1 1192510-W2-B
CFI273E
Fitting Instructions
Iana 180Walk-in Enclosure
Kohler Daryl LimitedAlfred Road, Wallasey, Wirral, CH44 7HY England Tel 44 (0)844 571 0067 Fax 44 (0)844 571 7157
www.daryl-showers.co.uk E-mail [email protected]
Keeping your enclosure beautiful throughout its lifetime is easy withproducts from the Daryl care programme
The Daryl Care Programme
Using state of the art bespoke machinery combined with the latest technology, all Daryl doors and panels are coated with a glass protector in highly controlled factory conditions.The protector acts as an invisible barrier on the glass toprevent build up of limescale, soap scum, stains and dirt.The factory applied protector will last from months to years depending on use and the hardness of water in your area.It will never crack, peel, discolour or build up. Coated surfaces are kept clean simply by rinsing or wiping with a damp cloth and regular use of Daryl Glass Cleaner.
There are two separate elements to caring for your Darylshower door, enclosure or bath screen.
1 Daryl Glass Cleaner for the regular cleaning of your shower door, enclosure or screen
2 Daryl Care Kit comprising of Glass Treatment and Glass Protector suitable for use where glass protector has not already been applied or for topping up factory coated protector
Daryl Glass Cleaner
For occasional cleaning of glass treated with Daryl GlassProtector or for more regular maintenance of untreatedsurfaces, we recommend using Daryl Glass Cleaner. TheCleaner cleans and polishes without smearing or streak-ing and rejuvenates the Glass Protector.
Daryl Glass Treatment and Daryl Glass Protector
Available in one care kit, the Treatment and Protector areused on new or existing shower installations where Protector has not already been applied and for topping up factory coated glass after a reasonable length of time. The Treatment must always be used on existing shower installations to prepare for the Protector. The Treatment is a cleaning material that is applied to the glass to ensure it is in the cleanest condition possible prior to application of the Protector. If this process is not under-taken, there is the likelihood of locking in dust, dirt and stains under the Protector.
Daryl Protector acts as an invisible barrier on the glass toprevent the build up of lime scale, soap scum, stains and dirt. Applied like a polish, one application will last from months to years depending on use and the hardness of water in your area. It will never crack, peel, discolour or build up. Coated surfaces are kept clean simply by rinsing or wiping with a damp cloth and regular use of Daryl Glass Cleaner.
Regular cleaning
• Mildew thrives in damp, unventilated areas. It is, therefore, important to always wipe down, with a soft cloth or towel, the glass and metal sections inside the shower every time it is used
• Do not allow water to remain on glass and metal sections for long periods of time
• Every week or two, use Daryl Glass Cleaner to polish the enclosure (including metal sections) ensuring all surfaces are wiped down
• In hard water areas, do not allow lime scale to build up.Stubborn deposits of lime scale can usually be removedby using a 50:50 solution of vinegar and water, whichshould be rinsed off thoroughly and dried after use
• Regular cleaning is required to remove the smallamounts of residue that are not repelled by the Protector
Everyday CareWipe down the glass and metal sections with a soft cloth or towel and warm water after each time the shower is used.Do not allow water to remain on glass and metal sections for long periods, do not allow the build up of lime scale and do not use caustic cleaners or abrasives.
Daryl showers traysIf you have a Daryl shower tray scuffs and marks on acrylic trays can often be removed by the light use of a mildly abrasive cleaner applied with a damp cloth and polished off.
Other cleaning materials
Ensure that if you use a non-Daryl cleaning product, it has a pH level between 4 & 8 and is non-abrasive. Prolonged use of cleaners with a pH level outside the specified range can cause damage to metal sections and possibly affect the safe operation of your Daryl Shower. All cleaning material (including Daryl’s) must be wiped down after application.Do not use ‘spray and leave’ cleaning products on the metal surface as these may cause damage to your door or enclosure.
These instructions must be left with the user
Installation Guide
Skyline Walk-In Enclosure
21192510-W2-B
Safety Information1. Careshouldbetakenwhendrillingintowallsandfloorstoavoidanyhiddenpipesor
wires.2. Westronglyrecommendthatallglasspanelsaremovedbyaminimumoftwopeople
andthatanyprotectivepackagingalongtheglassedgesiskeptinplaceforaslongaspossibletopreventdamagebeforeinstallation.
