82
Project No: 085-170503801-000 Date: 2017-12-20 Page: 1 of 39 Telephone : +86 20 38320668 Telefax : +86 20 38320478 http://www.tuv-sud. cn TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch, TÜV SÜD Group 5F, Communication Building, 163 Pingyun Rd, Huangpu Ave. West, Guangzhou, 501656, P.R.China Test Report issued under the responsibility of: NCB TÜV SÜD PSB 1 Science Park Drive, 118221 Singapore Singapore TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Report Number.............................. : 085-170503801-000 Date of issue ................................. : 2017-12-20 Total number of pages................... 39 Name of Testing Laboratory preparing the Report..................... : TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou Branch Applicant’s name .......................... : Opple Lighting Co., Ltd. Address ......................................... : Building 3, 1999 Lane, Zhang Heng Road, Zhang Jiang Pudong District, Shanghai, China. Test specification: Standard ........................................ : IEC 60598-2-3:2002 (Third Edition) + A1:2011 used in conjunction with IEC 60598-1:2014 (Eighth Edition) Test procedure .............................. : CB Scheme Non-standard test method ............ : N/A Test Report Form No. ................... : IEC60598_2_3K Test Report Form(s) Originator .... : Intertek Semko AB Master TRF .................................... : 2016-09 Copyright © 2016 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Project No: 085-170503801-000Date: 2017-12-20Page: 1 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Test Report issued under the responsibility of:NCB TÜV SÜD PSB1 Science Park Drive, 118221 SingaporeSingapore

TEST REPORTIEC 60598-2-3Luminaires

Part 2: Particular requirementsSection 3: Luminaires for road and street lighting

Report Number. ............................. : 085-170503801-000

Date of issue ................................. : 2017-12-20

Total number of pages ................... 39

Name of Testing Laboratorypreparing the Report ..................... :

TÜV SÜD Certification and Testing (China) Co., Ltd. GuangzhouBranch

Applicant’s name .......................... : Opple Lighting Co., Ltd.

Address ......................................... : Building 3, 1999 Lane, Zhang Heng Road, Zhang Jiang PudongDistrict, Shanghai, China.

Test specification:

Standard ........................................ : IEC 60598-2-3:2002 (Third Edition) + A1:2011 used in conjunctionwith IEC 60598-1:2014 (Eighth Edition)

Test procedure .............................. : CB Scheme

Non-standard test method ............ : N/A

Test Report Form No. ................... : IEC60598_2_3K

Test Report Form(s) Originator .... : Intertek Semko AB

Master TRF .................................... : 2016-09

Copyright © 2016 IEC System of Conformity Assessment Schemes for ElectrotechnicalEquipment and Components (IECEE System). All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as theIECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility forand will not assume liability for damages resulting from the reader's interpretation of the reproducedmaterial due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to theCB Scheme procedure shall be removed.

This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratoryand appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

General disclaimer:

The test results presented in this report relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing CB TestingLaboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB,responsible for this Test Report.

Page 2: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Project No: 085-170503801-000Date: 2017-12-20Page: 2 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Test item description ...................... : Luminaires for road and street lighting (LED Street light)

Trade Mark ...................................... : OPPLE

Manufacturer................................... : Suzhou Opple Lighting Co., Ltd.

Address ......................................... : East Side, Fenyang Road, Fenhu Economic Development Zone,Wujiang City, Jiangsu Province, P.R. China

Model/Type reference ..................... : LED SL-PQ 100W, LED SL-PQ 120W, LED SL-PQ 150W

Ratings ............................................ : 220-240V~, 50/60Hz, Max. 150W, LEDs, 3000/4000/5700K, class I,IP 66, RG2.

Page 3: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2
Page 4: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Project No: 085-170503801-000Date: 2017-12-20Page: 4 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

List of Attachments (including a total number of pages in each attachment):

Attachment 1: IEC 62031:2008+A1:2012+A2:2014(9 pages)

Attachment 2: Additional requirements of VC8055 for South Africa (3 pages)

Attachment 3: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-1(9 pages)

Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages)

Attachment 5: IEC/TR 62778:2014(2 pages)

Attachment 6: Photo report (6 pages)

Summary of testing:

The product was considered belong to RG2 according to IEC/TR 62778:2014.

Tests performed (name of test and testclause):

1. These luminaires were found to be compliedwith the test clauses mentioned aboveaccording to standard IEC 60598-1:2014,IEC 60598-2-3:2002+A1:2011.

2. IEC 62031:2008+A1:2012+A2:2014 isconsidered, see attachment 1.

3. IEC/TR 62778:2014 is considered, seeattachment 5.

4. Australia and New Zealand NATIONALDIFFERENCES is considered, see attachment3 and 4.

5. Additional requirements of VC8055 for SouthAfrica is considered, see attachment 2.

Testing location:

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch.

5F, Communication Building, 163 Pingyun Rd,Huangpu Ave. West Guangzhou 510656 P. R.China.

Summary of compliance with National Differences:

National Differences for Kuwait, Iraq, Iran, Israel, UAE, are considered. in report and test on Ta: 45oC

Page 5: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Project No: 085-170503801-000Date: 2017-12-20Page: 5 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Copy of marking plate:

Name label :

Show one for representative, others have same format, different in rated parameters and modelname.

The height of the letters is not less than 2mm, the height of the symbol is not less than 5mm, the heightof the WEEE symbol is not less than 7mm. The labels are representative, other models of the sameseries have similar format.

Symbol for warning “Risk of electric shock”, sticks on metal enclosure, height at least 15mm.

Do not stare at the operating light source.

Note:According to the EU decision, the name and address of manufacturer (an EU-based importer orauthorized representative if the manufacturer is not based in EU) shall be affixed on the product or,where that is not possible, on its packaging or in a document accompanying the product before theproduct is placed on EU market.

Page 6: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Project No: 085-170503801-000Date: 2017-12-20Page: 6 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Test item particulars .............................................. : Luminaires for road and street lighting (LED Streetlight)

Classification of installation and use ..................... : Fixed and outdoor use

Supply Connection ................................................ : Power cord

Possible test case verdicts:

- test case does not apply to the test object .......... : N/A

- test object does meet the requirement ................ : P (Pass)

- test object does not meet the requirement .......... : F (Fail)

Testing ................................................................... :

Date of receipt of test item ..................................... : 2017-09-06

Date (s) of performance of tests ............................ : 2017-09-07 to 2017-12-10

General remarks:

"(See Enclosure #)" refers to additional information appended to the report."(See appended table)" refers to a table appended to the report.

Throughout this report a comma / point is used as the decimal separator.

Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:

The application for obtaining a CB Test Certificateincludes more than one factory location and adeclaration from the Manufacturer stating that thesample(s) submitted for evaluation is (are)representative of the products from each factory hasbeen provided ...........................................................:

Yes

Not applicable

When differences exist; they shall be identified in the General product information section.

Name and address of factory (ies) ........................ : 1. Suzhou OPPLE Lighting Co., Ltd.East Side, Fenyang Road, Fenhu EconomicDevelopment Zone, Wujiang City, Jiangsu Province,P.R. China.2. Opple Lighting Electronic (Zhongshan) Co., Ltd.Building A, No.275 Dongan Bei Road, HaizhouDistrict, Guzhen Town, Zhongshan City, Guangdong,China.

Page 7: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Project No: 085-170503801-000Date: 2017-12-20Page: 7 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

General product information:

1. These products are Class I LED street light and tunnel light, for outdoor use.2. IP classification: IP66.3. The street light with non-user replaceable light source.

Model list

ModelRatedinput

Ratedwattag

e

Colourtemperatu

re

LED driver used(non-SELV type)

Dimension

LED SL-PQ150W

220-240V~,50/60H

z

150W

3000K

4000K5700K

EUP-150S105SV

375mm*107mm*110mm

LED SL-PQ120W 120W

EUP-150S070SVLED SL-PQ100W 100W

All of the models of luminaires have a same construction, number of LEDs and size, just different in thepower and the type of LED driver used.

Page 8: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 8 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.2 (0) GENERAL TEST REQUIREMENTS P

3.2 (0.1) Information for luminaire design considered ............ : Standard

Yes No

3.2 (0.3) More sections applicable ........................................ : Yes No

3.4 (2) CLASSIFICATION P

3.4 (2.2) Type of protection .................................................. : Class I

3.4 (2.3) Degree of protection ............................................... : IP 66

3.4 (2.4) Luminaire suitable for direct mounting on normallyflammable surfaces ................................................ :

Yes No

3.4 (2.5) Luminaire for normal use ....................................... : Yes No

Luminaire for rough service .................................... : Yes No

3.4 (-) Modes of installation of road or street lighting

a) on a pipe Yes No

b) on a mast arm Yes No

c) on a post top Yes No

d) on span or suspension wires Yes No

e) on a wall Yes No

3.5 (3) MARKING P

3.5 (3.2) Mandatory markings P

Position of the marking Name label on the metalenclosure of luminaire

P

Format of symbols/text P

3.5 (3.3) Additional information P

Language of instructions P

3.5 (3.3.1) Combination luminaires N/A

3.5 (3.3.2) Nominal frequency in Hz 50/60 P

3.5 (3.3.3) Operating temperature Ta: 45 oC P

3.5 (3.3.4) Symbol or warning notice N/A

3.5 (3.3.5) Wiring diagram N/A

3.5 (3.3.6) Special conditions N/A

Page 9: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 9 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.5 (3.3.7) Metal halide lamp luminaire – warning N/A

3.5 (3.3.8) Limitation for semi-luminaires N/A

3.5 (3.3.9) Power factor and supply current P

3.5 (3.3.10) Suitability for use indoors N/A

3.5 (3.3.11) Luminaires with remote control N/A

3.5 (3.3.12) Clip-mounted luminaire – warning N/A

3.5 (3.3.13) Specifications of protective shields N/A

3.5 (3.3.14) Symbol for nature of supply P

3.5 (3.3.15) Rated current of socket outlet N/A

3.5 (3.3.16) Rough service luminaire N/A

3.5 (3.3.17) Mounting instruction for type Y, type Z and some typeX attachments

Type Z P

3.5 (3.3.18) Non-ordinary luminaires with PVC cable N/A

3.5 (3.3.19) Protective conductor current in instruction ifapplicable

N/A

3.5 (3.3.20) Provided with information if not intended to bemounted within arm’s reach

N/A

3.5 (3.3.21) Non-replaceable and non-user replaceable lightsources information provided

non-user replaceable P

3.5 (3.3.22) Controllable luminaires, classification of insulationprovided

N/A

3.5 (3.4) Test with water P

Test with hexane P

Legible after test P

Label attached P

3.5 (-) Additional information in instruction leaflet P

a) Design attitude P

b) Weight P

c) Overall dimensions P

d) Maximum projected area if applicable N/A

e) Cross-sectional area of wires if applicable N/A

f) Suitability for indoors use P

g) Dimensions of the compartment P

h) Torque setting to be applied to bolts or screws P

Page 10: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 10 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

i) Maximum mounting height N/A

3.6 (4) CONSTRUCTION P

3.6 (4.2) Components replaceable without difficulty P

3.6 (4.3) Wireways smooth and free from sharp edges P

3.6 (4.4) Lampholders N/A

3.6 (4.4.1) Integral lampholder N/A

3.6 (4.4.2) Wiring connection N/A

3.6 (4.4.3) Lampholder for end-to-end mounting N/A

3.6 (4.4.4) Positioning N/A

- pressure test (N) .................................................. : —

After test the lampholder comply with relevantstandard sheets and show no damage

N/A

After test on single-capped lampholder thelampholder have not moved from its position andshow no permanent deformation

N/A

- bending test (N) ................................................... : —

After test the lampholder have not moved from itsposition and show no permanent deformation

N/A

3.6 (4.4.5) Peak pulse voltage N/A

3.6 (4.4.6) Centre contact N/A

3.6 (4.4.7) Parts in rough service luminaires resistant to tracking N/A

3.6 (4.4.8) Lamp connectors N/A

3.6 (4.4.9) Caps and bases correctly used N/A

3.6 (4.4.10) Light source for lampholder or connection accordingIEC 60061 not connected another way

N/A

3.6 (4.5) Starter holders N/A

Starter holder in luminaires other than class II N/A

Starter holder class II construction N/A

3.6 (4.6) Terminal blocks N/A

Tails N/A

Unsecured blocks N/A

3.6 (4.7) Terminals and supply connections N/A

3.6 (4.7.1) Contact to metal parts N/A

Page 11: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 11 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.6 (4.7.2) Test 8 mm live conductor N/A

Test 8 mm earth conductor N/A

3.6 (4.7.3) Terminals for supply conductors N/A

3.6 (4.7.3.1) Welded method and material N/A

- stranded or solid conductor N/A

- spot welding N/A

- welding between wires N/A

- Type Z attachment N/A

- mechanical test according to 15.8.2 N/A

- electrical test according to 15.9 N/A

- heat test according to 15.9.2.3 and 15.9.2.4 N/A

3.6 (4.7.4) Terminals other than supply connection N/A

3.6 (4.7.5) Heat-resistant wiring/sleeves N/A

3.6 (4.7.6) Multi-pole plug N/A

- test at 30 N N/A

3.6 (4.8) Switches N/A

- adequate rating N/A

- adequate fixing N/A

- polarized supply N/A

- compliance with IEC 61058-1 for electronicswitches

N/A

3.6 (4.9) Insulating lining and sleeves N/A

3.6 (4.9.1) Retainment N/A

Method of fixing ...................................................... : —

3.6 (4.9.2) Insulated linings and sleeves: N/A

Resistant to a temperature > 20 °C to the wiretemperature or

N/A

a) & c) Insulation resistance and electric strength N/A

b) Ageing test. Temperature (°C) ............................ : N/A

3.6 (4.10) Double or reinforced insulation N/A

3.6 (4.10.1) No contact, mounting surface – accessible metalparts – wiring of basic insulation

