4
THE GTD™ GENERATOR TRANSFER DEVICE AND GTD20™ SWITCH BYPASS DEVICE OFFER ENERGY-SAVING TECHNOLOGY FOR GENERATOR- OR CENTRAL INVERTER SYSTEM- SUPPLIED EMERGENCY LIGHTING. © 2004 THE BODINE COMPANY 04.2 20A Dual Input 120/277V Fluorescent, Incandescent and HID On wall or in ceiling 9” L x 6” W x 3.5” H 4.5 lbs. (2.0 kg) Current Rating Operating Voltage Lighting Load Mounting Size Weight 3A Dual Input 120/277V Fluorescent Inside most luminaires 8” L x 1.18” W x 1.18” H .5 lbs. (.2 kg) GTD GTD20 GTD& GTD20P.O. Box 460 Collierville, TN USA 38027-0460 www.bodine.com Sales 800.223.5728 Fax 901.853.5009 Tech Support 888.263.4638 See page 2 of this newsletter for more product information on the GTD and GTD20.

THE 04 - Bodinebodine.com/downloads/news/Vision04-02.pdf04.2 product news q&a ... gen series interim lighting backup ballasts for use with standby generator systems tran-bal

Embed Size (px)

Citation preview

Page 1: THE 04 - Bodinebodine.com/downloads/news/Vision04-02.pdf04.2 product news q&a ... gen series interim lighting backup ballasts for use with standby generator systems tran-bal

THE GTD™ GENERATOR TRANSFER DEVICE AND GTD20™ SWITCH BYPASS DEVICE OFFER ENERGY-SAVING TECHNOLOGY FOR GENERATOR- OR CENTRAL INVERTER SYSTEM-SUPPLIED EMERGENCY LIGHTING.

© 2004 TH

E BOD

INE C

OM

PAN

Y

04.2

20A

Dual Input 120/277V

Fluorescent, Incandescent and HID

On wall or in ceiling

9” L x 6” W x 3.5” H

4.5 lbs. (2.0 kg)

Current Rating

Operating Voltage

Lighting Load

Mounting

Size

Weight

3A

Dual Input 120/277V

Fluorescent

Inside most luminaires

8” L x 1.18” W x 1.18” H

.5 lbs. (.2 kg)

GTD GTD20GTD™ & GTD20™

P.O. Box 460 Collierville, TN USA 38027-0460 www.bodine.com Sales 800.223.5728 Fax 901.853.5009 Tech Support 888.263.4638

See page 2 of this newsletter for more product information on the GTD and GTD20.

Page 2: THE 04 - Bodinebodine.com/downloads/news/Vision04-02.pdf04.2 product news q&a ... gen series interim lighting backup ballasts for use with standby generator systems tran-bal

GTD™ & GTD20™

THE B

OD

INE CO

MPA

NY, IN

C. P.O. BOX 460 CO

LLIERVILLE, TN U

SA 38027-0460 W

WW

.BO

DIN

E.COM

SALES 800.223.5728 FA

X 901.853.5009 TECH SU

PPORT 888.263.4638

04.2

PRODUCT NEWS

Q&A

Can the B50Cold-Pak® operate compact lamps?

No. The B50Cold-Pak® operates only linear lamps. However, Bodine will soon be offering two versions for compact lamps, the B4CF1 Cold-Pak (without conduit) and the B4CF2 Cold-Pak (with conduit).

The GTD™ Generator Transfer Device and GTD20™ Switch Bypass Device offer energy-saving

technology for generator- or central inverter system-supplied emergency lighting. The GTD

works with an auxiliary generator or central inverter system to power fluorescent emergency

lighting regardless of local light switch position (on/off). The device senses the loss of normal

power, bypasses the wall switch and supplies generator power directly to the AC ballast. The

GTD20 also works with an auxiliary generator or central inverter system to power emergency

lighting regardless of local light switch position (on/off). The GTD20, however, handles most

switchable lighting loads (fluorescent, HID, incandescent) up to 20 amps. The GTD is installed

in areas where only one fixture may be needed for egress lighting, such as a classroom or a

stairwell, or in areas where multiple switches are in use. The GTD20 generally is specified when

bypassing one wall switch controlling multiple fixtures, such as might be found in a

long corridor or conference room. Both the GTD and GTD20 can make a big

difference in energy costs by reducing energy waste. The devices eliminate reliance

on night-light circuits and permit lighting to be turned off without jeopardizing

life safety. Because the GTD and GTD20 provide emergency lighting only when

it’s needed, thousands of energy hours can be saved each year. Continuous day- and night-

lighting operation expends 8,760 energy hours annually per fixture (24 hours per day x 365

days per year). Without night-lighting, that number drops to approximately 3,500 (assuming

an average 9.5 operating hours per day), saving users 5,260 energy hours per fixture over

the course of a year! Note that multiple fixtures – up to 20 amps – can be connected to one

GTD20. ��� ������� ��� ��� �����changeable.

