20
• Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds. • Designed to work with equipment up to 3 ton. 120V-1-60HZ • Instructions in Spanish. • Control board. • Temperature sensor for room temperature and freezing sensor for malfunctioning events. • Transformer. • Remote control. • 3 Speeds. • Designed to work with equipment up to 5 ton. • 220V-1-60HZ. Integrates more than 4000 models in one remote controler. It has accurate clock timer on/off, code memory, and an “intelligent cool/heat” feature convenient for your use. • 4000 Codes. • LCD background display. • Clock display. • On/off timer. • Code memory. • Instructions in English, Spanish & Portuguese • Auto Programmable TH-MS-1 TH-MS-5M TH-MS TH-MS & TH-MS-5M UNIVERSAL CONTROL BOARDS FOR AC • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low, medium and high. • Designed to work with equipment up to 3 ton. 220V-1-60HZ • Instructions in Spanish. TH-MS TH-MS-5M TH-MSUR-40 UNIVERSAL REMOTE CONTROL 1 AIR CONDITIONING

TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

•  Control board.•  Temperature sensor.•  Transformer.•  Remote control.•  3 Speeds.•  Designed to work with equipment up to 3 ton.•  120V-1-60HZ•  Instructions in Spanish.

•  Control board.•  Temperature sensor for room temperature and          freezing sensor for malfunctioning events.

•  Transformer.•  Remote control.•  3 Speeds.•  Designed to work with equipment up to 5 ton.•  220V-1-60HZ.

Integrates more than 4000 models in one remote controler. It has accurate clock timer on/off, code memory, and an “intelligent cool/heat” feature convenient for your use. 

•  4000 Codes. •  LCD background display. •  Clock display. •  On/off timer. •  Code memory. •  Instructions in English, Spanish & Portuguese •  Auto Programmable

TH-MS-1

TH-MS-5M

TH-MSTH-MS & TH-MS-5M UNIVERSAL CONTROL BOARDS FOR AC

•  Control board.•  Temperature sensor.•  Transformer.•  Remote control.•  3 Speeds settings low, medium and high.

•  Designed to work with equipment up to 3 ton.

•  220V-1-60HZ•  Instructions in Spanish.

TH-MS

TH-MS-5M

TH-MSUR-40 UNIVERSAL REMOTE CONTROL

1

AIR CONDITIONING

Page 2: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

2

AIR CONDITIONING

AC LEAk FREEzE™• AC LEAk FREEZE PERmAnEnTLy SEALS LEAkS In 

AIR COnDITIOnIng AnD REFRIgERATIOn SySTEmS• WILL COnTInuE TO SEAL ADDITIOnAL LEAkS FOR 

uP TO 1 yEAR THAT mEET TESTIng SPECIFICATIOnS• DOES nOT COnTAIn POLymERS• nOT ACTIVATED by mOISTuRE OR OxygEn• TESTED TO bE nOn-CLOggIng TO A/C COmPRES-

SOR AnD RECOVERy unIT• IDEAL FOR PREVEnTIVE mAInTEnAnCE AnD LEAk 

PROTECTIOn• OEm APPROVED• PATEnT PEnDIng

Page 3: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

3

AIR CONDITIONING

Page 4: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

4

AIR CONDITIONING

TH-MSB REGULAR BRACkET kIT

450mm x 365mm x 1.8mm mAxImum LOAD: 180kgS uSE FOR 9000-18000 bTu A/C

Maximum load: 200kgs USE for 18000-24000 BTU A/C

Page 5: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

5

AIR CONDITIONING

550mm x 500mm x 2.0mm mAxImum LOAD: 200kgS uSE FOR 18000-24000 bTu A/C

TH-MSBP PREMIUM BRACkET kIT

Maximum load: 200kgs USD for 18000-24000 BTU A/C

Page 6: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

6

AIR CONDITIONING

Page 7: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

7

AIR CONDITIONING

Page 8: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

8

AIR CONDITIONING

Hard Start kitsSTT-5 START ASSISTANT•  InCREASES STARTIng TORQuE uP TO 300%.

