TENDER CLIENT PROJECT AMENDMENTS CADFILE SCALE DRAWN ISSUE/ REVISION DATE CHECKED DWG No [email protected] Ph 02 6260 6395 Fax 02 6260 6413 10/68 Jardine Street KINGSTON ACT 2604 Eric Martin & Associates DRAWING TITLE ARCHITECT NOTE: DO NOT SCALE OFF DRAWING Eric Martin Registered Architect ACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391 EMA A V:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1 HCA PWDWC TENDER.rvt 10/08/2021 1:52:30 PM 1:500@A3 EM PM TENDER C COVER SHEET HIGH COURT OF AUSTRALIA LEVEL 1 PWDWC HIGH COURT OF AUSTRALIA 20017-A000/C 10/08/2021 PLAN 1 : 500 A210 AERIAL SOURCE ACTMAPI 1 HIGH COURT OF AUSTRALIA LEVEL 1 PROPOSED WORKS FOR A PWDWC Drawing List Sheet Number Drawing Name Current Revision Date A000 COVER SHEET C 10/08/2021 A001 SITE PLAN B 23/07/2021 A005 SPECIFICATION NOTES 01 A 23/07/2021 A007 FIXTURES & FINISHES A 23/07/2021 A010 EXISTING FLOOR PLAN B 23/07/2021 A050 DEMOLITION PLAN B 23/07/2021 A101 FLOOR PLAN NEW WORKS C 23/07/2021 A110 RCP EXISTING B 10/08/2021 A115 RCP DEMOLITION B 10/08/2021 A120 RCP NEW WORKS C 10/08/2021 A210 SECTIONS A 10/08/2021 A300 DETAIL ELEVATIONS FEMALE REST ROOM EXISTING B 23/07/2021 A301 DETAIL ELEVATIONS ACCESSIBLE TOILET EXISTING B 23/07/2021 A305 DETAIL ELEVATIONS FEMALE REST ROOM DEMOLITION B 23/07/2021 A306 DETAIL ELEVATIONS PARENTS ROOM DEMOLITION B 23/07/2021 A310 DETAIL ELEVATIONS NEW PWDWC C 23/07/2021 A311 DETAIL ELEVATIONS NEW PARENTS ROOM B 23/07/2021 A325 DETAIL SECTIONS 01 A999 SAFETY IN DESIGN REPORT A 23/07/2021 A 22/06/2021 INITIAL ISSUE B 23/07/2021 ISSUED FOR TENDER C 10/08/2021 ISSUED FOR TENDER