Page 3: THE 04 - Bodinebodine.com/downloads/news/Vision04-02.pdf04.2 product news q&a ... gen series interim lighting backup ballasts for use with standby generator systems tran-bal

LP SHUTDOWN CIRCUIT PROTECTION

THE BATTERYIS THE BATTERY UL LISTED OR

UL RECOGNIZED? The battery

does not carry the UL mark (i.e., UL

does not list or recognize this type

of battery). However, the battery

as a part of the entire assembly is

UL Listed or Recognized, depending

upon the status of its host product.

DAMP MODELS

Below is a list of damp models with

their dry equivalent. Please note

that we do not yet have separate

spec sheets for damp models. For

now, the spec for the dry equivalent

should be used. All spec information

will be identical with the exception of

suitability for damp locations. Damp

spec sheets will be available soon.

DAMP DRY EQUIVALENT

BDL500 B50

BDL600 B60

BDL700 B70A

BDL900 B90

BDL94C B94C

BDL940 B94

BDL413 B413

BDL426 B426

BDL463 B463

BDL60U B60U

B30ST B30ST

B50Cold-Pak® B50Cold-Pak®

B50LP B50LP

(The standard model is damp-rated for B30ST, B50Cold-Pak and B50LP.)

VISION

bodine®

VISION

bodine®

Bodine’s newest LP Series low-profile emergency ballasts not only provide

90 minutes of emergency illumination with the newer T5 fluorescent lamps

but also offer shutdown circuit protection to ensure compatibility with most

electronic ballasts for T5 lamps. Shutdown circuitry is becoming more

prevalent in today’s electronic ballast designs in order to comply with new

ANSI standards regarding the safe handling of end-of-lamp-life conditions.

Bodine’s shutdown circuit protection consists of a time-delayed relay that

controls the reapplication of AC power to the electronic ballast when utility

power resumes. This feature allows for the entire lighting system (AC power,

electronic ballast and emergency ballast) to stabilize before the electronic

ballast attempts to restrike the lamps, which prevents inadvertent triggering

of the internal shutdown circuitry within the electronic ballast. The Bodine

models currently equipped with shutdown circuit protection include the

LP500, LP550 and LP600. If you have any questions about this article

or any other technical issues regarding Bodine emergency ballasts, please

contact us at 888-263-4638.

LITERATURE ONLINE

Don’t forget that Bodine’s literature is

available online at www.bodine.com/

downloads/. You may download

files from our website or you may

electronically request that hardcopies

be sent to you.

BODINEETC. COMYou can now buy direct our

award-winning hot sauces, garlics

and rubs from our new website,

www.bodineetc.com. Some of our

products are sweet,

some of our products

are hot and some of

our products are real,

real hot, but you can

be assured that each

and every one has an

incredible flavor that

will make the ordinary

dish extraordinary.

Page 4: THE 04 - Bodinebodine.com/downloads/news/Vision04-02.pdf04.2 product news q&a ... gen series interim lighting backup ballasts for use with standby generator systems tran-bal

TUBULAR & COMPACT FLUORESCENT EMERGENCY BALLASTS

REDITEST® SELF-TESTING EMERGENCY BALLASTS

RCT™ REMOTE CONTROL TESTING EMERGENCY BALLASTS

LOW-PROFILE EMERGENCY BALLASTS FOR ARCHITECTURAL LIGHTING APPLICATIONS

EXTENDED RUN-TIME EMERGENCY BALLASTS FOR TWO & FOUR HOURS OF EMERGENCY ILLUMINATION

SPECIAL APPLICATION EMERGENCY BALLASTS FOR SEALED & GASKETED; DAMP; AND HAZARDOUS LOCATION FIXTURES

UNIVERSAL INPUT EMERGENCY BALLASTS FOR 120-277 VAC INPUT VOLTAGE & INTERNATIONAL APPLICATIONS

CAN SERIES EMERGENCY BALLASTS (CSA-CERTIFIED) FOR 120/347 VAC INPUT VOLTAGE APPLICATIONS

CENTRAL BATTERY BALLASTS FOR USE WITH CENTRAL BATTERY SYSTEMS

GEN SERIES INTERIM LIGHTING BACKUP BALLASTS FOR USE WITH STANDBY GENERATOR SYSTEMS

TRAN-BAL® STANDARD & CUSTOM ELECTRONIC INVERTER BALLASTS FOR SPECIALTY LIGHTING APPLICATIONS

GTD™ GENERATOR TRANSFER DEVICE FOR USE WITH GENERATOR-SUPPLIED OR CENTRAL INVERTER-SUPPLIED LIGHTING

GTD20™ SWITCH BYPASS DEVICE FOR USE WITH GENERATOR-SUPPLIED OR CENTRAL INVERTER-SUPPLIED LIGHTING

COLD-PAK® SERIES EMERGENCY BALLASTS FOR USE IN EXTENDED-TEMPERATURE APPLICATIONS

PRODUCT LINESPRESORTED

FIRST-CLASS MAILU.S. POSTAGE PAIDCOLLIERVILLE, TNPERMIT NO. 168

bodine®

P. O. Box 460

Collierville, TN 38027-0460

Address Service Requested