motion but incongruent to eye motion occurring at the time of presentation

(Figure 3.4C).

In a four-alternative-forced-choice task, subjects reported the orientation of an “E”

optotype with maximum negative contrast. The height and width of the letter were five

times the line thickness. Subjects gazed at a fixation laser target while attending to the

peripheral stimulus. The parafoveal location was chosen for two reasons: (1) to prevent the

Page 45: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

34

subjects from trying to follow a stabilized stimulus, which would appear to move relative to

the scanning raster, and (2) because image stabilization is better in locations just off the

fovea where cone photoreceptors are easier to resolve. The exact retinal location of

stimulus delivery was determined from AOSLO videos for each subject (Figure 3.1C).

Stimulus size was selected to be undersampled by the underlying cone mosaic, with an

average number of cones sampling the image at any given time being ~21, compared to 23

for a stimulus at the cone sampling limit. Illustrations and an equation demonstrating this

relationship are shown in Figure 3.1D-E. Subjects correctly discriminated about 40%-60%

of letters presented at this stimulus size in an earlier acuity experiment; this performance

range was selected to ensure subjects performed above the 25% guessing rate but below

the performance plateau. The stimulus gap size used was about 0.6 arcmin on average,

corresponding to a Snellen optotype of 20/12, which, for an “E”, has a dominant spatial

frequency of 50 cycles/degree. The stimulus was presented for 500 trials in each viewing

condition, pseudorandomly interleaved and divided into ten experimental blocks.

Comparison of stabilized and incongruent motion with natural viewing was done over two

successive experimental sessions.

3.2.5 Experiment 2: Contrast matching and discrimination performance

Experiment 2 consisted of a contrast matching task and discrimination task. For the

contrast matching task, subjects matched perceptual contrast for stimuli presented under

stabilized and incongruent viewing conditions; the purpose of this task was to quantify the

perceptual fading of the stabilized stimulus compared to the moving stimulus. Stimulus

duration, size, and retinal location were identical to those from Experiment 1 except that

square stimuli were used instead of optotypes (Figure 3.5A). The use of a square allowed

subjects to focus on stimulus contrast, rather than orientation, for the matching task. Two

vertically offset squares were simultaneously presented, one stabilized and the other

incongruently moving. Simultaneous presentation ensured that stimulus motion relative to

the AOSLO scanning raster were similar, so the stimuli would not be easily differentiated

other than by perceptual contrast. For each trial, subjects indicated which stimulus

appeared darker. The contrast of the stabilized square was fixed while the incongruently

moving square’s contrast was adjusted over repeated staircases to converge onto the value

for which it appeared similar to the stabilized square.

Seven one-down-one-up staircases were used for the contrast matching task. Staircases

terminated after seven reversals, and the threshold was calculated as the mean value from

the last four reversals. For the initial three staircases, stimulus contrast started at the

maximum physical contrast. The mean threshold value from these staircases was doubled

and then used as the initial value for the next three staircases. For the final staircase, the

starting value was the mean of the previous six staircase thresholds; contrast step intervals

Page 46: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

35

were made smaller as to provide finer resolution when determining the final contrast

value.

This reduced contrast value was used for the second part of Experiment 2. The protocol for

Experiment 1 was repeated except that discrimination of naturally moving, maximum

contrast and naturally moving, reduced contrast “E” optotypes were compared. Maximum

and reduced contrast conditions were pseudorandomly interleaved for 250 trials each.

3.2.6 Experiment 3: External computer-based simulation

To better understand the amount of visual information needed to benefit from image

motion, simulations of cone activation patterns were constructed and presented to a

separate subject cohort in a monitor-based discrimination experiment. Stimuli were

computed with custom written Matlab scripts (Figure 3.6A-B). Spatial representations of

cone apertures were constructed using randomly jittered hexagonal arrays with center-to-

center distances equaling those from cone outer segment distances (Curcio et al., 1990).

Cone apertures were represented by a two-dimensional Gaussian whose full-width at half-

maximum was 48% of the inner segment diameter for the mean eccentricity from the

AOSLO experiments (MacLeod, Williams, & Makous, 1992). A binary image of an at-

threshold “E” stimulus was spatially convolved with a two-dimensional Gaussian to

represent residual blur due to diffraction. The stimulus was then filtered by the simulated

cone array and summed across each cone aperture to generate activation values ranging

from 0 to 1 for each cone. The model cone array was then replaced by a Voronoi diagram

representing cone locations. Each Vornoi cell had a gray value representing the cone

activation value. The size of the simulated activation patterns was magnified on the

computer screen such that visual acuity did not limit performance on the discrimination

task. Eight subjects (six naïve, two of the authors) discriminated stimulus orientation via a

liquid-crystal display at 2 m viewing distance. Subject positioning was stabilized using a

head and chin rest. 150 trials of each static and dynamic viewing condition were presented

pseudorandomly interleaved. In static viewing, cone and stimulus locations were held

fixed. In dynamic viewing, the position of each cone relative to the stimulus was updated at

30 Hz based on motion paths drawn from the AOSLO experiments. All subjects were

presented with the same motion paths but in random sequences. Inter-trial progression

was self-paced and stimulus presentation time was 750 ms.

Page 47: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

36

Figure 3.1 | AOSLO micro-stimulation for projecting diffraction-limited stimuli to targeted retinal locations. (A) The AOSLO combines adaptive optics (AO) and high-speed scanning to record high-magnification videos of a human retina with cellular resolution. Optotypes (‘E’) are projected directly onto the retina by modulating the scanning beam with a high-speed acousto-optic modulator (AOM). In this particular configuration, the subject sees a dark letter within a red square (840 nm light) that is generated by the raster scan. Real-time eye tracking is used to guide the placement of the retinal stimulus within the raster scan, enabling the delivery to targeted retinal locations (stabilized) or along any predefined path across the retina, independent of eye motion. (B) On an exemplary fundus photo, the position of test locations (gray field), placed ~1 deg from the foveal center (asterisk), are shown. (C) One degree square AOSLO images of tested retinal locations in each subject (S1-4). Concentric circles show retinal regions with 5 and 10 arcminute radii centered on the stimulus delivery location. Insets show ~5 x 5 arcmin regions overlayed with a letter stimulus shown to the scale used in the experiments. (D-E) Stimulus feature size (D) during tests was smaller than the retinal Nyquist sampling limit (NC) determined by inter-cone distances (ICD) in all subjects (black dots in scatter plot). Adapted from Ratnam et al., 2017.

3.3 Results

3.3.1 Nature of FEM during the acuity task and quality of stabilization

AOSLO imaging and micro-stimulation enabled us to study the exact nature of FEM during a

given task (Figure 3.3A), as well as provide unambiguous records of tracking performance

(Figure 3.3B). FEM behavior shown here represent FEM that occur within 1-second epochs

of stimulus presentation and that occur when the eye is fixating on a target while attending

to a peripheral task. Additionally, analyzed trials do not include those containing

microsaccades or poorly tracked trials, which comprised between 10% and 20% of the

trials.

Page 48: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

37

Figure 3.2 | Distribution of microsaccades over experimental trials. Normalized distribution of microsaccades (MS) for all trials in the natural condition containing MS, which constituted 10-20% of total trials. Gray region indicates stimulus presentation time; dashed line indicates distribution if MS occurred uniformly across trial. Subjects S1-S3 show propensities for suppressing MS until latter stages of each experimental trial.

In Experiment 1, of the total 929 trials analyzed with a naturally moving stimulus, FEM

showed idiosyncratic differences across subjects. Some subjects exhibited relatively

random FEM directions between each trial (Figure 3.3C, subjects S1 and S2). FEM

trajectories from S3 and S4 showed directionality of motion during the task (Figure 3.3C,

S3 and S4). Absolute trajectory length across subjects was similar. Relative to retinal cone

mosaic, the stimulus traversed a retinal distance equaling about 10.5 unique cones during

each 750-ms presentation during natural viewing. In 600 analyzed trials from the

stabilized condition, residual stimulus motion from tracking and stabilization techniques

was small. On average the stimulus traversed 0.4 cones across all subjects. This analysis

confirms that the exact same set of cones was stimulated during the stabilized as opposed

to natural condition.

Given the nature of the discrimination task, we wondered if the eye can adjust FEM relative

to orientation of the letter optotype to maximize temporal information content, and

whether specific motion traces improve performance on the discrimination task compared

to others. The same motion paths as in Figure 3.3C are plotted in Figure 3.3D, but rotated

relative to optotype orientation during presentation and with indication of correct and

incorrect psychophysical responses. No clear trends were observed in this analysis; the eye

Page 49: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

38

does not seem to adjust FEM behavior according to letter orientation under a short period

of time, and specific motion directions do not appear to confer clear benefits.

Figure 3.3 | Retinal image motion due to FEM and motion manipulation. (A) Projected stimuli are directly encoded into the AOSLO video, allowing for an unambiguous record of the relative locations of the retina and the stimulus over the course of each trial. Here, the path of the stimulus over the course of one trial (duration: 750 msec, colored dots denote stimulus location in each of 23 video frames) of a naturally moving eye is shown. Due to fixational eye motion, the ‘E’ moves over many photoreceptors. (B) When stimuli were presented stabilized, residual stimulus movement was smaller than the diameter of single cones. (C) Retinotopic stimulus trajectories for natural (blue) and stabilized (orange) conditions are shown across subjects S1-S4; subjects exhibit idiosyncratic differences in FEM, sometimes with micro-nystagmus type orientation preferences (e.g. S3). Concentric circles represent 5, 10, and 15 arcmin radii of visual angle around the retinal location of stimulus starting location (compare Fig. 3.1C). (D) Trajectories from the natural condition corresponding with correct (blue) and incorrect (red) psychophysical responses are re-plotted relative to stimulus orientation. There is no clear relation between how the stimulus is sampled and discrimination performance. The size of the letter for each subject is superimposed for reference. Adapted from Ratnam et al., 2017.

3.3.2 Experiment 1: Discrimination benefits from FEM at the resolution limit

Discrimination performance dropped by an average of 23% with retinal image stabilization

(Figure 3.4D; p <0.05, two-tailed binomial z test). Fine spatial resolution was impaired in

the absence of retinal image motion due to FEM. Visual resolution achieved was higher

than predicted by spatial sampling models of the cone mosaic. For each subject, the

distance between adjacent bars of the “E” was compared to the Nyquist limit (Nc) of the

tested retinal location (Figure 3.1E). The stimulus gap constitutes the primary image detail

subjects use to discriminate orientation (Rossi & Roorda, 2010b). The gap size was smaller

than Nc for each subject (gap size/Nc = 0.61/0.90, 0.74/0.85, 0.63/0.80, 0.57/0.94 arcmin

for S1 through S4, respectively).

Page 50: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

39

Subjects performed similarly or better under the incongruent than natural condition

(Figure 3.4E; S1, p < 0.01; S2 and S3, p > 0.05; two-tailed binomial z test, n = ~450). These

findings demonstrate that the visual system can benefit from retinal image motion even

when activity is mismatched with FEM at the time of stimulus presentation.

Figure 3.4 | Stimulus motion improves acuity at the resolution limit. (A) In natural viewing, the stimulus (‘E’) is fixed in space and the retinal cone mosaic (circles) moves due to fixational eye motion (FEM, light blue arrow). (B) In stabilized viewing, the stimulus moves with the retina (orange arrow), such that it stays locked on the same cones during presentation. (C) In the incongruent motion condition, the stimulus moves - while the eye performs its habitual FEM - in a path according to a previously recorded FEM trace. (D) Stimulus stabilization reduced discrimination performance in all subjects by an average of 23%. (E) Relative to the natural viewing condition, subjects performed equally well or better when incongruent motion was employed. Asterisk (*) denotes P-value < 0.05. Adapted from Ratnam et al., 2017.

3.3.3 Experiment 2: Contrast reduction during stabilization is not critical

To quantify whether contrast was reduced by stabilized stimulus delivery and how

performance may have been affected, we devised a pair of experiments. The perceived

contrast of stabilized versus moving stimulus was reduced by about 20%, but performance

was similar (p > 0.05, two-tailed binomial z test, n = ~250) for discrimination of naturally

moving stimuli presented at full and reduced (80%) contrast (Figure 3.5). These results

suggest reduced contrast was not responsible for decreased performance under stabilized

conditions.

Page 51: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

40

Figure 3.5 | Contrast matching and discrimination at reduced contrast. (A) Two squares with identical dimensions to the ‘E’ stimuli in experiment 1 were simultaneously presented retinally stabilized and in an incongruent motion similar to subjects’ own eye movements. Over multiple staircases, the contrast of the moving square was updated until both squares appeared perceptually similar to the subject. These reduced contrast values (percentages indicated in (B)) were used in the second part of the experiment. (B) Discrimination performance for naturally moving, maximum contrast and naturally moving, reduced contrast ‘E’s were compared. Reduced contrast values, indicated as a percentage of maximum contrast, are shown for each subject. Subjects performed similarly for both conditions. Adapted from Ratnam et al., 2017.

3.3.4 Experiment 3: Dynamic cone activation patterns suffice for

discrimination benefit

We tested whether dynamic information presented at the photoreceptor level, effectively a

series of poorly sampled “snapshots”, is sufficient for improving discrimination under the

natural motion condition. Using an external monitor, subjects viewed simulations of cone

activation patterns for moving and stabilized stimuli (Figure 3.6A-B).

Subjects performed on average 27% worse in the static stimulus condition (Figure 3.6C; S1

and S3, p < 0.01; remaining subjects, p < 0.001; two-tailed binomial z test, n = 150). This

degradation is similar to the performance reduction (23%) in Experiment 1; performance

ratios of the natural versus stabilized AOSLO experiment and dynamic versus static

simulation experiment were not significantly different (mean ratio: 1.30 and 1.38,

respectively; p = 0.57; Wilcoxon rank sum test). These results reinforce the fact that the

retinal output via dynamic cone excitation patterns, regardless of ongoing FEM, contains

sufficient information to improve discrimination of images at the sampling resolution limit.