TENDER - cdn.hcourt.gov.au

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

30 P

M

1:500@A3

EM

PM

TENDER CCOVER SHEET

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A000/C

10/08/2021

PLAN 1 : 500A210 AERIAL SOURCE ACTMAPI

1

HIGH COURT OF AUSTRALIA LEVEL 1 PROPOSEDWORKS FOR A PWDWC

Drawing List

Sheet Number Drawing Name Current Revision Date

A000 COVER SHEET C 10/08/2021

A001 SITE PLAN B 23/07/2021

A005 SPECIFICATION NOTES 01 A 23/07/2021

A007 FIXTURES & FINISHES A 23/07/2021

A010 EXISTING FLOOR PLAN B 23/07/2021

A050 DEMOLITION PLAN B 23/07/2021

A101 FLOOR PLAN NEW WORKS C 23/07/2021

A110 RCP EXISTING B 10/08/2021

A115 RCP DEMOLITION B 10/08/2021

A120 RCP NEW WORKS C 10/08/2021

A210 SECTIONS A 10/08/2021

A300 DETAIL ELEVATIONS FEMALE REST ROOMEXISTING

B 23/07/2021

A301 DETAIL ELEVATIONS ACCESSIBLE TOILETEXISTING

B 23/07/2021

A305 DETAIL ELEVATIONS FEMALE REST ROOMDEMOLITION

B 23/07/2021

A306 DETAIL ELEVATIONS PARENTS ROOMDEMOLITION

B 23/07/2021

A310 DETAIL ELEVATIONS NEW PWDWC C 23/07/2021

A311 DETAIL ELEVATIONS NEW PARENTS ROOM B 23/07/2021

A325 DETAIL SECTIONS 01

A999 SAFETY IN DESIGN REPORT A 23/07/2021

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

C 10/08/2021 ISSUED FOR TENDER

STAIRNo. 10G.23

STAIRNo. 161.11

SERVICE DUCT

ELECTRICAL ROOM1.25

LIFT LOBBY1.01

EXHIBITION LOBBY

1.36

EXHIBITIONTHEATRE

1.03

OFFICE1.20

CAR PARK ENTRYLOBBY

1.18

DUMB-WATER G.F

KITCHEN STORE1.35

DUCT1.32

JUSTICE PRIVATEENTRY LOBBY

1.17

1.21

CARPARKCORRIDOR

1.27

DUCT ROOM1.14

EXHIBITIONAREA 1.12

MALE TOILET1.13

MALE RESTROOM

1.10

FEMALE RESTROOM

1.09

ACCESSIBLETOILET

1.06

FEMALE TOILET1.08

DUCT1.30

DUCT1.29

FIRE PASSAGE1.15

CLEANERS ROOM1.22

DUCT1.31

JUSTICES CARPARK1.23

STAIRNo. 13G.46

STAIRNo. 141.34

STAIRNo. 141.34

STAIRNo. 12G.71

STAIRNo. 1G.26

DUCT RISER FROMLEVEL 1

LIFT No. 2

RAMP 51.26

STAIRNo. 3

LIFT No.4

LIFT No.5

LIFT No. 1

SERVICES LIFT No.3

STAIRNo. 2G.02

KITCHEN1.24

STAIR11

G.45

RAMP 4G.59

DUCT

PLANT ROOM1G.22

STAIRNo. 3G.11

STORE1.16

PLANT ROOM 16AHU-24

1.04

?

ANNEX1.19

REGISTRYARCHIVES

1.02?

DUCT

STAIR29

G.72

Cleaners STORE

STORE1.33

COMMUNICATIONCUPBOARD

1.28

EXHIBITIONAREA

1.05EDUCATION

SPACE1.07

STAIRNo. 10G.23

STAIR21

1.38

STAIR28

1.39

UPUPUPUP

UP

UPUPUP

UP

UP

UP

UP DN

UP

UP

UP

UP

UP

UP

UP

LEVEL 1

AREA OF PROPOSED

NEW WORK

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

31 P

M

1:500@A3

EM

PM

TENDER BSITE PLAN

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A001/B

23/07/2021

PLAN 1 : 500A210 LEVEL 1 HIGH COURT

1

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

SECTION 02050 DEMOLITION

DEMOLISH ALL FIXTURES AND FINISHES INCLUDING THE CEILING AS

PER DEMOLITION DRAWINGS, INCLUDING MECHANICAL, ELECTRICAL

AND HYDRAULIC ENGINEERS SPECIFICATIONS RETAIN PLUMBING FOR

ADAPTION AS SPECIFIED IN THE HYDRAULIC ENGINEERS

SPECIFICATION

SECTION 02150 ASBESTOS REMOVAL

IF ASBESTOS MATERIAL IS DISCOVERED ON THE SITE AFTER WORK HAS

STARTED, THE WORK WILL BE CEASED IMMEDIATELY AND LICENSED PERSONS

ENGAGED TO REMOVE ASBESTOS-CONTAINING MATERIAL, CERTIFY ITS REMOVAL

AND RE-ISSUE AN ASBESTOS CLEARANCE CERTIFICATE.

SECTION 02510 WATER DISTRIBUTION

AS PER HYDRAULIC ENGINEERS SPECIFICATIONS

SECTION 02530 SANITARY SEWERAGE

AS PER HYDRAULIC ENGINEERS SPECIFICATIONS

SECTION 08460 AUTOMATIC SLIDING DOOR ASSEMBLIES

PROVIDE A SOLID CORE DOOR WITH AUTOMATIC POWER CONTROL. PROVIDE POWER

AS PER THE MANUFACTURERS SPECIFICATIONS. INCLUDE THE DORMAKABA DOOR

CONTROLLERS AS SHOWN ON THE ARCHITECTURAL PLANS AND ELEVATIONS.