3. Duringinstallationwerecommendadditionalhelpinliftingheavydoorsandsidepanels.4. Wearprotectivefootwearwhenliftingpanels.5. Wear safety glasses when drilling.
Wall Preparation
GENERAL INFORMATION
The wa l l channe ls must be installed onto a tiled or waterproof finished flat andevenwallsurface.Failuretodoso will result in an unsatisfactory seal,whichmaycausepropertydamage.
INTRODUCTIONThankyouforpurchasingaqualityKOHLER®product.Toenjoythefullpotentialofyournewproduct,pleasetaketimetoreadthisguidethoroughly,havingdoneso,keepithandyforfuture reference.Thefollowingpagesaimtoprovidecomprehensiveinstallationinstructions,plusadviceonhowtocareandmaintainyourproduct.Werecommendthattheunitisinstalledbyaqualifiedplumberorengineer.
General1. Readalloftheseinstructionsandretainthisguideforlateruse.2. Passonthisguideintheeventofchangeofownershipoftheinstallationsite.3. Followallwarnings,cautionsandinstructionscontainedinthisguide.4. Removeallprotectivetapefromtheenclosurebeforeinstallation.
3 1192510-W2-B
GUARANTEEFordomestic installations,yourenclosurehasthebenefitofourlifetimeguaranteewhichstartsfromdateofpurchase.
Fornon-domestic installations,weguaranteetheproductagainstanydefectinmaterialsorworkmanshipforaperiodofoneyearfromthedateofpurchase.
Fortermsandconditionsrefertothebackcoverofthisguide.
RecommendedUsageDomestic ü
LightCommercial ü
HeavyCommercial û
Healthcare û
41192510-W2-B
Components
CFI273E 3
x10
A
x6
B
x1
C
x10
x2
2.5mm
3mm
STEP23
STEP25
STEP24
10 CFI273E
With the panel vertical and the towel railhorizontal, mark the position of the wall mount on
the wall.
Push the towel rail into the wall mount and re-fitthe towel rail to the glass (see Step 22).
Remove the towel rail and remove the wall mount.Place on the wall as marked. Mark the fixing
hole on the wall.
STEP22
Fit the towel rail to the glass panel.
Note:Towel rail can be fitted
inside or outsideof the enclosure
6mm
Drill a 6mm holein the wall.
Fit plug.
A
Secure thewall mount.
Adjust the glass panel so that it is vertical.Tighten the grub screw to secure the towel rail.
Note:An HSS 10mm drill bit
is required for thisinstallation
x5
1700 Top Cap
1400 Top CapFiller Cap Side Panel Top Cap
RH Lintel GlassMounting Block LH Lintel Glass
Mounting Block
Lintel
Lintel WallMount
Towel Rail
Towel RailWall MountMounting Block
Wall Channel
Side Panel
CornerGasket
Curved GlassPanel
Wall Channel
AllenGrub Screws
SlottedGrub Screw
PACK CONTENTS
5 1192510-W2-B
INSTALLATION
x3
x3
6mm
x3
x3
A
Fitting InstructionsThe tray should be fitted and the walls tiled
before installation of the enclosure.Mark the position of the wall channelfrom the wall tiles on the back wall.
STEP1
STEP2
STEP4
STEP3
4 CFI273E
Back edgeof wallchannel
Wall channelMUST bevertical on
the front face.
Fit the curved panel wall channel to the wall.
Place the glass mounting block into the tray.IMPORTANT
Do not remove the adhesive backing from the underside of the mounting block at this stage.
Carefully lift the glass into place. The jamb fitsonto the wall channel and the bottom corner of the
glass fits into the mounting block (see Step 5).
STEP19
STEP21
STEP20
9CFI273E
Carefully lift the side panel into position,uncoated side to the outside.
Ensure the glass panel is vertical.Carefully slide the jamb onto the wall channel.
STEP18
Remove the backing paper from the mounting block.
Fit the mounting block to the tray.Note: The slot for the glass should face the wall
channel. Place a blob of sealant into the mounting block.
Backingpaper
At the other end, place the glass into the mountingblock.
B
Drill 3 x 3mm holes through the wall channel into the jamb.
Secure glass panel with3 x screw B.