Page 52: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

41

Figure 3.6 | Modelled dynamic cone activation produces a similar benefit to feature discrimination as actual retinal motion. (A) A model of cone activation was derived by convolution of size-matched stimuli with a Voronoi patch of cone photoreceptor positions (see Methods for details). (B) Presented on a standard computer display, stimuli were either computed on a non-moving model mosaic (Static), or on one that moved based on fixational eye movements from the AOSLO experiments (Dynamic). (C) Similar as in natural vs. stabilized viewing, discrimination performance of all subjects dropped when stimuli were presented statically. Asterisk (*) denotes P-value < 0.05. Adapted from Ratnam et al., 2017.

3.4 Discussion

Our results demonstrate that discrimination of high contrast optotypes at the retina’s

resolution limit benefit from image motion similar to or caused by motion due to FEM. The

benefits of eye motion observed in this study are restricted to those caused by ocular drift

Page 53: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

42

and tremor only. Subjects rarely exhibited microsaccades during the stimulus presentation

interval and trials in which microsaccades occurred were removed to eliminate the effects

of microsaccadic suppression on stimulus visibility. Given the current understanding of the

functional consequences of FEM on vision, our findings offer cause to extend such theories.

Theories of spatial whitening postulate that temporal modulations induced by FEM serve

to spectrally equalize the power of natural images across spatial frequencies by de-

correlating low spatial frequencies and enhancing high spatial frequencies. Temporal

modulations induced by typical FEM amplitudes can improve contrast thresholds for

stimuli up to 10 cycles/degree in the presence of lower frequency noise or natural image

statistics (Kuang et al., 2012; Rucci et al., 2007). Additionally, since stabilized stimuli fade

due to neural adaptation (Ditchburn & Ginsborg, 1952; Riggs & Ratliff, 1952; Riggs et al.,

1953), we first needed to explore the extent to which degraded performance under

stabilized image presentation could have been due to reduction in perceptual contrast of

the stimulus. An important aspect of AOSLO stimulus delivery is that stimuli delivered via

the AOSLO scanning raster are continuously modulated at 30 Hz, corresponding to the

system’s frame rate (see Methods). It is known that such temporal modulation is preserved

in visual signals up to postretinal stages, as those 30 Hz signals in neural activity, including

those measured under stabilized stimulus conditions, have been observed in LGN

parvocellular neurons (Sincich et al., 2009). While the raster refresh rate may have

minimized fading, perceptual fading of relatively stable but flickering stimuli is still known

to occur (Schieting & Spillmann, 1987). The minor amount of fading for the stabilized

condition could not explain the performance reduction observed in Experiment 1, and we

generally observed that contrast did not limit discrimination performance (Experiment 2).

Additionally, our visual stimuli were undersampled by the photoreceptor array, a situation

that is not explicitly considered in previous studies.

It is unclear that whitening theories can readily explain the results of our study, and

alternative explanations may be necessary for how FEM enhance acuity. One potential

mechanism can be found in multiframe superresolution algorithms in the field of computer

vision, in which a high-resolution image is reconstructed from a series of lower resolution

frames, enabling the synthesis of images surpassing the spatial resolution of the original

camera (Ben-Ezra, Zomet, & Nayar, 2005; Farsiu, Robinson, Elad, & Milanfar, 2004).

Superresolution techniques include multi-exposure noise reduction and subpixel image

location, in which the centroid of light distribution, blurred due to undersampling, can be

computed with subpixel accuracy. Both mechanisms are feasible within the visual system.

Shifter circuits (Anderson and Van Essen, 1987), interpolation circuits (Barlow, 1979;

Crick, Marr, & Poggio, 1981), neural networks (Pitkow, Sompolinsky, & Meister, 2007), and

neuronal phase locked loops (Ahissar & Arieli, 2012) have all been proposed as

mechanisms by which the signals from a moving retinal image can be correctly integrated.

Page 54: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

43

The visual system is capable of a form of subpixel resolution in a phenomenon known as

hyperacuity (Westheimer, 1987), in which relative stimulus positioning can be judged at a

resolution three to five times higher than the cone sampling limit (Klein & Levi, 1985) and

is robust against retinal image motion (Westheimer & McKee, 1977).

Although FEM are large enough in amplitude to be perceptually visible, our world appears

stable (Murakami, 2003). Conversely, if stimuli are presented with similar amplitudes but

incongruent to actual FEM, they are perceived as moving (Arathorn et al., 2013). In order to

correct for ocular jitter and provide a stable percept of the external world, it has been

suggested that the visual system decodes retinal signals relative to FEM (Burak, Rokni,

Meister, & Sompolinsky, 2010; Coakley, 1983; Eizenman, Hallett, & Frecker, 1985). If cone

signals are integrated relative to ongoing FEM, then the benefits of FEM may be limited to

image motion caused by natural eye movements. In Experiment 1, we created an

incongruent viewing condition in which the stimulus moved in trajectories derived from

subjects’ earlier eye movements. Discrimination performance was similar under natural

and incongruent motion conditions, so efference-based processes are unlikely to contribute

to the integration of dynamic cone signals from the incongruent condition. Efference

copies, which are generated at central motor stations, are not expected to have sufficient

resolution for resolving spatial ambiguities of details (<1 arcmin) presented in the current

study (Havermann, Cherici, Rucci, & Lappe, 2014). Even if their resolution was sufficient,

their involvement would not explain why similar performance was achieved in the natural

and incongruent conditions. Afferent based mechanisms for encoding retinal image motion,

such as proposed models of elongated arrays of retinal ganglion cells (Ahissar, Ozana, &

Arieli, 2015) would better explain performance in the incongruent viewing condition.

Our results, demonstrating benefits from eye motion at the visual acuity limits, may have

practical implications. It may explain how patients with retinal degenerative diseases

maintain excellent visual acuity despite massive reductions in foveal cone density (Chapter

2) or how the increased FEM in patients with central vision loss could be a mechanism to

optimize the benefits of image motion for larger receptive fields outside the fovea (Hennig

& Worgotter, 2004). Cone activations during FEM may also serve as a biomimetic principle

for the refinement of image processing algorithms in computer vision and the design of

retinal prosthetics (Dagnelie, 2012). It can also help explain why performance improves

with duration on a visual acuity task (Baron & Westheimer, 1973).

3.6 Follow-up neural model of high-acuity vision in the presence of

fixational eye movements

In an attempt to better understand the neural circuitry that may give rise to the present

study’s psychophysical results, Alexander et al. proposed a computational model based on

a Bayesian ideal observer that approximates the retinal image given simulated retinal

Page 55: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

44

ganglion cell (RGC) spikes (Anderson, Ratnam, Roorda, & Olshausen, 2016). Eye motion

traces, cone spacing measurements, and stimulus size from the AOSLO experiments were

integrated into the model, in which RGC spikes were simulated as if a diffraction-limited ‘E’

were presented to the retina. RGC spike patterns were used to perform a maximum

likelihood estimate of eye motion and the inferred retinal image, the latter of which had a

stronger signal to noise ratio with the presence of retinal image motion. These simulations

corroborate our psychophysical findings to suggest neural circuitry improve acuity in the

presence of retinal image motion.

3.7 Acknowledgements

The efforts described in this chapter, with the exception of section 3.6, were published as a

manuscript in Journal of Vision in January 2017 with the invaluable assistance of co-authors

Niklas Domdei, Dr. Wolf Harmening, and Dr. Austin Roorda. The author performed all of the

AOSLO experiments and did all of the analysis on eye motion and acuity performance.

Section 3.6 is primarily the work of Alexander Anderson of the Redwood Center for

Theoretical Neuroscience, under the tutelage of Bruno Olshausen and Austin Roorda. The

author of the dissertation implemented the psychophysical experiments that the

computational models were based on.

Page 56: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

45

Chapter 4

The stability of fixation during high-spatial

vision

Page 57: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

46

Chapter 4

The stability of fixation during high-spatial vision

4.1 Abstract

Since our eyes are never at rest, the act of “fixation,” or gazing at a specific object, does not

utilize a fixed location in the fovea but actually employs a small foveolar subregion whose

relative location and expanse is variable across individuals. Since cone density and hence

the maximum sampling limit of the photoreceptor mosaic drops rapidly even within the

fovea, it may seem sub-optimal that fixation is not necessarily restricted to the foveal

region with the theoretical maximum sampling resolution. However, due to the

imperfections of the typical eye, natural acuity is limited by the eye’s optics rather than

sampling density of the foveal cone mosaic, thus effectively homogenizing acuity within the

fovea and making optimal fixational behaviors unnecessary. It is hence unknown how

fixational patterns may differ when acuity is limited by the cone photoreceptor sampling

limit. We used an adaptive optics scanning laser ophthalmoscope to compensate for ocular

blur and deliver near-diffraction limited stimuli to the retina, enabling us to quantify the

foveal region used for fixation, or the preferred retinal locus (PRL), measure acuity within

foveal subregions, and determine the role of fixational eye movements in relocating stimuli

presented within discrete foveal locations to a preferred fixational locus.

4.2 Introduction

Even when fixating on a static object, our eyes are constantly moving. As a result, our

preferred retinal locus of fixation (PRL) spans a region rather than fixed point within the

fovea (Steinman, 1965), whose center does not necessarily correspond to the location of

maximum cone density (Li et al., 2010; Putnam et al., 2005; Wilk et al., 2017). Although it

may seem suboptimal for the visual system to utilize a fixation locus deviant from the

location of peak cone density, blurring due to the eye’s imperfect optics reduces visual

acuity below the cone Nyquist limit (Marcos & Navarro, 1997), minimizing the need to use

this theoretically optimal location for everyday vision. Early work reported that the

location of maximum acuity was not displaced from fixation (Weymouth et al., 1928), but

these results reflect acuity blurred by the eye’s optics and not that limited by the true cone

sampling limit.

With the advent of adaptive optics techniques for retinal imaging, it has become possible to

compensate for ocular blur, obtain high-resolution images of foveal cones, and deliver

near-diffraction-limited stimuli to the retina, allowing a more direct comparison between

fixation behavior and the location of peak cone density. Putnam et al. used an adaptive

optics (AO) ophthalmoscope to present subjects with a 1° maltese cross and quantified the

Page 58: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

47

spread of the PRL in relation to the location of maximum cone density (Putnam et al.,

2005). They found the mean standard deviation of fixation to be 3.4 arcminutes of visual

angle, consistent with previous reports (Barlow, 1952; Ditchburn, 1973; Steinman et al.,

1973). The center of fixation was found to be approximately 8-11 arcmin from the location

of peak cone density. Li et al., using an AO scanning laser ophthalmoscope, found the PRL to

be displaced from peak cone density by approximately 5 arcmin (Li et al., 2010). Since cone

density, and presumably acuity, drops off rapidly from the peak location (Curcio et al.,

1990), subjects’ fixational behaviors did not appear to utilize the optimal location for

maximum acuity, even when the confounding effects of ocular blur were minimized.

A potential conjecture for this finding is that traditional fixation stimuli, such as a maltese

cross or solid square, lack high-frequency features that necessitate use of the region of

maximum acuity. Additionally, subjects participated in a passive fixation task rather than

actively discriminating a feature of the fixation target, a subtle difference in instructions

that could potentially change fixational behavior. Most critically, visual acuity within

subregions of the foveal center (~0.5 degrees in diameter) has not been systematically

measured before while compensating for ocular blur. It is therefore unknown whether or

how quickly acuity drops off within this region and whether current fixational patterns are

sub-optimal, especially when viewing a high-frequency stimulus.

By using adaptive optics to compensate for ocular blur and deliver near-diffraction-limited

retinal stimuli, the purpose of the current study was to systematically map acuity within

the central 0.5° of the fovea, enabling a more direct comparison between fixational spread,

the location of peak cone density, and sub-foveal differences in acuity. An additional

objective of this study was to assess the potential role of eye movements in optimizing

fixational behavior when discriminating stimuli at the limits of spatial vision. The role of

FEM, and in particular microsaccades, in high-spatial tasks has long been debated, with

multiple studies (including Chapter 3 of this document; see Figure 3.2) showing that

microsaccades are suppressed during high-acuity tasks (Bridgeman & Palca, 1980;

Winterson & Collewijn, 1976). Conflicting work, however, has shown that microsaccades

tend to be more frequent and smaller during strict rather than relaxed fixation (Cherici,

Kuang, Poletti, & Rucci, 2012) and less frequent when stimuli are presented stabilized

rather than unstabilized at the PRL (Poletti & Rucci, 2010), all suggesting that

microsaccades serve to relocate stimuli within the fovea. In particular, microsaccades have

been shown to precisely relocate gaze within the foveola during high-acuity tasks such as

the threading of a needle (Ko, Poletti, & Rucci, 2010) and discrimination of high frequency

gratings shown at specific intervals within the central fovea (Poletti, Listorti, & Rucci,

2013). Although these studies showed the utility of microsaccades in relocating stimuli

within the fovea, they were unable to determine how this function potentially reflected

differing visual function at discrete locations within the central fovea.

Page 59: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

48

In the current study, we presented high-frequency stimuli at discrete intervals within the

fovea to determine whether microsaccades relocate stimuli to a specific retinal location,

and determined how the specificity of relocation related to visual acuity at specific regions

within the fovea. Since subjects were instructed to gaze directly at the stimulus during this

relocation task, we were also able to quantify the fixational “dead zone”, or the distance

from the fixational center at which eye motion statistics changed to relocate stimuli closer

to the fixational center. The results of this study support the theory that microsaccades

serve to precisely relocate stimuli within the central fovea.

4.2 Methods

4.2.1 Subjects

Subjects were six adults (three males, three females; ages 25-29 years), who had no known

visual issues and were naïve to the purpose of the study. A drop of 1% Tropicamide

solution was instilled in the test eye, chosen as the eye with less refractive error, 15

minutes prior to testing for pupil dilation and cycloplegia. Informed consent was obtained

for each subject and experimental procedures adhered to the tenets of the Declaration of

Helsinki.