PROVIDE POWER TO THE DOOR CONTROLLERS AND DOOR. PAINT FINISH DOOR AND

ENSURE THE IS SUITABLE LUMINANCE CONTRAST BETWEEN THE DOOR AND THE

WALL OR WALL AND DOOR FRAME. DEMOLISH THE EXISTING WALL AS NECESSARY TO

INSTALL THE NEW DOOR. ALL WORK TO BE CONDUCTED AS PER RELEVANT

AUSTRALIAN STANDARDS

SECTION 08850 MIRRORS

NEW SOLID GLASS MIRROR BONDED TO BACKING WITH NO

FRAME 700MM WIDE AND 950MM HIGH TO COMPLY WITH AS1428.1

TO BE INSTALLED ON THE WALL ABOVE THE BASIN. GROUND AND

POLISHED ON EXPOSED EDGES. FIX TO THE WALL WITH

APPROPRIATE FIXINGS AS PER MANUFACTURERS

SPECIFICATIONS.

SECTION 09300 CERAMIC TILE

SUPPLY AND INSTALL CERAMIC TILE WORK INCLUDING BUT NOT LIMITED TO

THE: SUITABLE PREPARATION OF SURFACES BEFORE TILING OR BEDDING AND

BEDDING SCREEDS WITH A SUITABLE WATERPROOF MEMBRANE. ALSO

INSTALL WALL TILES AND FLOOR TILES. CLEAN FINISHED TILED SURFACES

AND FOR TILE SPECIFICATIONS REFER TO FINISHES SCHEDULE. PROVIDE

SLOPE ON THE FLOOR TO THE FLOOR WASTE. INSTALL GROUT AND ENSURE

ALL WORK IS UNDERTAKEN IN ACCORDANCE OF AUSTRALIAN STANDARDS.

SECTION 09500 SUSPENDED CEILING

SUPPLY AND INSTALL A COMPLETE PLASTERBOARD SUSPENDED

CEILING FOR THE PWDWC. COORDINATE WITH MECHANICAL AND

ELECTRICAL SERVICES. INSTALL A 50mm CORNICE.

SECTION 09910 PAINTING

ALL EXPOSED PLASTERBOARD IS TO BE PRIMED AND PAINTED,

COLOUR TO BE CONFIRMED. ALL CEILINGS AND CORNICES ARE

TO BE PRIMED & PAINTED WITH CEILING WHITE. PAINT DOOR &

FRAME & WALL IN FEMALE TOILET

SECTION 15150 FLOOR DRAINS

BUILD IN FLOOR WASTE WITH TILES TO SLOPE

TOWARD THE FLOOR WASTE.

