1
© by SEMIKRON B 14 – 124 0896 14.7 Bimetal Thermal Trips 240 V~ (30 V=) Dimensions in mm Switching temperature °C Ident No. 63 30095070 67 30095080 75 ± 3 % 30095090 80 30095100 85 30095110 90 30095120 95 30095130 118 ± 3,5 % 30095140 132 30095150 50 32306700 56 30095170 60 30095180 63 31804300 71 ± 3 % 30095190 75 31804400 80 30138940 85 31804600 90 30121480 95 30121470 100 ± 3,5 % 30116110 112 30116120 118 30121460 50 30137120 60 ± 3 % 30138420 80 30140550 85 30140540 Switching characteristics of the contact Working voltage 240 V~ 30 V= Maximum current 1 A 3 A Guaranteed swit- ching cycles 100 000 Insulation test voltage (rms) 2000 V~ for 2s 1) The contact is normally closed and will open at the switching temperature 2) The contact is normally open and will close at the switching temperature Recommended switching temperature of the thermal trip for the heatsinks K 1,1 and K 0,55 Types K 1,1 K 1,1 F K 0,55 K 0,55 F SKN 45 95 °C 67 °C - - SKN 70 - 90 °C - - SKN 100 118 °C 85 °C - - SKN 130 - 90 °C - - SKN 240 132 °C - - 75 °C SKN 320 - - - 95 °C SKT 40 80 °C 67 °C - - SKT 55 90 °C 67 °C - - SKT 80 95 °C 67 °C - - SKT 100 95 °C 67 °C - - SKT 130 95 °C 80 °C 90 °C 67 °C SKT 160 95 °C 80 °C 90 °C 67 °C SKT 215 - - 95 °C 75 °C SKT 250 - - 95 °C 75 °C

TERMOSTATO SEMIKRON

Embed Size (px)

DESCRIPTION

Ctalogo SEMIKRON de Termostatos.

Citation preview

Page 1: TERMOSTATO SEMIKRON

© by SEMIKRONB 14 – 124 0896

14.7 Bimetal Thermal Trips240 V~ (30 V=)

Dimensionsin mm

Switchingtemperature

°C

Ident No.

63 30095070

67 30095080

75 ± 3 % 30095090

80 30095100

85 30095110

90 30095120

95 30095130

118 ± 3,5 % 30095140

132 30095150

50 32306700

56 30095170

60 30095180

63 31804300

71 ± 3 % 30095190

75 31804400

80 30138940

85 31804600

90 30121480

95 30121470

100 ± 3,5 % 30116110

112 30116120

118 30121460

50 30137120

60 ± 3 % 30138420

80 30140550

85 30140540

Switching characteristics of the contact

Working voltage 240 V~ 30 V=

Maximum current 1 A 3 A

Guaranteed swit-ching cycles

100 000

Insulation testvoltage (rms)

2000 V~ for 2s

1) The contact is normally closed and willopen at the switching temperature

2) The contact is normally open and will close at the switching temperature

Recommended switching temperature of the thermal tripfor the heatsinks K 1,1 and K 0,55

Types K 1,1 K 1,1 F K 0,55 K 0,55 FSKN 45 95 °C 67 °C - -SKN 70 - 90 °C - -SKN 100 118 °C 85 °C - -SKN 130 - 90 °C - -SKN 240 132 °C - - 75 °CSKN 320 - - - 95 °CSKT 40 80 °C 67 °C - -SKT 55 90 °C 67 °C - -SKT 80 95 °C 67 °C - -SKT 100 95 °C 67 °C - -SKT 130 95 °C 80 °C 90 °C 67 °CSKT 160 95 °C 80 °C 90 °C 67 °CSKT 215 - - 95 °C 75 °CSKT 250 - - 95 °C 75 °C