N/A

Safe installation fixed luminaires N/A

Page 12: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 12 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Capacitors and switches N/A

Interference suppression capacitors according to IEC60384-14

N/A

3.6 (4.10.2) Assembly gaps: N/A

- not coincidental N/A

- no straight access with test probe N/A

3.6 (4.10.3) Retainment of insulation: N/A

- fixed N/A

- unable to be replaced; luminaire inoperative N/A

- sleeves retained in position N/A

- lining in lampholder N/A

1.6 (4.10.4) Protective impedance device N/A

Double or reinforced insulation bridged byappropriate and at least two resistors or two Y2capacitors or one Y1 capacitor

N/A

Y1 or Y2 capacitors comply with IEC 60384-14 N/A

Resistors comply with test (a) in 14.1 ofIEC 60065

N/A

3.6 (4.11) Electrical connections and current-carrying parts P

3.6 (4.11.1) Contact pressure P

3.6 (4.11.2) Screws: N/A

- self-tapping screws N/A

- thread-cutting screws N/A

3.6 (4.11.3) Screw locking: P

- spring washer P

- rivets N/A

3.6 (4.11.4) Material of current-carrying parts P

3.6 (4.11.5) No contact to wood or mounting surface P

3.6 (4.11.6) Electro-mechanical contact systems N/A

3.6 (4.12) Screws and connections (mechanical) and glands P

3.6 (4.12.1) Screws not made of soft metal P

Screws of insulating material N/A

Torque test: torque (Nm); part ................................. : Screw of LED lens: 1,2Nm P

Torque test: torque (Nm); part ................................. : Screw fixed LED driver, 1.2Nm P

Page 13: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 13 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Torque test: torque (Nm); part ................................. : N/A

3.6 (4.12.2) Screws with diameter < 3 mm screwed into metal N/A

3.6 (4.12.4) Locked connections: N/A

- fixed arms; torque (Nm) ........................................ : N/A

- lampholder; torque (Nm) ....................................... : N/A

- push-button switches; torque 0,8 Nm .................... : N/A

3.6 (4.12.5) Screwed glands; force (Nm).................................... : Metal gland, 6,25Nm P

3.6 (4.13) Mechanical strength P

3.6 (4.13.1) Impact tests: P

- fragile parts; energy (Nm) ..................................... : N/A

- other parts; energy (Nm) ....................................... : Body and lens: 0,7Nm P

1) live parts P

2) linings P

3) protection P

4) covers P

3.6 (4.13.3) Straight test finger P

3.6 (4.13.4) Rough service luminaires N/A

- IP54 or higher N/A

a) fixed N/A

b) hand-held N/A

c) delivered with a stand N/A

d) for temporary installations and suitable formounting on a stand

N/A

3.6 (4.13.6) Tumbling barrel N/A

3.6 (4.14) Suspensions, fixings and means of adjusting P

3.6 (4.14.1) Mechanical load: P

A) four times the weight 3.182 kg x4=12.72Kg P

B) torque 2,5 Nm P

C) bracket arm; bending moment (Nm) ................... : P

D) load track-mounted luminaires N/A

E) clip-mounted luminaires, glass-shelve. Thickness(mm) ..................................................................... :

N/A

Metal rod. diameter (mm) ....................................... : N/A

Page 14: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 14 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Fixed luminaire or independent control gear withoutfixing devices

N/A

3.6 (4.14.2) Load to flexible cables N/A

Mass (kg) .............................................................. : —

Stress in conductors (N/mm²) ................................ : N/A

Mass (kg) of semi-luminaire ................................... : —

Bending moment (Nm) of semi-luminaire ............... : N/A

3.6 (4.14.3) Adjusting devices: N/A

- flexing test; number of cycles ................................ : N/A

- strands broken ..................................................... : N/A

- electric strength test afterwards N/A

3.6 (4.14.4) Telescopic tubes: cords not fixed to tube; no strain onconductors

N/A

3.6 (4.14.5) Guide pulleys N/A

3.6 (4.14.6) Strain on socket-outlets N/A

3.6 (4.15) Flammable materials P

- glow-wire test 650°C............................................. : See Test Table 3.15 (13.3.2) P

- spacing ≥30 mm N/A

- screen withstanding test of 13.3.1 N/A

- screen dimensions N/A

- no fiercely burning material P

- thermal protection N/A

- electronic circuits exempted N/A

3.6 (4.15.2) Luminaires made of thermoplastic material with lamp control gear N/A

a) construction N/A

b) temperature sensing control N/A

c) surface temperature N/A

3.6 (4.16) Luminaires for mounting on normally flammable surfaces P

No lamp control gear .............................................. : (compliance with Section 12) N/A

3.6 (4.16.1) Lamp control gear spacing: N/A

- spacing 35 mm N/A

- spacing 10 mm N/A

3.6 (4.16.2) Thermal protection: P

Page 15: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 15 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- in lamp control gear P

- external N/A

- fixed position N/A

- temperature marked lamp control gear N/A

3.6 (4.16.3) Design to satisfy the test of 12.6 (see clause 12.6) N/A

3.6 (4.17) Drain holes N/A

Clearance at least 5 mm N/A

3.6 (4.18) Resistance to corrosion N/A

3.6 (4.18.1) - rust-resistance N/A

3.6 (4.18.2) - season cracking in copper N/A

3.6 (4.18.3) - corrosion of aluminium N/A

3.6 (4.19) Igniters compatible with ballast N/A

3.6 (4.20) Rough service vibration N/A

3.6 (4.21) Protective shield N/A

3.6 (4.21.1) Shield fitted if tungsten halogen lamps or metalhalide lamps

N/A

Shield of glass if tungsten halogen lamps N/A

3.6 (4.21.2) Particles from a shattering lamp not impair safety N/A

3.6 (4.21.3) No direct path N/A

3.6 (4.21.4) Impact test on shield N/A

Glow-wire test on lamp compartment ...................... : See Test Table 3.15 (13.3.2) N/A

3.6 (4.22) Attachments to lamps not cause overheating ordamage

N/A

3.6 (4.23) Semi-luminaires comply Class II N/A

3.6 (4.24) Photobiological hazards P

3.6 (4.24.1) No excessive UV radiation if tungsten halogen lampsand metal halide lamps (Annex P)

N/A

3.6 (4.24.2) Retinal blue light hazard P

Class of risk group assessed according to IEC/TR62778 ................................................................... :

RG2 —

Luminaires with Ethr : P

a) Fixed luminaires P

- distance x m, borderline between RG1 and RG2... : 0.67m P

Page 16: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 16 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- marking and instruction according 3.2.23 P

b) Portable and handheld luminaires N/A

- marking according 3.2.23 if RG1 exceeded at 200mm according to IEC/TR 62778

N/A

Portable luminaires for children IEC 60598-2-10 andMains socket outlet nightlights IEC 60598-2-12 notexceed RG1 at 200 mm according to IEC/62778

N/A

3.6 (4.25) Mechanical hazard P

No sharp point or edges P

3.6 (4.26) Short-circuit protection N/A

3.6 (4.26.1) Adequate means of uninsulated accessible SELVparts

N/A

3.6 (4.26.2) Short-circuit test with test chain according 4.26.3 N/A

Test chain not melt through N/A

Test sample not exceed values of Table 12.1 and12.2

N/A

3.6 (4.27) Terminal blocks with integrated screwless earthing contacts N/A

Test according Annex V N/A

Pull test of terminal fixing (20 N) N/A

After test, resistance < 0,05 Ω N/A

Pull test of mechanical connection (50 N) N/A

After test, resistance < 0,05 Ω N/A

Voltage drop test, resistance < 0,05 Ω N/A

3.6 (4.28) Fixing of thermal sensing control N/A

Not plug-in or easily replaceable type N/A

Reliably kept in position N/A

No adhesive fixing if UV radiations from a lamp candegrade the fixing

N/A

Not outside the luminaire enclosure N/A

Test of adhesive fixing: N/A

Max. temperature on adhesive material (°C) ........... : —

100 cycles between t min and t max N/A

Temperature sensing control still in position N/A

3.6 (4.29) Luminaires with non-replaceable light source N/A

Page 17: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 17 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Not possible to replace light source N/A

Live part not accessible after parts have beenopened by hand or tools

N/A

3.6 (4.30) Luminaires with non-user replaceable light source P

If protective cover provide protection against electric shock and marked with “caution,electric shock risk” symbol:

P

Minimum two fixing means P

3.6 (4.31) Insulation between circuits P

Circuits insulated from LV supply fulfil requirementsaccording 4.31.1 – 4.31.3

P

Controllable luminaires requiring same level ofinsulation for all components, the insulation betweencontrol terminals and LV supply fulfil requirementsaccording 4.31.1 – 4.31.3

N/A

3.6 (4.31.1) SELV circuits N/A

Used SELV source N/A

Voltage ≤ ELV N/A

Insulating of SELV circuits from LV supply N/A

Insulating of SELV circuits from other non SELVcircuits

N/A

Insulating of SELV circuits from FELV N/A

Insulating of SELV circuits from other SELV circuits N/A

SELV circuits insulated from accessible partsaccording Table X.1

N/A

Plugs not able to enter socket-outlets of other voltagesystems

N/A

Socket outlets does not admit plugs of other voltagesystems

N/A

Plugs and socket-outlets does not have protectiveconductor contact

N/A

3.6 (4.31.2) FELV circuits N/A

Used FELV source N/A

Voltage ≤ ELV N/A

Insulating of FELV circuits from LV supply N/A

FELV circuits insulated from accessible partsaccording Table X.1

N/A

Page 18: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 18 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Plugs not able to enter socket-outlets of other voltagesystems

N/A

Socket outlets does not admit plugs of other voltagesystems

N/A

Socket-outlets does not have protective conductorcontact

N/A

3.6 (4.31.3) Other circuits P

Other circuits insulated from accessible partsaccording Table X.1

P

Class II construction with equipotential bonding for protection against indirect contactswith live parts:

N/A

- conductive parts are connected together N/A

- test according 7.2.3 of above N/A

- conductive part not cause an electric shock in caseof an insulation fault

N/A

- equipotential bonding in master/slave applications N/A

- master luminaire provided with terminal foraccessible conductive parts of slave luminaires

N/A

- slave luminaire constructed as class I N/A

3.6 (4.32) Overvoltage protective devices N/A

Comply with IEC 61643-11 N/A

External to controlgear and connected to earth: N/A

- only in fixed luminaires N/A

- only connected to protective earth N/A

3.6.1 (-) At least IP X3 or X5 respectively. IP ................... : IP 66 P

Column-integrated luminaires: N/A

- parts below 2,5 m. IP ....................................... : N/A

- parts above 2,5 m. IP ...................................... : N/A

3.6.2 (-) Suspension on span wires N/A

3.6.3 (-) Means for attaching the luminaire or external parts toits support appropriate to the weight

P

3.6.3.1 (-) Static load test P

- drag coefficient ................................................. : 1,2 P

- loaded area (m²) ............................................... : 0,09 P

- used load (N).................................................... : 133.7 P

Page 19: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 19 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- measured deformation (cm/m) ......................... : <2 P

- no rotation P

3.6.4 (-) Adjustable lampholders N/A

3.6.5 (-) Luminaires installed above 5 m, glass covers shall be: N/A

a) glass that fractures into small pieces (testaccording to 3.6.5.1), or

N/A

b) glass having a high impact shock resistance (testaccording to 3.6.5.2), or

N/A

c) protected by any means to retain glass fragments N/A

For tunnel luminaires 3.6.5.1 apply N/A

Method of protection declared by the manufacturer N/A

3.6.5.1 (-) Protection by the use of glass that fractures into small pieces N/A

- number of particles is more than 40 .................. : N/A

3.6.5.2 (-) Protection by the use of high impact resistant glass N/A

3.6.5.2.1 (-) Glass covers have high mechanical strength N/A

Test according IEC 62262 with test apparatusaccording IEC 60068-2-75 with impact energy of 5Jon preconditioned sample

N/A

3.6.5.2.2 (-) Glass covers not break into large pieces N/A

- test according 3.6.5.1, number of particles is morethan 20 ............................................................... :

N/A

3.6.6 (-) Connection compartment of column-integrated luminaire N/A

- provides adequate space N/A

- means for attachment N/A

- means for attachment of metal corrosion-resistant N/A

3.6.7 (-) Compliance with ISO standard or other ............... : N/A

3.6.8 (-) Doors of column-integrated luminaires: N/A

- corrosion-resistant N/A

- opening only possible for an authorized person N/A

- impact test 5 Nm N/A

- sample show no damage N/A

3.6.9 (-) Column-integrated luminaire: N/A

- dimension of the cable entry slot (mm).............. : N/A

- cable path from the slot to the connectioncompartment (mm) ............................................ :

N/A

Page 20: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 20 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- cable path free from obstruction that might causeabrasion of the cable

N/A

3.7 (11) CREEPAGE DISTANCES AND CLEARANCES

3.7 (11.2) Creepage distances and clearances ....................... : See Table 3.7 (11.2)

Impulse withstand category (Normal category II)(Category III Annex U, Table U.1)

Category II Category III

3.8 (7) PROVISION FOR EARTHING P

3.8 (7.2.1+ 7.2.3)