NOTE:LH VERSION
SHOWN. RH FITTING
MIRRORS THEINSTALLATION
SHOWN.745mm (1400 tray)640mm (1700 tray)
(adjust the dimension if other than
10mm tile thickness)
61192510-W2-B
x4
x4
6mm
x4
x4
21.5mm
STEP15
STEP17
STEP16
8 CFI273E
If any adjustment is required, move the lintelin or out until the glass is vertical.Ensure the glass is vertical
and and the lintel is horizontal.
When the glass and lintel are in the correct positiontighten the grub screws at both ends.
Fit the side panel wall channel to the wall
Carefully slide the jamb onto the wall channel.
STEP5
STEP7
STEP6
5CFI273E
Place the corner of the glass into the mounting block.
Adjust the glass until it is vertical and equallyspaced around the lip of the tray.
Carefully remove the curved panel from the tray.Remove the mounting block.
Remove the backing paper from the mounting block.
Wall channelJamb
Mark the position of the mounting block on the tray.
Fit the mounting block to the marks on the tray.Place a blob of sealant into the mounting block.
Backingpaper
=
A
Drill a 10mmhole in the tray.
Mark a point 53mm back from thefront face of the tray, on the centre line
of the raised portion
53mm
7 1192510-W2-B
Carefully lift the curved panel back into place andcheck that the glass is vertical and equally spaced
around the lip of the tray.
STEP9
STEP11
STEP10
6 CFI273E
Drill 3 x 3mm holes through the jamb into thewall channel.
STEP8
Secure the jamb to wall channel with3 x screw B.
B
Place the lintel on top of the glass.
STEP12
STEP14
STEP13
7CFI273E
Fit the corner glass gasket to the glass then placethe lintel glass mounting block on top.
Remove the lintel. Take the wall mount o� the linteland place on the wall as marked.
Fit the lintel to the wall mount.
Ensure the glass is vertical and and the lintel is horizontal.
When the lintel is horizontal and the inner edge of thewall mount is against the mark, draw around the
wall mount.
Mark the position of the two�xing holes on the wall
A
Fit the mounting block to the glass and lockin place by turning screw ‘A’.
A
Drill 2 x 6mm holes. Fit plugs.
Secure thewall mount with
2 x screw A.
Mark the �xing point for the lintel on the wallat the height of the top of the glass.
Loosely �t the parts of the lintel together.
Note: the lintel end with a straight sectiongoes towards the wall.
984mm (1400 tray)1240mm (1700 tray)
(adjust the dimension if otherthan 10mm tile thickness)
81192510-W2-B
Carefully lift the curved panel back into place andcheck that the glass is vertical and equally spaced
around the lip of the tray.
STEP9
STEP11
STEP10
6 CFI273E
Drill 3 x 3mm holes through the jamb into thewall channel.
STEP8
Secure the jamb to wall channel with3 x screw B.
B
Place the lintel on top of the glass.
STEP12
STEP14
STEP13
7CFI273E
Fit the corner glass gasket to the glass then placethe lintel glass mounting block on top.
Remove the lintel. Take the wall mount o� the linteland place on the wall as marked.
Fit the lintel to the wall mount.
Ensure the glass is vertical and and the lintel is horizontal.
When the lintel is horizontal and the inner edge of thewall mount is against the mark, draw around the
wall mount.
Mark the position of the two�xing holes on the wall
A
Fit the mounting block to the glass and lockin place by turning screw ‘A’.
A
Drill 2 x 6mm holes. Fit plugs.
Secure thewall mount with
2 x screw A.
Mark the �xing point for the lintel on the wallat the height of the top of the glass.
Loosely �t the parts of the lintel together.
Note: the lintel end with a straight sectiongoes towards the wall.
984mm (1400 tray)1240mm (1700 tray)
(adjust the dimension if otherthan 10mm tile thickness)
9 1192510-W2-B
x4
x4
6mm
x4
x4
21.5mm
STEP15
STEP17
STEP16
8 CFI273E
If any adjustment is required, move the lintelin or out until the glass is vertical.Ensure the glass is vertical
and and the lintel is horizontal.
When the glass and lintel are in the correct positiontighten the grub screws at both ends.
Fit the side panel wall channel to the wall
Carefully slide the jamb onto the wall channel.