•  InCREASES STARTIng TORQuE uP TO 500%.STT-6 START ASSISTANT

•  SPECIALLy DESIgnED FOR AIR   COnDITIOnIng EQuIPmEnT FROm 1/2HP   TO 10HP.•  TO bE uSED In OnE PHASE EQuIPmEnT WITH VOLTAgE SuPPLy FROm 120VAC uP TO 

  288VAC 50/60HZ.•  COmPATIbLE WITH Any EQuIPmEnT   SPECIFICATIOnS AnD THERE ARE nO   InTERFEREnCE WITH THE THERmAL PROTECTOR.•  SPADE FEmALE 0.250” QuICk COnnECTORS AnD mOunTIng bASE InCLuDED.

Universal Thermal Protectors•  InTEnDED AS unIVERSAL REPLACEmEnT FOR AIR COnDITIOnIng AnD REFRIgERATIOn EQuIPmEnT.

•  FEmALE 0.250” SPADE QuICk COnnECTORS.•  bODy DIAmETER 3/4”.

OP-120 115/220V

STT-5 STT-6

Potential Relays•  TOTALLy SEALED.•  DuAL mALE 0.25” SPADE COnnECTORS.•  CLASS b ELECTRICAL InSuLATIOn.•  SIngLE POLE COnTACTS.•  ELECTRICAL DIAgRAm InCLuDED.

90-067

model Capacity Electrical Parameters HPbTu-H LRA Voltage

OP-100 9000-10000 37 115/220 universal

OP-120 12000 37 115/220 1OP-150 15000 37 220 1 1/4OP-180 18000 34 115 1 1/2OP-190 19000 34 220 1 3/4OP-240 24000 35 220 2

model Continuous Pick - up Drop OutVoltage Volts Voltsin Coil min max max

90-063 170 139 153 5590-064 395 260 275 12090-065 332 168 182 9090-066 395 215 225 12090-067 420 295 315 12590-068 502 325 345 13590-069 336 180 195 10590-070 253 285 305 77

Universal

Page 9: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

9

AIR CONDITIONING

Time DelaysTDM-08 STARTING TIME DELAY

•  ADJuSTAbLE DELAy FROm 2 sec to 600 sec (10 min).•  DELAyS STARTIng TImE AFTER THE LOAD IS        EnERgIZED.

•  1.5 AmP, 15 AmP mAx, SPST, n.O.•  2” x 2” COmPACT bOx.•  unIVERSAL VOLTAgE FROm 18-288 VAC/VDC.•  0.25” SPADE mALE COnnECTOR.

TDB-08 SEQUENCE TIME DELAY

•  ADJuSTAbLE DELAy FROm 1 SEC-300 SEC (5 mIn)•  DELAyS COmPRESSOR STARTIng TImE WHEn An InTERRuPTIOn OCCuRS AVOIDIng PRObLEmS     ASSOCIATED TO SHORT AnD REPETITIVE CyCLES.

•  1.5 AmP, 15 AmP mAx, SPST, n.O.•  2” x 2” COmPACT bOx.•  unIVERSAL VOLTAgE FROm 18-288 VAC/VDC.•  0.25” SPADE mALE COnnECTOR.

TDM-08

TDB-08

Transformers

•  COIL PROTECTOR EnSuRES LOng LASTIng LIFE.•  EASy InSTALLATIOn bECAuSE OF COmPACT SIZE.•  gALVAnIZED STEEL FOOT mOunTIng bASE.•  ELECTRICAL COnECTIOn DIAgRAm EnCLOSED In ATTACHED LAbEL On EACH unIT.

•  FRECuEnCy 50/60HZ.

T4OVA

T75VA

model Capacity Input OutputVA VAC VAC

T40VA 40 120/208/240 24T50VA 50 120/208/240 24T75VA 75 120/208/240 24T75VA-480 75 120/208/240/480 24

Page 10: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

10

AIR CONDITIONING

ARTICCO’S COnTACTORS COmbInE A HEAVy DuTy COnSTRuCTIOn InA COmPACT SIZE WHICH mAkES THEm IDEAL FOR REPLACEmEnT WITHIn ExISTIng AIR COnDITIOnIng OR REFRIgERATIOn EQuIPmEnT. WE ARE PROVIDIng COVERS AS A STAnDARD FEATuRE TO  ALL OF OuR COnTACTORS. 