Accessible metal parts P

Metal parts in contact with supporting surface P

Resistance < 0,5 Ω ................................................. : Max. 0,1 Ω P

Self-tapping screws used N/A

Thread-forming screws P

Thread-forming screw used in a grove N/A

Earth makes contact first N/A

Terminal blocks with integrated screwless earthingcontacts tested according Annex V

N/A

Protective earthing of the luminaire not via built-incontrol gear

P

3.8 (7.2.2+ 7.2.3)

Earth continuity in joints, etc. N/A

3.8 (7.2.4) Locking of clamping means P

Compliance with 4.7.3 P

Terminal blocks with integrated screwless earthingcontacts tested according Annex V

N/A

3.8 (7.2.5) Earth terminal integral part of connector socket N/A

3.8 (7.2.6) Earth terminal adjacent to mains terminals P

3.8 (7.2.7) Electrolytic corrosion of the earth terminal P

3.8 (7.2.8) Material of earth terminal P

Contact surface bare metal P

3.8 (7.2.10) Class II luminaire for looping-in N/A

Double or reinforced insulation to functional earth N/A

3.8 (7.2.11) Earthing core coloured green-yellow P

Length of earth conductor P

Page 21: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 21 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.8.1 (-) Attachment prevented from rotation N/A

3.9 (14) SCREW TERMINALS N/A

Separately approved; component list ...................... : (see Annex 1) N/A

Part of the luminaire ............................................... : (see Annex 3) N/A

3.9 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS N/A

Separately approved; component list ...................... : (see Annex 1) N/A

Part of the luminaire ............................................... : (see Annex 4) N/A

3.10 (5) EXTERNAL AND INTERNAL WIRING P

3.10 (5.2) Supply connection and external wiring P

3.10 (5.2.1) Means of connection............................................... : Power cord P

Outdoor luminaire has not PVC insulated externalwiring if not class III or SELV ≤ 25 V a.c./60 V d.c. orprotected from outdoor environment

N/A

3.10 (5.2.2) Type of cable .......................................................... : H05RN-F P

Nominal cross-sectional area (mm²)........................ : 3x 1,0 P

Cables equal to IEC 60227 or IEC 60245 IEC60245 P

3.10 (5.2.3) Type of attachment, X, Y or Z Z P

3.10 (5.2.5) Type Z not connected to screws P

3.10 (5.2.6) Cable entries: P

- suitable for introduction P

- adequate degree of protection P

3.10 (5.2.7) Cable entries through rigid material have roundededges

P

3.10 (5.2.8) Insulating bushings: P

- suitably fixed P

- material in bushings P

- material not likely to deteriorate P

- tubes or guards made of insulating material P

3.10 (5.2.9) Locking of screwed bushings N/A

3.10(5.2.10)

Cord anchorage: P

Page 22: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 22 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- covering protected from abrasion P

- clear how to be effective P

- no mechanical or thermal stress P

- no tying of cables into knots etc. P

- insulating material or lining P

3.10(5.2.10.1)

Cord anchorage for type X attachment: N/A

a) at least one part fixed N/A

b) types of cable N/A

c) no damaging of the cable N/A

d) whole cable can be mounted N/A

e) no touching of clamping screws N/A

f) metal screw not directly on cable N/A

g) replacement without special tool N/A

Glands not used as anchorage N/A

Labyrinth type anchorages N/A

3.10(5.2.10.2)

Adequate cord anchorage for type Y and type Zattachment

Z P

3.10(5.2.10.3)

Tests: P

- impossible to push cable; unsafe P

- pull test: 25 times; pull (N) .................................... : 60 P

- torque test: torque (Nm)........................................ : 0,25 P

- displacement ≤ 2 mm P

- no movement of conductors P

- no damage of cable or cord P

- function independent of electrical connection P

3.10(5.2.11)

External wiring passing into luminaire P

3.10(5.2.12)

Looping-in terminals N/A

3.10(5.2.13)

Wire ends not tinned N/A

Wire ends tinned: no cold flow P

Page 23: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 23 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.10(5.2.14)

Mains plug same protection N/A

Class III luminaire plug N/A

No unsafe compatibility N/A

3.10(5.2.16)

Appliance inlets (IEC 60320) N/A

Installation couplers (IEC 61535) N/A

Other appliance inlet or connector according relevantIEC standard

N/A

3.10(5.2.17)

No standardized interconnecting cables properlyassembled

N/A

3.10(5.2.18)

Used plug in accordance with N/A

- IEC 60083 N/A

- other standard N/A

3.10 (5.3) Internal wiring P

3.10 (5.3.1) Internal wiring of suitable size and type P

Through wiring N/A

- not delivered/ mounting instruction N/A

- factory assembled N/A

- socket outlet loaded (A) ........................................ : N/A

- temperatures ........................................................ : (see Annex 2) N/A

Green-yellow for earth only P

3.10(5.3.1.1)

Internal wiring connected directly to fixed wiring N/A

Cross-sectional area (mm²) .................................... : N/A

Insulation thickness N/A

Extra insulation added where necessary N/A

3.10(5.3.1.2)

Internal wiring connected to fixed wiring via internal current-limiting device P

Adequate cross-sectional area and insulationthickness

P

3.10(5.3.1.3)

Double or reinforced insulation for class II N/A

3.10(5.3.1.4)

Conductors without insulation N/A

Page 24: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 24 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.10(5.3.1.5)

SELV current-carrying parts N/A

3.10(5.3.1.6)

Insulation thickness other than PVC or rubber N/A

3.10 (5.3.2) Sharp edges etc. P

No moving parts of switches etc. N/A

Joints, raising/lowering devices N/A

Telescopic tubes etc. N/A

No twisting over 360° P

3.10 (5.3.3) Insulating bushings: N/A

- suitable fixed N/A

- material in bushings N/A

- material not likely to deteriorate N/A

- cables with protective sheath N/A

3.10 (5.3.4) Joints and junctions effectively insulated N/A

3.10 (5.3.5) Strain on internal wiring P

3.10 (5.3.6) Wire carriers N/A

3.10 (5.3.7) Wire ends not tinned N/A

Wire ends tinned: no cold flow P

3.10.1 (-) Cord anchorage if applicable P

- pull test: 25 times; pull (N) ................................ : 60 P

- torque test: torque (Nm).................................... : 0,25 P

3.11 (8) PROTECTION AGAINST ELECTRIC SHOCK P

3.11 (8.2.1) Live parts not accessible P

Basic insulated parts not used on the outer surfacewithout appropriate protection

P

Basic insulated parts not accessible with standardtest finger on portable, settable and adjustableluminaires

N/A

Basic insulated parts not accessible with Ø 50 mmprobe from outside, other types of luminaires

P

Lamp and starterholders in portable and adjustableluminaires comply with double or reinforcedinsulation requirements

N/A

Page 25: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 25 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Basic insulation only accessible under lamp or starterreplacement

N/A

Protection in any position P

Double-ended tungsten filament lamp N/A

Insulation lacquer not reliable N/A

Double-ended high pressure discharge lamp N/A

Relevant warning according to 3.2.18 fitted to theluminaire

N/A

3.11 (8.2.2) Portable luminaire adjusted in most unfavourableposition

N/A

3.11(8.2.3.a)

Class II luminaire: N/A

- basic insulated metal parts not accessible duringstarter or lamp replacement

N/A

- basic insulation not accessible other than duringstarter or lamp replacement

N/A

- glass protective shields not used as supplementaryinsulation

N/A

3.11(8.2.3.b)

BC lampholder of metal in class I luminaires shall beearthed

N/A

3.11(8.2.3.c)

SELV circuits with exposed current carrying parts: N/A

Ordinary luminaire: N/A

- touch current ....................................................... : N/A

- no-load voltage ..................................................... : N/A

Other than ordinary luminaire: N/A

- nominal voltage ................................................... : N/A

3.11 (8.2.4) Portable luminaire have protection independent ofsupporting surface

N/A

3.11 (8.2.5) Compliance with the standard test finger or relevantprobe

P

3.11 (8.2.6) Covers reliably secured P

3.11 (8.2.7) Discharging of capacitors ≥ 0,5 µF P

Portable plug connected luminaire with capacitor N/A

Other plug connected luminaire with capacitor N/A

Discharge device on or within capacitor N/A

Page 26: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 26 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Discharge device mounted separately N/A

3.12 (12) ENDURANCE TEST AND THERMAL TEST P

3.12.2 (-) If IP > IP 20 relevant test of (12.4), (12.5) and (12.6) after (9.2) before (9.3) specified in3.13

3.12 (12.3) Endurance test: P

- mounting-position ................................................. : As normal use

- test temperature (°C) ............................................ : 45 + 10 =55

- total duration (h) ................................................... : 240

- supply voltage: Un factor; calculated voltage (V) ... : 240 x 1,1 =264

- lamp used ............................................................ : LED

3.12(12.3.2)

After endurance test: P

- no part unserviceable P

- luminaire not unsafe P

- no damage to track system N/A

- marking legible P

- no cracks, deformation etc. P

3.12 (12.4) Thermal test (normal operation) (see Annex 2) P

3.12 (12.5) Thermal test (abnormal operation) (see Annex 2) P

3.12 (12.6) Thermal test (failed lamp control gear condition): N/A

3.12(12.6.1)

Through wiring or looping-in wiring loaded by acurrent of (A) ......................................................... :

- case of abnormal conditions ................................. :

- electronic lamp control gear P

- measured winding temperature (°C): at 1,1 Un .... :

- measured mounting surface temperature (°C) at1,1 Un .................................................................... :

N/A

- calculated mounting surface temperature (°C) ..... : N/A

- track-mounted luminaires N/A

3.12(12.6.2)

Temperature sensing control N/A

- case of abnormal conditions ................................. :

- thermal link N/A

Page 27: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 27 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- manual reset cut-out N/A

- auto reset cut-out N/A

- measured mounting surface temperature (°C)....... : N/A

- track-mounted luminaires N/A

3.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires): N/A

3.12(12.7.1)

Luminaire without temperature sensing control N/A

3.12(12.7.1.1)

Luminaire with fluorescent lamp ≤ 70W N/A

Test method 12.7.1.1 or Annex W .......................... :

Test according to 12.7.1.1: N/A

- case of abnormal conditions ................................. :

- Ballast failure at supply voltage (V) ...................... :

- Components retained in place after the test N/A

- Test with standard test finger after the test N/A

Test according to Annex W: N/A

- case of abnormal conditions ................................. :

- measured winding temperature (°C): at 1,1 Un ..... :

- measured temperature of fixing point/exposed part(°C): at 1,1 Un ........................................................ :

- calculated temperature of fixing point/exposed part(°C) ........................................................................ :

Ball-pressure test................................................ : See Table 3.15 (13.2.1) N/A

3.12(12.7.1.2)

Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA N/A

- case of abnormal conditions ................................. :

- measured winding temperature (°C): at 1,1 Un ..... :

- measured temperature of fixing point/exposed part(°C): at 1,1 Un ........................................................ :

- calculated temperature of fixing point/exposed part(°C) ........................................................................ :

Ball-pressure test.................................................... : See Table 3.15 (13.2.1) N/A

3.12(12.7.1.3)

Luminaire with short circuit proof transformers≤ 10 VA

N/A

- case of abnormal conditions ................................. :

Page 28: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 28 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- Components retained in place after the test N/A

- Test with standard test finger after the test N/A

3.12(12.7.2)

Luminaire with temperature sensing control N/A

- thermal link ........................................................... : Yes No

- manual reset cut-out ............................................. : Yes No

- auto reset cut-out ................................................. : Yes No

- case of abnormal conditions ................................. :

- highest measured temperature of fixing point/exposed part (°C): .................................................. :

Ball-pressure test:................................................... : See Table 3.15 (13.2.1) N/A

3.12.1 (-) Temperature reduction if for outdoor use only P

3.12.2 (-) (See above)

3.12.3 (-) Glass covers used within the thermal limits declaredby the glass manufacturer

N/A

3.13 (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE P

3.13.1 (-) If IP > IP 20 the order of tests as specified in clause 3.12 P

3.13 (9.2) Tests for ingress of dust, solid objects and moisture:

- classification according to IP ................................. : IP 66

- mounting position during test ................................ : As normal use

- fixing screws tightened; torque (Nm) ..................... :

- tests according to clauses .................................... : 9.2.2 & 9.2.6

- electric strength test afterwards P

a) no deposit in dust-proof luminaire N/A

b) no talcum in dust-tight luminaire P

c) no trace of water on current-carrying parts or oninsulation where it could become a hazard

P

d) i) For luminaires without drain holes – no waterentry

P

d) ii) For luminaires with drain holes – no hazardouswater entry

N/A

e) no water in watertight luminaire N/A

f) no contact with live parts (IP 2X) N/A

Page 29: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 29 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

f) no entry into enclosure (IP 3X and IP 4X) N/A

f) no contact with live parts (IP3X and IP4X) N/A

g) no trace of water on part of lamp requiringprotection from splashing water

N/A

h) no damage of protective shield or glass envelope N/A

3.13 (9.3) Humidity test 48 h P

3.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P

3.14(10.2.1)

Insulation resistance test P

Cable or cord covered by metal foil or replaced by ametal rod of mm Ø ................................................. :

Insulation resistance (MΩ) ...................................... :

SELV N/A

- between current-carrying parts of different polarity : N/A

- between current-carrying parts and mountingsurface ................................................................... :

N/A

- between current-carrying parts and metal parts ofthe luminaire ........................................................... :

N/A

- between the outer surface of a flexible cord or cablewhere it is clamped in a cord anchorage andaccessible metal parts ............................................ :