4.2.2 AOSLO imaging and stimulation

Adaptive optics imaging and micro-stimulation were used to present retina-contingent

visual stimuli to targeted locations in cone-resolved retinae of human observers, a method

described in detail elsewhere (Arathorn et al., 2007; Rossi & Roorda, 2010b). The light

source was a supercontinuum laser (SuperK Extreme; NKT Photonics) with an infrared

imaging wavelength of 842 ± 25 nm (luminance of ~ 4 cd/m2). Retinal images were derived

by recording the light scattered from a focused spot, raster-scanning across the retina with

horizontal and vertical scan rates of 16 kHz and 30 Hz respectively. High order aberrations

were measured with a Shack-Hartmann wavefront sensor, and a 97-actuator, 25-micron

stroke deformable mirror (ALPAO) corrected the computed wavefront error. Corrected

light was captured with a photomultiplier tube, whose voltage output combined with

positional signals from scanning mirrors created 512 x 512 pixel videos with a framerate of

30 Hz. For Session 1, a 1-second retinal video was recorded with every stimulus

presentation trial; a 2-second video was recorded per trial during Session 2.

Stimuli were encoded into the scanning raster via 20 MHz acousto-optic modulation that

switched off the laser beam at points in the raster corresponding to the stimulus location,

producing stimulus decrements with high contrast (dark ‘E’ on a red background).

Michelson contrast between full-on and full-off stimulation was 99.9%. Diffraction reduced

the actual “E” contrast to between 60%-75%. 1.3° and 1.4° raster fields were used for

Page 60: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

49

Sessions 1 and 2 respectively, resulting in sampling resolutions for imaging and stimulus

projection of ~0.15-0.16 arcmin per pixel.

During both experimental sessions, subjects’ heads were immobilized using customized

bite bars. At the beginning of every experimental session, defocus induced by the

deformable mirror was optimized for foveal imaging and stimulus delivery. First, an

estimate of ideal defocus was derived from wavefront sensor measurements. Videos at

0.025 D defocus intervals away from the estimated value were acquired and analyzed. The

defocus value with the sharpest images of foveal cones was then used as the baseline level

for the remainder of the session.

4.2.3 Session 1: Mapping acuity within the central fovea

During Session 1, we mapped visual acuity at 5-arcmin intervals from the center of fixation.

First, the spread of the PRL was quantified by asking subjects to fixate on a flashing dot

(diameter = 5 arcmin) for 10 seconds. The retinal location of the fixation dot in each video

frame was extracted using custom MATLAB scripts, which was then used to quantify the

mean location (hereby referred to as ‘fixation center’) and spread of fixation (standard

deviation, SD) for that session. The fixation center (PRL1) served as the central coordinates

(0’) from which acuity measurements were taken. In addition to at the fixation center,

acuity was measured 5 and 10 arcmin in either direction along the horizontal and vertical

meridians (Figure 4.1) for a total of 9 test locations. Acuity thresholds were measured

using the QUEST protocol, an adaptive psychometric procedure in which the stimulus size

for each trial is the current most probable Bayesian estimate of the threshold (Watson &

Pelli, 1983). QUEST is generally a more efficient threshold-determining procedure than

method of constant stimuli or other staircase techniques, minimizing the number of trials

necessary to estimate threshold. During each trial, the ‘E’ was presented retinally stabilized

in one of four directions for 750 msec, after which subjects indicated the perceived

orientation. Trials were self-initiated by the subject. For each tested location, 40 trials were

used to determine threshold, set to be the stimulus size at which subjects correctly

discriminated the ‘E’ 72% of the time. Trials for all locations were pseudo-randomly

interleaved, split into 80-trial blocks and repeated to get two threshold measurements per

location, for a total of 720 trials.

Page 61: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

50

Figure 4.1 | Stimulus delivery locations during Sessions 1 and 2. The fixation center, noted here as the origin (0’), was derived separately for Sessions 1 and 2. Acuity measurements were made during Session 1 at 0, 5, and 10 arcmin intervals along the horizontal and vertical meridians. Two threshold measurements were acquired per test location. During Session 2, the stimulus was delivered to locations 0 to 15 arcminutes away from fixation along the horizontal meridian only.

4.2.4 Session 2: Stimulus refoveation within the central fovea

During Session 2, we repeated the protocol to determine the mean location and spread of

fixation (PRL2), which was then used as the central coordinates from which stimuli were

presented for the remainder of the session. In this session we were interested in potential

differences in fixation characteristics depending on where stimuli were initially presented

relative to the fixation center. During each trial, the ‘E’ optotype was presented for 1 second

at locations 0, 5, 10, or 15 arcmin away from the fixation center along the horizontal

meridian (Figure 4.1). Stimulus size was fixed to be the smallest ‘E’ threshold from Session

1, or in other words the stimulus threshold from the location with potentially maximum

acuity. Subjects were instructed to indicate the orientation of the ‘E’ for a given trial, and

more crucially, told that they were free to gaze directly at the stimulus during this session.

This clarification was important since in the first session, during which stimuli were

stabilized to specific locations eccentric from the PRL, subjects were told to avoid trying to

directly gaze at the stimulus if it was presented eccentrically. In the current session, the ‘E’

was initially presented to a tracked retinal location but then untracked so the stimulus

could move on the retina according to subjects’ eye movements. This condition, with initial

retinal tracking followed by unstabilized stimulus presentation, is referred to as ‘gain

clamping’. A total of 500 trials were collected, each condition pseudorandomly interleaved.

The stimulus was presented for 1 second, rather than 750 msec, during Session 2 to

account for potential delays in the onset of eye movement changes in response to stimulus

presentation. Increasing stimulus duration allowed sufficient eye movement data to be

Page 62: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

51

collected for analysis. Since longer stimulus exposure duration can affect acuity thresholds

due to an increase light summation or signal integration, this difference in duration across

Sessions 1 and 2 could have introduced inconsistencies in visual performance. Earlier work

however suggests that acuity performance plateaus at 400-500 msec stimulus durations

(Baron & Westheimer, 1973), suggesting that acuity was already maximized with the 750-

msec presentation and should have been consistent across sessions.

4.2.5 Measurement of location of peak cone density

Cones were manually selected within the central 1.3 degrees of the AOSLO foveal images

for each subject. Cone coordinates were then fed into a custom MATLAB script in which a

moving sampling window was convolved with the cone locations to determine density

across the foveal region. The peak cone density location was then determined and

compared to the relative location of the PRL from both experiment sessions.

4.2.6 Eye movement analysis and trial rejection

Fixational eye movements that occurred during stimulus delivery in Session 2 were

analyzed offline from recorded AOSLO videos with a sampling rate of 840 Hz (Stevenson,

Roorda, & Kumar, 2010). Epochs of microsaccades and drift were segregated and analyzed

separately.

Proper stimulus delivery was verified by looking for distorted or otherwise incorrectly

delivered stimuli in the AOSLO videos. Trials with misdelivered stimuli were removed from

further analysis.

4.3 Results

4.3.1 Stability of PRL across sessions and distance from location of peak cone

density

Subjects in the current study, in which the two sessions were separated by an average of 7

days, showed very stable fixation behaviors, with displacement across sessions ranging

from 0.2 to 4.1 arcmin (mean, 1.2 arcmin; Table 4.1). The distance of the fixation center to

location of peak cone density ranged from 1.7 to 7.2 arcmin (mean, 3.8 arcmin). Figure 4.2

shows contour maps depicting the PRL spread for both sessions overlayed on AOSLO foveal

images, with the location of peak cone density marked in red.

Page 63: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

52

PRL1 PRL2

Subject

SDx SDy

Distance to peak

cone density

SDx SDy

Distance to peak

cone density

Mean distance PRL1 to

PRL2 S1 1.5 1.8 6.1 2.1 1.7 6.0 0.2 S2 1.8 1.6 1.9 1.9 2.1 1.8 0.2 S3 0.9 2.5 4.5 2.4 2.4 4.7 1.8 S4 6.3 2.4 7.2 3.3 2.1 3.3 4.1 S5 4.1 2.4 2.6 4.0 2.9 2.6 0.2 S6 5.4 1.8 1.7 3.1 1.4 2.6 0.9

Mean 3.3 2.1 4.0 2.8 2.1 3.5 1.2

Table 4.1 | PRL characteristics across sessions. Fixation patterns of subjects across experiment sessions (Session 1, PRL1; Session 2, PRL2). Values are in arcminutes.

Figure 4.2 | PRL topography and location relative to peak cone density. Fixation patterns of subjects across experiment sessions (Session 1, PRL1 (solid contours); Session 2, PRL2 (dashed

contours)) overlayed on 0.5° x 0.5° AOSLO images. Dark blue, light blue, green, and yellow contours encapsulate regions containing 25, 50, 75, and 100% of the retinal regions used for fixation,

Page 64: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

53

respectively. Session 2 images contain a subtle gray outline of the outermost contour from PRL1 as a reference. Red diamond indicates location of peak cone density. Scale bar = 5 arcmin.

4.3.2 Session 1 results: Acuity within the central fovea

Two acuity thresholds were measured at each of 9 retinal locations using the QUEST

protocol. The mean values of these thresholds are shown in Figure 4.3. The standard

deviation (SD) of each threshold distribution was ±0.18 arcmin. Threshold values across all

stimulus locations were within 1 SD of each other, suggesting that acuity as measured in

the current study was relatively homogeneous within a 10-arcmin radius from the center of

fixation, as measured during Session 1.

Figure 4.3 | Acuity measurements within central fovea. The mean of two QUEST-acuity thresholds measured at retinal locations 0, 5, and 10 arcmin away from the fixation center in Session 1. Values are in units of arcmin. Central square corresponds to foveal center with adjacent squares being 5 arcmin intervals away (see Figure 4.1 for reference diagram). SD of measurements are ±0.18 arcmin.

4.3.3 Session 2 results: Fixational eye movements by initial stimulus location

Fixational eye movement data was binned by initial stimulus location and analyzed for

epochs of microsaccades and drift. For trials in which microsaccades occurred, the

orientation (θ) and amplitude (ρ) of the initial microsaccade following stimulus

presentation were analyzed and plotted in Figure 4.4. It is visually apparent that subjects

S1, S2, and S6 had more trials with microsaccades than S3, S4, and S5, noticeable by the

Page 65: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

54

density of data points in the polar plots. It is also visually apparent that the orientation and

amplitude of the initial microsaccade shifted depending on initial stimulus location, seen as

a rightward shift of the scatterplot distribution for a given subject as stimulus location goes

from -15 to 15 arcmin (Figure 4.4). Table 4.2 quantifies and summarizes the data shown in

Figure 4.4.

Page 66: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

55

Figure 4.4 | First microsaccade orientation and amplitude relative to stimulus start position. Polar scatter plots depicting orientation and amplitude of the first microsaccade per trial for given initial stimulus positions (-15 to 15 arcmin along horizontal meridian). Subjects S1, S2, and S6 appear to have a bias in microsaccade characteristics given the stimulus start point, visualized as a rightward shift of the scatterplot distribution as the stimulus location goes from -15 to 15 arcmin. Colored points are individual data points; black points are mean values. Rho values for polar plots are in arcmin; angle values are in degrees.

Page 67: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

56

In addition to looking at spatial characteristics of initial microsaccades per trial, we plotted

microsaccade frequencies as a function of stimulus start location in Figure 4.5. Subjects S1,

S2, S5, and S6 exhibited fewer microsaccades per trial when the initial stimulus location

was closer to the fixation center. This trend is most visible in S1 and S6. Subjects S3 and S4

rarely made microsaccades, irrespective of stimulus start point, with microsaccades

occurring in ~20% of their trials.

Since subjects S3 and S4 mainly made drift eye movements, we analyzed the orientation of

drift by stimulus start point to see whether the drift trajectory was biased to move fixation

in the direction of the stimulus. Drift trajectories generally exhibit the properties of a self-

avoiding random walk, or a stochastic process that consists of random steps that avoid

reverting to the location of the previous step (Engbert, Mergenthaler, Sinn, & Pikovsky,

2011). Each step of a random walk for a single drift epoch would therefore have

approximately equal probability of moving across all orientations, which would manifest in

a histogram with equal distribution of steps across all orientations. We plotted the

orientations of all drift steps, binned by stimulus start position, in Figure 4.6, for subjects

S3 and S4. Although drift showed slight orientation bias in both subjects, this bias was

relatively consistent across and independent of stimulus start position, suggesting that

subjects S3 and S4 did not utilize drift to reorient eccentric stimuli closer to the fixation

center.

Next we looked at drift characteristics across all subjects to see whether the orientation of

drift, including during inter-saccadic epochs, would shift depending on the relative location

of the stimulus at that time. We analyzed all drift segments from each subject and binned

each step orientation depending on whether the stimulus location was currently to the left

or right of fixation. This allowed us to assess whether drift served to compensate for

saccadic under- or overshoots relative to stimulus position, as well as to observe whether

drift could generally be modulated to relocate gaze. Figure 4.7 shows drift characteristics

for a given subject were remarkably consistent regardless of stimulus direction and that all

subjects exhibited idiosyncrasies in drift orientation. Our finding is consistent with those of

Poletti et al., who similarly showed that drifts did not serve to reorient gaze towards

stimuli (Poletti et al., 2013). Additionally, idiosyncratic differences in fixational eye

movements such as those exhibited by our subjects are widely cited in the literature,

although these traits have not been systematically characterized.

Page 68: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

57

Figure 4.5 | Microsaccade frequency by initial stimulus location. Stacked histograms showing

microsaccade frequencies per trial as a function of initial stimulus position. Subjects S1, S2, S5, and

S6 appeared to make fewer microsaccades when the initial stimulus location was closer to the

fixation center (0), with S1 and S6 most strongly showing this trend. Subjects S3 and S4 rarely made

microsaccades during all trials, regardless of stimulus start position. Microsaccade frequencies,

shown in figure legends, are in Hz.

