    What Do all these options do?• Many options available in the contextual

    menu of the product

  • 8/17/2019 Tgs Managing Large Assemblies

    4/70

    5 Ways of managing data in CATIA V5

    • Show vs. No-Show

    • Node Activation vs. Node Deactivation• Activate component vs. Deactivate

    component

    •  Visualization Mode vs. DesignMode

    • Load vs. Unload

  • 8/17/2019 Tgs Managing Large Assemblies

    5/70

    1. Show vs No-Show•  A tool to hide unwantedgeometry

     No-Show

    Show

     Advantages: Improves Graphic Performance, Geometry still editable

     Disadvantages: Ignored by drafting workbench, not used in DMU applications, used to

    measure mass properties

  • 8/17/2019 Tgs Managing Large Assemblies

    6/70

    2. Activate Node Vs. Deactivate Node

    • Manages graphic representation

    • Node deactivation – No graphicrepresentation at all is loaded

    • Hide/Show – Hide graphic

    representation of specific elements inmodel

    • Node Deactivation – Hide graphicrepresentaton of entire model

  • 8/17/2019 Tgs Managing Large Assemblies

    7/70

     Activate Node vs. Deactivate Node

    Red Axis White Axis

     Advantages: Better graphic performance, create/update assembly constraints

     Disadvantages: Loaded in memory but geometry not modifiable, not used by drawings

    ingored by DMU applications

  • 8/17/2019 Tgs Managing Large Assemblies

    8/70

     Node activation / deactivation• Use contextual menu

    Activate/Deactivate Node – 

    Select a part instance

    Activate/Deactivate Terminal

     Node – Select a product

    instance. All parts under the

     product will be

    activated/deactivated 

  • 8/17/2019 Tgs Managing Large Assemblies

    9/70

    Options for Node Activations

    • Sets initial behavior when loaded intoCATIA 

    DEMO

  • 8/17/2019 Tgs Managing Large Assemblies

    10/70

    3. Activate vs Deactivate Components

    • Don’t confuse with Node Activation/Deactivation

    • Hides the graphic representation of thecomponent

  • 8/17/2019 Tgs Managing Large Assemblies

    11/70

     Activate vs Deactivate Components

    Activated

    Component

    Deactivated

    Component

     Advantages: Better graphic performance, Can be accessed by knowledgeware

     Disadvantages: Loaded into memory, can’t update or edit geometry, ingnored by DMU

    applications and the drafting workbench

  • 8/17/2019 Tgs Managing Large Assemblies

    12/70

     Activate vs Deactivate Components

    • Can use contextual menu, not recommended

    • Use rules to have CATIA automatically togglecomponent activation

  • 8/17/2019 Tgs Managing Large Assemblies

    13/70

     Activate vs Deactivate Components

    Using a Rule to control

    the activation of a

    component

    DEMO

  • 8/17/2019 Tgs Managing Large Assemblies

    14/70

    4. Visualization vs. Design Mode

    • Improves performance by not loading

    the mathematical data of the part intomemory, only a visual of the geometryis loaded into memory.

  • 8/17/2019 Tgs Managing Large Assemblies

    15/70

    Visualization Mode• First Time a part is loaded into CATIA using

    visualization mode:

    CATIA creates a “lighter” version of the model andsaves it to the hard drive.

    Because it creates this light version the first time,it takes longer to load.

    Successive loads of this model, read the “light”version, which results in a quicker load time andbetter performance

    • File type .cgr – CATIA Graphic Representation

  • 8/17/2019 Tgs Managing Large Assemblies

    16/70

    CGR Files• Not Downward Compatible (Cgr files created

    in V5R14 cannot be read by CATIA V5R13 or

    lower)• Upward compatibility

    Files are upward compatible.

    However, in V5R14 cgr files were optimized• Recommend rebuild the cgr files if upgrading to V5R14

    • Sharable

    Set storage directory to server

     Also called Released Cache

  • 8/17/2019 Tgs Managing Large Assemblies

    17/70

     Accessing Visualization Mode• Tools+Options

    Activate Visualization Mode

    • Turn on the Cache

    • Requires a restart

  • 8/17/2019 Tgs Managing Large Assemblies

    18/70

     Additional OptionsCache Location – Place CATIA creates and savesthe cgr files

    •Read/write to the local cache first

    •Read/write to the released cache last

    •Released cache setup by administrator.Should be read-only

    Cache Size – sets a limit for the size of the cache

    directory. If limit is exceeded, cgr files are

    deleted, with oldest being deleted first, until

    directory size is below maximum size.

    CATIA uses timestamps to see if the cgr

    represents the latest version of the part.

    If not, a new cgr is created.