N/A

- Insulation bushings as described in Section 5 ...... : N/A

Other than SELV P

- between live parts of different polarity ................... : >100 MΩ P

- between live parts and mounting surface .............. : >100 MΩ P

- between live parts and metal parts........................ : >100 MΩ P

- between live parts of different polarity throughaction of a switch .................................................... :

N/A

- between the outer surface of a flexible cord or cablewhere it is clamped in a cord anchorage andaccessible metal parts ............................................ :

>100 MΩ P

- Insulation bushings as described in Section 5 ......: N/A

3.14(10.2.2)

Electric strength test P

Dummy lamp N/A

Page 30: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 30 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Luminaires with ignitors after 24 h test N/A

Luminaires with manual ignitors N/A

Test voltage (V) ...................................................... : P

SELV N/A

- between current-carrying parts of different polarity : N/A

- between current-carrying parts and mountingsurface ................................................................... :

N/A

- between current-carrying parts and metal parts ofthe luminaire ........................................................... :

N/A

- between the outer surface of a flexible cord or cablewhere it is clamped in a cord anchorage andaccessible metal parts ............................................ :

N/A

- Insulation bushings as described in Section 5 ...... : N/A

Other than SELV P

- between live parts of different polarity ................... : 1480V P

- between live parts and mounting surface .............. : 1480V P

- between live parts and metal parts........................ : 1480V P

- between live parts of different polarity throughaction of a switch .................................................... :

N/A

- between the outer surface of a flexible cord or cablewhere it is clamped in a cord anchorage andaccessible metal parts ............................................ :

1480V P

- Insulation bushings as described in Section 5 ...... : N/A

3.14 (10.3) Touch current or protective conductor current (mA) . : Protective conductor currentMax. 0.165mA (limit: 3.5mA);

Touch current Max.0.061mA(limit: 0.7mA)

P

3.15 (13) RESISTANCE TO HEAT, FIRE AND TRACKING P

3.15(13.2.1)

Ball-pressure test....................................................: See Test Table 3.15 (13.2.1) P

3.15(13.3.1)

Needle-flame test (10 s) .........................................: See Test Table 3.15 (13.3.1) N/A

3.15(13.3.2)

Glow-wire test (650°C) ............................................: See Test Table 3.15 (13.3.2) P

3.15 (13.4) Proof tracking test (IEC 60112) ...............................: See Test Table 3.15 (13.4) N/A

Page 31: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 31 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.7 (11.2) TABLE: Creepage distances and clearances P

Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages P

Applicable part of IEC 60598-1 Table 11.1* and 11.2* P

Insulationtype **

Measuredclearance

Required Measuredcreepage

Required

clearance *Table creepage *Table

Distance 1: B >3.5 1.5 11.1 >3.5 2.5 11.1

Working voltage (V) ................................................................... : 250

PTI ............................................................................................ : < 600 > 600

Pulse voltage if applicable (kV) ................................................. : 2.5

Supplementary information: Between different two polarities.

Distance 2: B 8.7 1.5 11.1 8.7 2.5 11.1

Working voltage (V) ................................................................... : 250

PTI ............................................................................................ : < 600 > 600

Pulse voltage if applicable (kV) ................................................. : 2.5

Supplementary information: Between live parts and metal enclosure.

Page 32: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 32 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.15(13.2.1)

TABLE: Ball Pressure Test of ThermoplasticsP

Allowed impression diameter (mm) ................... : <2mm

Object/ Part No./ Material Manufacturer/trademark

Test temperature (°C) Impression diameter (mm)

LED lens 99+25 =124 1.1

Supplementary information:

3.15(13.3.1)

TABLE: Needle-flame test (IEC 60695-11-5) N/A

Object/ Part No./Material

Manufacturer/trademark

Duration ofapplication of test

flame (ta); (s)

Ignition ofspecified layer

Yes/No

Duration ofburning (tb)

(s)Verdict

-- -- -- -- -- --

Supplementary information:

3.15(13.3.2)

TABLE: Glow-wire test (IEC 60695-2-11)P

Glow wire temperature ........................................ : 650°C

Object/ Part No./Material

Manufacturer/trademark

Duration ofapplication of test

flame (ta); (s)

Ignition ofspecified layer

Yes/No

Duration ofburning (tb)

(s)Verdict

LED lens 30 NO 0 PASS

Any flame or glowing of the sample extinguished within 30 s of withdrawing the glow-wire, andany burning or molten drop did not ignite the underlying parts (Yes/No) ..................................... :

Yes

Supplementary information:

3.15 (13.4) TABLE: Proof tracking test (IEC 60112) N/A

Test voltage PTI .................................................. : 175 V

Object/ Part No./ Material Manufacturer/trademark

Withstand 50 drops without failure on threeplaces or on three specimens

Verdict

-- -- -- -- -- --

Supplementary information:

Page 33: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 33 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

ANNEX 1 TABLE: Critical components information P

Object / part No. CodeManufacturer/trademark

Type / model Technical data StandardMark(s) ofconformity1)

1. LEDs (forall models)

B CREE XTEAWT-00-COPP-AE400BGE7

VF=2.85V,IF=DC1.5A,CCT:3000K

IEC 60598-1 Test withappliance

XTEAWT-00-COPPAE400BJE5

VF=2.85V,IF=DC1.5A,CCT:4000K

XPGBWT-B1-COPP-A0JE2KE40

VF=2.85V,IF=DC1.5A,CCT:5700K

2. PCB ofLEDmodule

B ZHUHAI JINGLIHUAPCB CO LTD

JLH94-V0L Metal base, 94V-0,90 -- UL and test with

appliance

B WODEELECTRONICSTECHNOLOGY(ZHUHAI) CO LTD

WD-16 Metal base, 94V-0,130 -- UL and test with

appliance

3. Lens B TEIJINPOLYCARBONATESINGAPORE PTELTD

L-1225Z(#1)(f1) HB -- UL and test withappliance

4. LED driverwithexternalrubbercable1.0~1.5mm2

B INVENTRONICS(HANGZHOU), INC.

EUP150S070SV

(for LED SL-PQ100W, LED SL-PQ 120W)

Input: 100-240V,50/60Hz; 1.65A

Output: DC700mA,117-333V,Independent, IP65,class I, 150W

Ta: 50°C, tc: 90°C

IEC 61347-2-13

IEC 61347-1

TUV RheinlandR50354744

B INVENTRONICS(HANGZHOU), INC.

EUP150S105SV

(for LED SL-PQ150W)

Input: 100-240V,50/60Hz; 1.65A

Output: DC1050mA,75-214V,Independent, IP67,class I, 150W

Ta: 50°C, tc: 90°C

IEC 61347-2-13

IEC 61347-1

TUV RheinlandR50354744

5. Gland C Kunshan LanjiangElectrical TechnologyCo., Ltd

MGMG 12x1.5 IEC 60598-1 Test with

appliance

Page 34: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 34 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Supplementary information:1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.

The codes above have the following meaning:

A - The component is replaceable with another one, also certified, with equivalent characteristics

B - The component is replaceable if authorised by the test house

C - Integrated component tested together with the appliance

D - Alternative component

ANNEX 2 TABLE: Temperature measurements, thermal tests of Section 12 P

Type reference ..................................................... : LED SL-PQ 150W

Lamp used............................................................ : LED

Lamp control gear used ........................................ : EUP-150S105SV

Mounting position of luminaire ............................... : As normal use

Supply wattage (W) .............................................. : Test 2: 149.6; test 4: 0.86

Supply current (A) ................................................. : Test 2: 0.595; test 4: 0.053

Calculated power factor ........................................ : 0.998

Table: measured temperatures corrected for ta = 45 °C: P

- abnormal operating mode ................................... : 1. Short circuit one LED: inputpower: 149.11W;

2. Open circuit one LED: inputpower: 149.4W;

3. Short circuit output of LEDdriver: lamp turn off, inputpower: 0.86W;

4. Open circuit output of LEDdriver: lamp turn off, inputpower: 0.13W.

- test 1: rated voltage ............................................ :

- test 2: 1,06 times rated voltage or 1,05 times ratedwattage................................................................. :

240V x1.05=254.4V

- test 3: Load on wiring to socket-outlet, 1,06 timesvoltage or 1,05 times wattage ............................... :

- test 4: 1,1 times rated voltage or 1,05 times ratedwattage................................................................. :

240V x1.1=264V

Through wiring or looping-in wiring loaded by acurrent of A during the test ................................... :

Page 35: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 35 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Temperature measurements, (°C)

Part AmbientClause 12.4 – normal Clause 12.5 – abnormal

test 1 test 2 test 3 limit test 4 limit

LED PCBmodule

-- 59.2 -- 90 -- --

Point near LEDdiode

-- 82.2 -- Ref. -- --

Internal wire toLED PCB

-- 74.6 -- 90 -- --

Tc of LED driver -- 89.4 -- 90 84.2 100

Input wire toLED driver

-- 71.1 -- 90 -- --

Lens(innersurface)

-- 98.8 -- Material test -- --

Metalenclosure(nearLED module)

-- 69.1 -- Ref. -- --

Metalenclosure(nearLED driver)

-- 79.8 -- Ref. -- --

Mountingsurface

-- 76.2 -- 90 75.6 130

Light surface0.1m

-- 57.8 -- 90 -- --

Supplementary information:

1. For abnormal condition, chose the most onerous condition to measure.

2. For test data mentioned in above table, 10 °C has be deducted from the temperatures measured onthe luminaire in the test enclosure to allow for the effects of natural air movement which occur in theworking environment of the luminaire.

Type reference ..................................................... : LED SL-PQ 100W-GY-GP

Lamp used............................................................ : LED

Lamp control gear used ........................................ : EUP-150S070SV

Mounting position of luminaire ............................... : As normal use

Supply wattage (W) .............................................. : 108.7

Supply current (A) ................................................. : 0.436

Calculated power factor ........................................ : 0.978

Page 36: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 36 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Table: measured temperatures corrected for ta = 45 °C: P

- abnormal operating mode ................................... :

- test 1: rated voltage ............................................ :

- test 2: 1,06 times rated voltage or 1,05 times ratedwattage................................................................. :

240V x1.05=254.4V

- test 3: Load on wiring to socket-outlet, 1,06 timesvoltage or 1,05 times wattage ............................... :

- test 4: 1,1 times rated voltage or 1,05 times ratedwattage................................................................. :

Through wiring or looping-in wiring loaded by acurrent of A during the test ................................... :

Temperature measurements, (°C)

Part AmbientClause 12.4 – normal Clause 12.5 – abnormal

test 1 test 2 test 3 limit test 4 limit

LED PCBmodule

-- 53.5 -- 90 -- --

Internal wire toLED PCB

-- 73.4 -- 90 -- --

Tc of LED driver -- 84.9 -- 90 -- --

Supplementary information:

1. For test data mentioned in above table, 10 °C has be deducted from the temperatures measured onthe luminaire in the test enclosure to allow for the effects of natural air movement which occur in theworking environment of the luminaire.

Page 37: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 37 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

ANNEX 3 Screw terminals (part of the luminaire) N/A

(14) SCREW TERMINALS N/A

(14.2) Type of terminal ......................................................:

Rated current (A) ....................................................:

(14.3.2.1) One or more conductors N/A

(14.3.2.2) Special preparation N/A

(14.3.2.3) Terminal size N/A

Cross-sectional area (mm²) ....................................:

(14.3.3) Conductor space (mm) ...........................................: N/A

(14.4) Mechanical tests N/A

(14.4.1) Minimum distance N/A

(14.4.2) Cannot slip out N/A

(14.4.3) Special preparation N/A

(14.4.4) Nominal diameter of thread (metric ISO thread) ......: M N/A

External wiring N/A

No soft metal N/A

(14.4.5) Corrosion N/A

(14.4.6) Nominal diameter of thread (mm) ............................: N/A

Torque (Nm) ...........................................................: N/A

(14.4.7) Between metal surfaces N/A

Lug terminal N/A

Mantle terminal N/A

Pull test; pull (N) .....................................................: N/A

(14.4.8) Without undue damage N/A

ANNEX 4 Screwless terminals (part of the luminaire) N/A

(15) SCREWLESS TERMINALS N/A

(15.2) Type of terminal ......................................................:

Rated current (A) ....................................................:

(15.3.1) Material N/A

Page 38: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 38 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

(15.3.2) Clamping N/A

(15.3.3) Stop N/A

(15.3.4) Unprepared conductors N/A

(15.3.5) Pressure on insulating material N/A

(15.3.6) Clear connection method N/A

(15.3.7) Clamping independently N/A

(15.3.8) Fixed in position N/A

(15.3.10) Conductor size N/A

Type of conductor N/A

(15.5.1) Terminals internal wiring N/A

(15.5.1.1) Pull test spring-type terminals (4 N, 4 samples).......: N/A

(15.5.1.2) Pull test pin or tab terminals (4 N, 4 samples) .........: N/A

Insertion force not exceeding 50 N N/A

(15.5.1.2) Permanent connections: pull-off test (20 N) N/A

(15.5.2) Electrical tests N/A

Voltage drop (mV) after 1 h (4 samples)..................: N/A

Voltage drop of two inseparable joints N/A

Number of cycles:

Voltage drop (mV) after 10th alt. 25th cycle(4 samples) ............................................................:

N/A

Voltage drop (mV) after 50th alt. 100th cycle(4 samples) ............................................................:

N/A

After ageing, voltage drop (mV) after 10th alt.25th cycle (4 samples) ............................................:

N/A

After ageing, voltage drop (mV) after 50th alt.100th cycle (4 samples) ..........................................:

N/A

(15.6) Terminals external wiring N/A

Terminal size and rating N/A

(15.6.2.1) Pull test spring-type terminals or welded connections(4 samples); pull (N) ..............................................:

N/A

Pull test pin or tab terminals (4 samples);pull (N) ..................................................................:

N/A

Page 39: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

IEC 60598-2-3

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 39 of 39

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

(15.6.3.1) TABLE: Contact resistance test N/A

Voltage drop (mV) after 1 h

terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)

Voltage drop of two inseparable joints N/A

Voltage drop after 10th alt. 25th cycle N/A

Max. allowed voltage drop (mV) ................ :

terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)

Voltage drop after 50th alt. 100th cycle N/A

Max. allowed voltage drop (mV) ................ :

terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)

Continued ageing: voltage drop after 10th alt. 25th cycle N/A

Max. allowed voltage drop (mV) ................ :

terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)

Continued ageing: voltage drop after 50th alt. 100th cycle V

Max. allowed voltage drop (mV) ................ :

terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)

Supplementary information:

Page 40: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 1 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

4 GENERAL REQUIREMENTS

4.4 Integral modules tested assembled in the luminaire P

4.5 Independent modules complies with requirements inIEC 60598-1

N/A

5 GENERAL TEST REQUIREMENTS

5.5 SELV-operated LED modules comply with Annex I ofIEC 61347-2-13

(see Annex 1) N/A

General conditions for tests in Annex A (see Annex A) N/A

6 CLASSIFICATION

Built-in module ....................................................... : Yes No

Independent module ............................................... : Yes No

Integral module ...................................................... : Yes No

For Integral module; Note to 1.2.1 in IEC 60598-1applies.