Page 69: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

58

Page 70: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

59

Figure 4.6 | Polar histograms of drift step orientation for Subjects S3 and S4. Normalized polar

histograms showing directionality of each drift step binned by stimulus location for subjects S3 and

S4. A random walk would exhibit approximately uniform probability of directionality across all

orientations. Subject S3 exhibited a subtle bias in drift directionality towards the lower left

quadrant while S4 showed a tendency to drift towards the upper right. These biases were relatively

consistent across stimulus start positions however and would not have reoriented fixation towards

the stimulus, suggesting that drift was not utilized to systematically reorient gaze in these subjects.

Page 71: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

60

Page 72: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

61

Figure 4.7| Drift step orientation relative to location of stimulus. Normalized polar histograms

showing directionality of each drift step binned by relative location of stimulus(to the left or right of

fixation). Subjects showed consistent idiosyncratic drift orientation patterns independent of

stimulus direction, suggesting that drift, even during inter-saccadic epochs, was not utilized to

reorient gaze towards the stimulus.

Since the initial stimulus locations in Session 2 were displaced along the horizontal

meridian, we performed a more thorough analysis of microsaccade amplitude along the

horizontal axis only, done by decomposing the amplitude vector into its horizontal and

vertical projections. Figure 4.8 shows boxplots depicting the distribution of the horizontal

amplitude data. An analysis of variance (ANOVA) and Tukey-Kramer test were performed

on the horizontal amplitude data to look for differences in mean microsaccade amplitudes

based on initial stimulus location. Coupled with ANOVA, the Tukey-Kramer test is a

multiple-comparisons test used to compare all possible pairs of means for significant

differences (Tukey, 1949). The Tukey-Kramer method is conservative when there are

unequal sample sizes per group, a necessity with the current dataset in which

microsaccade occurrences were variable across subjects. Table 4.4 summarizes the results

from the Tukey-Kramer analyses and a visualization of the significance of difference-of-

means is shown in Figure 4.9.

The probability distribution over the course of stimulus presentation for initial

microsaccades is shown in Supplementary Figure S4.1. The mean onset time for all subjects

was 400 msec and 315 msec if S3 and S4 are excluded.

Page 73: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

62

Figure 4.8 | Boxplots of horizontal microsaccade amplitude data. Box plots showing

distribution of horizontal microsaccade amplitude data by stimulus start location. Red line indicates

median value; top and bottom line of box indicate 75th and 25th-percentile values respectively.

Height of box indicates interquartile range. Horizontal markers connected to box by dashed lines

indicate highest and lowest data values within 1.5*25th or 75th-percentile value respectively.

Outliers are indicated as red crosses. Microsaccade amplitudes are in units of arcmin.

Page 74: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

63

Figure 4.9 | Visualization of results from Tukey-Kramer analysis. The Tukey-Kramer method, a

post-hoc analysis for doing multiple comparisons of difference of means, was used to compare

mean horizontal amplitudes of microsaccades between stimulus start points. The red regions in

each matrix shows group pairs in which the means were significantly different (P < 0.05).

Quantitative values are available in Table 4.4.

Page 75: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

64

S1 S2 S3 S4 S5 S6

Stim. Loc.

Mean θ; ρ

Mean X; Mean Y (± SEM)

Mean θ; ρ

Mean X; Mean Y (± SEM)

Mean θ; ρ

Mean X; Mean Y (± SEM)

Mean θ; ρ

Mean X; Mean Y (± SEM)

Mean θ; ρ

Mean X; Mean Y (± SEM)

Mean θ; ρ

Mean X; Mean Y (± SEM)

-15 185.2; 14.9

-14.8 (± 0.5) 158.4;

9.8

-9.1 (± 0.7) 170.3;

6.7

-6.6 (± 4.8) 210.5;

16.0

-13.8 (± 6.5) 190.9;

7.8

-7.7 (± 4.3) 178.8;

9.0

-9.0 (± 2.5)

-1.4 (± 0.2)

3.6 (± 0.6)

1.1 (± 1.4)

-8.1 (± 3.3)

-1.5 (± 2.1)

0.2 (± 1.0)

-10 184.7; 12.2

-12.1 (± 0.2) 124.0;

5.8

-3.2 (± 0.9) 69.9;

5.4

1.9 (± 3.3) 349.8;

14.0

13.8 (± 11.2) 327.0;

2.2

1.8 (± 6.1) 167.7;

7.8

-7.6 (± 1.9)

-1.0 (± 0.3)

4.8 (± 0.8)

5.1 (± 1.2)

-2.5 (± 4.3)

-1.2 (± 1.5)

1.7 (± 0.9)

-5 208.5;

8.7

-7.6 (± 1.1) 114.7;

4.0

-1.7 (± 0.9) 67.0;

7.7

3.0 (± 3.0) 205.3;

22.4

-20.3 (± 0.0) 135.2;

1.0

-0.7 (± 7.9) 147.2;

2.5

-2.1 (± 2.6)

-4.1 (± 0.4)

3.6 (± 1.0)

7.1 (± 1.6)

-9.6 (± 0.0)

0.7 (± 2.4)

1.3 (± 1.3)

0 254.2;

6.3

-1.7 (± 0.9) 39.2;

4.4

3.4 (± 0.8) 74.9;

5.2

1.3 (± 2.6) 189.5;

12.5

-12.4 (± 4.4) 17.2;

8.0

7.6 (± 1.7) 358.4;

2.2

2.2 (± 2.6)

-6.1 (± 0.4)

2.8 (± 0.8)

5.0 (± 1.4)

-2.1 (± 4.6)

2.4 (± 1.2)

-0.1 (± 1.5)

5 315.8;

6.4

4.6 (± 1.4) 33.2;

6.3

5.3 (± 0.9) 12.3;

4.2

4.1 (± 3.6) 206.9;

20.4

-18.2 (± 5.0) 4.2;

7.9

7.8 (± 5.4) 9.5;

5.8

5.7 (± 2.4)

-4.5 (± 0.5)

3.4 (± 1.0)

0.9 (± 0.7)

-9.2 (± 3.0)

0.6 (± 1.8)

1.0 (± 1.5)

10 345.8;

9.6

9.3 (± 1.1) 23.6;

9.3

8.5 (± 1.0) 74.7;

6.9

1.8 (± 5.8) 243.7;

11.8

-5.2 (± 7.0) 358.7;

20.8

20.8 (± 2.4) 1.8;

10.5

10.5 (± 1.8)

-2.4 (± 0.2)

3.7 (± 0.8)

6.7 (± 2.6)

-10.6 (± 2.8)

-0.5 (± 1.6)

0.3 (± 0.8)

15 353.7; 13.3

13.3 (± 0.4) 17.3;

10.0

9.5 (± 1.1) 62.5;

5.1

2.4 (± 3.9) 226.4;

32.8

-22.7 (± 0.0) 359.4;

19.4

19.4 (± 5.7) 2.8;

14.1

14.1 (± 2.2)

-1.5 (± 0.2)

3.0 (± 0.9)

4.6 (± 0.9)

-23.8 (± 0.0)

-0.2 (± 1.5)

0.7 (± 1.1)

Page 76: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

65

Table 4.2 | First microsaccade orientation and amplitude relative to stimulus start position. Summary of microsaccade characteristics depicted in Figure 4.4. Subjects S1, S2, and S6 in general had more trials with microsaccades per stimulus location than S3, S4, and S5. The mean microsaccade orientation (θ) and amplitude (ρ) for S1, S2, and S6 systematically shifted with stimulus location. A statistical analysis of this data is presented in Table 4.4. Units of orientation (θ) and amplitude (ρ) are in degrees and arcmin, respectively.

S1 S2 S3 S4 S5 S6

N (All Locations) 330 297 65 26 76 184 Mean Stimulus

Displacement from Fixation (X; Y)

1.3; 3.0 -1.8; -3.6 -1.1; -4.3 11.2; 9.4 -7.0; 0.0 -2.0; -0.7

Mean Stimulus Displacement from Peak Cone Density

Location (X; Y [Absolute])

4.0; -0.1 [4.0]

3.5; 2.8 [4.5]

2.1; 8.9 [9.2]

-7.9; -9.2 [12.1]

6.0; -2.4 [6.5]

4.0; -2.4 [4.6]

Table 4.3 | Stimulus location relative to fixation center and location of peak cone density after initial microsaccade, averaged over all locations. Mean horizontal and vertical displacements of stimulus relative to fixation center and location of peak cone density following initial microsaccade. Values are averaged over all trials and stimulus locations. Positive values indicate stimulus is to the right (X) or above (Y) fixation center or peak cone density location; negative values indicate locations to the left (X) or below (Y). Units are in arcminutes.

Table 4.4 | Tukey-Kramer analysis of microsaccade amplitudes (horizontal only). The Tukey-Kramer method is a post-hoc analysis for determining the significance of differences between multiple means. Each row corresponds to a comparison of means from two groups, differentiated by the stimulus start location. The difference of means and confidence intervals (CI) have units of arcmin. Comparisons with a significant difference in means (P-value < 0.05) are shaded in red. A visual depiction of these regions of significance are shown in Figure 4.9.

Page 77: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

66

S1 S2 S3 S4 S5 S6

Group 1

Group 2

Difference of means [CI]

P-value

Difference of means [CI]

P-value

Difference of means [CI]

P-value

Difference of means [CI]

P-value

Difference of means [CI]

P-value Difference of means [CI]

P-value

-15 -10 -2.7

[-6.4, -2.7] 0.32

-5.9 [-9.8, -1.9]

< 0.001

-8.5 [-24.3, 7.3]

0.66 -27.6

[-60.4, 5.2] 0.13

-9.5 [-30.1, 11.1]

0.80 -1.4

[-10.6, 7.8] 1

-15 -5 -7.2

[-10.9, -3.5] <

0.001 -7.4

[-11.6, -3.2] <

0.001 -9.7

[-28.9, 9.6] 0.72

6.4 [-48.4, 61.3]

1 -7.0

[-34.5, 20.5] 0.99

-6.9 [-16.9, 3.1]

0.40

-15 0 -13.1

[-16.6, -9.6] <

0.001 -12.5

[-16.1, -8.9] <

0.001 -8.0

[-23.7, 7.7] 0.71

-1.5 [-37.4, 34.5]

1 -15.3

[-32.9, 2.3] 0.13

-11.2 [-20.1, -2.2]

0.004

-15 5 -19.4

[-23.4, -15.5] <

0.001 -14.4

[-18.3, -10.4] <

0.001 -10.8

[-28.7, 7.1] 0.53

4.3 [-23.9, 32.6]

1 -15.5

[-35.6, 4.6] 0.24

-14.7 [-24.5, -4.8]

< 0.001

-15 10 -24.1

[-27.8, -20.4] <

0.001 -17.6

[-21.7, -13.5] <

0.001 -8.5

[-28.7, 11.8] 0.86

-8.6 [-41.4, 24.2]

0.97 -28.5

[-46.1, -10.8] < 0.001

-19.4 [-28.0, -10.9]

< 0.001

-15 15 -28.1

[-31.6, -24.6] <

0.001 -18.6

[-22.5, -14.7] <

0.001 -9.0

[-26.9, 8.9] 0.72

8.8 [-46.0, 63.7]

1 -27.1

[-46.3, -7.8] 0.001

-23.0 [-32.2, -13.9]

< 0.001

-10 -5 -4.5

[-8.0, -0.9] 0.004

-1.6 [-5.6, 2.5]

0.92 -1.2

[-17.9, 15.5] 1

34.1 [-22.7, 90.9]

0.46 2.5

[-24.5, 29.5] 1

-5.5 [-16.1, 5.1]

0.72

-10 0 -10.4

[-13.7, -7.0] <

0.001 -6.6

[-10.1, -3.1] <

0.001 0.5

[-11.9, 12.9] 1

26.2 [-12.6, 65.0]

0.33 -5.8

[-22.6, 11.0] 0.94

-9.8 [-19.4, -0.2]

0.04

-10 5 -16.7

[-20.6, -12.9] <

0.001 -8.5

[-12.3, -4.6] <

0.001 -2.3

[-17.4, 12.9] 1

32.0 0.1, 63.8]

0.05 -6.0

[-25.4, 13.4] 0.96

-13.3 [-23.7, -2.9]

0.003

-10 10 -21.4

[-25.0, -17.8] <

0.001 -11.7

[-15.7, -7.7] <

0.001 0.0

[-17.8, 17.9] 1

19.0 [-16.9, 55.0]

0.60 -19.0

[-35.8, -2.2] 0.02

-18.1 [-27.3, -8.8]

< 0.001

-10 15 -25.4

[-28.8, -22.0] <

0.001 -12.8

[-16.6, -9.0] <

0.001 -0.5

[-15.6, 14.6] 1

36.5 [-20.3, 93.3]

0.39 -17.6

[-36.1, 1.0] 0.07

-21.7 [-31.4, -11.9]

< 0.001

-5 0 -5.9

[-9.2, -2.6] <

0.001 -5.1

[-8.9, -1.3] 0.002

1.7 [-14.9, 18.2]

1 -7.9

[-66.6, 50.8] 1

-8.3 [-33.1, 16.5]

0.95 -4.3

[-14.6, 6.0] 0.89

-5 5 -12.3

[-16.1, -8.4] <

0.001 -6.9

[-11.0, -2.8] <

0.001 -1.1

[-19.8, 17.6] 1

-2.1 [-56.4, 52.2]

1 -8.5

[-35.1, 18.1] 0.96

-7.8 [-18.9, 3.3]

0.37

-5 10 -16.9

[-20.5, -13.4] <

0.001 -10.2

[-14.4, -6.0] <

0.001 1.2

[-19.7, 22.1] 1

-15.0 [-71.8, 41.8]

0.97 -21.5

[-46.3, 3.3] 0.13

-12.5 [-22.6, -2.5]