SECTION 16350 ELECTRICAL INSTALLATIONS

AS PER ELECTRICAL ENGINEERS SPECIFICATIONS

SECTION 16515 LOW VOLTAGE LIGHTING

AS PER ELECTRICAL ENGINEERS SPECIFICATIONS

SECTION 16710 COMMUNICATION CABLING

AS PER ELECTRICAL ENGINEERS SPECIFICATIONS

SECTION 15782 MECHANICAL SERVICES

AS PER MECHANICAL ENGINEERS SPECIFICATIONS

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

31 P

M

1:100@A3

EM

PM

TENDER ASPECIFICATION NOTES 01

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A005/A

23/07/2021

A 23/07/2021 ISSUED FOR TENDER

CAROMA BASIN OPAL 720 WALL BASIN RIGTH HAND SHELF

CAROMA ACQUA CARE BASIN MIXER 90989C5A

50mm COVED PLASTER CORNICE PAINTED CEILING WHITE

CLIPSAL 2000 SERIES - POWER TO AUTO DOOR TO COMPLY WITH AS3000 & AUTO DOOR MANUFACTURERES

SPECIFICATIONS

SOLID CORE DOOR 920mm LEAF MINIMUM AUTO OPERATED

FLOOR WASTE ART AUSTRALIA 316 STAINLESS STEEL 100mm SQUARE

MAIN GRABRAIL CAROMA CAARE SUPPORT GRABRAIL - 140 DEGREE ANGLED 870 X 700 LEFT HAND 687466SS

300mm GRABRAIL CAROMA CARE SUPPORT GRABRAIL - 300mm STRAIGHT 687471SS

HOOK RBA1622-120

CLIPSAL MOTION DETECTOR SWITCH WITH FAN AS PER ELECTRICAL ENGINEERS SPECIFICATIONS

MIRROR 700mm x 1050mm

MIRROR 1470mm x 890mm EXISTING

CAROMA CARE 800 CLEANFLUSH WALL FACED SUITE WITH BACKREST, CONTRASTING ANTHRACITE GREY

SEAT S TRAP ACCESSIBLE TO AS1428.1 PAN # 901920BAG

PAINTED PLASTERBOARD COLOR TO BE CONFIRMED

PAPER TOWEL DISPENSER METLAM STAINLESS STEEL ML725SS_MK2

SOAP DISPENSER METLAM STAINLESS STEEL ML605BS

200mm x 100mm x 6mm WALL TILES AS PER HIGH COURT NEW WORKS REQUIREMENTS TO BE CONFIRMED

100mm x 100mm FLOOR TILES AS PER HIGH COURT NEW WORKS REQUIREMENTS TO BE CONFIRMED

TOILET PAPER HOLDER METLAM 700_SS_TRH

WASTE PAPER TOWEL BIN - NOT TO ENROACH INTO CIRCULATION SPACE

BABY CHANGE TABLE HORIZONTAL KOALA KARE BABY CHANGE STATION KB200-SS

DYSON AIR BLADE V HAND DRYER

DORMAKABA AUTO DOOR OPERATION PAD EXTERNAL 205mm HIGH 230mm WIDE

DORMAKABA AUTO DOOR OPERATION PAD INTERNAL 265mm HIGH 230mm WIDE

BRAILLE TACTILE SIGNS PWDWC SIGN PART NUMBER BTS11LHn-AL-blu

BRAILLE TACTILE SIGNS UNISEX BABY CHANGE ROOM PART NUMBER BTS162n-blu

B1:

MX:

C:

GPO:

DOOR2:

FW:

GR1:

GR2:

HK:

MD:

M1:

M2:

PAN1:

PPB:

PTD:

SD:

T1:

FT:

TPH:

WPTB:

BCT:

HD:

ADOE:

ADOI:

SG1:

SG2:

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

32 P

M

1:100@A3

EM

PM

TENDER AFIXTURES & FINISHES

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A007/A

23/07/2021

A 23/07/2021 ISSUED FOR TENDER

3475

A300

1

2

3

4

A301

1

2

3

4

890

5155

2365

285

3330

285 11

519

2528

5

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

33 P

M

1:50@A3

EM

PM

TENDER BEXISTING FLOOR PLAN

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A010/B

23/07/2021

PLAN 1 : 50A210 GROUND FLOOR PLAN

1

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

A305

1

2

3

4

A306

1

2

3

4

1

A210

REMOVE WALL FOR NEW DOOR &

WALL TO PERMIT AUTO SLIDING DOOR

REMOVE FLOOR & WALL FINISHES & CEILINGS

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

33 P

M

1:50@A3

EM

PM

TENDER BDEMOLITION PLAN

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A050/B

23/07/2021

PLAN 1 : 50A210 DEMOLITION PLAN

1

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

A310

1

2

3

4

A311

1

2

3

4

905 870

1925

2365

2130

NEW BABY CHANGE TABLE (BCT)

RETAIN EXISTING POWER TO

AUTO DOOR, RETAIN DOOR &

RETAIN OPERABLE BUTTONS

NEW POWER OUTLET TO NEW SLIDING

AUTO DOOR

AUTO DOOR OPERABLE BUTTONS

INTERNAL (ADOI) & EXTERNAL (ADOE)

FW

BRICK UP WALL & FINISH INSIDE

TOILET SIDE TO MATCH EXISTING

WHERE SHADED

NEW FITOUT & FINISHES TO

ACCESSIBLE TOILET

1

A210

REPAINT EXISTING DOOR

NOTE:

COORDINATE PLUMBING SERVICES TO PROVIDE APPROPRIATE

SUPPLY OF WATER AND RELEASE OF WASTE WATER TO SEWER.

INSTALL NEW PLUMBING FIXTURES ON THE PLANS AND MIXER

ASSOCIATED WITH THE BASIN. INSTALL AS PER

MANUFACTURERS SPECIFICATIONS AND AUSTRALIAN

STANDARDS. CONNECT HOT AND COLD WATER TO THE MIXER ON

THE BASIN FROM EXISTING SERVICES INFRASTRUCTURE. SET

OUT PAN AND BASIN AS PER DRAWINGS AND AS1428.1. INCLUDE

IN THIS WORK THE CONNECTION OF THE FITTINGS TO FLOORS,

WALLS, OTHER FITTINGS, WASTE OUTLETS, WATER SUPPLY

PIPES AND VENT PIPES.