7 MARKING

7.1 Mandatory markings for built-in or independent modules N/A

a) mark of origin N/A

b) model number, type reference N/A

c1) constant voltage module; rated supply voltage andsupply frequency

N/A

c2) constant current module; rated supply current andsupply frequency

N/A

d) nominal power N/A

e) indication of connections, wiring diagram N/A

f) value of tc and place on the module N/A

g) Ethr if required N/A

h) symbol for built-in modules N/A

i) heat transfer temperature td N/A

j) power for heat-conduction Pd N/A

k) working voltage for insulation N/A

7.2 Location of marking N/A

- marking of a), b), c) and f) on the modules N/A

Page 41: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 2 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- marking of d), e), g), h), i) and j) on the modules ordata sheet

N/A

- marking of k) in manufactures literature N/A

- integral modules a) to g) in literature N/A

7.3 Durable and legibility of marking N/A

- marking of a), b), c) and f) legible after test withwater

N/A

- marking of d) to j) inspection of compliance N/A

8 TERMINALS

Screw terminals according section 14 of IEC 60598-1: N/A

Separately approved; component list N/A

Part of the luminaire N/A

Screwless terminals according section 15 of IEC 60598-1: N/A

Separately approved; component list N/A

Part of the luminaire N/A

Connectors according IEC 60838-2-2: N/A

Separately approved; component list N/A

9 (9) PROVISION FOR PROTECTIVE EARTHING

- (9.1) Provisions for protective earthing N/A

Terminal complying with clause 8 N/A

Locked against loosening and not possible to loosenby hand

N/A

Not possible to loosen clamping meansunintentionally on screwless terminals

N/A

Earthing via means of fixing N/A

Earthing terminal only used for the earthing of thecontrol gear

N/A

All parts of material minimizing the danger ofelectrolytic corrosion

N/A

Made of brass or equivalent material N/A

Contact surface bare metal N/A

- (9.2) Provision for functional earthing N/A

Comply with clause 8 and 9.1 N/A

- (9.3) Earth contact via the track on the printed board N/A

Page 42: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 3 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Test with a current of 25 A between earthing terminaland each of the accessible metal parts;measured resistance (Ω) at ≥ 10 A according 7.2.3 ofIEC 60598-1: < 0,5 Ω ......................................... :

N/A

- (9.4) Earthing of built-in lamp controlgear N/A

Earth by means of fixing to earthed metal of luminairein compliance of 7.2 of IEC 60598-1

N/A

Earthing terminal only for earthing the built-incontrolgear

N/A

- (9.5) Earthing via independent controlgear N/A

- (9.5.1) Earth connection to other equipment N/A

Looping or through connection, conductor min. 1,5mm² and of copper or equivalent

N/A

Protective earthing wires in line with 5.3.1.1 andclause 7

N/A

- (9.5.2) Earthing of the lamp compartments powered via the independent lamp controlgear N/A

Test with a current of 25 A between input and outputearth terminals; measured resistance (Ω) betweenearthing terminal and each of the accessible metalparts at ≥ 10 A according 7.2.3 of IEC 60598-1:< 0,5 Ω .............................................................. :

N/A

Output earthing terminal marked as in 7.1 t) of IEC61347-1

N/A

10 (10) PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS

- (10.1) Controlgear protected against accidental contact withlive parts

Reply on luminaire enclosurefor providing basic insulation

N/A

- (A2) The current flowing between the part concerned andearth is measured and does not exceed

0,7 mA (peak) or 2 mA d.c. ................................ :

N/A

- (A2) For frequencies above 1 kHz, the current does notexceed 0,7 mA (peak) multiplied by the value of thefrequency in kilohertz or 70 mA (peak) ............... :

N/A

- (A3) The voltage between the part concerned and anyaccessible part is measured and does not exceed 34V (peak) ............................................................. :

N/A

- (10.1) Lacquer or enamel not used for protection orinsulation

N/A

Adequate mechanical strength on parts providingprotection

N/A

Page 43: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 4 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- (10.2) Capacitors > 0,5 µF: voltage after 1 min (V): < 50 V........................................................................... :

N/A

- (10.3) Controlgear providing SELV N/A

Accessible conductive parts are insulated from liveparts by double or reinforced insulation in SELVcontrolgear

N/A

No connection between output circuit and the body orprotective earthing circuit

N/A

No possibility of connection between output circuitand the body or protective earthing circuit throughother conductive parts

N/A

SELV outputs separated by at least basic insulation N/A

ELV conductive parts insulated as live parts N/A

Tests according Annex L of IEC 61347-1 N/A

- (10.4) Accessible conductive parts in SELV circuits N/A

Output voltage under load ≤ 25 V r.m.s. or ≤ 60 V d.c. N/A

If output voltage > 25 V r.m.s. or > 60 V d.c.;

No load output ≤ 35 V peak or ≤ 60 V d.c and touchcurrent does not exceed 0,7 mA (peak)or 2 mA d.c. ........................................................... :

N/A

One conductive part is insulated if output voltage orcurrent exceeding the values above and withstandtest voltage 500 V

N/A

Double or reinforced insulation bridged byappropriate and at least two resistors or two Y2capacitors or one Y1 capacitor

N/A

Y1 or Y2 capacitors comply with IEC 60384-14 N/A

Resistors comply with test (a) in 14.1 ofIEC 60065

N/A

11 (11) MOISTURE RESISTANCE AND INSULATION

After storage 48 h at 91-95% relative humidity and 20-30 °C measuring of insulationresistance with d.c. 500 V (MΩ):

P

For basic insulation ≥ 2 MΩ ................................... : >500MΩ P

For double or reinforced insulation ≥ 4 MΩ ............. : N/A

Between primary and secondary circuits incontrolgear providing SELV, values in Annex L in IEC61347-1

N/A

Page 44: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 5 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

12 (12) ELECTRIC STRENGTH

Immediately after clause 11 electric strength test for1 min

P

Basic insulation for SELV, test voltage 500 V N/A

Working voltage ≤ 50 V, test voltage 500 V N/A

Working voltage > 50 V ≤ 1000 V, test voltage (V): P

Basic insulation, 2U + 1000 V 1480 P

Supplementary insulation, 2U + 1000 V N/A

Double or reinforced insulation, 4U + 2000 V N/A

No flashover or breakdown P

Solid or thin sheet insulation for double or reinforcedinsulation fulfil the requirements in Annex N in IEC61347-1

N/A

13 (14) FAULT CONDITIONS

- (14) When operated under fault conditions the controlgear: N/A

- does not emit flames or molten material N/A

- does not produce flammable gases N/A

- protection against accidental contact not impaired N/A

Thermally protected controlgear does not exceed themarked temperature value

N/A

Fault conditions: capacitors, resistors or inductorswithout proof of compliance with relevantspecifications have been short-circuited ordisconnected

(see appended table) N/A

- (14.1) Short-circuit of creepage distances and clearances ifless than specified in clause 16 in Part 1 (exceptbetween live parts and accessible metal parts)

(see appended table) N/A

Creepage distances on printed boards less thanspecified in clause 16 in Part 1 provided with coatingaccording to IEC 60664-3

N/A

- (14.2) Short-circuit or interruption of semiconductor devices (see appended table) N/A

- (14.3) Short-circuit across insulation consisting of lacquer,enamel or textile

(see appended table) N/A

- (14.4) Short-circuit across electrolytic capacitors (see appended table) N/A

- (14.5) After the tests has been carried out on three samples: N/A

The insulation resistance ≥ 1 MΩ ....................... : N/A

Page 45: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 6 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

No flammable gases N/A

No accessible parts have become live N/A

During the tests, a five-layer tissue paper, where thetest specimen is wrapped, does not ignite

N/A

- (14.6) Relevant fault condition tests with high-power supply N/A

13.2 Overpower condition P

Module withstands overpower condition >15 min. P

Module with automatic protective device or powerlimiter, test performed 15 min. at limit.

N/A

No fire, smoke or flammable gas is produced P

Molten material does not ignite tissue paper, spreadbelow the module

P

15 CONSTRUCTION

Wood, cotton, silk, paper and similar fibrous materialnot used as insulation

P

16 (16) CREEPAGE DISTANCES AND CLEARANCES

- (16) Creepage and distances and clearances incompliance with IEC 61347-1

See main report for details. P

Insulating lining of metallic enclosures N/A

Basic insulation on printed boards tested accordingto clause 14

N/A

Distances subjected to both sinusoidal voltage asnon-sinusoidal pulses not less than value in Table 16

P

Creepage distances not less than minimumclearance

P

16 (-) Conductive accessible parts in compliance withapplicable parts of IEC 60598-1

See main report for details. P

17 (17) SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS

Cl. 17 refer to Cl. 17 of IEC 61347-1 which refer to Cl. 4.11 and 4.12 of IEC 60598-1(clause numbers between parentheses refer to IEC 60598-1)

(4.11) Electrical connections P

(4.11.1) Contact pressure P

(4.11.2) Screws: N/A

- self-tapping screws N/A

Page 46: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 7 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

- thread-cutting screws N/A

(4.11.3) Screw locking: N/A

- spring washer N/A

- rivets N/A

(4.11.4) Material of current-carrying parts P

(4.11.5) No contact to wood or mounting surface P

(4.11.6) Electro-mechanical contact systems N/A

(4.12) Mechanical connections and glands N/A

(4.12.1) Screws not made of soft metal N/A

Screws of insulating material N/A

Torque test: torque (Nm); part .................................: N/A

Torque test: torque (Nm); part .................................: N/A

Torque test: torque (Nm); part .................................: N/A

(4.12.2) Screws with diameter < 3 mm screwed into metal N/A

(4.12.4) Locked connections: N/A

- fixed arms; torque (Nm) ........................................: N/A

- lampholder; torque (Nm) .......................................: N/A

- push-button switches; torque 0,8 Nm ....................: N/A

(4.12.5) Screwed glands; force (Nm)....................................: N/A

18 (18) RESISTANCE TO HEAT, FIRE AND TRACKING

- (18.1) Ball-pressure test ...................................................: See Test Table 18 (18.1) N/A

- (18.3) Glow-wire test (650°C) ...........................................: See Test Table 18 (18.3) N/A

- (18.4) Needle-flame test (10 s) .........................................: See Test Table 18 (18.4) N/A

- (18.5) Proof tracking test ..................................................: See Test Table 18 (18.5) N/A

19 (19) RESISTANCE TO CORROSION

- test according 4.18.1 of IEC 60598-1 N/A

- adequate varnish on the outer surface N/A

20 INFORMATION FOR LUMINAIRE DESIGN

Information in Annex D (informative)

21 HEAT MANAGEMENT

Page 47: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 8 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

21.1 General N/A

Exchangeability is safeguarded by cap or base N/A

21.2 Heat-conducting foil and paste N/A

Heat-conducting foil delivered with the module ifnecessary

N/A

22 PHOTOBIOLOGICAL SAFETY

22.1 UV radiation N/A

Luminous radiation not exceed 2mW/klm N/A

22.2 Blue light hazard P

Assessed according to IEC TR 62778 RG2 P

22.3 Infrared radiation N/A

Requirements for infrared radiation when required N/A

A ANNEX A - TESTS

All tests performed in accordance with the advicegiven in Annex H of IEC 61347-1, if applicable

P

13 (14) TABLE: tests of fault conditions N/A

Part Simulated fault Hazard

18 (18.1) TABLE: Ball Pressure Test of Thermoplastics N/A

Allowed impression diameter (mm) ................... : 2,0mm

Object/ Part No./ Material Manufacturer/trademark

Test temperature (°C) Impression diameter (mm)

-- -- -- --

Supplementary information:--

18 (18.3) TABLE: Glow-wire test N/A

Glow wire temperature ........................................ : 650°C

Object/ Part No./Material

Manufacturer/trademark

Duration ofapplication of test

flame (ta); (s)

Ignition ofspecified layer

Yes/No

Duration ofburning (tb)

(s)Verdict

-- -- -- -- -- --

Any flame or glowing of the sample extinguished within 30 s of withdrawing the glow-wire, andany burning or molten drop did not ignite the underlying parts (Yes/No) ..................................... :

--

Page 48: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.1

EN 62031

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 9 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Supplementary information:--

18 (18.4) TABLE: Needle-flame test N/A

Object/ Part No./Material

Manufacturer/trademark

Duration ofapplication of test

flame (ta); (s)

Ignition ofspecified layer

Yes/No

Duration ofburning (tb)

(s)Verdict

-- -- -- -- -- --

Supplementary information:--

18 (18.5) TABLE: Proof tracking test N/A

Test voltage PTI .................................................. : 175 V

Object/ Part No./ Material Manufacturer/trademark

Withstand 50 drops without failure on threeplaces or on three specimens

Verdict

-- -- -- -- -- --

Supplementary information:--

ANNEX 1 SELV-operated LED modules N/A

Cl. 5.5 refer to ANNEX I of IEC 61347-2-13 which refer to ANNEX L of IEC 61347-1(clause numbers between parentheses refer to ANNEX L of IEC 61347-1).