DEFINITE PURPOSE CONTACTORS

2 POLES 3 POLES

AVAILABLE MODELS & SPECIFICATIONS

ADDITIONAL MODELS >>

Page 11: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

11

AIR CONDITIONING

CONTINUED

Page 12: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

12

AIR CONDITIONING

90-380

ARTICCO’S HEAVy DuTy FAn RELAyS COmE EQuIPPED WITH A muLTIPOSITIOnAL  mOunTIng bRACkET AnD ARE CAPAbLE OF HAnDLIng HEAVIER LOADS THAn TRADITIOnAL FAn RELAyS WITHIn A VERy COmPACT bODy SIZE. InDIVIDuALLy PACkED.

FEATURES•  TOTALLy EnCLOSED FOR DuST   PROOF OPERATIOn.•  TERmInALS .250” mALE QuICk   COnnECTORS.•  FREQuEnCy 50/60 HZ.•  mECHAnICAL LIFE 1,000,000 OPERATIOnS.•  ELECTRICAL LIFE 250,000 OPERATIOnS On    RESISTIVE LOADS AnD 100,000 On                  InDuCTIVE LOADS.

HEAVY DUTY FAN RELAYS

90-360

90-370

modelContactsVoltageVAC 

AmpControl Style Coil Voltage

VACFLA LRA Voltage

90-360120240277

1287

604842

181818

SPST-nO 24

90-370120240277

1287

604842

181818

SPDT 24

90-380120240277

1287

604842

181818

SPnO-SPnC 24

Page 13: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

13

AIR CONDITIONING

modelContactsVoltageVAC 

AmpControl Style Coil Voltage

VACFLA LRA Voltage

90-360120240277

1287

604842

181818

SPST-nO 24

90-370120240277

1287

604842

181818

SPDT 24

90-380120240277

1287

604842

181818

SPnO-SPnC 24

ARTICCO’S SWITCHIng RELAyS HAVE mAny APPLICATIOnS In AIR COnDITIOnIng, REFRIgERATIOn AnD HEATIng EQuIPmEnT. OuR RELAyS HAVE POWER DuTy COnTACTS AnD COmE AVAILAbLE In 24, 120, AnD 208/240 COIL VOLTAgE

FEATURES

muLTI-POSITIOnAL gALVAnIZED STEEL mOunTng bRACkET.TERmInAL .250” mALE QuICk COnnECTORS.mECHAnICAL LIFE 1,000,000 OPERATIOnS.ELECTRICAL LIFE 250,000 OPERATIOnS On RESISTIVE LOADS; 100,000 OPERATIOnS On In-DuCTIVE LOADS.

90-340

GENERAL PURPOSE RELAYS

Visit our Showroom!

Page 14: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

14

AIR CONDITIONING

Run Capacitors•  AnODIZED ALumInum CAn FOR A RuST PROOF PRODuCT.•  InTERnAL SWITCH DISCOnECT THE CAPACITOR WHEn ExCESIVE InSIDE PRESSuRE OCCuRS.

•  TERmInALS WITH FOuR 0.25” mALE SPADE COnECTORS In EACH OnE OF THEm.

•  ROunD CAn TyPE FOR EASIER InSTALLATIOn.•  uL AnD CE APPROVAL CERTIFICATIOnS.•  SIngLE AnD DuAL unIT In mOST COmmOn CAPACITAnCE VALuES.

SINGLE CAPACITOR

DUAL CAPACITOR

DRY CAPACITOR

SINGLE CAPACITOR370V

DUAL CAPACITOR370V

SINGLE CAPACITOR440V

DRY CAPACITOR450V

model CapacitymFD

370V-4 mFD 4 370V-5 mFD 5370V-10 mFD 10370V-12.5 mFD 12.5370V-15 mFD 15370V-17.5 mFD 17.5370V-20 mFD 20370V-25 mFD 25370V-30 mFD 30370V-35 mFD 35370V-40 mFD 40370V-45 mFD 45370V-50 mFD 50370V-55 mFD 55370V-60 mFD 60370V-70 mFD 70370V-80 mFD 80

model Capacity     mFD

450-1 1450-1.5 1.5450-2 2450-2.5 2.5450-3 3450-3.5  3.5450-4  4450-4.5  4.5450-5  5450-6  6450-7.5  7.5450-8  8450-10  10450-12.5 12.5450-15  15

