26
The 2009 Deployment Tour Matthew Newcomb

The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Embed Size (px)

Citation preview

Page 1: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

The 2009 Deployment Tour

Matthew Newcomb

Page 2: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

The hole shrinks by 15 cm on the diameter every 24 hours

A DOM requires at least 45 cm on the diameter or it will get stuck

One string costs ~ 1 million dollars

You guessed it! Getting a string stuck is BAD!

Page 3: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Before You Start:

How much time do you have to deploy a string?

Introducing lifetime: lifetime is the number of hours from the time the drill leaves the hole to the time that the any point on the hole reaches the minimum 45 cm.

Okay, so how do I know the lifetime of a hole?

Introducing hole lifetime modeling: See http://driller.icecube.wisc.edu/

Page 4: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 5: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Is this enough?

It's a start, you should look at all of the drill data.

What is available?

Drill CalipersFlow RatesWater Temperature

Page 6: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

What Tools Do We Have To Measure The Hole?

Drill Head Calipers

Page 7: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 8: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 9: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

What Do You Think Of This Hole?

Page 10: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 11: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 12: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 13: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

How Do You Know When The Drill Is Out Of The Hole?

Quasi-Real Time Data Available On The Web

Page 14: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Setting Up:

The user interfaces and controller software must be started in deployment mode. If unsure, and drilling is finished, close both user interfaces and the drill control software. Then start the deployment version of both.

Cabling:

Connect DDB cable to the deployment reel and to the DDB.

Unico drives must be in deployment mode. They will automatically go into this mode when the deployment reel is connected

Page 15: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

What Does A String Look Like?

500 lbs

Paro

Keller

Load Cell

Note: Drawing Not To Scale

PayoutSensor

Page 16: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Paro? Keller? What's That?

Keller

Paro

Two Different Pressure Sensors? Why? $$$ Paro $7K, Keller $700

Page 17: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Keller:

It's a 4-20mA current source that is proportional to the pressure applied to it. That proportion changes depending on the keller. You MUST tell the computer the keller's serial number.

Page 18: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

If you have the pressure at some point in the hole you can getthe depth. A rough value:

depth in inches = (pressure sensor value in PSI * 27.68) - (ambientpressure in mBar * 0.535 * 27.68 )

Note the ambient pressure! Double check the ambient air pressure!

Pressure Equals Depth

Page 19: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 20: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

What are these?

Page 21: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Does everything always work right?

Page 22: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 23: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

What do you do if one sensor reads an unexpected value?

What do you do if more than one sensor reads an unexpected value?

Discussion

Page 24: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

How long does deployment take?

Page 25: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it
Page 26: The 2009 Deployment Tour Matthew Newcomb. The hole shrinks by 15 cm on the diameter every 24 hours A DOM requires at least 45 cm on the diameter or it

Closing:

All of the data from last year is available on the web:http://driller.icecube.wisc.edu/media/history/2008-2009/index.html

Look at them. If you have questions, or what to know somethingnot covered here. Email me:

[email protected]