ANNEX 3 Screw terminals (part of the luminaire) N/A

ANNEX 4 Screwless terminals (part of the luminaire) N/A

Page 49: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No. 2

Clause Requirement - Test Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 1 of 3

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Additional requirements of VC8055 for South Africa P

3 REQUIREMENTS P

3.1 All apparatus shall be rated at the national standardlow voltage, i.e. 230 V ac, single-phase, 50 Hz, or400 V ac, 3-phase, 50 Hz, or shall have a ratedvoltage range that includes 230 V/400 V ac.

P

3.2 All apparatus shall be capable of operating safelywithin the range + - 10% of the standard voltage.

P

3.3 Household and similar electrical appliances shallcomply with the relevant requirements of SANS60335-1 / IEC 60335-1 Household and similarappliances- safety, Part 1: General requirements,together with the appropriate Part(s) 2 of the SANS60335 series.

N/A

3.4 Audio, Video, and similar electronic apparatus shallcomply with the relevant requirements of SANS60065/IEC 60065 audio, video and similarelectronic apparatus – Safety requirements.

N/A

3.5 Luminaires shall comply with the relevant requirements of the appropriate of thefollowing standards:

P

a) SANS 60598-1/IEC 60598-1 Luminaires – Part 1:General requirements and test, together withappropriate Part(s) 2 of the SANS 60598/IEC 60598series (excluding Luminaires for emergencylighting);

P

b) Luminaires shall additionally comply with thepower factor requirements of SANS 475 Luminairesfor interior lighting, street and floodlighting –Performance requirements;

P

c) Luminaires for emergency lighting shall complywith SANS 1464-22 Safety of luminaries, Part 22:Luminaires for emergency lighting;

N/A

d) electrical supply track systems for luminariesshall comply with SANS 60570/IEC 60670 Electricalsupply track systems for luminaries.

N/A

3.7 -held motor-operated or magnetically driven electrictools shall comply with the relevant req Handuirements of SANS 60745-111EC 60745-1 Hand-held motoroperated electric tools - Safety, Part 1:General requirements, together with theappropriate Part(s) 2 of the SANS 6074511EC60745 series.

N/A

Page 50: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No. 2

Clause Requirement - Test Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 2 of 3

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.8 Transportable motor-operated electric tools shallcomply with the relevant requirements of SANS61029-111EC 61029-1 Safety of transportablemotor-operated electric tools Part 1: Generalrequirements, together with the appropriate Part(s)2 of the SANS 6102911EC 61029 series.

N/A

3.9 Electrical equipment for test and measurement,control, and laboratory use shall comply with therelevant requirements of SANS 61010-1/1EC61010-1 Safety requirements for electricalequipment for measurement, control and laboratoryuse Part1: General requirements, together with theappropriate Parts(s) 2 of the SANS 61010llEC61010 series.

N/A

3.10 The manufacturer or importer shall apply to theRegulator for approval of every type and model ofapparatus before offering it for sale, in accordancewith the requirements of Annex A.

P

3.11 When a new edition of a standard is published,approvals of products in accordance with theprevious edition of that standard shall remain validfor five years unless decided otherwise by theMinister.

N/A

3.12 The manufacturer and/or the importer or both shallinform the Regulator of any change in design orcomponents that affects any mandatoryrequirement in terms of this compulsoryspecification. In the event of such change orchanges the Regulator may, at its discretion,demand the submission of fresh evidence ofconformity or a new application for approval.

N/A

3.13 The manufacturer and/or the importer or both shallon request provide the Regulator within two workingdays with satisfactory proof of approval in respectof any apparatus included in the scope of thiscompulsory specification.

N/A

3.14 The manufacturer and/or importer shall on requestprovide the Regulator within five working days withsatisfactory proof of conformity of production.

N/A

Page 51: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No. 2

Clause Requirement - Test Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 3 of 3

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.15 Failure to provide such proof shall constitutereasonable grounds for suspicion of non-conformance with the requirements of thiscompulsory specification.

N/A

4 EQUIVALENCE OF STANDARDS ---

Standards issued by different standardization bodies (for example, ISO, IEC, EN)that can be proved by the applicant to be technically identical to a South AfricanNational Standard are deemed to be the equivalent of that South African NationalStandard. Proof of conformity with such a standard shall be accepted asconformity with the corresponding South African National Standard.

---

5 CONFORMITY WITH STANDARDS REFERRED TO BY EDITION ANDDATE OF PUBLICATION

---

5.1 For the purposes of this compulsory specification, anew edition of a standard shall become effectivetwo months from its date of publication as a SouthAfrican National Standard.

N/A

5.2 New products or products resubmitted for approvalbecause of a change indesign or materials shall, in all cases, be evaluatedagainst the requirements of thelatest edition of any referenced standard.

N/A

6 ASSESSMENT OF CONFORMITY ---

6.1 The following alternative forms of evidence shall be submitted to theRegulator as proof of conformity with the requirements of this compulsoryspecification:

---

a) Copy of a valid certificate of IECEE conformityissued by a member of the IEC CB scheme; or

P

b) Copy of a valid test certificate issued less than36 months prior to date of application by a testlaboratory recognized by the Regulator.

P

6.2 The certificate or test report shall prove conformitywith all the applicable mandatory requirements ofthis compulsory specification.

P

6.3 S.3 Evidence of conformity shall be traceable to thespecific model and type of apparatus in question.

P

--End of Report--

Page 52: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 1 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

ATTACHMENT TO TEST REPORT IEC 60598-1AUSTRALIA AND NEW ZEALAND NATIONAL DIFFERENCES

Differences according to .............. :IEC 60598-1:2008

Attachment Form No..................... :AS/NZS 60598.1:2013

Attachment Originator .................. :TÜV SÜD

Master Attachment ........................ :2014-02

Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment(IECEE), Geneva, Switzerland. All rights reserved.

National Differences —

3.2.12 In Australia, luminaires for household use and similar with supply cords which are

not fitted with a plug shall be marked with a cord tag with the symbol for “must be

installed by a licensed electrician”

N/A

3.1 Move Item 3.2.21 from the centre column to the right hand column. P

3.3 Add the following text after the second paragraph: P

In Australia and New Zealand, instructions and othertexts required by this Standard shall be written inEnglish.

P

3.3.7 Delete Clause 3.3.7 and replace with the following: N/A

Luminaires for use with metal halide lamps shall beprovided with instructions that state the substance ofthe following:

To avoid potential unsafe lamp failure, the luminaireshall be switched off for at least 30 minutes at leastonce a week. In addition, the luminaire shall beoperated:

— complete with its protective shield; or

— with a double jacketed lamp.

N/A

3.3.10 Delete Clause 3.3.10. N/A

3.3.21 Add the following new Clause: N/A

The instructions shall contain details related tocomponents in the luminaire that require replacementas part of a maintenance program.

N/A

4.8 Add the following paragraph after the third paragraph: N/A

Page 53: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 2 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Switches that indicate an off position shall havecontacts with an air break and comply withAS/NZS 3133 or AS/NZS 61058.1.

N/A

4.2A Add the following new Clause after Clause 4.2: N/A

Capacitors shall be of a type to ensure that anycapacitor failure results in a failsafe outcome (i.e. thecapacitor type will fail in the open-circuit mode onlyand is protected against fire or shock hazard).

Capacitors shall be not less than Type B capacitorswith metal body and break action protection inaccordance with IEC 61048 and IEC 61049. Acapacitor complying with ANCI/EIA-456-A shallcomply with IEC 61049 and IEC 61048:2006excluding the endurance test of 18.1.1.

NOTE Capacitors of Class S2 (formerly referred toas P2) of IEC 60252 (all parts) do not meet the safetyrequirements of a Type B capacitor.

In addition, capacitors shall have a minimum voltagerating of 250 V at a temperature rating of 100 °C or280 V at a temperature rating of 85 °C.

Capacitors likely to be permanently subjected to thesupply voltage, and used for radio interferencesuppression or for voltage dividing, shall comply withIEC 60384-14.

N/A

5.2.1 Delete the first paragraph and replace with the following: P

Page 54: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 3 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Luminaires shall be provided with only one of thefollowing means of connection and isolation to thesupply.

Fixed luminaires:

— device for the connection of luminaires;

— terminals; plug for engagement with socket- outlets;

— connecting lead (tails);

— supply cord and plug;

— adapter for engagement with supply tracks;

— appliance inlet;

— installation coupler;

— luminaire coupler;

Portable luminaires:

— supply cord with plug;

— appliance inlet.

Track-mounted luminaires:

— adaptor;

— connector.

P

Delete the second and third paragraph. P

5.2.2 Delete the first paragraph and replace with the following: P

Supply cords used as a means of connection to thesupply, when supplied by the luminaire manufacturer,shall be at least equal in their mechanical andelectrical properties to those specified in IEC 60227and IEC 60245, as indicated in Table 5.1, orAS/NZS 3191, and shall be capable of withstanding,without deterioration, the highest temperature towhich they may be exposed under normal conditionsof use.

P

2 Table 5.1, delete rows 4 and 5 and replace with the following: N/A

N/A

Page 55: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 4 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Delete the third paragraph and replace with the following: P

To provide adequate mechanical strength, thenominal cross-sectional area of the conductors shallbe not less than:

P

— 0,75 mm2; P

— 1,0 mm2 for portable rough service luminaires. N/A

5.2.16 Add the following text at the end of Clause 5.2.16: N/A

Class II luminaires for fixed wiring incorporating anappliance coupler shall not have means to allowfurther luminaires to be connected, including loopingin by cascading.

N/A

Luminaire couplers incorporated with the luminaireshall comply with IEC 61995-1.

N/A

5.2.18 Delete Clause 5.2.18 and replace with the following: N/A

All portable luminaires with a flexible supply cordshall be fitted with a plug complying withAS/NZS 3112. Other luminaires with flexible cordsshall be fitted with a plug complying withAS/NZS 3112, unless they have the warning allowedby Clause 3.2.12.

N/A

5.2.19 Add the following new Clause: N/A

Installation couplers incorporated within luminairesshall comply with the requirements ofAS/NZS 61535.

N/A

Luminaires incorporating installation couplers mayhave means to allow further luminaires to beconnected by cascading provided the through wiringis rated for the current rating of the installationcoupler.

N/A

5.3.1 Delete the third paragraph and replace with the following: P

Internal wires coloured green, yellow or green/yellowcombination shall be used for making protectiveearth connections only. Functional earth connectionsshall not be made by wires coloured green, yellow orgreen/yellow combination.

P

Add the following new Note: P

NOTE 3 Internal wires of other colours are notprecluded from making protective earthingconnections.

P

Page 56: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 5 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

7.2.11 Delete the third paragraph and replace with the following: P

All conductors, whether internal or external, colouredgreen, yellow or green/yellow combination, shall onlybe connected to an earthing terminal.

P

8.2.1 Delete the first paragraph and Note 1 and replace with the following: P

Luminaires shall be so constructed that their liveparts and basic insulation are not accessible whenthe luminaire has been installed and wired as innormal use. Live parts shall not be accessible whenthe luminaire is opened as necessary for replacinglamps, replaceable light sources or (replaceable)starters, even if the operation cannot be achieved byhand.

NOTE Examples of parts with basic insulation arecables intended for internal wiring, controlgear forbuilding-in etc.

This does not apply to the non-current -carrying partsof caps which comply with the relevant IEC safetystandard.

P

Where a protective cover is used over a non-user-replaceable light source to provide protection againstelectric shock, and the cover is marked with the“caution, electric shock risk” symbol in accordancewith IEC 60417-6042, the cover shall be left in placeduring the tests and inspections detailed by Section 8of this Standard. The cover shall be held securely inposition by fixings requiring the use of a tool for theirremoval, and at least two independent fixings shallbe used.

N/A

12.1 Add the following new Note after Table 12.1: N/A

NOTE Luminaire manufacturers should consider themaximum ambient air temperature in the vicinity ofcomponents such as starting devices and electronicballasts or converters. Component performancespecifications advise manufacturers to mark orsupply life data as maximum ambient air temperaturebased on 50,000 hrs. This t-life is often marked as taand is the temperature of the air in the vicinity of thecomponent and is not related to the luminaire ta. Assuch, luminaire manufacturers should measure airtemperature in the vicinity of such components,within the luminaire, as even those complying withtheir tc point measurements can still fail prematurelyif t-life is exceeded.

N/A

Page 57: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 6 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

13.3 Delete Clause 13.3 and replace with the following: P

Parts of non-metallic material shall be resistant toflame and ignition.