model Capacity     mFD

370V-25+5 mFD 25+5370V-30+5 mFD 30+5370V-35+5 mFD 35+5370V-40+5 mFD 40+5370V-45+5 mFD 45+5370V-50+5 mFD 50+5370V-55+5 mFD 55+5370V-60+5 mFD 60+5

model Capacity     mFD

440V-25 mFD 25440V-30 mFD 30440V-35 mFD 35440V-40 mFD 40440V-45 mFD 45440V-50 mFD 50440V-55 mFD 55440V-60 mFD 60440V-70 mFD 70440V-80 mFD 80

110v, 220v, 330v

MOTOR START CAPACITOR ARTICCO’S MOTOR START CAPACITOR IS A DRY ELECTROLYTIC DEVICE INTENDED TO PROVIDE THE NECESSARY TORQUE TO START AC MOTORS THAT REQUIRE A HIGHER STARTING TORQUE IN RELATION TO THEIR RUNNING TORQUE. START CAPACITORS ARE RATED BY MINIMUM AND MAXIMUM MICROFARAD GENERATED AT A SPECIFIC VOLTAGE.

FEATURES:•  COMPACT SIZE MAKES THEM AN IDEAL REPLACEMENT UNIT.•  CAPACITORS ARE HERMETICALLY SEAL TO PREVENT DAMAGE FROM MOISTURE AND OIL.•  STRONG BACKELITE CASE.•  TERMINALS DUAL .250” MALE QUICK CONNECTORES.

Page 15: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

The TH-57V is an attractive low voltage (24V) wall                    Thermostat. They come in a white color that blends well with any decoration. The manual control setting and dual temperature readings, °C and °F, makes them very simple to operate. These features combined with their economical pricing makes them ideal for new installation. 

•  mercury Free•  new magnetic switch•  Switch action SPDT.•  Electrical rating 24 to 30 VAC •  System control function on / off and fan on /auto.•  Set point range from 50°F to 90°F , 10°C to 32°C.•  Dimensions 2¾” x 4½” x 1¼”.•  mounting hardware and instruction provided.

TH-57V COOLING ONLY THERMOSTAT

15

AIR CONDITIONING

THERMOSTAT GUARD

•  InTEnDED TO PROTECT THE THERmOSTAT      FROm unAuTHORIZED mISuSE.•  CAPAbLE TO PROTECT PHASE mOnITORS In      THE SAmE WAy.•  CLEAR PLASTIC COVER ALLOWS AmPLE   VISuAL FIELD mAkIng IT IDEAL FOR        SmALL SPACES.•  CuSTOmER DECIDES mOunTIng DIRECTLy On    THE WALL OR uSIng THE   InCLuDED Sub-bASE.•  EASy InSTALLATIOn On ExISTIng •   THERmOSTAT WITHOuT REmOVIng THEm.•  mOunTIng SCREWS AnD TWO mETALLIC   kEyS PROVIDED.

model Length Width HeightTH-P36 6 3/8” 3 1/2” 3”TH-P58 8 1/8” 4 5/8” 3 5/8”TH-P54 5 1/4” 4 5/8” 3 1/4”

Page 16: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

16

AIR CONDITIONING

Window and Wall Air Conditioner Thermostat

Room Air Conditioning Thermostat with Cross Ambient Bulb

•  WIDE TEmPERATuRE RAngE FROm 10°C/50°F uP TO 32°C/90°F.

•  FROnT mOunTIng ACCESSORIES InCLuDED.•  PLASTIC COVER FOR TERmInALS PROTECTIOn In REAR PART.

•  48” STRAIgHT CAPILLARy buLb.

• WIDE TEmPERATuRE RAngE FROm 10ºC/50ºF TO 32ºC/90ºF.• FROnT mOunTIng bRACkET• SHAFT HALF mOOn  0.250" DIAmETER AnD   0.500" LEngTH. • 18" COIL TyPE CAPILLAR.

• WIDE TEmPERATuRE RAngE FROm 15.5ºC/60ºF TO      31ºC/87.5ºF.• FROnT mOunTIng bRACkET• SHAFT HALF mOOn  0.250" DIAmETER AnD   1.500" LEngTH. • 0.250" mALE SPADE QuICk COnnECTORS.• 18" STRAIgTH TyPE CAPILLAR.