STEP5
STEP7
STEP6
5CFI273E
Place the corner of the glass into the mounting block.
Adjust the glass until it is vertical and equallyspaced around the lip of the tray.
Carefully remove the curved panel from the tray.Remove the mounting block.
Remove the backing paper from the mounting block.
Wall channelJamb
Mark the position of the mounting block on the tray.
Fit the mounting block to the marks on the tray.Place a blob of sealant into the mounting block.
Backingpaper
=
A
Drill a 10mmhole in the tray.
Mark a point 53mm back from thefront face of the tray, on the centre line
of the raised portion
53mm
101192510-W2-B
x3
x3
6mm
x3
x3
A
Fitting InstructionsThe tray should be fitted and the walls tiled
before installation of the enclosure.Mark the position of the wall channelfrom the wall tiles on the back wall.
STEP1
STEP2
STEP4
STEP3
4 CFI273E
Back edgeof wallchannel
Wall channelMUST bevertical on
the front face.
Fit the curved panel wall channel to the wall.
Place the glass mounting block into the tray.IMPORTANT
Do not remove the adhesive backing from the underside of the mounting block at this stage.
Carefully lift the glass into place. The jamb fitsonto the wall channel and the bottom corner of the
glass fits into the mounting block (see Step 5).
STEP19
STEP21
STEP20
9CFI273E
Carefully lift the side panel into position,uncoated side to the outside.
Ensure the glass panel is vertical.Carefully slide the jamb onto the wall channel.
STEP18
Remove the backing paper from the mounting block.
Fit the mounting block to the tray.Note: The slot for the glass should face the wall
channel. Place a blob of sealant into the mounting block.
Backingpaper
At the other end, place the glass into the mountingblock.
B
Drill 3 x 3mm holes through the wall channel into the jamb.
Secure glass panel with3 x screw B.
NOTE:LH VERSION
SHOWN. RH FITTING
MIRRORS THEINSTALLATION
SHOWN.745mm (1400 tray)640mm (1700 tray)
(adjust the dimension if other than
10mm tile thickness)
11 1192510-W2-B
Components
CFI273E 3
x10
A
x6
B
x1
C
x10
x2
2.5mm
3mm
STEP23
STEP25
STEP24
10 CFI273E
With the panel vertical and the towel railhorizontal, mark the position of the wall mount on
the wall.
Push the towel rail into the wall mount and re-fitthe towel rail to the glass (see Step 22).
Remove the towel rail and remove the wall mount.Place on the wall as marked. Mark the fixing
hole on the wall.
STEP22
Fit the towel rail to the glass panel.
Note:Towel rail can be fitted
inside or outsideof the enclosure
6mm
Drill a 6mm holein the wall.
Fit plug.
A
Secure thewall mount.
Adjust the glass panel so that it is vertical.Tighten the grub screw to secure the towel rail.
Note:An HSS 10mm drill bit
is required for thisinstallation
x5
1700 Top Cap
1400 Top CapFiller Cap Side Panel Top Cap
RH Lintel GlassMounting Block LH Lintel Glass
Mounting Block
Lintel
Lintel WallMount
Towel Rail
Towel RailWall MountMounting Block
Wall Channel
Side Panel
CornerGasket
Curved GlassPanel
Wall Channel
AllenGrub Screws
SlottedGrub Screw
121192510-W2-B
Seal between the wall channel and the wall onboth sides.
Seal around the base of the panel wall channel and along the bottom of the glass.
CFI273E2
C
Fit the top caps to both sides.
STEP27
STEP29
STEP28
11CFI273E
STEP26
Fit the cover strips on both sides.
24hrs
Do not use the enclosure forat least 24 hours.
IntroductionThe following pages aim to provide comprehensive installation instructions, plus advice on how to care and maintain your product.We recommend that the unit is installed by a qualified Plumber or Engineer.Please retain this document for future reference.Note: Due to our desire to always improve our products, Daryl reserve the right to change specification without prior notice.
Safety PrecautionsCaution: Care should be taken when drilling into walls and floors to avoid any hidden pipes or wires.We strongly recommend that all glass panels are moved by a minimum of two people and that any protective packaging along the glass edges is kept in place for as long as possible to prevent damage before installation.