For materials other than ceramic, compliance ischecked by the tests of 13.3.1 and 13.3.2, 13.3.3 and13.3.4, as appropriate.

This requirement does not apply to decorative trims,knobs, wiring insulation and other parts not likely tobe ignited or to propagate flames from inside theluminaire.

This Clause applies to all parts, includingcomponents, even if they have been tested to theirown standard.

N/A

13.3.1 Parts of non-metallic material supporting connectionsshall withstand the following test:

Parts are subject to a test using a nickel-chromiumglow-wire.

The test apparatus and test procedure shall be thosedescribed in AS/NZS 60695.2.10.

The glow wire is heated to 750 °C and applied to thetest sample for 30 s.

For all tests, any flame or glowing of the sample shallextinguish within 30 s of withdrawing the glow-wire,and any burning or molten drop shall not ignite asingle layer of tissue paper specified in 4.187 ofISO 4046-4:2002, spread out horizontally200 mm ± 5 mm below the sample.

N/A

Page 58: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 7 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

13.3.2 All other parts of non-metallic material shallwithstand the following test:

Parts are subject to a test using a nickel-chromiumglow-wire.

The test apparatus and test procedure shall be thosedescribed in AS/NZS 60695.2.10.

The glow wire is heated to 650 °C and applied to thetest sample for 30 s.

For all tests, any flame or glowing of the sample shallextinguish within 30 s of withdrawing the glow-wire,and any burning or molten drop shall not ignite asingle layer of tissue paper specified in 4.187 ofISO 4046-4:2002, spread out horizontally200 mm ± 5 mm below the sample.

P

Page 59: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 8 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

13.3.3 During the application of the 750 °C glow wire test ofClause 13.3.1, if a flame is produced that persists forlonger than 2 s, the luminaire is further tested asfollows:

The needle-flame test of AS/NZS 60695.11.5 isapplied to non-metallic parts that encroach within theenvelope of a vertical cylinder having a diameter of20 mm and a height of 50 mm above the point ofapplication of the glow wire. The needle flame isapplied to the test sample for 30 s.

Parts shielded by a barrier that meets the needle-flame test of AS/NZS 60695.11.5 are not tested.

NOTE This requires the needle flame to be appliedto all parts likely to be impinged upon by the glow-wire flame within the hypothetical envelope of avertical cylinder positioned above the point ofapplication of the glow-wire. This applies to all partsunless there is a barrier that passes the needle-flametest and is within the cylinder and would protect thepart from the glow-wire flame.

The duration of burning shall not exceed 30 s afterremoval of the test flame and any burning drop shallnot ignite the underlying parts or tissue paperspecified in 4.187 of ISO 4046-4:2002, spread outhorizontally 200 mm ± 5 mm below the sample.

The needle-flame test is not carried out on parts thatare made of material classified as V-0 or V-1according to AS/NZS 60695.11.10. The sample ofmaterial classified in accordance withAS/NZS 60695.11.10 shall be no thicker than therelevant part.

N/A

Page 60: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.3

Deviation for Australia and New Zealand of IEC 60598-1

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 9 of 9

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

13.3.4 PCBs in luminaires shall be subject to the needle-flame test of AS/NZS 60695.11.5. The needle flameshall be applied for 30 seconds to an edge of thePCB at least 10 mm from a corner.

The duration of burning shall not exceed 15 s afterremoval of the needle flame and any burningdroplets shall not ignite the tissue paper placedunderneath the PCB.

The needle-flame test is not carried out on PCBsmade of material that is V-0 rated according toAS/NZS 60695.11.10.

N/A

Clause 18.3.1-2-Glow-wire test

Part under test Material Colour Glow-wiretemperature(°C)

Burning timeduring golw-wireapplication (s)

Burning timeafter removedgolw-wire (s)

Height offlame(mm)

LED lens Plastic White 650 0 0 0

Clause 13.3.3-Needle flame testPart under test Material Colour Duration of

flameapplication (s)

Burning timeduring flameapplication (s)

Burning timeafter removedthe flame (s)

Height offlame(mm)

-- -- -- -- -- -- ---- -- -- -- -- -- --

--End of report.---

Page 61: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 1 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

IEC60598_2_3I - ATTACHMENT

Clause Requirement + Test Result - Remark Verdict

ATTACHMENT TO TEST REPORT IEC 60598.2.3(AUSTRALIA/NEW ZEALAND) NATIONAL DIFFERENCES

(Luminaires)

(Part 2.3 Particular requirements— Luminaires for road and street lighting)

Differences according to ............... : AS/NZS 60598.2.3: 2015

AS/NZS 60598.1:2013

Attachment Form No. .................... : AU_NZ_ND_IEC60598_2_3I

Attachment Originator .................. : JAS-ANZ

Master Attachment ........................ : 2017-06

Copyright © 2017 IEC System for Conformity Testing and Certification of Electrical Equipment(IECEE), Geneva, Switzerland. All rights reserved.

National Differences P

Appendix ZZ Variations to IEC 60598-2-3 Ed 3.1(2011)

Normative

P

ZZ1 Scope

This Appendix sets out variations between this Standard and IEC 60598-2-3 Ed3.1(2011) and additional requirements to cover issues that have not beenaddressed by the International Standard

(AS/NZS 60598.1:2013)

P

ZZ2 Variations P

(0.1) Scope and object P

(0.1) Addition

Add the following text at the end of Clause 0.1

Where the term “lamp” is used in this Standard, it is takento include electric light sources. LED light sources aresubject to the same test parameters as “other dischargelamps”.

(AS/NZS 60598.1:2013)

P

3.1 (0.1) Variation

At the end of Clause 3.1, add the following text:

This Standard also specifies the safety requirements forroad and street light luminaires to provide adequateprotection from water and ambient temperatureconditions that may be expected in Australia and NewZealand.

This Standard is to be read in conjunction withAS/NZS 60598.1

(AS/NZS 60598.2.3:2015)

P

Page 62: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 2 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.1 (0.2) Normative references N/A

3.1 (0.2) Addition

Add the following normative references:

AS/NZS 3112, Approval and test specification—plugs

and socket-outlets

AS/NZS 3133, Approval and test specification—Air-

break switches

AS/NZS 3191, Electric flexible cords

AS/NZS 60695.11.10, Fire hazard testing—Part 11.10:

Test flames—50 W horizontal and vertical flame test

methods (IEC 60695-11-10:1999, IDT)

AS/NZS 61535, Installation couplers intended for

permanent connection in fixed installations (IEC 61535,

Ed. 1.0 (2009) MOD)

IEC 61048, Auxiliaries for lamps—Capacitors for use in

tubular fluorescent and other discharge lamp circuits—

General and safety requirements

IEC 61049, Auxiliaries for lamps—Capacitors for use in

tubular fluorescent and other discharge lamp circuits—

Performance requirements

IEC 61995-1, Devices for the connection of luminaires

for household and similar purposes—Part 1: General

(AS/NZS 60598.1:2013)

N/A

3.2 (0.4) General test requirements and verification P

Page 63: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 3 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.2 (0.4.2) Addition

After the first paragraph, add the following text:

In Australia, for equipment, other than class IIIequipment, that is intended for connection to the supplymains and not marked with:

— a rated voltage of at least 240 V for single-phaseequipment or a rated voltage of at least 415 V forthree-phase equipment; or

— a rated voltage range that includes 240 V forsingle-phase equipment and 415 V for three-phaseequipment,

the rated voltage is equal to 240 V for single-phaseequipment and 415 V for three-phase equipment, andthe upper limit of the voltage range is equal to 240 V forsingle-phase equipment and 415 V for three-phaseequipment.

(AS/NZS 60598.1:2013)

P

3.2 (0.4) Addition

After the second paragraph, add the following text:

In Australia, the declared ambient temperature ta shall be40°C or above, for the thermal tests of Clause 3.12

In Australia and New Zealand, the IP rating for water testsof Clause 3.12 or 3.13 shall be IPX4

(AS/NZS 60598.2.3:2015)

45°C P

3.2 (0.5) Components of luminaires P

3.2 (0.5) Addition

Add the following paragraph after the title:

Throughout this document, where there is a relevantAustralian/New Zealand Standard, it replaces the IECStandard unless otherwise specified

(AS/NZS 60598.1:2013)

P

3.2 (0.5.2A) Addition

Add the following new Clause after Clause 0.5.2

0.5.2A Capacitors

Capacitors shall comply with Clause 4.2A.

(AS/NZS 60598.1:2013)

N/A

3.3 DEFINITIONS P

3.3 (1.2) Addition

Add the following new definitions after 1.2.86

P

Page 64: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 4 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

1.2.87installation couplerconnecting device consisting of an installation femaleconnector and an installation male connector providedwith retaining means for permanent connection notintended to be engaged or disengaged under load norto be engaged or disengaged other than during firstinstallation, during maintenance of the wiring system orduring re-configuration of the wiring system

N/A

1.2.88

installation male connectorload side portion of an installation coupler which containsthe male contacts

N/A

1.2.89installation female connectorsupply side portion of an installation coupler which containsthe female contacts

N/A

1.2.90installation coupler systemfamily of installation couplers consisting of one or moreinstallation female connectors compatible by mechanicalcoding features with one or more installation maleconnectors, with the same ratings produced according tothe specification of one manufacturer

(AS/NZS 60598.1:2013)

N/A

3.4 CLASSIFICATION OF LUMINAIRES P

3.4 (2.2) Addition

At the end of Clause 2.2, add the following paragraph:

Class 0 luminaires are not allowed in Australia or NewZealand

(AS/NZS 60598.1:2013)

Class I P

3.5 MARKING P

3.5

(Table 3.1)

Variation

Move Item 3.2.21 from the centre column to the right handcolumn

(AS/NZS 60598.1:2013)

N/A

Page 65: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 5 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.5 (3.2.12) Addition

Add the following paragraph after Note 3

In Australia, luminaires for household use and similarwith supply cords which are not fitted with a plug shallbe marked with a cord tag with the symbol for “must beinstalled by a licensed electrician”.(Refer to Figure ZZ1).

(AS/NZS 60598.1:2013)

N/A

3.5 (3.3) Addition

Add the following text after the second paragraph:

In Australia and New Zealand, instructions and othertexts required by this Standard shall be written inEnglish.Compliance is checked by inspection

(AS/NZS 60598.1:2013)

P

3.5 (3.3.7) Variation

Delete Clause 3.3.7 and replace with the following:

3.3.7 Luminaires for use with metal halide lamps shallbe provided with instructions that state the substance ofthe following:

To avoid potential unsafe lamp failure, the luminaireshall be switched off for at least 30 minutes at leastonce a week. In addition, the luminaire shall beoperated:

— complete with its protective shield; or— with a double jacketed lamp

(AS/NZS 60598.1:2013)

N/A

3.5 (3.3.10) Deletion

Delete Clause 3.3.10

(AS/NZS 60598.1:2013)

N/A

3.5 (3.3.21) Addition

Add the following new Clause:

3.3.21 The instructions shall contain details related tocomponents in the luminaire that require replacement aspart of a maintenance program.

(AS/NZS 60598.1:2013)

N/A

3.6 CONSTRUCTION P

Page 66: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 6 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.6 (4.8) Addition

Add the following paragraph after the third paragraph:

Switches that indicate an off position shall have contactswith an air break and comply with AS/NZS 3133 orAS/NZS 61058.1.

(AS/NZS 60598.1:2013)

N/A

3.6 (4.8) Variation

Delete the first paragraph and replace with the following:

In Australia and New Zealand, all luminaires shall haveprotection against ingress of moisture of at least IPX4,except for tunnel-lighting luminaires and glazing of column-integrated luminaires with an open-sided external part, forwhich IPX5 is required.

(AS/NZS 60598.2.3:2015)

IP66 P

3.10 EXTERNAL AND INTERNAL WIRING P

3.10 (5.2.1) Variation

1. Delete the first paragraph and replace with the

following

Luminaires shall be provided with only one of thefollowing means of connection and isolation to thesupply.

Fixed luminaires:

— device for the connection of luminaires;

— terminals; plug for engagement with socket-outlets;

— connecting lead (tails);

— supply cord and plug;

— adapter for engagement with supply tracks;

— appliance inlet;

— installation coupler;

— luminaire coupler;

Portable luminaires:

— supply cord with plug;

— appliance inlet.

Track-mounted luminaires:

— adaptor;

— connector.

P

2 Delete the second and third paragraph. N/A

Page 67: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 7 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3. Add the following text after Note 3:

In Australia, non-portable luminaires with a supplycord shall be fitted with a plug complying withAS/NZS 3112 or a coupler complying with itsstandard, except where the luminaire hasmarkings and instructions that comply withClause 3.2.12, in which case, a plug or coupler isnot required. However, for other than portableluminaires a plug is not required if the luminairehas markings and instructions in accordance withClause 3.2.12.

The plug portion of a luminaire with integral pinsshall comply with the relevant requirements ofAS/NZS 3112.

NOTE 1 Relevant requirements for equipment with

integral pins are outlined in AS/NZS 3112.

NOTE 2 PVC-insulated connection cords should not

be used with outdoor luminaires in cold alpine

locations.

(AS/NZS 60598.1:2013)

N/A

3.10 (5.2.2) Variation

1. Delete the first paragraph and replace with

the following:

Supply cords used as a means of connection tothe supply, when supplied by the luminairemanufacturer, shall be at least equal in theirmechanical and electrical properties to thosespecified in IEC 60227 and IEC 60245, asindicated in Table 5.1, or AS/NZS 3191, and shallbe capable of withstanding, without deterioration,the highest temperature to which they may beexposed under normal conditions of use.