  • 8/17/2019 Tgs Managing Large Assemblies

    19/70

    Cache Location

     Recommend not using the default location

    C:\Documents and Settings\”user”\Local Settings\Application Data\DassaultSystemes\CATCacheDefault Cache Location

    Sample File LocationC:\Documents and Settings\”user”\My Documents\CATIA\Oil Pump drive.CATPart

    CGR File LocationC:\Documents and Settings\”user”\Local Settings\Application Data\DassaultSystemes\CATCache\cgr\#2\Documents and

    Settings\”user”jcosta\My Documents\CATIA\Oil Pump drive.CATPart.2004-04-22-15.45.42.cgr 

    Windows Limits: 255 characters for file name, including

    directory. Typical file uses 193 characters and filename is

    only 14 characters long.

  • 8/17/2019 Tgs Managing Large Assemblies

    20/70

    Cache Options

  • 8/17/2019 Tgs Managing Large Assemblies

    21/70

    Cgr Options

    Save lineic Options – CGR saves wireframe geometry

  • 8/17/2019 Tgs Managing Large Assemblies

    22/70

    Cgr Options

    •Loads only a subset of the cgr file

    •Loads the entire cgr file when needed •Only works for cgr files built in V5R14 or higher 

  • 8/17/2019 Tgs Managing Large Assemblies

    23/70

    Cgr Options

     Note: a cgr file is only updated when the CATPart it

    relates to is modified, so making changes to these cgroptions does not automatically update the cgr

    document. Delete the old cgr file and then CATIA

    will generate the new file

  • 8/17/2019 Tgs Managing Large Assemblies

    24/70

     Loading in Visualization Mode

  • 8/17/2019 Tgs Managing Large Assemblies

    25/70

     Loading in Visualization Mode

    Visualization ModeDesign Mode

    Tesselated data

     No Part History

    Document

     NameInstance Name

  • 8/17/2019 Tgs Managing Large Assemblies

    26/70

    Tesselated image• Quality of tesselated image controlled by accuracyparameters. Tools+options – General-Display-Performances

  • 8/17/2019 Tgs Managing Large Assemblies

    27/70

    Visualization Mode

    • Advantages

    Use less memory than Design Mode

    • Better Performance

    • Loads faster

    Perform Clash Analysis

    Perform Section Analysis Retrieve Inertia properties

  • 8/17/2019 Tgs Managing Large Assemblies

    28/70

    Visualization Mode• Perform Clash Analysis

  • 8/17/2019 Tgs Managing Large Assemblies

    29/70

    Visualization Mode• Perform Section Analysis

  • 8/17/2019 Tgs Managing Large Assemblies

    30/70

    Visualization Mode

    • Retrieve Inertia properties

    Cgr’s must be created with this

    option on. Otherwise, the inertia is

    calculated with the default density

    DEMO

  • 8/17/2019 Tgs Managing Large Assemblies

    31/70

    Visualization Mode

    • Disadvantages

    Cannot edit the geometry

    Cannot use to Design-in-Context

    Cannot use Assembly constraints toposition

    Some measurements are approximate. Accuracy is based on the tesselation of thecgr file

    Ignored by drawing documents

  • 8/17/2019 Tgs Managing Large Assemblies

    32/70

    Switching between design and

    visualization mode• 3 methods to convert from visualization to

    design mode

    Use the contextual menu- only optionavailable with this option turned off 

    Double click on the geometry or specification tree

    Open the specification tree of the part

    • Must use contextual menu to switch fromdesign mode to visualization mode

    Can only switch from design mode tovisualization mode if the cache is turned on

  • 8/17/2019 Tgs Managing Large Assemblies

    33/70

    Switching between design and

    visualization mode• Use the contextual menu (right mouse button)

    Multi-selection is available

    • Only way to switch from design to visualization mode

  • 8/17/2019 Tgs Managing Large Assemblies

    34/70

    Switching between design and

    visualization mode• Double click on the geometry or

    specification tree

    Double click

  • 8/17/2019 Tgs Managing Large Assemblies

    35/70

    Switching between design and

    visualization mode• Open the specification tree of the part

    Expand the tree

  • 8/17/2019 Tgs Managing Large Assemblies

    36/70

    Switching between design and

    visualization mode• CATIA automatically switches to design mode

    when it needs to access the geometric data

    Based on options• To update the assembly• For Design in Context

     Always

    • When creating a drawing

  • 8/17/2019 Tgs Managing Large Assemblies

    37/70

    • Update the Assembly

    • Recommend keeping this option turned offfor large assemblies

    •  Advantage

    Only the components which are manually

    loaded into design mode are updated.