•  WIDE TEmPERATuRE RAngE FROm 10°C/50°F uP TO 32°C/90°F.

•  FROnT mOunTIng bRACkETS InCLuDED.•  15” CAPILLARy LEngTH WITH 3” LOng buLb OF 3/8” DIAmETER.

•  SHAFT HALF mOOn. 250” DIAmETER AnD 1/2.  500” LOng.

TH-004

TH-008

TH-1884

TH-36

model Temp Range Temp. Electrical Switch bulb  bulbmax / min Differential Parameters Type Length Type

TH-004 32ºC / 10ºC 2.5ºC 25 FLA SPST 1.2 m Straight 90ºF / 50ºF 4ºF 95LRA 48”

model Temp Range Temp. Electrical Switchmax / min Differential Parameters Type

TH-36 32ºC / 10ºC 2.5ºC 20 FLA SPST 90ºF / 50ºF 4ºF 80LRA

TH-008 WInDOW A/C THERmOSTAT 

TH-1884 WInDOW A/C THERmOSTAT 

Model Temp. Range Temp. Electrical Switch Max / Min Differential Parameters Type

TH-008 32ºC / 10ºC 2.5ºC 25 FLA SPST90ºF / 50ºF 4ºF 95 LRA

Model Temp. Range Temp. Electrical Switch Max / Min Differential Parameters Type

TH-1884 31ºC / 15.5ºC 2.5ºC 25 FLA SPST87.5ºF / 60ºF 4ºF 100 LRA

Model Temp. Range Temp. Electrical Switch Max / Min Differential Parameters Type

TH-008 32ºC / 10ºC 2.5ºC 25 FLA SPST90ºF / 50ºF 4ºF 95 LRA

Model Temp. Range Temp. Electrical Switch Max / Min Differential Parameters Type

TH-1884 31ºC / 15.5ºC 2.5ºC 25 FLA SPST87.5ºF / 60ºF 4ºF 100 LRA

TH-004

Page 17: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

17

AIR CONDITIONING

Mini Pressure ControlsPSL25-80 LOW PRESSURE MINI CONTROL•  LOW PRESSuRE FIxED PRESOSTAT  FOR uSE In COnTROL CIRCuIT.

•   InTEnDED TO OPEn CIRCuIT WHEn PRESSuRE FALLS bEyOnD LOWER LImITS AnD CLOSE IT WHEn IT RETuRnS TO nORmAL VALuES.

PSH350-250 HIGH PRESSURE MINI CONTROL•  FIxED HIgH PRESSuRE mInICOnTROL WITH SAmE   FunCTIOnIng mETHOD THAn THE AbOVE mODEL.•  OPEnS THE CIRCuIT WHEn PRESSuRE IS HIgHER THAn    PERmISSIbLE LImITS.•  COnTACTS WILL bE CLOSED AuTOmATICALLy WHEn      PRESSuRE LEVELS RETuRn TO nORmAL VALuES.•  COnnECTIOn CAbLES 12” LOng.•  COmPACT bODy WITH bROnZE DEPRESSOR        InCORPORATED AnD 1/4” SAE COnnECTOR.•  SPST SWITCH.•  EASy COLOR CODE IDEnTIFICATIOn: bLACk bODy FOR     HIgH PRESSuRE AnD gREEn FOR LOW PRESSuRE.

PSL25-80 / PSH350-250

model Pressure  Settings Refrigerant

Application Disconnection Connection

PSL25-80 Low 25 PSIG 80 PSIG R22PSH350-250 High 350 PSIG 250 PSIG R22PSL75-100 Low 75 PSIG 100 PSIG R410aPSH600-475 High 600 PSIG 475 PSIG R410aPSL40-80 Low 40 PSIG 80 PSIG R134aPSH550-450 High 550 PSIG 450 PSIG R410a

Page 18: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

18

AIR CONDITIONING

ARTICCO OFFER A LInE OF bALL VALVES FOR REFRIgERAnT uSE In AL HCFC AnD HFC REFRIgERAnTS AnD ASSOCIATED OILS. OuR LInE OFFERS COmPLETE SEALIng OF THE REFRIgERAnT LInE ISOLATIng THE REFRIgERAnT In LIQuID OR gAS PHASE In SIngLE OR bIDIRECTIOnAL FLOW, FOR SERVICE PuRPOSES. FOR OD COPPER TubE DIAmETERS gREATER THAn 1/2" THE VALVE COmES WITH A SHRADER ACCESS VALVE 1/4" SAE.