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

34 P

M

1:50@A3

EM

PM

TENDER CFLOOR PLAN NEW WORKS

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A101/C

23/07/2021

PLAN 1 : 50A210 GROUND FLOOR PLAN NEW WORKS

1

A 22/06/2021 INITIAL ISSUE

B 06/07/2021 GENERAL AMENDMENTS

C 23/07/2021 ISSUED FOR TENDER

SE

E

EXISTING MOTION DETECTOR TO REMAIN

EXISTING 600mm BATTEN

EXISTING EMERGENCY 600mm BATTEN

EXISTING SPEAKER TO REMAIN

EXISTING DUCT WORK

EXISTING WALL LAMP

EXISTING DUCT WORK

EXISTING DUCT WORK

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

35 P

M

1:50@A3

EM

PM

TENDER BRCP EXISTING

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A110/B

10/08/2021

REFLECTED CEILING PLAN1 : 50A210 RCP EXISTING

1

A 23/07/2021 ISSUED FOR TENDER

B 10/08/2021 ISSUED FOR TENDER

DEMOLISH WALL LAMP DEMOLISH 600mm LAMP & MAKE GOOD

DEMOLISH 600mm EMERGENCY LAMP

RETAIN WIRING & MAKE GOOD

DEMOLISH MECHANICAL DUCTING

DASHED FOR NEW SLIDING DOOR.

CAP OFF DUCTING AT THIS POINT

AS PER MECHANCIAL ENGINEERS

SPECIFICATIONS

DEMOLISH MECHANICAL DUCTING DASHED AS

PER MECHANICAL ENGINEERS SPECIFICATIONS

EXISTING MECHANICAL DUCTING

TO BE RETAINED

EXISTING DUCT

CUT DUCT AT THIS POINT TO ALLOW

FOR NEW DUCTING

REMOVE DUCTING IN THIS ROOM

DEMOLISH WALL TO ALLOW NEW AUTO DOOR

1

A210

DEMOLISH EXISTING CEILING INCLUDING

LIGHTS

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

36 P

M

1:50@A3

EM

PM

TENDER BRCP DEMOLITION

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A115/B

10/08/2021

REFLECTED CEILING PLAN1 : 50A210 RCP DEMOLITION

1

A 23/07/2021 ISSUED FOR TENDER

B 10/08/2021 ISSUED FOR TENDER

B

S

NEW SURFACE MOUNTED

MOTION SENSOR

NEW SPEAKER

NEW GPO FOR SLIDING AUTODOOR

RETAIN EXISTING MOTION CENTRE

NEW 1200mm EMERGENCY LAMP

RETAIN EXISTING GPO

S

RETAIN EXISTING SPEAKER

RETAIN EXISTING MECHANICAL DUCTING

(PURPLE) AS PER MECHANICAL ENGINEERS

SPECIFICATIONS

NEW WORK (BLUE) AS PER

MECHANICAL ENGINEERS

SPECIFICATIONS, VENTS TO

BE INSTALLED IN THE SIDE OF

THE DUCTING

NEW DUCT WORK (BLUE) AS PER MECHANICAL

ENGINEERS SPECIFICATIONS. VENTS TO BE

INSTALLED IN THE SIDE OF THE DUCTING

CAP OFF DUCT WORK AS PER

MECHANICAL ENGINEERS

SPECIFICATIONS

1

A210

NEW 1200mm EMERGENCY LAMP AS

PER ELECTRICAL ENGINEERS SPECS

INSTALL ALL APARATUS ON UNDERSIDE

OFCONCRETE CEILING, USING CONDUITS

& PAINT BOTH CONDUITS & CEILINGS

CEILING WHITE

NOTE:

LIGHTING, POWER & COMMUNICATIONS

SERVICES AS PER ELECTRICAL ENGINEERS

SPECIFICATIONS

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

37 P

M

1:50@A3

EM

PM

TENDER CRCP NEW WORKS

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A120/C

10/08/2021

REFLECTED CEILING PLAN1 : 50A210 RCP NEW WORKS

1

A 16/07/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

C 10/08/2021 ISSUED FOR TENDER

DO

OR

ME

CH

1000

NEW DORMAKABA EXTERNAL SLIDING AUTO

DOOR OPERATING SWITCH FOR NEW PWDWC NEW SLIDING SOLID CORE AUTO DOOR MUST

HAVE A MINIMUM OPENING CLEARANCE OF 850mm

RETAIN SLIDING AUTO DOOR &

OPERATING MECHANISM TO REPURPOSED

PARENTS ROOMMETAL DOOR FRAME TO MATCH

ADJACENT DOORS. PAINTED TO

MATCH EXISTING

CE

NT

RE

OF

SIG

NS

1400

(SG1) UNISEX LH PWDWC SIGN AS PER AS1428.1

(SG2) UNISEX BABY CHANGE SIGN

PRELIMINARY

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

37 P

M

1:50@A3

EM

PM

TENDER ASECTIONS

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A210/A

10/08/2021

SECTION 1 : 50A050 EXTERNAL WALL TO PWDWC & PARENTS ROOM

1

A 10/08/2021 ISSUED FOR TENDER

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

38 P

M

1:50@A3

EM

PM

TENDER BDETAIL ELEVATIONS FEMALE REST ROOMEXISTING

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A300/B

23/07/2021

ELEVATION 1 ELEVATION 2

ELEVATION 3 ELEVATION 4

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

1465

FFL Ground 0.000

FCL Ground 2.400

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

39 P

M

1:50@A3

EM

PM

TENDER BDETAIL ELEVATIONS ACCESSIBLE TOILETEXISTING

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A301/B

23/07/2021

ELEVATION 1 ELEVATION 2

ELEVATION 3 ELEVATION 4

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

FFL Ground 0.000

FCL Ground 2.400

DEMOLISH WALL TO FIT

NEW SLIDING AUTO DOOR

REMOVE EXISTING WALL TILES &

RETAIN WALL READY FOR NEW TILES

FFL Ground 0.000

FCL Ground 2.400

REMOVE DOOR & FRAME

REMOVE EXISTING WALL TILES &

RETAIN WALL READY FOR NEW TILES

FFL Ground 0.000

FCL Ground 2.400

REMOVE EXISTING WALL TILES &

RETAIN WALL READY FOR NEW TILES

FFL Ground 0.000

FCL Ground 2.400

REMOVE EXISTING WALL TILES &

RETAIN WALL READY FOR NEW TILES

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

40 P

M

1:50@A3

EM

PM

TENDER BDETAIL ELEVATIONS FEMALE REST ROOMDEMOLITION

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A305/B

23/07/2021

ELEVATION 1 ELEVATION 2

ELEVATION 3 ELEVATION 4

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

41 P

M

1:50@A3

EM

PM

TENDER BDETAIL ELEVATIONS PARENTS ROOM DEMOLITION

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A306/B

23/07/2021

ELEVATION 1 ELEVATION 2

ELEVATION 3 ELEVATION 4NOTE:

NO DEMOLITION WORK TO BE

CONDUCTED IN THIS ROOM

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

FFL Ground 0.000

FCL Ground 2.400

WASTE PAPER BIN

(NOT FIXED)

T1

NEW AUTO DOOR

SOLID CORE, PAINT

FINISHED.

FFL Ground 0.000

FCL Ground 2.400

AU

TO

DO

OR

1000

ADOI

C L

HO

OK

S

1300

HOOKS

T1

550

BRICK UP FORMER DOOR

AND TILE OVER. FINISH EXTERIOR

SIDE OF THE BRICKED IN DOOR

WAY TO MATCH EXISTING

FFL Ground 0.000

FCL Ground 2.400

T1

GR2

PAN1

TPH

FFL Ground 0.000

FCL Ground 2.400

1000

820

900

T1M1

BASIN B1

WPTB

MX

PAN 1

TPH

GR1

HD

PTD SD

950

TO

P O

F G

RA

B R

AIL

800

TOP OF GRAB RAIL

800mm AFFL

NOTE:

FOR FIXTURES & FINISHES DETAILS

REFER TO DRAWING A/315 & SCHEDULE

OF FINISHES

NOTE:

ALL DETAILS TO COMPLY

WITH AS1428.1

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

42 P

M

1:50@A3

EM

PM

TENDER CDETAIL ELEVATIONS NEW PWDWC

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A310/C

23/07/2021

ELEVATION 1 ELEVATION 2

ELEVATION 3 ELEVATION 4

A 22/06/2021 INITIAL ISSUE

B 06/07/2021 GENERAL AMENDMENTS

C 23/07/2021 ISSUED FOR TENDER

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

FFL Ground 0.000

FCL Ground 2.400

M2 BCT

FFL Ground 0.000

FCL Ground 2.400

NEW BABY CHANGE TABLE.