0.004

-5 15 -20.9

[-24.3, -17.5] <

0.001 -11.2

[-15.3, -7.2] <

0.001 0.6

[-18.0, 19.3] 1

2.4 [-69.5, 74.3]

1 -20.1

[-46.1, 5.9] 0.24

-16.2 [-26.6, -5.7]

< 0.001

0 5 -6.3

[-10.0, -2.7] <

0.001 -1.9

[-5.4, 1.7] 0.71

-2.8 [-17.8, 12.2]

1 5.8

[-29.3, 40.9] 1

-0.2 [-16.3, 15.9]

1 -3.5

[-13.7, 6.7] 0.95

0 10 -11.0

[-14.4, -7.6] <

0.001 -5.1

[-8.8, -1.4] <

0.001 -0.5

[-18.2, 17.2] 1

-7.1 [-45.9, 31.7]

1 -13.2

[-26.1, -0.2] 0.04

-8.3 [-17.2, 0.7]

0.09

0 15 -15.0

[-18.2, -11.8] <

0.001 -6.1

[-9.6, -2.7] <

0.001 -1.0

[-16.0, 13.9] 1

10.3 [-48.4, 69.0]

1 -11.8

[-26.9, 3.3] 0.23

-11.9 [-21.3, -2.4]

0.004

5 10 -4.7

[-8.6, -0.8] 0.007

-3.2 [-7.2, 0.7]

0.19 2.3

[-17.4, 22.0] 1

-12.9 [-44.8, 18.9]

0.83 -13.0

[-29.1, 3.2] 0.20

-4.7 [-14.6, 5.1]

0.79

5 15 -8.6

[-12.4, -4.9] <

0.001 -4.3

[-8.1, -0.5] 0.02

1.8 [-15.5, 19.0]

1 4.5

[-49.8, 58.8] 1

-11.6 [-29.5, 6.4]

0.45 -8.4

[-18.7, 2.0] 0.21

10 15 -4.0

[-7.4, -0.5] 0.01

-1.0 [-5.0, 2.9]

0.99 -0.5

[-20.3, 19.2] 1

17.4 [-39.4, 74.2]

0.95 1.4

[-13.7, 16.5] 1

-3.6 [-12.7, 5.5]

0.91

Table 4.4 (see previous page for caption)

Page 78: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

67

4.4 Discussion

4.4.1 Fixation displacement across sessions and relationship to location of peak cone density Previous work looking at the stability of the fixation locus shows relative stability of the

fixation center, with a shift of ~2-4 arcmin across days (Putnam, 2012). The standard

deviation of fixation has been reported to be anywhere between 1-5 arcmin (Barlow, 1952;

Ditchburn, 1973; Putnam et al., 2005; Steinman, 1965). In the current study, fixation shifted

by an average of 1.2 arcmin across days; the fixation spread had a mean standard deviation

of approximately 2.6 arcmin (Table 4.1). The mean displacement of fixation from location

of peak cone density has been previously shown to be between 5 and 9.8 arcmin (Li et al.,

2010; Putnam et al., 2005) whereas in the current study mean displacement was 3.8

arcmin (Table 4.1; Figure 4.2). A potential reason for the variability in findings across

studies could be the characteristics of the stimulus used, which has been shown to affect

fixation behavior (Steinman, 1965). The stimulus employed in Putnam et al.’s 2005 study

was a 1 degree Maltese cross (Putnam et al., 2005), a 6 arcmin square in Li et al. (Li et al.,

2010), and a 5 arcmin spot in the current study. The larger size of the Maltese cross

coupled with a larger spectral bandwidth may have necessitated a less specific fixation

location across days than the significantly smaller target used in our study. Additionally,

different adaptive optics systems were used in the 2005, 2010, and current studies, so

differences in stimulus resolution, luminance, and delivery wavelength can also explain

discrepancies with the present work.

Cone density measurements in the 2005, 2010, and current studies were derived by

manually identifying cones within an approximately 1-2° region in the central retina, the

coordinates of which were then scanned into a moving sampling window in which the

number of cones was measured and converted into cone density (Curcio et al., 1990).

Inconsistencies in sampling window size across studies or errors in manual cone selection

can affect estimates of peak cone density location. The potential error in determining peak

cone density can therefore result in dissimilar results across reports.

4.4.2 Mapping acuity within the central fovea In the current study we were interested in measuring acuity in discrete locations within the

central 0.5° of the fovea by stabilizing stimuli in regions at 5-arcmin intervals. Weymouth,

et al. mapped grating acuity at 11-arcmin intervals across the central fovea and found that

acuity was highest at and declined away from the PRL when ocular blur is uncompensated

(Weymouth et al., 1928). Since ocular blur precludes the cone sampling limit from being

the limiting factor for acuity, we were interested in mapping acuity within a central small

foveal region (~20-arcmin in diameter) to assess whether acuity declined at smaller

intervals when ocular blur was compensated for and performance was truly sampling-

Page 79: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

68

limited. Histology shows that cone density declines as close as 10-arcmin from the location

of peak cone density, although the steepness of the decline varies greatly across subjects

(Curcio et al., 1990). Since acuity is closely matched to the sampling limit within the central

0.5° of the fovea (Rossi & Roorda, 2010a), we would expect acuity to reflect the drop-off in

cone density within this region. Our findings, however, did not indicate any significant

differences in acuity across the central 20-arcminute region (Figure 4.3). This observation

may be due to multiple factors, including intersubject variability in cone density

distribution within the fovea which may affect where cone density and acuity begin to

noticeably decline. Another factor could be the nature of the protocol and stimulus used in

the current study to measure acuity thresholds. For consistency with our previous study

(Chapter 3) and due to difficulties in presenting and analyzing stimuli with varying contrast

using the AOSLO, we decided to use a maximum-contrast tumbling ‘E’ for the current work.

Thresholds measured with a tumbling ‘E’ are based on the width of each ‘leg’, presumably

the main feature used to discriminate orientation. However, the tumbling ‘E’ also has lower

frequency cues that can be used for orientation discrimination (Bondarko & Danilova,

1997), thus muddling the relationship between stimulus size and spatial frequency

threshold. It is unlikely our subjects relied solely on lower frequency cues during the acuity

task since their thresholds more closely matched the spatial frequency corresponding to

the legs of the ‘E’. However, it should be emphasized that the broader spectrum of our

stimuli makes the relationship between cone sampling limit and stimulus threshold more

complex.

The QUEST paradigm is an adaptive psychometric procedure in which the stimulus size

chosen for each trial is based on the most probable Bayesian estimate of threshold (Watson

& Pelli, 1983). This allows one to quickly and efficiently determine threshold within several

dozen rather than several hundred trials, an important distinction when measuring

thresholds across several locations and when the number of trials required becomes

prohibitively large. The downside of using a Bayesian procedure is that the shape of the

psychometric function must be initially assumed; since the true shape is never measured,

any discrepancies between the assumed and actual shape can lead to errors in threshold

determination. Classical methods such as method of constant stimuli have fewer

assumptions but are much more time consuming, which would have been prohibitive in the

current study in which acuity was measured twice over 9 locations in a single session.

Therefore QUEST was the best option for threshold determination in spite of its limitations.

4.4.3 Fixational eye movements by initial stimulus location During Session 2 we presented stimuli at the lowest threshold derived from Session 1 at 5-

arcmin intervals from the fixation center along the horizontal meridian. The purpose of this

experiment was to observe the characteristics of fixational eye movements depending on

stimulus start point and whether microsaccades played a role in refoveating stimuli to an

Page 80: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

69

ideal location. Whereas subjects S3 and S4 made microsaccades in less than ~20% of all

trials, S1, S2, S5, and S6 showed a bias toward exhibiting more microsaccades the further

away the stimulus start point was from the fixation center (Figure 4.5). When the

orientations and amplitudes of the initial microsaccades per trial were analyzed, these four

subjects showed a systematic trend in microsaccade orientation and amplitude depending

on stimulus start point (Figure 4.4; Tables 4.2 & 4.4), with an overall tendency for the

initial microsaccade to bring the stimulus closer to the fixation center (Table 4.3). Since

subjects S3 and S4 rarely made microsaccades, we analyzed their drift characteristics

(Figure 4.6) to determine whether drift had a tendency to relocate peripheral targets closer

to the fixation center. We did not find this to be the case with these two subjects and in fact

drift orientation appeared to be mostly random with a slight orientation bias that was

consistent across stimulus locations. A larger analysis of drift across all subjects also

showed idiosyncracies in drift orientation that were independent of relative stimulus

orientation (Figure 4.7). Thus, it appears that microsaccades alone served to relocate

stimuli closer to the fixation center, even if the targets were displaced from fixation by

several arcminutes only, results that are consistent with earlier findings (Ko et al., 2010;

Poletti et al., 2013). An analysis of microsaccade onset relative to stimulus presentation

showed the mean onset time for subjects S1, S2, S5, and S6 to be 315 msec (Supplementary

Figure S4.1); in comparison, saccadic latencies in response to peripheral stimuli are

generally 200-250 msec (Cohen & Ross, 1978; Saslow, 1967). The latencies observed in this

study are similar but slightly longer than those observed for larger saccades, but this

variation can be caused by numerous factors, including stimulus saliency and observer

training. Overall, our results support the theory that microsaccades serve a similar, but

more precise, purpose to larger saccades in relocating gaze.

We also analyzed whether there was tendency for the initial microsaccade to relocate the

stimulus closer to the location of peak cone density than to the original fixation center

(Table 4.1 & 4.3). We found this to be the case with S1 only. Since acuity was relatively

homogeneous within the central 20 arcmin of fixation, it is unsurprising that subjects did

not necessarily shift their fixation behavior to use the retinal location with highest cone

density for this task.

A key point in Session 2’s protocol was that subjects were allowed to gaze directly at the

stimulus, a contrast from Session 1 in which stimuli were stabilized at retinal locations

peripheral to the PRL and subjects had a strong sense that they weren’t gazing directly at

the stimulus. Assuming in Session 2 that subjects opted to gaze directly at the stimulus and

that the initial microsaccade served to refoveate peripheral stimuli, the analysis from Table

4.4 (visualized in Figure 4.9) can provide insight into the expanse of the fixational ‘dead

zone,’ or the region surrounding the fixation center in which a stimulus appears to be

within the subjective location of gaze. Table 4.4 and Figure 4.9 provide statistical analyses

Page 81: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

70

in which microsaccade characteristics were compared across different stimulus start

points. Comparing microsaccade amplitudes at the fixation center to those at more

peripheral locations can serve as a determinant for the smallest eccentricity at which

fixation behavior, i.e. microsaccade amplitude, significantly changed. Of the four subjects

that showed shifting microsaccade behavior with stimulus location, S1 and S2 exhibited

significant changes in microsaccade amplitude beginning at a 5-arcmin eccentricity from

fixation. In other words, their fixational ‘dead zone’ was restricted to a 5-arcmin radius

from the fixation center (Figure 4.9). Subject S5 did not exhibit a boundary to their dead

zone within the tested 15-arcmin-radius region, and S6’s dead zone had a 10-arcmin

radius. The extent of the fixational dead zone, or subjective line-of-sight, appears to be

correlated with the spread of the PRL measured during Session 2, as S1 and S2 exhibited

the smallest fixational SD, followed by S6 and lastly S5. The smaller the SD, the narrower

the dead zone appeared to be. S3 and S4, the two subjects who made minimal

microsaccades, had smaller fixational spread than S5, so it is unclear why they failed to

employ microsaccades to relocate gaze. An interesting observation is that subjects S1 and

S2, who exhibited the smallest PRL and strongest inclination for using microsaccades to

refoveate eccentric stimuli, were the only two individuals with prior experience as AOSLO

subjects, especially with performing high-acuity discrimination tasks. The remaining

subjects had no prior experience participating in AOSLO experiments. It could be then that

with additional experience, these subjects would eventually optimize their fixational

behavior and employ microsaccades more systematically for relocating gaze, which would

be in line with earlier observations showing that microsaccade characteristics vary with

observer training on a fixation task (Cherici et al., 2012).

Our results show that while the preferred retinal locus is relatively stable across days, the

spread of fixation is variable across subjects. Mapping acuity at 5-arcmin intervals across

the central fovea did not show a noticeable decline in performance, although these tests

were restricted to a 10-arcmin radius from fixation. Future work should repeat sub-foveal

acuity measurements with a more suitable stimulus than the tumbling ‘E’ to better restrict

the spatial frequencies available for orientation discrimination. The majority of our

subjects employed microsaccades to relocate peripherally-presented stimulus closer to the

fixation center, even when stimuli were restricted to a 15-arcmin radius from the fixation

locus. This finding supports the theory that microsaccades serve a similar function to larger

saccades, even for stimuli presented within the central 0.5° of the fovea. Our subjects

displayed fixational ‘dead zones’ as small as 10-arcmin in diameter, and more experienced

subjects appeared to have smaller subjective regions of gaze. It is possible then that with

continued experience, subjects may develop fixational behaviors that employ

microsaccades for optimizing visual performance.

Page 82: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

71

Overall, our study is consistent with earlier reports showing that the visual system has a

preferential location for fixation, demonstrated by the consistency in PRL location across

days (Putnam, 2012; Putnam, Hammer, Zhang, Merino, & Roorda, 2010) and the utility of

microsaccades in relocating peripheral stimuli as close as 5 arcminutes from the fixation

center (Ko et al., 2010; Poletti et al., 2013). Although this location does not appear to match

the location of maximum sampling and is impervious to the relative homogeneity of acuity

within the fovea, there are other factors unmeasurable with the current experimental setup

that may influence the foveal location used for fixation. Photopigment optical density, a

function of the pigment’s chromatic spectrum, concentration, and path length, is variable

within the foveola and affects a cone’s capacity for absorbing light. Receptive field pooling,

or the number of photoreceptors that provide input to higher retinal neurons, dictates the

effective retinal sampling limit at the level of ganglion cells. Additionally, cortical

magnification, or the area in the visual cortex that processes stimuli within a specific region

of the visual field, can affect visual attention and saliency in a manner that optimizes a

specific foveal location for fixation. The interaction of these factors in determining a

preferred retinal locus is still unknown, although it is clear that eye movements, and in

particular microsaccades, serve a crucial role in maintaining a specific retinal location for

fixation.