InCLuDES: (2) JumPER WIRES TO COmbInE InDIVIDuAL VALuES InTO DESIRED mFD RATIng 

2.5/5.0/5.0 mFD (12.5mFD) TOTALmEnTE COmbInADO 370VAC O 440VAC, 50-60 HZ -40O C A +70OC POR EIA SPEC. #456 mOTOR Run CAPACITOR, 2.5-15 mICROFARAD RATIng, 370-440VAC VOLTAgE, 60/50 HZ, ROunD SHAPE, 1-3/4 In. DIAmETER, 2-5/16 In. CASE HEIgHT, 1-3/4 In. OVERALL WIDTH, TERmInAL TyPE 1/4 In. mALE QuICk-COnnECT, -40 DEgREES TO 70 DEgREES C TEmP. RAngE, CASE mATERIAL ALumInum, FOR uSE WITH (14) DIFFEREnT SIZE mOTORS, STAnDARDS uL RECOgnIZED (E133000), 

12100 UNIVERSAL MOTOR RUN CAPACITOR

VB bALL VALVES

model Connection Dia. Inches Access ValveVb-38 3/8” ODF N/AVb-12 1/2” ODF N/AVb-58 5/8” ODF 1/4” SAEVb-34 3/4” ODF 1/4” SAEVb-78 7/8” ODF 1/4” SAEVb-118 1-1/8” ODF 1/4” SAEVb-138 1-3/8” ODF 1/4” SAEVb-158 1-5/8” ODF 1/4” SAEVb-218 2-1/8” ODF 1/4” SAE

Visit our Showroom!

Page 19: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

19

AIR CONDITIONING

Shut Off Valves

•  COnSTRuCTED In bROnZE AnD EQuIPPED WITH REInFORCED PLASTIC STEERIng WHEEL FOR SECuRE gRIP.

•  VALVE DESIgn DOES nOT ALLOW mOISTuRE TO EnTER THE DIAPHRAgm CHAmbER.

•  FuLL FLOW APERTuRE PROVIDE mInImAL RESTRICTIOn AnD LESS PRESSuRE LOSS.

•  HEx nuTS InCLuDED FOR FLARE VALVES WITHOuT ADDITIOnAL COST.

Moisture Indicators•  bODy mADE OF bROnZE.•  unbREAkAbLE AnD LEAk PROOF FROnT gLASS.•  EASy READIng OF mOISTuRE COnTEnT bASED In COLOR CODED SCALE.•  HEx nuTS InCLuDED FOR FLARE SIgHT gLASSES WITHOuT ADDITIOnAL COST.•  COOPER ExTEnDER InCLuDED FOR SOLDER mODEL.

VP-38S

VP-38

SG-14F TO SG-78S

model Connection Type

VP-14 1/4” SAE FlareVP-38 3/8” SAE FlareVP-12  1/2” SAE FlareVP-58 5/8” SAE FlareVP-14S 1/4” ODF SolderVP-38S 3/8” ODF SolderVP-12S 1/2” ODF SolderVP-58S 5/8” ODF SolderVP-34S 3/4” ODF SolderVP-78S 7/8” ODF Solder

model Connection TypeInches

Sg-14F 1/4” SAE FlareSg-38F 3/8” SAE FlareSg-12F 1/2” SAE FlareSg-58F 5/8” SAE FlareSg-14S 1/4” ODF SolderSg-38S 3/8” ODF SolderSg-12S 1/2” ODF SolderSg-34S 3/4” ODF SolderSg-58S 5/8” ODF SolderSg-78S 7/8” ODF Solder

Page 20: TH-MSUR-40articco.com/wp-content/uploads/2016/10/master2016pdf_acnew.pdf · • Control board. • Temperature sensor. • Transformer. • Remote control. • 3 Speeds settings low,

20

AIR CONDITIONING