P

2. ..........................................................................Table 5.1, delete rows 4 and 5 and replace with the following:

Luminaires which are otherthan ordinary Portable roughservice luminaires

60245 IEC 57 60227 IEC 53

Portable rough serviceluminaires

60245 IEC 66 PVC insulatedand sheathedheavy dutyflexible cord

P

Page 68: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 8 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3. ..........................................................................Deletethe third paragraph and replace with the following:

To provide adequate mechanical strength, thenominal cross-sectional area of the conductorsshall be not less than:

— 0,75 mm2;—1,0 mm2 for portable rough service luminaires.

(AS/NZS 60598.1:2013)

P

3.10 (5.2.16) Addition

Add the following text at the end of Clause 5.2.16:

Class II luminaires for fixed wiring incorporating anappliance coupler shall not have means to allow furtherluminaires to be connected, including looping in bycascading.

Luminaire couplers incorporated with the luminaire shallcomply with IEC 61995-1.

(AS/NZS 60598.1:2013)

N/A

3.10 (5.2.18) Variation

Delete Clause 5.2.18 and replace with the following:

5.2.18 All portable luminaires with a flexible supplycord shall be fitted with a plug complying withAS/NZS 3112. Other luminaires with flexible cords shallbe fitted with a plug complying with AS/NZS 3112,unless they have the warning allowed by Clause 3.2.12

(AS/NZS 60598.1:2013)

N/A

3.10 (5.2.19) Addition

Add the following new Clause:

5.2.19 Installation couplers incorporated withinluminaires shall comply with the requirements ofAS/NZS 61535.

Luminaires incorporating installation couplers may havemeans to allow further luminaires to be connected bycascading provided the through wiring is rated for thecurrent rating of the installation coupler.

(AS/NZS 60598.1:2013)

N/A

Page 69: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 9 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.10 (5.3.1) Variation

1. Delete the third paragraph and replace with thefollowing:

Internal wires coloured green, yellow orgreen/yellow combination shall be used formaking protective earth connections only.Functional earth connections shall not be madeby wires coloured green, yellow or green/yellowcombination.

P

2. ..........................................................................Add thefollowing new Note:

NOTE 3 Internal wires of other colours are not precludedfrom making protective earthing connections

(AS/NZS 60598.1:2013)

P

3.8 PROVISION OF EARTHING P

3.8 (7.2.11) Variation

Delete the third paragraph and replace with the following:

All conductors, whether internal or external, coloured green,yellow or green/yellow combination, shall only beconnected to an earthing terminal

(AS/NZS 60598.1:2013)

P

3.11 PROTECTION AGAINST ELECTRIC SHOCK P

Page 70: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 10 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.11 (8.2.1) Variation

Delete the first paragraph and Note 1 and replace with thefollowing:

Luminaires shall be so constructed that their live parts andbasic insulation are not accessible when the luminaire hasbeen installed and wired as in normal use. Live parts shallnot be accessible when the luminaire is opened asnecessary for replacing lamps, replaceable light sources or(replaceable) starters, even if the operation cannot beachieved by hand.

NOTE Examples of parts with basic insulation are cables

intended for internal wiring, controlgear for building-in etc.

This does not apply to the non-current -carrying parts ofcaps which comply with the relevant IEC safetystandard.

Where a protective cover is used over a non-user-replaceable light source to provide protection againstelectric shock, and the cover is marked with the “caution,electric shock risk” symbol in accordance with IEC 60417-6042, the cover shall be left in place during the tests andinspections detailed by Section 8 of this Standard. Thecover shall be held securely in position by fixings requiringthe use of a tool for their removal, and at least twoindependent fixings shall be used.

(AS/NZS60598.1:2013)

PP

3.12 ENDURANCE TEST AND THERMAL TEST P

3.12

(Table 12.1)Addition

Add the following new Note after Table 12.1

NOTE Luminaire manufacturers should consider the

maximum ambient air temperature in the vicinity of

components such as starting devices and electronic ballasts

or converters. Component performance specifications advise

manufacturers to mark or supply life data as maximum

ambient air temperature based on 50,000 hrs. This t-life is

often marked as ta and is the temperature of the air in the

vicinity of the component and is not related to the luminaire ta.

As such, luminaire manufacturers should measure air

temperature in the vicinity of such components, within the

luminaire, as even those complying with their tc point

measurements can still fail prematurely if t-life is exceeded.

P

3.15 RESISTANCE TO HEAT, FIRE AND TRACKING P

Page 71: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 11 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

3.15 (13.3) Variation

Delete Clause 13.3 and replace with the following:

13.3 Resistance to flame and ignition

Parts of non-metallic material shall be resistant to flameand ignition.

For materials other than ceramic, compliance is

checked by the tests of 13.3.1 and 13.3.2, 13.3.3 and

13.3.4, as appropriate.

This requirement does not apply to decorative trims,knobs, wiring insulation and other parts not likely to beignited or to propagate flames from inside the luminaire.

This Clause applies to all parts, including components,even if they have been tested to their own standard.

N/A

13.3.1 Parts of non-metallic material supporting

connections shall withstand the following test:Parts are subject to a test using a nickel-chromium glow-

wire.

The test apparatus and test procedure shall be those

described in AS/NZS 60695.2.10.

The glow wire is heated to 750 °C and applied to the

test sample for 30 s.

For all tests, any flame or glowing of the sample shall

extinguish within 30 s of withdrawing the glow-wire, and

any burning or molten drop shall not ignite a single

layer of tissue paper specified in 4.187 of ISO 4046-

4:2002, spread out horizontally 200 mm ± 5 mm below

the sample.

N/A

Page 72: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 12 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

13.3.2 All other parts of non-metallic material shall

withstand the following test:

Parts are subject to a test using a nickel-chromium

glow-wire.

The test apparatus and test procedure shall be those

described in AS/NZS 60695.2.10.

The glow wire is heated to 650 °C and applied to the

test sample for 30 s.

For all tests, any flame or glowing of the sample shall

extinguish within 30 s of withdrawing the glow-wire, and

any burning or molten drop shall not ignite a single

layer of tissue paper specified in 4.187 of ISO 4046-

4:2002, spread out horizontally 200 mm ± 5 mm below

the sample.

P

Page 73: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 13 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

13.3.3 During the application of the 750 °C glow wire

test of Clause 13.3.1, if a flame is produced that

persists for longer than 2 s, the luminaire is further

tested as follows:

The needle-flame test of AS/NZS 60695.11.5 is applied

to non-metallic parts that encroach within the envelope

of a vertical cylinder having a diameter of 20 mm and a

height of 50 mm above the point of application of the

glow wire. The needle flame is applied to the test

sample for 30 s.

Parts shielded by a barrier that meets the needle-flame

test of AS/NZS 60695.11.5 are not tested.

NOTE This requires the needle flame to be applied to all

parts likely to be impinged upon by the glow-wire flame within

the hypothetical envelope of a vertical cylinder positioned

above the point of application of the glow-wire. This applies to

all parts unless there is a barrier that passes the needle-

flame test and is within the cylinder and would protect the

part from the glow-wire flame.

The duration of burning shall not exceed 30 s after

removal of the test flame and any burning drop shall not

ignite the underlying parts or tissue paper specified in

4.187 of ISO 4046-4:2002, spread out horizontally200 mm ± 5 mm below the sample.

The needle-flame test is not carried out on parts that

are made of material classified as V-0 or V-1 according

to AS/NZS 60695.11.10. The sample of material

classified in accordance with AS/NZS 60695.11.10 shall

be no thicker than the relevant part.

N/A

13.3.4 PCBs in luminaires shall be subject to the

needle-flame test of AS/NZS 60695.11.5. The needle

flame shall be applied for 30 seconds to an edge of the

PCB at least 10 mm from a corner.

The duration of burning shall not exceed 15 s after

removal of the needle flame and any burning droplets

shall not ignite the tissue paper placed underneath the

PCB.

The needle-flame test is not carried out on PCBs made ofmaterial that is V-0 rated according toAS/NZS 60695.11.10.

(AS/NZS 60598.1:2013)

N/A

Page 74: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.4

Project No: 085-170503801-000Date: 2017-12-20Page: 14 of 14

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Bibliography Addition

Add the following reference

AS/NZS 60335.1, Household and similar electrical

appliances—Safety, Part 1: General requirements (IEC

60335-1 Ed 5, MOD)

IEC 60252, AC motor capacitors (all parts)

(AS/NZS 60598.1:2013)

N/A

Special national conditions (if any) N/A

10.6 (4.2A) Addition

Add the following new Clause after Clause 4.2:

4.2A Capacitors shall be of a type to ensure that anycapacitor failure results in a failsafe outcome (i.e. thecapacitor type will fail in the open-circuit mode only andis protected against fire or shock hazard).Capacitors shall be not less than Type B capacitors withmetal body and break action protection in accordance withIEC 61048 and IEC 61049. A capacitor complying withANCI/EIA-456-A shall comply with IEC 61049 andIEC 61048:2006 excluding the endurance test of 18.1.1.

NOTE Capacitors of Class S2 (formerly referred to as P2) of

IEC 60252 (all parts) do not meet the safety requirements of

a Type B capacitor.

In addition, capacitors shall have a minimum voltage ratingof 250 V at a temperature rating of 100 °C or 280 V at atemperature rating of 85 °C.

Capacitors likely to be permanently subjected to the supplyvoltage, and used for radio interference suppression or forvoltage dividing, shall comply with IEC 60384-14.

(AS/NZS 60598.1:2013)

N/A

Figure ZZ1

(AS/NZS 60598.1:2013)

N/A

Page 75: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.5

IEC TR 62778:2014

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 1 of 2

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

7 MEASUREMENT INFORMATION FLOW P

7.1 Basic flow P

‘Law of conservation of luminance’ applied P

Use of only true luminance/radiance values P

In case of luminaire:The light source is operated in the luminaire undersimilar conditions as when tested as a component

P

In case Ethr value for RG2 was established thepeak value was derived from angular lightdistribution

N/A

7.2 Conditions for the radiance measurement P

Standard condition applied(200mm distance, 0,011rad field of view)

P

Non-standard condition applied N/A

7.3 Special cases (I): Replacement by a lamp or LED module of another type N/A

Light source is a white light source N/A

Evaluation done based on highest luminance N/A

Evaluation done based on CCT value N/A

7.4 Special cases (II): Arrays and clusters of primary light sources N/A

LED package is evaluated as ................................ RG0 unlimited

RG1 unlimited

N/A

Ethr of LED package applies to array N/A

8 RISK GROUP CLASSIFICATION P

Risk group achieved: P

- .. Risk Group 0 unlimited N/A

- .. Risk Group 1 unlimited N/A

- Ethr ................................................... (lx):

Distance to reach RG1 .................... (m):

1130 lx

0.67 m

P

Page 76: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.5

IEC TR 62778:2014

Clause Requirement + Test Result - Remark Verdict

Project No: 085-170503801-000Date: 2017-12-20Page: 2 of 2

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

TABLE: Spectroradiometric measurement P

Measurement performed on: LED package

LED module

Lamp

Luminaire

Model number ..............................................LED SL-PQ 150W: 150W

Test voltage (V) ............................................240 for LED driver

Test current (mA) .........................................628

Test frequency (Hz) ......................................50

Ambient, t (°C) ..............................................25

Measurement distance................................. 20 cm

... cm

Source size ................................................. Non-small

Small : .... mm

Field of view ................................................ 100 mrad

11 mrad

1,7 mrad (for small sources)

Item Symbol

Units Result Remark

Correlated colour temperature CCT K 4000

x/y colour coordinates /

Blue light hazard radiance LB W/(m2•sr1) 12600

Blue light hazard irradiance EB W/m2 /

Luminance L cd/m2 /

Illuminance E lx /

Supplementary information:

Page 77: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.6Photo documentation

Project No: 085-170503801-000Date: 2017-12-20Page: 1 of 6

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Details of: General view for all models

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Details of: General view for all models

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Page 78: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.6Photo documentation

Project No: 085-170503801-000Date: 2017-12-20Page: 2 of 6

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Details of: General view for all models

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Details of: Fixed screw for connection of eathing bracket and metal enclosure

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Page 79: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.6Photo documentation

Project No: 085-170503801-000Date: 2017-12-20Page: 3 of 6

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Details of: General view for all models

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Details of: General view for all models

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Page 80: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.6Photo documentation

Project No: 085-170503801-000Date: 2017-12-20Page: 4 of 6

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Details of: General view for all models

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Details of: General view for all models

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Page 81: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.6Photo documentation

Project No: 085-170503801-000Date: 2017-12-20Page: 5 of 6

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Details of: LED driver EUP-150S105SV for 150W model

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Details of: LED driver EUP-150S070SV for 120W and 100W model

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom

Page 82: TEST REPORT IEC 60598-2-3 Luminaires Part 2: Particular ...Attachment 4: Australia and New Zealand NATIONAL DIFFERENCES of IEC 60598-2-3(13 pages) Attachment 5: IEC/TR 62778:2014(2

Attachment No.6Photo documentation

Project No: 085-170503801-000Date: 2017-12-20Page: 6 of 6

Telephone : +86 20 38320668Telefax : +86 20 38320478

http://www.tuv-sud.cn

TÜV SÜD Certification and Testing (China) Co., Ltd.Guangzhou Branch, TÜV SÜD Group

5F, Communication Building, 163 Pingyun Rd, HuangpuAve. West, Guangzhou, 501656, P.R.China

Details of: Earthing terminal

View:

[ ] general

[ ] front

[ ] rear

[ ] right

[ ] left

[ ] top

[ ] bottom