4.5 Acknowledgements

The efforts (experimental design, data acquisition, and analysis) described in this chapter

were performed by the author with feedback from Austin Roorda. The author thanks

Nicolas Bensaid and Pavan Tiruveedhula for their engineering and technical assistance and

Norick Bowers for his work on a toolbox for eye movement analysis.

Page 83: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

72

4.6 Supplementary Figure

Figure S4.1 | Initial microsaccade probability relative to stimulus onset. Normalized probability of the initial microsaccade per trial relative to stimulus onset. Shaded regions indicate standard error of mean. Written values indicate mean (± SEM) onset time in milliseconds of first microsaccade.

Page 84: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

73

Bibliography

Ahissar, E., & Arieli, A. (2012). Seeing via Miniature Eye Movements: A Dynamic Hypothesis for Vision. Frontiers in Computational Neuroscience, 6, 89. https://doi.org/10.3389/fncom.2012.00089

Ahissar, E., Ozana, S., & Arieli, A. (2015). 1-D Vision: Encoding of Eye Movements by Simple Receptive Fields. Perception, 44(8–9), 986–94. https://doi.org/10.1177/0301006615594946

Ahnelt, P. K. (1998). The photoreceptor mosaic. Eye (London, England), 12 ( Pt 3b, 531–540.

Akeo, K., Hilda, Y., Saga, M., Inoue, R., & Oguchi, Y. (2002). Correlation between contrast sensitivity and visual acuity in retinitis pigmentosa patients. Ophthalmologica, 216, 185–191.

Alexander, K. R., Derlacki, D. J., Fishman, G. A., & Szlyk, J. P. (1992). Grating, vernier, and letter acuity in retinitis pigmentosa. Investigative Ophthalmology & Visual Science, 33(12), 3400–6. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/1428713

Alexander, K. R., Hutman, L. P., & Fishman, G. A. (1986). Dark-Adapted Foveal Thresholds and Visual Acuity in Retinitis Pigmentosa. Archives of Ophthalmology, 104(3), 390–394. https://doi.org/10.1001/archopht.1986.01050150090034

Anderson, A., Ratnam, K., Roorda, A., & Olshausen, B. (2016). A neural model of high acuity vision in the presence of fixational eye movements. In Asilomar Conference on Signals, Systems, and Computers.

Arathorn, D. W., Stevenson, S. B., Yang, Q., Tiruveedhula, P., & Roorda, A. (2013). How the unstable eye sees a stable and moving world. Journal of Vision, 13(10), 22. https://doi.org/10.1167/13.10.22

Arathorn, D. W., Yang, Q., Vogel, C. R., Zhang, Y., Tiruveedhula, P., & Roorda, A. (2007). Retinally stabilized cone-targeted stimulus delivery. Optics Express, 15(21), 13731–44. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/19550644

Arathorn, D. W., Yang, Q., Vogel, C. R., Zhang, Y., Tiruveedhula, P., & Roorda, A. (2007). Retinally stabilized cone-targeted stimulus delivery. Optics Express, 15(21), 13731–13744. https://doi.org/10.1364/OE.15.013731

Arditi, A., & Cagenello, R. (1993). On the statistical reliability of letter-chart visual acuity measurements. Investigative Ophthalmology & Visual Science, 34(1), 120–9. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/8425819

Arend, L. (1973). Spatial differential and integral operations in human vision: Implications of stabilized retinal image fading. Psychological Review, 80(5), 374–395. https://doi.org/10.1037/h0020072

Page 85: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

74

Averill, H., & Weymouth, F. (1925). Visual perception and the retinal mosaic, II. The influence of eye movements on the displacement threshold. Journal of Comparative Psychology, 5, 147–176.

Bailey, I. L., & Lovie, J. E. (1976). New design principles for visual acuity letter charts. American Journal of Optometry and Physiological Optics, 53(11), 740–5. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/998716

Barlow, H. (1952). Eye Movements During Fixation. Journal of Physiology, 116, 290–306.

Barlow, H. (1979). Reconstructing the visual image in space and time. Nature, 279(5710), 189–90. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/440428

Baron, W. S., & Westheimer, G. (1973). Visual acuity as a function of exposure duration. Journal of the Optical Society of America, 63(2), 212–9. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/4700788

Bedggood, P., & Metha, A. (2012). Direct visualization and characterization of erythrocyte flow in human retinal capillaries. Biomedical Optics Express, 3(12), 3264–77. https://doi.org/10.1364/BOE.3.003264

Ben-Ezra, M., Zomet, A., & Nayar, S. (2005). Video super-resolution using controlled subpixel detector shifts. In IEEE Transactions on Pattern Analysis and Machine Intelligence (pp. 977–987).

Bennett, A. G., Rudnicka, A. R., & Edgar, D. F. (1994). Improvements on Littmann’s method of determining the size of retinal features by fundus photography. Graefes Arch Clin Exp Ophthalmol, 232(6), 361–7. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/8082844

Berson, E. L., Sandberg, M. A., Rosner, B., Birch, D. G., & Hanson, A. H. (1985). Natural course of retinitis pigmentosa over a three-year interval. American Journal of Ophthalmology, 99(3), 240–51. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/3976802

Birch, D. G., Sandberg, M. a, & Berson, E. L. (1982). The Stiles-Crawford effect in retinitis pigmentosa. Investigative Ophthalmology & Visual Science, 22(2), 157–164.

Bittner, A. K., Ibrahim, M. A., Haythornthwaite, J. A., Diener-West, M., & Dagnelie, G. (2011). Vision Test Variability in Retinitis Pigmentosa and Psychosocial Factors. Optometry and Vision Science, 88(12), 1496–506. https://doi.org/10.1097/OPX.0b013e3182348d0b

Bondarko, V. M., & Danilova, M. V. (1997). What spatial frequency do we use to detect the orientation of a Landolt C? Vision Research, 37(15), 2153–6. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/9327062

Born, M., & Wolf, E. (1989). The Diffraction Theory of Aberrations. In Principles of Optics: Electromagnetic Theory of Propagation, Interference, and Diffraction of Light (6th ed.,

Page 86: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

75

pp. 459–490). New York: Pergamon Press.

Bridgeman, B., & Palca, J. (1980). The role of microsaccades in high acuity observational tasks. Vision Research, 20(9), 813–7. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/7456343

Burak, Y., Rokni, U., Meister, M., & Sompolinsky, H. (2010). Bayesian model of dynamic image stabilization in the visual system. Proceedings of the National Academy of Sciences of the United States of America, 107(45), 19525–30. https://doi.org/10.1073/pnas.1006076107

Carroll, J., Dubra, A., Gardner, J. C., Mizrahi-Meissonnier, L., Cooper, R. F., Dubis, A. M., … Michaelides, M. (2012). The effect of cone opsin mutations on retinal structure and the integrity of the photoreceptor mosaic. Investigative Ophthalmology & Visual Science, 53(13), 8006–15. https://doi.org/10.1167/iovs.12-11087

Carroll, J., Kay, D. B., Scoles, D., Dubra, A., & Lombardo, M. (2013). Adaptive optics retinal imaging--clinical opportunities and challenges. Current Eye Research, 38(7), 709–21. https://doi.org/10.3109/02713683.2013.784792

Chen, Y., Ratnam, K., Sundquist, S. M., Lujan, B., Ayyagari, R., Gudiseva, V. H., … Duncan, J. L. (2011). Cone photoreceptor abnormalities correlate with vision loss in patients with Stargardt disease. Investigative Opthalmology & Visual Science, 52(6), 3281–3292.

Cherici, C., Kuang, X., Poletti, M., & Rucci, M. (2012). Precision of sustained fixation in trained and untrained observers. Journal of Vision, 12(6), 31–31. https://doi.org/10.1167/12.6.31

Choi, S. S., Doble, N., Hardy, J. L., Jones, S. M., Keltner, J. L., Olivier, S. S., & Werner, J. S. (2006). In Vivo Imaging of the Photoreceptor Mosaic in Retinal Dystrophies and Correlations with Visual Function. Investigative Opthalmology & Visual Science, 47, 2080–2092. https://doi.org/10.1167/iovs.05-0997.In

Chui, T., Song, H., & Burns, S. (2008). Individual Variations in Human Cone Photoreceptor Packing Density: Variations with Refractive Error. Investigative Opthalmology & Visual Science, 49(10), 4679–4687. https://doi.org/10.1167/iovs.08-2135.Individual

Chui, T. Y., Song, H., & Burns, S. a. (2008). Adaptive-optics imaging of human cone photoreceptor distribution. Journal of the Optical Society of America. A, Optics, Image Science, and Vision, 25(12), 3021–3029.

Coakley, D. (1983). Minute eye movement and brain stem function. Boca Raton, FL: CRC Press.

Cohen, M. E., & Ross, L. E. (1978). Latency and accuracy characteristics of saccades in children and adults. Journal of Experimental Child Psychology, 26, 517–527.

Crick, F., Marr, D., & Poggio, T. (1981). An information-processing approach to

Page 87: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

76

understanding the visual cortex. In F. Schmitt (Ed.), The organization of the cerebral cortex. Cambridge, MA: MIT Press.

Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990). Human photoreceptor topography. Journal of Comparative Neurology, 292(4), 497–523.

Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990). Human photoreceptor topography. Journal of Comparative Neurology, 292(4), 497–523. https://doi.org/10.1002/cne.902920402

Dacey, D. M. (1993). The mosaic of midget ganglion cells in the human retina. Journal of Neuroscience, 13(12), 5334–55. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/8254378

Dagnelie, G. (2012). Retinal implants: emergence of a multidisciplinary field. Current Opinion in Neurology, 25(1), 67–75. https://doi.org/10.1097/WCO.0b013e32834f02c3

Davidson, A., & Hinkley, D. (1997). Bootstrap Methods and Their Application. Cambridge University Press.

Ditchburn, R. (1973). Eye Movements and Visual Perception. Oxford, UK: Clarendon Press.

Ditchburn, R., & Ginsborg, B. (1952). Vision with a stabilized retinal image. Nature, 170, 36–37.

Dubra, A., & Sulai, Y. (2011). Reflective afocal broadband adaptive optics scanning ophthalmoscope. Biomedical Optics Express, 2(6), 1757–1768.

Duncan, J. L., Ratnam, K., Birch, D. G., Sundquist, S. M., Lucero, A. S., Zhang, Y., … Roorda, A. (2011). Abnormal cone structure in foveal schisis cavities in X-linked retinoschisis from mutations in exon 6 of the RS1 gene. Investigative Ophthalmology & Visual Science, 52(13), 9614–23. https://doi.org/10.1167/iovs.11-8600

Duncan, J. L., Roorda, A., Navani, M., Vishweswaraiah, S., Syed, R., Soudry, S., … Ayyagari, R. (2012). Identification of a novel mutation in the CDHR1 gene in a family with recessive retinal degeneration. Archives of Ophthalmology, 130(10), 1301–8. https://doi.org/10.1001/archophthalmol.2012.1906

Duncan, J. L., Talcott, K. E., Ratnam, K., Sundquist, S. M., Lucero, A. S., Day, S., … Roorda, A. (2011). Cone structure in retinal degeneration associated with mutations in the peripherin/RDS gene. Investigative Opthalmology & Visual Science, 52(3), 1557–1566.

Duncan, J. L., Zhang, Y., Gandhi, J., Nakanishi, C., Othman, M., Branham, K. E. H., … Roorda, A. (2007). High-resolution imaging with adaptive optics in patients with inherited retinal degeneration. Investigative Opthalmology & Visual Science, 48(7), 3283–3291. https://doi.org/10.1167/iovs.06-1422

Eagle, R. C., Lucier, A. C., Bernardino, V. B., & Yanoff, M. (1980). Retinal pigment epithelial abnormalities in fundus flavimaculatus: a light and electron microscopic study.

Page 88: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

77

Ophthalmology, 87(12), 1189–200. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/6165950

Early Treatment Diabetic Retinopathy Study Research Group. Photocoagulation for diabetic macular edema: Early Treatment Diabetic Retinopathy Study report number 1. (1985). Archives of Ophthalmology, 103, 1796–1806.

Eizenman, M., Hallett, P. E., & Frecker, R. C. (1985). Power spectra for ocular drift and tremor. Vision Research, 25(11), 1635–40. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/3832587

Elliott, D. B. (1993). Evaluating visual function in cataract. Optometry and Vision Science : Official Publication of the American Academy of Optometry, 70(11), 896–902. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/8302525

Elliott, D. B., & Sheridan, M. (1988). The use of accurate visual acuity measurements in clinical anti-cataract formulation trials. Ophthalmic & Physiological Optics , 8(4), 397–401. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/3253632

Elsner, A. E., Burns, S. A., & Lobes, L. A. (1987). Foveal cone optical density in retinitis pigmentosa. Applied Optics, 26(8), 1378–84. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/20454331

Engbert, R., Mergenthaler, K., Sinn, P., & Pikovsky, A. (2011). An integrated model of fixational eye movements and microsaccades. Proceedings of the National Academy of Sciences, 108(39), E765–E770. https://doi.org/10.1073/pnas.1102730108

Ergun, E., Hermann, B., Wirtitsch, M., Unterhuber, A., Ko, T. H., Sattmann, H., … Drexler, W. (2005). Assessment of central visual function in Stargardt’s disease/fundus flavimaculatus with ultrahigh-resolution optical coherence tomography. Investigative Ophthalmology & Visual Science, 46(1), 310–6. https://doi.org/10.1167/iovs.04-0212

Farsiu, S., Robinson, D., Elad, M., & Milanfar, P. (2004). Fast and robust multi-frame super-resolution. In IEEE Transactions on Image Processing (pp. 1327–1344).

