Contents
• Introduction
• Compact fluorescent lamps
• Halogen lamps
• Fluorescent tubes
• High intensity discharge lamps
• Electronic control gear
• LED systems
• Questions
z
zz
z z
zz
z
z
zz
z
z
zz
z
No environmental awareness without economic benefits
Climate Change and Global Warming Not a new topic, but now with the right attention !
The relevance of lighting on a global scale
• Lighting accounts for 19% of global
electricity consumption and is
responsible for emissions of 1,325 millions tons of CO2
• 2,651 TWh were used for lighting in 2005 ~ the electricity consumption of the EU
• Over 1/3 of this electricity could be saved
with more efficient technology - leading
to savings of more than 450 million tons of CO2
Global Electricity
Consumption
19%
81%
Other electrical use Lighting
Focus on efficient products
“Energy efficient products
already account for 60% of
sales at OSRAM, and we
intend to increase this to
80% over the next 10 years.”
OSRAM CEO Martin Goetzeler
Technology Shift
Valu
e
2005 2015
Fluorescent
LED
HID
CFL
Halogen
GLS
2 for typical usage / Energy-Mix 0,5 kg CO2/kWh 3 one tree can absorb 20kg CO2/year4 Average energy cost: 0,15€/kWh
Energy saving through innovative lamp technologies
Street lighting
Office and industry lighting
Shop lighting
Hospitality spotlighting
Residential lighting
Application in general lighting
FL with halophos-
phate phosphor
(4x18W) + CCG
Halogen lamp
(3x50W)
Incandescent
(60W)
Mercury vapour
(125 W)
Dichroic halogen
reflector lamp
(50W)
~30%
~30%
~80%
~70%
~45%
Ceramic metal halide
lamp POWERBALL
HCI®-T (1x35W)1
Compact fluorescent
lamp OSRAM DULUX®
EL LONGLIFE (11W)
LUMILUX® T5 (3x14W)1
+ ECG QTi DALI® +
LMS DALI® MULTI 3
Halogen lamp
HALOGEN ENERGY
SAVER (42W)
DECOSTAR® ENERGY
SAVER (35W) with
IRC technology
~savings per lamp / year2
(hours burnded)
250 kWh /125 kg CO2(4000 h)
210 kWh /105 kg CO2(4000 h)
500 kWh /250 kg CO2(4000 h)
60 kWh /30 kg CO2(4000 h)
18 kWh /9 kg CO2(1000 h)
CO2 savings per year as tree index3
0.5
1.5
12.5
5.3
6.3
Lighting design Dichroic halogen
Reflector lamp
(20W)
~50%LED lamp COINlight-
OSTAR® (12W)1
45 kWh /22 kg CO2(4000 h)
1.2
Incandescent
(60W)
~80%50 kWh /25 kg CO2(1000 h)
Double win with efficient products:Environmental benefit > less CO2 emissionsDouble win with efficient products:User benefit > savings in energy costs
1.3
~savings in energy costs 100 lamps per year4
€ 3,750
€ 3,150
€ 5,250
€ 900
€ 270
€ 675
€ 750
Ceramic metal halide
lamp POWERBALL
HCI®-TT (70W)1
1 1:1 replacement not possible
Phase out proposal of lighting industry working groupsof the ELC
Street-lighting
SLIM
Street-lighting
SLIM
Office/Industry light.