    • Result: much better performance

     Automatic switching between design

    and visualization mode

  • 8/17/2019 Tgs Managing Large Assemblies

    38/70

    • Update the Assembly

    Constraints cannot be updated in visualization mode,

    automatically switch to design mode

     Automatic switching between design

    and visualization mode

  • 8/17/2019 Tgs Managing Large Assemblies

    39/70

     Automatic switching between design

    and visualization mode• Design in Context

    Case.1 is in visualization mode

    Create a sketch in screw CATPart

    Sketch references geometry in Case.1

    Case.1 automatically switches to design

    mode

    DEMO

  • 8/17/2019 Tgs Managing Large Assemblies

    40/70

     Automatic switching between design

    and visualization mode• Create a drawing

     A component must be in design mode to beprocessed by a drawing

    Several options available to manage largeassemblies

  • 8/17/2019 Tgs Managing Large Assemblies

    41/70

     Drawings and visualization mode• Before creating a view, CATIA displays a

    preview

    • Stay in Visualization mode

    • Previews quickly

    • Optimizes memory consumption

    • Recommended for large assemblies

    • Converts all components to design mode

    • Takes longer to preview

    • Uses more memory

    • recommended for small assemblies or

    individual parts

  • 8/17/2019 Tgs Managing Large Assemblies

    42/70

     Drawings and visualization mode

    • To create a view

    • Loads all components into memory

    • uses more memory and CPU

    • Generates view more quickly

    • Loads only the necessary components

    into memory

    • Uses less CPU and Memory

    • Takes longer to generate the view

    • recommended for Large Assemblies

  • 8/17/2019 Tgs Managing Large Assemblies

    43/70

     Drawings and visualization mode

    •  View Generation Mode

    Exact• Recommended. Try this first

    CGR 

    • Uses the CGR to generate the views.

    • Tesselated view, not as accurate• Uses less memory

    • Takes longer to generate

  • 8/17/2019 Tgs Managing Large Assemblies

    44/70

     Drawings and visualization mode

    •  View Generation Mode

     Approximate• Uses less memory than cgr• Is faster than cgr

    • Set LOD to control accuracy

    Raster

    • Generates the view as an image

    • Quickest

    • No dimensioning available

  • 8/17/2019 Tgs Managing Large Assemblies

    45/70

     Drawings and visualization mode

    •  View Generation Mode -Summary

    Exact CGR Approximate Raster

    Memory Usage Maximu

    m

    Less less minimum

    Generation Time Short Long Long Quickest

    Create all views Yes No No No

    Create Dimensions All Some (No

    radius/diameter 

    s)

    Some (No

    radius/diameter 

    s)

     None

    Associative dimensions Yes No No N/A

    Dressup Elements available Yes Yes Yes No

  • 8/17/2019 Tgs Managing Large Assemblies

    46/70

     Improving Graphic Performance in

    Visualization Mode• Tools + Customize

     Add two commands to a toolbar

     Affect Dynamic movements only Not persistent

  • 8/17/2019 Tgs Managing Large Assemblies

    47/70

     Improving Graphic Performance in

    Visualization Mode• Dynamic Level of detail

     Varies from 0 – 40.0

    Higher number = better performance• Dynamic Pixel Culling

     Varies from 0 to 40

    Higher number = better performance

    Objects disappear when zooming in, reappearwhen zooming out

    • Dynamic options only for current CATIAsession

    • Use defaults from settings at next login

  • 8/17/2019 Tgs Managing Large Assemblies

    48/70

     Improving Graphic Performance in

    Visualization Mode• Dynamic Pixel Culling

  • 8/17/2019 Tgs Managing Large Assemblies

    49/70

     Improving Graphic Performance in

    Visualization Mode• Dynamic Level of Detail

  • 8/17/2019 Tgs Managing Large Assemblies

    50/70

     Improving Graphic Performance

    • Options can be set under tools-options

    DEMO

  • 8/17/2019 Tgs Managing Large Assemblies

    51/70

    5. Unload Vs Load 

    • Whether or not component is loaded intomemory

    • No visualization• No Geometric information is loaded

    • Only thing visible is a node in the

    specification tree

  • 8/17/2019 Tgs Managing Large Assemblies

    52/70

     Load Vs Unload 

    Load Unload  

  • 8/17/2019 Tgs Managing Large Assemblies

    53/70

    Options for Load Vs Unload • Sets initial behavior when loaded into CATIA 

  • 8/17/2019 Tgs Managing Large Assemblies

    54/70

     Load/Unload component 

    • Use contextual menu

    • Can unload Parts and Products

  • 8/17/2019 Tgs Managing Large Assemblies

    55/70

    • Disadvantages Not Graphically visible Not used in DMU Not used in Drafting Can’t update Can’t be accessed by knowledgeware

    •  Advantage

    Not loaded into memory Can see the assembly structure

    • Why is this Useful?