Ferris, F. L., Kassoff, A., Bresnick, G. H., & Bailey, I. (1982). New visual acuity charts for clinical research. American Journal of Ophthalmology, 94(1), 91–6. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/7091289

Fishman, G. A., Bozbeyoglu, S., Massof, R. W., & Kimberling, W. (2007). Natural course of visual field loss in patients with Type 2 Usher syndrome. Retina , 27(5), 601–8. https://doi.org/10.1097/01.iae.0000246675.88911.2c

Fishman, G. A., Gilbert, L. D., Anderson, R. J., Marmor, M. F., Weleber, R. G., & Viana, M. A. (1994). Effect of methazolamide on chronic macular edema in patients with retinitis pigmentosa. Ophthalmology, 101(4), 687–93. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/8152764

Page 89: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

78

Flannery, J. G., Farber, D. B., Bird, A. C., & Bok, D. (1989). Degenerative changes in a retina affected with autosomal dominant retinitis pigmentosa. Investigative Ophthalmology & Visual Science, 30(2), 191–211. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/2914751

Geller, A. M., & Sieving, P. A. (1993). Assessment of foveal cone photoreceptors in Stargardt’s macular dystrophy using a small dot detection task. Vision Research, 33(11), 1509–1524.

Geller, A. M., Sieving, P. A., & Green, D. G. (1992). Effect on grating identification of sampling with degenerate arrays. Journal of the Optical Society of America, 9(3), 472–7. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/1548555

Grieve, K., Tiruveedhula, P., Zhang, Y., & Roorda, A. (2006). Multi-wavelength imaging with the adaptive optics scanning laser Ophthalmoscope. Optics Express, 14(25), 12230–42. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/19529652

Grover, S., Fishman, G. A., Anderson, R. J., Alexander, K. R., & Derlacki, D. J. (1997). Rate of visual field loss in retinitis pigmentosa. Ophthalmology, 104(3), 460–5. https://doi.org/10.1016/S0161-6420(97)30291-7

Grover, S., Fishman, G. A., Gilbert, L. D., & Anderson, R. J. (1997). Reproducibility of visual acuity measurements in patients with retinitis pigmentosa. Retina (Philadelphia, Pa.), 17(1), 33–7. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/9051840

Hardy, J. W., Lefebvre, J. E., & Koliopoulos, C. L. (1977). Real-time atmospheric compensation. Journal of the Optical Society of America, 67(3), 360. https://doi.org/10.1364/JOSA.67.000360

Harmening, W. M., Tuten, W. S., Roorda, A., & Sincich, L. C. (2014). Mapping the perceptual grain of the human retina. Journal of Neuroscience, 34(16), 5667–77. https://doi.org/10.1523/JNEUROSCI.5191-13.2014

Hartmann, J. (1900). Bemerkungen über den Bau und die Justirung von Spektrographen. Zeitschrift Für Instrumentenkunde, (20), 17–27.

Hartong, D. T., Berson, E. L., & Dryja, T. P. (2006). Retinitis pigmentosa. Lancet , 368(9549), 1795–809. https://doi.org/10.1016/S0140-6736(06)69740-7

Havermann, K., Cherici, C., Rucci, M., & Lappe, M. (2014). Fine-Scale Plasticity of Microscopic Saccades. Journal of Neuroscience, 34(35), 11665–11672. https://doi.org/10.1523/JNEUROSCI.5277-13.2014

Helmholtz, H. von. (1962). Popular scientific lectures. (M. Kline, Ed.). New York: Dover.

Hennig, M., & Worgotter, F. (2004). Eye micro-movements improve stimulus detection beyond the Nyquist limit in the peripheral retina. In S. Thrun, L. Saul, & B. Scholkopf (Eds.), Advances in Neural Information Processing Systems (pp. 1475–1482).

Page 90: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

79

Cambridge, MA: MIT Press.

Holden, B. A., Fricke, T. R., Wilson, D. A., Jong, M., Naidoo, K. S., Sankaridurg, P., … Resnikoff, S. (2016). Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050. Ophthalmology, 123, 1036–1042. https://doi.org/10.1016/j.ophtha.2016.01.006

Holopigian, K., Greenstein, V., Seiple, W., & Carr, R. E. (1996). Rates of change differ among measures of visual function in patients with retinitis pigmentosa. Ophthalmology, 103(3), 398–405. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/8600415

Iannaccone, A., Kritchevsky, S. B., Ciccarelli, M. L., Tedesco, S. A., Macaluso, C., Kimberling, W. J., & Somes, G. W. (2004). Kinetics of visual field loss in Usher syndrome Type II. Investigative Ophthalmology & Visual Science, 45(3), 784–92. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/14985291

Kelly, D. (1979). Motion and vision. I. Stabilized images of stationary gratings. Journal of Optical Society of America, 69, 1266–1274.

Kilbride, P. E., Fishman, M., Fishman, G. A., & Hutman, L. P. (1986). Foveal cone pigment density difference and reflectance in retinitis pigmentosa. Archives of Ophthalmology, 104(2), 220–4. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/3947297

Kim, L. S., McAnany, J. J., Alexander, K. R., & Fishman, G. A. (2007). Intersession Repeatability of Humphrey Perimetry Measurements in Patients with Retinitis Pigmentosa. Investigative Opthalmology & Visual Science, 48(10), 4720. https://doi.org/10.1167/iovs.07-0690

Kiser, A. K., Mladenovich, D., Eshraghi, F., Bourdeau, D., & Dagnelie, G. (2005). Reliability and consistency of visual acuity and contrast sensitivity measures in advanced eye disease. Optometry and Vision Science, 82(11), 946–54. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/16317369

Klein, S. A., & Levi, D. M. (1985). Hyperacuity thresholds of 1 sec: theoretical predictions and empirical validation. Journal of the Optical Society of America, 2(7), 1170–90. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/4020514

Ko, H.-K., Poletti, M., & Rucci, M. (2010). Microsaccades precisely relocate gaze in a high visual acuity task. Nature Neuroscience, 13(12), 1549–53. https://doi.org/10.1038/nn.2663

Kuang, X., Poletti, M., Victor, J. D., & Rucci, M. (2012). Temporal encoding of spatial information during active visual fixation. Current Biology, 22(6), 510–4. https://doi.org/10.1016/j.cub.2012.01.050

Larsen, J. S. (1971). The sagittal growth of the eye. II. Ultrasonic measurement of the axial diameter of the lens and the anterior segment from birth to puberty. Acta Ophthalmologica, 49(3), 427–40. Retrieved from

Page 91: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

80

http://www.ncbi.nlm.nih.gov/pubmed/5171608

Li, K., Tiruveedhula, P., & Roorda, A. (2010). Intersubject variability of foveal cone photoreceptor density in relation to eye length. Investigative Ophthalmology & Visual Science, 51(12), 6858–6867. https://doi.org/10.1167/iovs.10-5499

Li, K. Y., & Roorda, A. (2007). Automated identification of cone photoreceptors in adaptive optics retinal images. Journal of the Optical Society of America. A, Optics, Image Science, and Vision, 24(5), 1358–63. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/17429481

Liang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994). Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. J. Opt. Soc. Am. A, 11(7).

Liang, J., & Williams, D. R. (1997). Aberrations and retinal image quality of the normal human eye. Journal of the Optical Society of America A, 14(11), 2873. https://doi.org/10.1364/JOSAA.14.002873

Liang, J., Williams, D. R., & Miller, D. T. (1997). Supernormal vision and high-resolution retinal imaging through adaptive optics. Journal of the Optical Society of America. A, Optics, Image Science, and Vision, 14(11), 2884–92. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/9379246

Lindberg, C. R., Fishman, G. a, Anderson, R. J., & Vasquez, V. (1981). Contrast sensitivity in retinitis pigmentosa. British Journal of Ophthalmology, 65(12), 855–858. Retrieved from http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=7317333

Loumou, P., Griffin, S., Ratnam, K., Porco, T., Qin, J., Roorda, A., & Duncan, J. L. (2016). Relationship between foveal cone structure and visual acuity measured with adaptive optics scanning laser ophthalmoscopy in retinal degenerations and normal subjects. San Francisco.

MacLeod, D., Williams, D., & Makous, W. (1992). A visual nonlinearity fed by single cones. Vision Research, 32, 347–363.

Madreperla, S. A., Palmer, R. W., Massof, R. W., & Finkelstein, D. (1990). Visual Acuity Loss in Retinitis Pigmentosa: Relationship to Visual Field Loss. Archives of Ophthalmology, 108, 358–361.

Makous, W., Carroll, J., Wolfing, J. I., Lin, J., Christie, N., & Williams, D. R. (2006). Retinal Microscotomas Revealed with Adaptive-Optics Microflashes. Investigative Opthalmology & Visual Science, 47(9), 4160–7. https://doi.org/10.1167/iovs.05-1195

Marcos, S., & Navarro, R. (1997). Determination of the foveal cone spacing by ocular speckle interferometry: limiting factors and acuity predictions. Journal of the Optical Society of

Page 92: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

81

America. A, Optics, Image Science, and Vision, 14(4), 731–40. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/9088086

Marshall, W., & Talbot, S. (1942). Recent evidence for neural mechanisms in vision leading to a general theory of sensory acuity. Biological Symposia- Visual Mechanisms, 7, 117–164.

Martinez-Conde, S., Macknik, S. L., & Hubel, D. H. (2004). The role of fixational eye movements in visual perception. Nature Reviews. Neuroscience, 5(3), 229–40. https://doi.org/10.1038/nrn1348

Massof, R. W., Dagnelie, G., Benzschawel, T., Palmer, R. W., & Finkel stein, D. (1990). First order dynamics of visual field loss in retinitis pigmentosa. Clinical Vision Sciences, 5(1), 1–26.

Merino, D., Duncan, J. L., Tiruveedhula, P., & Roorda, A. (2011). Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope. Biomedical Optics Express, 2(8), 2189–2201.

Murakami, I. (2003). Illusory jitter in a static stimulus surrounded by a synchronously flickering pattern. Vision Research, 43(9), 957–69. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/12676240

Panda-Jonas, S., Jonas, J. B., & Jakobczyk-Zmija, M. (1995). Retinal photoreceptor density decreases with age. Ophthalmology, 102(12), 1853–9. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/9098287

Pitkow, X., Sompolinsky, H., & Meister, M. (2007). A neural computation for visual acuity in the presence of eye movements. PLoS Biology, 5(12), e331. https://doi.org/10.1371/journal.pbio.0050331

Platt, B. C., & Shack, R. (2001). History and principles of Shack-Hartmann wavefront sensing. Journal of Refractive Surgery (Thorofare, N.J. : 1995), 17(5), S573-7. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/11583233

Poletti, M., Listorti, C., & Rucci, M. (2013). Microscopic eye movements compensate for nonhomogeneous vision within the fovea. Current Biology, 23(17), 1691–1695. https://doi.org/10.1016/j.cub.2013.07.007

Poletti, M., & Rucci, M. (2010). Eye movements under various conditions of image fading. Journal of Vision, 10(3), 1–18. https://doi.org/10.1167/10.3.6

Poonja, S., Patel, S., Henry, L., & Roorda, A. (2005). Dynamic visual stimulus presentation in an adaptive optics scanning laser ophthalmoscope. Journal of Refractive Surgery (Thorofare, N.J. : 1995), 21(5), S575-80. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/16209464

Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001). Monochromatic aberrations of the

Page 93: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

82

human eye in a large population. Journal of the Optical Society of America. A, Optics, Image Science, and Vision, 18(8), 1793–803. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/11488483

Putnam, N. M. (2012). Characterization of the structure and function of the normal human fovea using adaptive optics scanning laser ophthalmoscopy. Berkeley: ProQuest.

Putnam, N. M., Hammer, D. X., Zhang, Y., Merino, D., & Roorda, A. (2010). Modeling the foveal cone mosaic imaged with adaptive optics scanning laser ophthalmoscopy. Optics Express, 18(24), 24902–16. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/21164835

Putnam, N. M., Hofer, H. J., Chen, L., & Williams, D. R. (2005). The locus of fixation and the foveal cone mosaic. Journal of Vision, 5, 632–639.

Ratnam, K., Västinsalo, H., Roorda, A., Sankila, E.-M. K., & Duncan, J. L. (2013). Cone structure in patients with usher syndrome type III and mutations in the Clarin 1 gene. JAMA Ophthalmology, 131, 67–74. https://doi.org/10.1001/2013.jamaophthalmol.2

Rha, J., Dubis, A. M., Wagner-Schuman, M., Tait, D. M., Godara, P., Schroeder, B., … Carroll, J. (2010). Spectral domain optical coherence tomography and adaptive optics: imaging photoreceptor layer morphology to interpret preclinical phenotypes. Advances in Experimental Medicine and Biology, 664, 309–16. https://doi.org/10.1007/978-1-4419-1399-9_35

Rha, J., Jonnal, R. S., Thorn, K. E., Qu, J., Zhang, Y., & Miller, D. T. (2006). Adaptive optics flood-illumination camera for high speed retinal imaging. Optics Express, 14(10), 4552–69. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/19516608

Riggs, L., & Ratliff, F. (1952). The effects of counteracting the normal movements of the eye. Journal of Optical Society of America, 42, 872–873.

Riggs, L., Ratliff, F., Cornsweet, J., & Cornsweet, T. (1953). The disappearance of steadily fixated visual test objects. Journal of Optical Society of America, 43(6), 495–501.

