ORDER CODE ER D A 1 - 2 25 Z * 25 and 40A AC load current. * 320 - 480V AC load voltage. * 8-30V AC/DC or 90-240V AC input voltage. * LED status indicator for input voltage. * Zero-cross switching. * Applicable for three phase loads. * Built-in varistor protection. * Rail mountable. * CE marked according to European Norms. Product Basic Code Ray tipi SSR Input voltage 8-30V AC/DC 90-240V AC Load voltage AC single phase ER D A A OUTPUT INPUT Order Code Load current, AC51/25ºC (Arms) Load voltage (Vrms) Overload current t=1s/25°C (Arms) Non rep.surge current/25°C (Arms) On-state voltage drop (Vrms) Leakage current (mArms) I²t for fusing t=10ms (A²s) Frequency (Hz) Min. operating current (mArms) ERDA1-xxxZ 8 - 30Vac/dc > 6Vac/dc < 2Vac/dc < 17mAac/10mAdc Maximum ½ Period ERAA1-xxxZ 90 - 240Vac > 75Vac < 6Vac < 8mAac Maximum 2 Period Input voltage Pick-up voltage Drop-out voltage Input current Turn-on time Turn-off time Load current 25A AC 40A AC 25 40 Switching Zero crossing Z ENVIRONMENTAL CONDITIONS -25... +60 °C / -30... +100 °C (Shouldn't be icing and condensation in ambient). 50% Relative humidity for +40°C temperature increases up to 90% at +20°C (Shouldn't be condensation). ° 2 II Max. 1000m IP20 According to EN60529 Ambient/storage temperature Relative humidity Pollution degree Overvoltage category Altitude Protection LED indicator If the input voltage >6V ac/dc, LED lights up. If the input voltage >75V ac, LED lights up. Order Code 2500 Vrms 1 between I/O terminals for 1 min. M4 screw-type (2x4mm² cable or 1x 1x6mm² cable with insulated terminals. Max. 1,2Nm EN 60947-4-3 Approx. 203 g (After packaging) Approx. 280 g (After packaging) Order Code Isolation Voltage Connection Mounting Enclosure material Dimensions Weight GENERAL While cleaning the device,solvents (thinner,benzine,acid etc.) or corrosive materials must not be used. Rail mountable (EN60715,TH35 or G-32) Self extinguishing plastics (According to EN 60695-11-10 V-O) W24xH84xD97mm ERxA1-x25Z W30xH84xD115mm ERxA1-x40Z Terminal screw torque Load voltage 24-280V AC 50-480V AC 2 4 Pole number Single pole 1 Product standard ENDA ERDA1 / ERAA1 Rail Mountable Solid State Relays With Integrated Heat Sink Thank you for choosing ENDA ERDA1 / ERAA1 Solid State Relays. Do not use the device in locations subject to corrosive and flammable gases. accept any compensations for personal injury, material damage or capital disadvantages. damaging of the device if you don't attend to the directions in the user manual. Also we don't Read this document carefully before using this device. The guarantee will be expired by ERxA1-225Z 25 85 250 ERxA1-240Z 40 150 400 880 24 - 320 1,6 5 50 - 60 ERxA1-425Z 25 70 190 265 1,8 8 50 - 60 50 - 480 ERxA1-440Z 110 40 610 290 160 200 340 Maximum ½ Period Maximum 1 Period 1/2 SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş. Şerifali Mah. Y.Dudullu 34775 ÜMRANİYE/İSTANBUL-TURKEY Tel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01 url : www.enda.com.tr Barbaros Cad. No:18 ERxA1-xxxZ-E-R-04-201402

Thank you for choosing ENDA ERDA1 / ERAA1 Solid …...accept any compensations for personal injury, material damage or capital disadvantages. damaging of the device if you don't attend

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Thank you for choosing ENDA ERDA1 / ERAA1 Solid …...accept any compensations for personal injury, material damage or capital disadvantages. damaging of the device if you don't attend

ORDER CODE ER D A 1 - 2 25 Z

* 25 and 40A AC load current.* 320 - 480V AC load voltage.* 8-30V AC/DC or 90-240V AC input voltage.* LED status indicator for input voltage.* Zero-cross switching.* Applicable for three phase loads.* Built-in varistor protection.* Rail mountable.* CE marked according to European Norms.

Product Basic CodeRay tipi SSR

Input voltage8-30V AC/DC90-240V AC

Load voltageAC single phase

ER

DA

A

OUTPUT

INPUT

Order Code

Load current, AC51/25ºC (Arms)

Load voltage (Vrms)

Overload current t=1s/25°C (Arms)

Non rep.surge current/25°C (Arms)

On-state voltage drop (Vrms)

Leakage current (mArms)

I²t for fusing t=10ms (A²s)

Frequency (Hz)Min. operating current (mArms)

ERDA1-xxxZ

8 - 30Vac/dc

> 6Vac/dc

< 2Vac/dc

< 17mAac/10mAdc

Maximum ½ Period

ERAA1-xxxZ

90 - 240Vac

> 75Vac

< 6Vac

< 8mAac

Maximum 2 Period

Input voltage

Pick-up voltage

Drop-out voltage

Input current

Turn-on time

Turn-off time

Load current25A AC40A AC

2540

Switching

Zero crossing Z

ENVIRONMENTAL CONDITIONS

-25... +60 °C / -30... +100 °C (Shouldn't be icing and condensation in ambient).