INSTALL AS PER AS1428.1

NOTE:

FOR FIXTURES & FINISHES DETAILS

REFER TO DRAWING A/315 & SCHEDULE

OF FINISHES

NOTE:

ALL FIXTURES IN THE REALLOCATED

PARENTS ROOM ARE TO REMAIN

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

43 P

M

1:50@A3

EM

PM

TENDER BDETAIL ELEVATIONS NEW PARENTS ROOM

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A311/B

23/07/2021

ELEVATION 1 ELEVATION 2

ELEVATION 3 ELEVATION 4

A 22/06/2021 INITIAL ISSUE

B 23/07/2021 ISSUED FOR TENDER

SAFETY IN DESIGN REPORT__________________________________________________________________

ARE THERE ANY ADDITIONAL HAZARDS AND

RISKS NOT NORMALLY ASSOCIATED WITH THE

TYPE OF WORK DETAILS IN THE

DOCUMENTATION?

YES NO

HAVE YOU AND THE FOLLOWING PROJECT CONSULTANTS

IDENTIFIED ANY SAFETY RISKS ASSOCIATED WITH THE

WORKS? IF SO, PROVIDE DETAILS.

YES NO

NOTE: LIKELIHOOD - UNLIKELY, POSSIBLE, LIKELY, ALMOST CERTAIN.

SEVERTY - MINOR, LOW, MODERATE. EXTREME

TENDER

CLIENT PROJECTAMENDMENTS CADFILE

SCALE DRAWN

ISSUE/ REVISIONDATE

CHECKED DWG [email protected] 02 6260 6395 Fax 02 6260 641310/68 Jardine Street KINGSTON ACT 2604Eric Martin & Associates

DRAWING TITLE

ARCHITECT

NOTE: DO NOT SCALE OFF DRAWING

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

EMAAV:\Projects 2020\20017 High Court of Australia\I Tendering\20017 Level 1HCA PWDWC TENDER.rvt

10/0

8/20

21 1

:52:

45 P

M

1:100@A3

EM

PM

TENDER ASAFETY IN DESIGN REPORT

HIGH COURT OF AUSTRALIALEVEL 1 PWDWC

HIGH COURT OFAUSTRALIA

20017-A999/A

23/07/2021

SAFETY IN DESIGN REPORT - ARCHITECTURAL

RISK HAZARD LIKELIHOOD OF RISK CONSEQUENCES / SEVERITY CONTROL MEASURES

2 ASBESTOS POSSIBLE HIGH CONFIRM WITH BUILDING MANAGMENT WEREASBESTOS HAS BEEN IDENTIFIED AND ADVISE BUILDINGMANAGEMENT WHERE ASBESTOS HAS BEENIDENTIFIED IN THE COURSE OF UNDERTAKING BUILDINGWORKS

ARCHITECTURAL CONDUCTING CONSTRUCTIONWORK IN A BUILDING THAT WILL BEOPERATING

ALMOST CERTAIN HIGH COORDINATE WITH BUILDING MANAGEMENT TOCONFIRM PROCESS FOR ACCESSING SITE, REMOVINGDEMOLISHED DEBRIS BRINGING INTO THE BUILDINGNEW EQUIPMENT AND TO ALSO MINIMISECONSTRUCTION NOISE