OIL
Domestic lighting
DIM
Group
allStandard HPS-lamps
all Standard
HPM-lamps
allBasic Fluorescent
all
others60W
75W,
100W> 100W
Incandescent
lamps
2015201420132012201120102009ProductGroup
maybe earlier
Steps to save energy and reduce maintenance costs
Single / Groupreplacement
LampTechnology
DaylightHarvesting
PresenceControl
NewLuminaires
ECGTechnology
User investment levels
OSRAM DULUX® L 28W HE
Optimised for 600mm modular luminaires
• New 2Gx11 base
• 3000 and 4000K
• 2800 lm
� Lumen package equivalent to 2 x HE 14W T5
(and 34W L type)
� 100 lm/W
� 20,000 hours average life
� Cost saving for OEM (less bases and construction)
� New energy efficient luminaire designs possible
� Offices, public buildings, supermarkets
OSRAM DULUX® CONSTANT
Excellent temperature management
• 40W, 55W, and 80W L type
• 57W, 70W and 120W T/E type
>90% luminous flux from +5 to +70°C
(standard Dulux L >90% luminous flux +20 to
+40°C)
� Up to 20,000 hours life
� “Hot” compact luminaires
� Outdoor lighting
� Cold storage areas
OSRAM DULUX® T/E 14 and 17W HE
Energy saving in new luminaires
• New GR14q-1 twist and lock base
• 3000K and 4000K
• Shorter length
� Up to 20% energy savings
� High efficacy – 75/74 lm/W
� 20,000 hours average life
� New energy efficient luminaire designs
possible
� Offices, public buildings, supermarkets
OSRAM DULUX® D Energy Saver
Energy savings in existing luminaires
• Direct replacement of DULUX D lamps
• 18W > 16W
• 26W > 23W
• 10% reduction in power consumption
� Energy saving in existing CCG
installations
HALOGEN ENERGY SAVER or CFLi?
Halogen upsell
Replacement
GLSGLS
Halogen Standard
Halogen Standard
HALOGEN ENERGY SAVER 240V
30% energy savings & natural light
HALOGEN ENERGY SAVER 12V
30% energy savings & natural light
CFLi
80% energy savings
Low voltage Halogen Energy Savers
• 1:1 replacement of 12V halogen
• Up to 30% energy savings
• 5000 hrs average life
• Constant bright light
• Dimmable
� Ideal for professional applications
20(35), 35(50), 50(65)DECOSTAR® ES
14(20), 25(35), 35(50), 50(75), 65(90)HALOSTAR® ES
35(50), 50(75), 65(100)HALOSPOT® 111 ES
HALOGEN ES Wattage (replaced wattage)HES type
Mains Voltage Halogen Energy Savers
• 1:1 replacement of incandescent and halogen
• Up to 30% energy savings
• 2000 hrs average life
• Constant bright light
• Dimmable
• No mercury
� Ideal for residential and commercial lighting
48(60), 80(100), 120(150), 160(200), 230(300), 400(500)HALOLOINE®
28(35), 40(50)HALOPAR® 16
33(40)HALOPIN® G9
42(60)Spot R63
28(40)Spot R50
18(25), 28(40), 42(60)Candle
18(25), 28(40), 42(60), 52(75), 70(100), 105(150)GLS
HALOGEN ES Wattage (replaced wattage)HES type
LUMILUX® T5 HO XT (X-tended T-rust)
Long life T5 fluorescent tube
54W and 80W
3000K, 4000K and 6500K
� 50,000 hours average life
� Reduced maintenance costs
� Less disruption to installation
� Reduced waste and disposal costs
� Industry, tunnels, any area that is difficult
to access
LUMILUX® T5 HO CONSTANT
Excellent temperature management
24W, 39W, 54W and 80W
>90% luminous flux from +5 to +70°C
(standard T5 >90% luminous flux +25 to
+50°C)
� Up to 24,000 hours life
� “Hot” compact luminaires
� Outdoor lighting
� Cold storage areas
LUMILUX® T8 Energy Saver
Energy saving T8 replacement
36W > 32W
58W > 51W
3000K, 4000K and 6500K
� Up to 10% energy saving on CCG
� Replacement of BASIC tubes in CCG
installations
� 13,000 hours average life
LUMILUX® T8 XXT (Extra X-tended T-rust)
Long life T8 fluorescent tube
18W, 36W and 58W
3000K, 4000K and 6500K
� 90,000 hours average life (T8 XT 50,000hrs)
� Reduced maintenance costs
� Less disruption to installation
� Reduced waste and disposal costs
� Retail stores, production areas,
warehouses, transportation, any area
that is difficult to access
Calculators on www.osram.com
Prove the savings