Roorda, A., & Duncan, J. L. (2015). Adaptive Optics Ophthalmoscopy. Annual Review of Vision Science, 1(1), 19–50. https://doi.org/10.1146/annurev-vision-082114-035357

Roorda, A., Romero-Borja, F., Donnelly Iii, W., Queener, H., Hebert, T., & Campbell, M. (2002). Adaptive optics scanning laser ophthalmoscopy. Optics Express, 10(9), 405–12. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/19436374

Roorda, A., & Williams, D. R. (1999). The arrangement of the three cone classes in the living human eye. Nature, 397(6719), 520–522. https://doi.org/10.1038/17383

Roorda, A., & Williams, D. R. (2002). Optical fiber properties of individual human cones. Journal of Vision, 2(5), 4. https://doi.org/10.1167/2.5.4

Roorda, A., Zhang, Y., & Duncan, J. L. (2007). High-Resolution In Vivo Imaging of the RPE

Page 94: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

83

Mosaic in Eyes with Retinal Disease. Investigative Opthalmology & Visual Science, 48(5), 2297–2303. https://doi.org/10.1167/iovs.06-1450

Ross, D. F., Fishman, G. A., Gilbert, L. D., & Anderson, R. J. (1984). Variability of Visual Field Measurements in Normal Subjects and Patients With Retinitis Pigmentosa. Archives of Ophthalmology, 102(7), 1004–1010. https://doi.org/10.1001/archopht.1984.01040030806021

Rossi, E. A., & Roorda, A. (2010a). Relationship between Visual Resolution and Cone Spacing in the Human Fovea, 13(2), 1–5. https://doi.org/10.1038/nn.2465.The

Rossi, E. A., & Roorda, A. (2010b). The relationship between visual resolution and cone spacing in the human fovea. Nature Neuroscience, 13(2), 156–157. https://doi.org/10.1038/nn.2465

Rossi, E. a, Weiser, P., Tarrant, J., & Roorda, A. (2007). Visual performance in emmetropia and low myopia after correction of high-order aberrations. Journal of Vision, 7(8), 14. https://doi.org/10.1167/7.8.14.Introduction

Rossi, E., Roorda, A., G., C. I., R., W. D., H., H., & I., C. (2010). Is visual resolution after adaptive optics correction susceptible to perceptual learning? Journal of Vision, 10(12), 11. https://doi.org/10.1167/10.12.11

Rucci, M., Iovin, R., Poletti, M., & Santini, F. (2007). Miniature eye movements enhance fine spatial detail. Nature, 447(7146), 851–4. https://doi.org/10.1038/nature05866

Rucci, M., & Victor, J. D. (2015). The unsteady eye: an information-processing stage, not a bug. Trends in Neurosciences, 38(4), 195–206. https://doi.org/10.1016/j.tins.2015.01.005

Sabesan, R., Hofer, H., & Roorda, A. (2015). Characterizing the Human Cone Photoreceptor Mosaic via Dynamic Photopigment Densitometry. PLOS ONE, 10(12), e0144891. https://doi.org/10.1371/journal.pone.0144891

Sadeghi, A. M., Eriksson, K., Kimberling, W. J., Sjöström, A., & Möller, C. (2006). Longterm visual prognosis in Usher syndrome types 1 and 2. Acta Ophthalmologica Scandinavica, 84(4), 537–544. https://doi.org/10.1111/j.1600-0420.2006.00675.x

Sandberg, M. A., Brockhurst, R. J., Gaudio, A. R., & Berson, E. L. (2005). The Association between Visual Acuity and Central Retinal Thickness in Retinitis Pigmentosa. Investigative Opthalmology & Visual Science, 46(9), 3349–54. https://doi.org/10.1167/iovs.04-1383

Sandberg, M. A., Rosner, B., Weigel-DiFranco, C., Dryja, T. P., & Berson, E. L. (2007). Disease course of patients with X-linked retinitis pigmentosa due to RPGR gene mutations. Investigative Ophthalmology & Visual Science, 48(3), 1298–1304. https://doi.org/10.1167/iovs.06-0971

Page 95: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

84

Saslow, M. (1967). Latency for saccadic eye movement. Journal of Optical Society of America, 57(8), 1030–1033.

Saud, A., Loumou, P., Ratnam, K., Griffin, S., Qin, J., Roorda, A., … Duncan, J. L. (2017). Structural loss precedes visual acuity loss in the fovea of patients with retinal degeneration. San Francisco.

Schieting, S., & Spillmann, L. (1987). Flicker adaptation in the peripheral retina. Vision Research, 27, 277–284.

Seiple, W., Clemens, C. J., Greenstein, V. C., Carr, R. E., & Holopigian, K. (2004). Test-retest reliability of the multifocal electroretinogram and Humphrey visual fields in patients with retinitis pigmentosa. Documenta Ophthalmologica, 109(3), 255–272. https://doi.org/10.1007/s10633-005-0567-0

Seiple, W., Holopigian, K., Szlyk, J. P., & Greenstein, V. C. (1995). The effects of random element loss on letter identification: implications for visual acuity loss in patients with retinitis pigmentosa. Vision Research, 35(14), 2057–2066.

Sincich, L. C., Zhang, Y., Tiruveedhula, P., Horton, J. C., & Roorda, A. (2009). Resolving single cone inputs to visual receptive fields. Nature Neuroscience, 12(8), 967–969. https://doi.org/10.1038/nn.2352

Song, H., Chui, T. Y., Zhong, Z., Elsner, A. E., & Burns, S. A. (2011). Variation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age. Investigative Ophthalmology & Visual Science, 52(10), 7376–7384. https://doi.org/10.1167/iovs.11-7199

Steinman, R. (1965). Effect of target size, luminance, and color on monocular fixation. Journal of Optical Society of America, 55(9), 1158–1165.

Steinman, R. M., Haddad, G. M., Skavenski, A. A., & Wyman, D. (1973). Miniature eye movement. Science , 181(4102), 810–9. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/4198903

Stevenson, S. B., & Roorda, A. (2005). Correcting for miniature eye movements in high resolution scanning laser ophthalmoscopy. In Biomedical Optics 2005 (pp. 145–151). International Society for Optics and Photonics.

Stevenson, S. B., & Roorda, A. (2010). Miniature eye movements measured simultaneously with ophthalmic imaging and a dual-Purkinje image eye tracker. Journal of Vision, 5(8), 590–590. https://doi.org/10.1167/5.8.590

Stevenson, S., Roorda, A., & Kumar, G. (2010). Eye tracking with the adaptive optics scanning laser ophthalmoscope. In S. Spencer (Ed.), Proceedings of the 2010 symposium on eye-tracking research and applications (pp. 195–198). New York, NY: Association for Computed Machinery.

Page 96: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

85

Sulai, Y. N., Scoles, D., Harvey, Z., & Dubra, A. (2014). Visualization of retinal vascular structure and perfusion with a nonconfocal adaptive optics scanning light ophthalmoscope. Journal of the Optical Society of America A, 31(3), 569. https://doi.org/10.1364/JOSAA.31.000569

Sunga, R. N., & Sloan, L. L. (1967). Pigmentary degeneration of the retina: early diagnosis and natural history. Investigative Ophthalmology, 6(3), 309–25. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/6027427

Talcott, K. E., Ratnam, K., Sundquist, S. M., Lucero, A. S., Lujan, B. J., Tao, W., … Duncan, J. L. (2011). Longitudinal Study of Cone Photoreceptors during Retinal Degeneration and in Response to Ciliary Neurotrophic Factor Treatment. Investigative Opthalmology & Visual Science, 52(5), 2219–2226. https://doi.org/10.1167/iovs.10-6479

Tu, J., Foote, K., Lujan, B., Ratnam, K., Qin, J., Gorin, M., … Roorda, A. (2017). Dysflective cone: visual function and cone reflectivity in long-term follow-up of acute bilateral foveolitis. American Journal of Ophthalmology Case Reports.

Tukey, J. (1949). Comparing individual means in the analysis of variance. Biometrics, 5(2), 99–114.

Tulunay-Keesey, U. (1960). Effects of involuntary eye movements on visual acuity. Journal of Optical Society of America, 50(8), 769–774.

Tulunay-Keesey, U. (1982). Fading of stabilized retinal images. Journal of Optical Society of America, 72(4), 440–447.

Tulunay-Keesey, U., & Jones, R. (1976). The effect of micromovements of the eye and exposure duration on contrast sensitivity. Vision Research, 16, 481–488.

Tuten, W. S., Tiruveedhula, P., & Roorda, A. (2012). Adaptive optics scanning laser ophthalmoscope-based microperimetry. Optometry and Vision Science : Official Publication of the American Academy of Optometry, 89(5), 563–74. https://doi.org/10.1097/OPX.0b013e3182512b98

van Meel, G. J., & van Norren, D. (1983). Foveal densitometry in retinitis pigmentosa. Investigative Ophthalmology & Visual Science, 24(8), 1123–30. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/6874276

Vanden Bosch, M. E., & Wall, M. (1997). Visual acuity scored by the letter-by-letter or probit methods has lower retest variability than the line assignment method. Eye (London, England), 11 ( Pt 3)(3), 411–7. https://doi.org/10.1038/eye.1997.87

Vislisel, J. M., Doyle, C. K., Johnson, C. A., & Wall, M. (2011). Variability of rarebit and standard perimetry sizes I and III in normals. Optometry and Vision Science , 88(5), 635–9. https://doi.org/10.1097/OPX.0b013e318211aa92

Vogel, C. R., Arathorn, D. W., Roorda, A., & Parker, A. (2006). Retinal motion estimation in

Page 97: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

86

adaptive optics scanning laser ophthalmoscopy. Optics Express, 14(2), 487–97. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/19503363

Wang, Q., Tuten, W. S., Lujan, B. J., Holland, J., Bernstein, P. S., Schwartz, S. D., … Roorda, A. (2015). Adaptive optics microperimetry and OCT images show preserved function and recovery of cone visibility in macular telangiectasia type 2 retinal lesions. Investigative Ophthalmology & Visual Science, 56(2), 778–786. https://doi.org/10.1167/iovs.14-15576

Watson, A. B., & Pelli, D. G. (1983). QUEST: A Bayesian adaptive psychometric method. Perception & Psychophysics, 33(2), 113–120. Retrieved from https://pdfs.semanticscholar.org/2635/cce2cce940f5d19465db8c5ab14b992515d4.pdf

Webb, R. H., Hughes, G. W., & Delori, F. C. (1987). Confocal scanning laser ophthalmoscope. Applied Optics, 26(8), 1492–9. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/20454349

Westheimer, G. (1987). Visual acuity and hyperacuity: resolution, localization, form. American Journal of Optometry and Physiological Optics, 64(8), 567–74. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/3661666

Westheimer, G. (2006). Specifying and controlling the optical image on the human retina. Progress in Retinal and Eye Research, 25(1), 19–42. https://doi.org/10.1016/j.preteyeres.2005.05.002

Westheimer, G., & McKee, S. P. (1977). Integration regions for visual hyperacuity. Vision Research, 17(1), 89–93. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/193277

Weymouth, F. W., Hines, D. C., Acres, L. H., Raaf, J. E., & Wheeler, M. C. (1928). Visual Acuity within the Area Centralis and its Relation to Eye Movements and Fixation. American Journal of Ophthalmology, 11(12), 947–960. https://doi.org/10.1016/S0002-9394(28)90119-1

Wilk, M. A., Dubis, A. M., Cooper, R. F., Summerfelt, P., Dubra, A., & Carroll, J. (2017). Assessing the spatial relationship between fixation and foveal specializations. Vision Research, 132, 53–61. https://doi.org/10.1016/j.visres.2016.05.001

Winter, S., Sabesan, R., Tiruveedhula, P., Privitera, C., Unsbo, P., Lundström, L., & Roorda, A. (2016). Transverse chromatic aberration across the visual field of the human eye. Journal of Vision, 16(14), 9. https://doi.org/10.1167/16.14.9

Winterson, B. J., & Collewijn, H. (1976). Microsaccades during finely guided visuomotor tasks. Vision Research, 16(12), 1387–90. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/1007017

Witkin, A. J., Ko, T. H., Fujimoto, J. G., Chan, A., Drexler, W., Schuman, J. S., … Duker, J. S.

Page 98: The effects of retinal image motion on the limits of ... · retinal image motion. Additionally, we investigated the purpose of fixational eye motion, and in particular microsaccades,

87

(2006). Ultra-high Resolution Optical Coherence Tomography Assessment of Photoreceptors in Retinitis Pigmentosa and Related Diseases. American Journal of Ophthalmology, 142(6), 945–952. https://doi.org/10.1016/j.ajo.2006.07.024

Wolfing, J. I., Chung, M., Carroll, J., Roorda, A., & Williams, D. R. (2006). High-resolution retinal imaging of cone-rod dystrophy. Ophthalmology, 113(6), 1019.e1. https://doi.org/10.1016/j.ophtha.2006.01.056

Wolkstein, M., Atkin, A., & Bodis-Wollner, I. (1980). Contrast sensitivity in retinal disease. Ophthalmology, (87), 1140–1149.

Yang, Q., Arathorn, D. W., Tiruveedhula, P., Vogel, C. R., & Roorda, A. (2010). Design of an integrated hardware interface for AOSLO image capture and cone-targeted stimulus delivery. Optics Express, 18(17), 17841. https://doi.org/10.1364/OE.18.017841

Yoon, G.-Y., & Williams, D. R. (2002). Visual performance after correcting the monochromatic and chromatic aberrations of the eye. Journal of the Optical Society of America. A, Optics, Image Science, and Vision, 19(2), 266–75. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/11822589

Yoon, M. K., Roorda, A., Zhang, Y., Nakanishi, C., Wong, L.-J. C., Zhang, Q., … Duncan, J. L. (2009). Adaptive optics scanning laser ophthalmoscopy images in a family with the mitochondrial DNA T8993C mutation. Investigative Ophthalmology & Visual Science, 50(4), 1838–47. https://doi.org/10.1167/iovs.08-2029

Zhang, Y., Poonja, S., & Roorda, A. (2006). MEMS-based adaptive optics scanning laser ophthalmoscopy. Optics Letters, 31(9), 1268–70. Retrieved from http://www.ncbi.nlm.nih.gov/pubmed/16642081