50% Relative humidity for +40°C temperature increases up to 90% at +20°C (Shouldn't be condensation).°

2

II

Max. 1000m

IP20 According to EN60529

Ambient/storage temperature

Relative humidity

Pollution degree

Overvoltage category

Altitude

Protection

LED indicator

If the input voltage >6V ac/dc, LED lights up. If the input voltage >75V ac, LED lights up.

Order Code

2500 Vrms 1 between I/O terminals for 1 min. M4 screw-type (2x4mm² cable or 1x 1x6mm² cable with insulated terminals.

Max. 1,2Nm

EN 60947-4-3

Approx. 203 g (After packaging) Approx. 280 g (After packaging)

Order Code

Isolation Voltage

Connection

Mounting Enclosure material

Dimensions

Weight

GENERAL

While cleaning the device,solvents (thinner,benzine,acid etc.) or corrosive materials must not be used.

Rail mountable (EN60715,TH35 or G-32)

Self extinguishing plastics (According to EN 60695-11-10 V-O)

W24xH84xD97mm

ERxA1-x25Z

W30xH84xD115mm

ERxA1-x40Z

Terminal screw torque

Load voltage

24-280V AC50-480V AC

24

Pole number

Single pole 1

Product standard

ENDA ERDA1 / ERAA1 Rail Mountable Solid State Relays With Integrated Heat Sink

Thank you for choosing ENDA ERDA1 / ERAA1 Solid State Relays.

Do not use the device in locations subject to corrosive and flammable gases.

accept any compensations for personal injury, material damage or capital disadvantages. damaging of the device if you don't attend to the directions in the user manual. Also we don't Read this document carefully before using this device. The guarantee will be expired by

ERxA1-225Z

25

85

250

ERxA1-240Z

40

150

400

880

24 - 320

1,6

5

50 - 60

ERxA1-425Z

25

70

190

265

1,8

8

50 - 60

50 - 480

ERxA1-440Z

110

40

610

290

160 200

340

Maximum ½ Period Maximum 1 Period

1/ 2

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.Şerifali Mah. Y.Dudullu 34775ÜMRANİYE/İSTANBUL-TURKEYTel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01url : www.enda.com.tr

Barbaros Cad. No:18

ERxA1-xxxZ-E-R-04-201402

Page 2: Thank you for choosing ENDA ERDA1 / ERAA1 Solid …...accept any compensations for personal injury, material damage or capital disadvantages. damaging of the device if you don't attend

DIMENSIONS

CONNECTION EXAMPLES

Single Phase Load Application Three Phase Load Application With The Two SSRs Three Phase Load Application With The Three SSRs

For ERxA1-x40Z ; For ERxA1-x25Z ;

80 mm

25 mm

25 mm

Loa

d C

urr

en

t (A

)

Ambient Temperature (°C)

10

20

30

40

20 40 60

IT(RMS) A

ERxA1-x25PA

ERxA1-x40PA

0

30 mm

24 mm 24 mm

1 1

104 mm 85 mm

84

mm

84

mm

2 2

6mm 6mm

ENDA

SOLID STATE RELAY

0 25 60 C

A

o

LOAD24-320VAC 40A

ERDA1-240Z

8-30V AC/DCINPUT 34

40

25

A

RELAY ON

21

+ +

++

ENDA

SOLID STATE RELAY

0 25 60 C

A

o

LOAD24-320VAC 25A

ERDA1-225Z

8-30V AC/DCINPUT 34

40

25

A

RELAY ON

21

+ +

++

WA

RN

ING

He

ats

ink

at

hig

h te

mp

era

ture

8680407713486

EN

DA

ER

DA

1-2

40

Z

WA

RN

ING

He

ats

ink

at

hig

h te

mp

era

ture

8680407713462

EN

DA

ER

DA

1-2

25

Z

- For removing the relay from the rail;

Pull up the relay in direction 1

- For mounting the relay to the rail;

Push down the relay in direction 2

- For removing the relay from the rail;

Pull up the relay in direction 1

- For mounting the relay to the rail;

Push down the relay in direction 2

Fuse

INPUT

INPUT

INPUT

RSTN

RST

RN

Load INPUT

Fuse

Fuse INPUT

INPUT

Fuse

Fuse

Fuse

2/ 2

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.Şerifali Mah. Y.Dudullu 34775ÜMRANİYE/İSTANBUL-TURKEYTel : +90 216 499 46 64 Pbx. Fax : +90 216 365 74 01url : www.enda.com.tr

Barbaros Cad. No:18

ERxA1-xxxZ-E-R-04-201402