TF50F gas turbine For oil and gas applications Vericor Power Systems An MTU Aero Engines Company

TF50F gas turbine - Vericor Power Systems · PDF fileTF50F – technology features The TF50F gas turbine engine is designed for oil and gas applications such as hydraulic fracturing

Embed Size (px)

Citation preview

Page 1: TF50F gas turbine - Vericor Power Systems · PDF fileTF50F – technology features The TF50F gas turbine engine is designed for oil and gas applications such as hydraulic fracturing

TF50F gas turbineFor oil and gas applications

Vericor Power SystemsAn MTU Aero Engines Company

Vericor_TF50F_2015.qxd 30.01.2015 11:22 Uhr Seite 1

Page 2: TF50F gas turbine - Vericor Power Systems · PDF fileTF50F – technology features The TF50F gas turbine engine is designed for oil and gas applications such as hydraulic fracturing

TF50F – technology features The TF50F gas turbine engine is designed for oil and gas applications such as hydraulic fracturing pump drives and oil field electricpower generation. It builds on the heritage ofthe proven TF series engines in service aroundthe world in demanding industrial and navalenvironments.

The TF50F has high torque capability, is compact and has an unprecedented power/weight ratio reducing the equipment footprintof well pads. The TF50F’s free power turbinedesign eliminates the need for a transmissionand requires only a simple speed reductiongearbox, improving reliability. The TF50F’ssimplicity and modular design means reducedmaintenance costs.

An MTU Aero Engines Company

Vericor Power Systems LLC.3625 Brookside Parkway, Suite 500Alpharetta, GA 30022 • U.S.A.Tel. +1 770 569-8800Fax +1 770 569-7524E-mail [email protected] U

S 01

/15/

A/00

000/

DE/

EB/E

TF50F Engine Specifications

Rated Power 5,000 shaft HPWeight 1,475 lbsLength 52 inWidth 35 inHeight 41 inEmissions Below EPA Tier 4 – no methane slipFuel Flexibility 100% diesel or 100% natural gas

Key features

• Runs on 100% well head gas• Changeover from liquid to gaseous fuel

under power• Below EPA Tier 4 emissions• Modular construction• Highest power to weight ratio in this

size class• Cold start capability• Low cost of ownership

Representative savings*

• Operating cost: -80%• Frac spread footprint: -50%• Horsepower/unit: +100%• Emissions: -65%

* Gas turbine driven 4,500 hp pump vs two diesel driven 2,250 hp pumps

TF50F Gas Turbine

2,500-5,000 shp Pump

Speed Reduction Gearbox

Vericor_TF50F_2015.qxd 30.01.2015 11:22 Uhr Seite 2