Comparison of annual savings:
LUMILUX T8
LUMILUX XT T8
LUMILUX XXT T8
www.osram.com/saver-calculator-t8
The full OSRAM range for your complete success
HCI®-T/ HCI®-TC
Shoplight
HCI®-TC
HCI®-T
HCI®-TF
HCI®-T/P
HCI®-T 250 W
HCI®-E
HCI®-E/P HCI®-TT
HCI®-TS
HCI®-R111
HCI®-PAR
PTi I
PTi S
POWERBALL HCI® technology
The revolutionary round ceramic arc tube offers unique benefits:
� Better colour rendering
� Higher luminous flux
� Improved colour stability
� Better lumen maintenance
� Faster run-up to full output
� Longer life
POWERBALL® HCI® -T Shoplight
Perfect solution for retail environments
• 35W and 70W
• WDL
� Improved red rendering
� Colour 930 (standard T 830)
� Upgrade existing installations
� High quality presentation of merchandise
� Retail, decorative and exterior installations
OSRAM Electronic Control Gear
Systematic steps to energy saving
• DALI and 1-10V DIM
• Fixed output: T5, T8, CFL
� High reliability of your lighting system
� System guarantee
� More than 100,000,000 OSRAM ECGs
registered in all sectors
� QUICKTRONIC® PROFESSIONAL T8
now guaranteed for 8 years
QUICKTRONIC® PROFESSIONAL T8
Industrial strength ECG
• Operates all T8 lamps
• Can be used with NEW XXT and XT lamps
� 100,000 hours lifetime at maximum case
temperature of 70°C
� Perfect for industrial applications, airports,
hospitals, supermarkets
QUICKTRONIC® PROFESSIONAL T5
Ideal partner for T5 products
• Operates all T5 lamps
• Can be used with NEW XT HO T5 and 28W
HE
� 50,000 hours lifetime at maximum case
temperature
� Cut-off technology
� Compact luminaires
� Perfect for industrial applications, airports,
hospitals, supermarkets
QUICKTRONIC® INTELLIGENT
The versatile ECG
• Operates T5, T8 and CFL lamps
• DALI or 1...10V dimmable versions
� Intelligent lamp detection
� Flexible use of lamp systems
� Reduced manufacturing complexity
� Perfect for industrial applications,
airports,
Solar Protection
HVAC
Security
Networking
Lighting Control
Lighting Management
System
Building Control
Components
Stand-alone devices,
simple control
Energy
Systems for
improvement of
efficiency &
sustainability
Comfort
To achieve the requested
light situation in an easy
comfortable way
ON / OFF
switches
Timer
Light management systems
System guarantee
The system guarantee from OSRAM: systematic quality from a single source
• Electronic control gear from OSRAM achieves its optimum functionality
when operating as a system in conjunction with innovative lamps from
OSRAM
• OSRAM lamps and OSRAM ECGs are perfectly matched to one another
• Extensive guarantee for ECGs and ECG/lamp systems from OSRAM
• Details of relevant products, systems, registrations and conditions are
at www.osram.com/system-guarantee
OSRAM solid state segmentation
OS discrete LED
Chip Package
LUMFixtures
Luminaires
General Lighting:
Automotive:
Special:
Custom Design:
Luminaires:
Illumination, Decoration, Signage, Channel Letter,
Architectural Lighting and Retrofits
Front Lighting, Rear Combination Lighting
Display Lighting, Entertainment, Medical, Industrial
Customised LED Systems
LED Light Engines
LS LED System solutions
BoardHeat
sinkOptics Driver Control
software
Power
SupplyRetrofit
GaAsP-Red
Hyper-Red
Super Red
Amber
Orange
Yellow
Yellow Green
Pure Green
True Green
Verde Green
Blue
White
Average lifetime
under normal operating conditions
The OSRAM definition for the life of an LED is:
An LED has come to
the end of its life when
the luminous flux is
only 50 % of the value
measured at the start
of its life.
LED lifetimes
50,000 – 75,000 hrs
125,000 hrs
250,000 hrs
150,000 hrs
Impacts on lifetime
� Good cooling� More light
� Longer lifetime
Cold
� Higher Current� More light
� Shorter lifetime
Current
� More heat� Less light
� Shorter lifetime
Heat
Adjusting the Temperature=
Affects the Lifetime
Temperature
Current
Brightness