     Load vs Unload 

  • 8/17/2019 Tgs Managing Large Assemblies

    56/70

     Load vs Unload 

    • Use when designing components in thecontext of a large assembly.

    • Components being designed only need toreference data from several of thecomponents in the assembly

    • Load these components• Unload everything else

    • Significant performance improvement

  • 8/17/2019 Tgs Managing Large Assemblies

    57/70

     Load vs Unload • 2 components loaded

    • 227 components unloaded

  • 8/17/2019 Tgs Managing Large Assemblies

    58/70

    Summary Norm

    al

    Hidde

    n

     Node

    Deactivated 

    Visualizatio

    n

    Unload  Deactivatecomponent

    Loaded in Memory Fully Fully Fully Limited No  Yes

    Display

    Performance

     Norm

    al

    Faste

    r

    Faster  Normal Faster Faster

    Visible in Show or No Show

    Yes Yes No Yes No No

    Visible in drafting Yes No  No No No No

    Create Assembly

    Constraints

    Yes Yes  Yes No No No

    Update Assembly

    Constraints

    Yes Yes Yes No No No

    Calculate in

    interference

    Yes No No Yes No No

    Calculate Mass Yes Yes No Depends No No

    Take Measures Yes Yes No Approxima

    te

    No No

    Geometry Editable Yes Yes No No No No

  • 8/17/2019 Tgs Managing Large Assemblies

    59/70

    Summary – Which mode to use• Hide/Show

    Temporarily hide model

    Hide a partial model

    •  Visualization mode

    DMU Analysis

    Creating Drawings

    • Node Deactivation

    Update BOM

    Update Assembly constraints

    • Unload

    Design in context

    • Deactivate Component

    Using knowledgeware rules

  • 8/17/2019 Tgs Managing Large Assemblies

    60/70

    • Best to use a skeleton model to drive design

    Manage Design Changes

    • Without a Skeleton Model

    Build a design loop

    Difficult to control changes

     Design in Context 

    Skeleton model

    PartA

    PartB PartC

    PartA PartB PartC

  • 8/17/2019 Tgs Managing Large Assemblies

    61/70

    Content of Skeleton Model

    •  Any information that will be shared bymultiple components

    • Geometry – planes, lines, surface etc• Parameters – radii of circles, lengths, etc

    • This information will be published

    •  Access to this file should be restricted.

  • 8/17/2019 Tgs Managing Large Assemblies

    62/70

    Skeleton Model Content 

    Parameters

    Geometry

    Tools+Publication

  • 8/17/2019 Tgs Managing Large Assemblies

    63/70

    Setting up the options

    Allows external references

    Displays dialog box beforecreating external links

    Strongly recommended.

    Increases stability of models

  • 8/17/2019 Tgs Managing Large Assemblies

    64/70

     Design in Context • When designing, use the

    geometry/parameters as if it were in theactive part.

    The data is copied into the active part with a linkto the original data

    Green Gear and link =

    Design in context

    Green P = External

    Geometry is published

    and updated 

  • 8/17/2019 Tgs Managing Large Assemblies

    65/70

    Updating External References

    • These external links can only be updated inthe context of the current assembly.

    • If out of context, links will not update

    Brown Gear + Lightning

    Bolt = Out of context

  • 8/17/2019 Tgs Managing Large Assemblies

    66/70

    Changing the context 

    • Change the context using the contextual menus

    • Only works if all external links are publishedelements

  • 8/17/2019 Tgs Managing Large Assemblies

    67/70

     Modifying the skeleton model

    • Change the skeleton model, and the changeswill propagate down to the design in context

    models

    The Yellow P indicates that this

    geometry needs to be updated in

    the part

    Modify the geometry in the

    Skeleton model, and the Design in

    context models will need an update

  • 8/17/2019 Tgs Managing Large Assemblies

    68/70

     Modifying the skeleton model

    • Making the change in one location, theskeleton model, modified 4 components

  • 8/17/2019 Tgs Managing Large Assemblies

    69/70

     Design in Context Summary

    • Use Skeleton Models

    • External geometry can be geometry orparameters

    • Only work with Published Geometry

    DEMO

  • 8/17/2019 Tgs Managing Large Assemblies

    70/70

    THANK YOU!

    • Recap Improve Graphic Performance

    • Good = Hide Component

    • Better = Deactivate Node, Visualization Mode

    • Best = Unload unneeded components

    Improve CPU Performance• Unload unneeded components

    Use Deactivate component viaKnowledgeware

     You can only modify geometry when it is