Wear protectivefootwear whenlifting panels
Wear safetyglasses whendrilling
Care & MaintenanceThe unit should be wiped down immediately after each use. Use a non abrasive cleaner with a pH value between4 & 8, applied with a soft cloth. A 50:50 solution ofvinegar & water can be used on lime scale deposits,rinsing off thoroughly after use. Do not use alkalissuch as caustic soda.Under no circumstances should scourers or powerful detegents be used as these can damage the metallic surface of the frame and the surface ofthe tray or bath, and also tarnish the glass coating.If fitted correctly the unit should not require any maintenance other than cleaning. If problems dooccur contact the Daryl Technical Helpline Tel: 0844 571 0067
People not familiar with the fitting of Daryl Products may requirethe assistance from another person at certain stages of the procedure. We have indicated these points in the process with the Caution Symbol. Caution
Made in the UK by: Kohler Daryl LimitedAlfred Road, Wallasey, Wirral, CH44 7HY England
Tel 44 (0)844 571 0067 Fax 44 (0)844 571 7157
13 1192510-W2-B
MAINTENANCEGeneral MaintenanceProviding the shower enclosure hasbeen correctly installed and is operated inaccordancewiththeinstructionscontainedinthisguide,difficultiesshouldnotarise.
Ifanymaintenanceisrequiredthenitmustbecarriedoutbyacompetenttradespersontowhomthemaintenanceinstructionsareprovided.
Beforereplacinganypartsensuretheunderlyingcauseofthemalfunctionhasbeenresolved.
CleaningWarning!Manyhouseholdcleanerscontainabrasiveandchemicalsubstancesandshouldnotbeusedforcleaningpainted,platedorplasticfittings.Thesefinishesshouldbecleanedwithamildwashingupdetergentorsoapsolutionandthenwipeddryusingasoftcloth.
CareTopreservethebeautyofyourshowerenclosureformanyyears,pleaseobservethe following care instructions:
Rinseglassand framewithclearwateraftershowering.Removewaterdropletswithasqueegee.Donotrubdry!Tocleanyourshowerhygienicallyandeasily,werecommend the use of a biodegradable cleanser.
Regular cleansingwith a biodegradable cleanser prevents stubborn stains andensures a clean and hygienic surface for many years. Do not use scouring or caustic cleansersunderanycircumstances!Thesecandamagethesurfaceoftheframe,glassanddecorativepartsaswellastheplasticparts.
Chrome PartsUseonlycleansersexpresslyspecifiedforchrome!
141192510-W2-B
NOTES
15 1192510-W2-B
161192510-W2-B ©KohlerCo.March2013
0044 844 571 0048
Kohler Mira LimitedCustomer Services Dept,1 Penrose Place,Skelmersdale,WN8 9PR
To Contact Us: UK
Fax: 0044 844 571 7157
CUSTOMER SERVICE
E-mail: [email protected]
To Contact Us: Eire Only
0844 571 0048
Fax: 0844 571 7157
Helpdesk ServiceOur Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit.
We will need you to have your model name, model number and date of purchase.
KOHLER® Website (www.KOHLER.co.uk)From our website you can download additional user guides or request a service visit.
Spares and AccessoriesWe hold the largest stocks of genuine Kohler spares and accessories.Contact us for a price and to purchase spares or accessories.
Service / RepairsNo one knows our products better than our nationwide team of Service Technicians. We can carry out service or repair work to your product both during and after the guarantee period.
Ask about our fi xed price service repairs.
GuaranteeYour enclosure has the benefi t of our lifetime guarantee which starts from the date of purchase.To activate this guarantee, you must return your completed registration card with a copy of proof of purchase from an approved Kohler retailer within 30 days of purchase.This guarantee is in addition to your statutory rights and is subject to conditions (see registration card).
What to do if something goes wrongIf your product does not function correctly when you fi rst use it, contact your installer to check that it is installed in accordance with the instructions in this manual.
If this does not resolve the issue, contact our Customer Services Team who will offer you or your installer help and advice.
Kohler Mira Limited, Cromwell Road, Cheltenham,Gloucestershire, GL52 5EP, UK
13EN 14428:2004 + A1: 2008
By Post:
Kohler is a registered trade mark.The company reserves the right to alter product specifi cations without notice.
(210)