X

N

A 23/07/2021 ISSUED FOR TENDER

LEVEL 1 EXISTING PWDWC

LEVEL 1 NEW PWDWC

·

·

EMA

[email protected] 02 6260 6395 Fax 02 6260 6413

10/68 Jardine Street KINGSTON ACT 2604

Eric Martin & Associates

Eric Martin Registered ArchitectACT 376 VIC 5150 NSW 5991 WA 1663 QLD 3391

FOR TENDER

SITE OF WORKS

AutoCAD SHX Text
e1
AutoCAD SHX Text
e3
AutoCAD SHX Text
GENERAL NOTES - GROUND LEVEL PWDWC 1. NO EXISTING DRAINAGE PLAN AVAILABLE. LOCATE AND CONFIRM EXISTING NO EXISTING DRAINAGE PLAN AVAILABLE. LOCATE AND CONFIRM EXISTING WC DRAINAGE ALIGNMENT PRIOR TO COMMENCEMENT OF WORKS. 2. CONFIRM EXISTING HOT AND COLD WATER ARE EXTENDED TO WC & BASIN.CONFIRM EXISTING HOT AND COLD WATER ARE EXTENDED TO WC & BASIN.
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
eFW
AutoCAD SHX Text
eVP
AutoCAD SHX Text
~
AutoCAD SHX Text
e1
AutoCAD SHX Text
e1
AutoCAD SHX Text
e3
AutoCAD SHX Text
eVP
AutoCAD SHX Text
e3
AutoCAD SHX Text
e3
AutoCAD SHX Text
eFW
AutoCAD SHX Text
~
AutoCAD SHX Text
GROUND LEVEL BELOW
AutoCAD SHX Text
High Court
AutoCAD SHX Text
of
AutoCAD SHX Text
Australia
AutoCAD SHX Text
National Gallery
AutoCAD SHX Text
Australia
AutoCAD SHX Text
28
AutoCAD SHX Text
1
AutoCAD SHX Text
6
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
6
AutoCAD SHX Text
13
AutoCAD SHX Text
GENERAL NOTES - GROUND LEVEL PWDWC NEW WORKS 1. LOCATE AND CONNECT TO EXISTING DRAINAGE DOWNSTREAM OF EXISTING WC. LOCATE AND CONNECT TO EXISTING DRAINAGE DOWNSTREAM OF EXISTING WC. 2. LOCATE AND CONNECT TO EXISTING HOT & COLD WATER SERVICES TO EXISTING LOCATE AND CONNECT TO EXISTING HOT & COLD WATER SERVICES TO EXISTING ACCESSIBLE TOILET ROOM 1.06 AND EXTEND TO NEW WC & BASIN INCLUDING NEW THERMOSTATIC MIXING VALVE. 3. THERMOSTATIC MIXING VALVE IN STEEL CABINET. REFER TO DETAIL A.THERMOSTATIC MIXING VALVE IN STEEL CABINET. REFER TO DETAIL A.
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
FW
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
e1
AutoCAD SHX Text
e3
AutoCAD SHX Text
eFW
AutoCAD SHX Text
eVP
AutoCAD SHX Text
~
AutoCAD SHX Text
e1
AutoCAD SHX Text
e1
AutoCAD SHX Text
e3
AutoCAD SHX Text
eVP
AutoCAD SHX Text
e3
AutoCAD SHX Text
e3
AutoCAD SHX Text
eFW
AutoCAD SHX Text
~
AutoCAD SHX Text
2
AutoCAD SHX Text
GROUND LEVEL BELOW
AutoCAD SHX Text
3
AutoCAD SHX Text
0m
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
1:100 @A1
AutoCAD SHX Text
4
AutoCAD SHX Text
1:200 @A3
AutoCAD SHX Text
5
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED BY
AutoCAD SHX Text
DESIGNED BY
AutoCAD SHX Text
AUTHORISED BY
AutoCAD SHX Text
PROJECT TITLE
AutoCAD SHX Text
ISSUE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
11
AutoCAD SHX Text
10
AutoCAD SHX Text
9
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
6
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
12
AutoCAD SHX Text
11
AutoCAD SHX Text
10
AutoCAD SHX Text
9
AutoCAD SHX Text
7
AutoCAD SHX Text
6
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
12
AutoCAD SHX Text
G
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
H
AutoCAD SHX Text
PROJECT LOCATION
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
DATE
AutoCAD SHX Text
G
AutoCAD SHX Text
F
AutoCAD SHX Text
E
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
H
AutoCAD SHX Text
DO NOT SCALE OFF DRAWINGS VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING WORK.
AutoCAD SHX Text
CLIENT
AutoCAD SHX Text
ARCHITECT
AutoCAD SHX Text
COPYRIGHT:THE CONCEPTS AND INFORMATION CONTAINED IN THIS DOCUMENT ARE COPYRIGHT OF SELLICK THE CONCEPTS AND INFORMATION CONTAINED IN THIS DOCUMENT ARE COPYRIGHT OF SELLICK CONSULTANTS. USE OR COPYING OF THIS DOCUMENT IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION PERMISSION CONSTITUTES AN INFRINGEMENT OF COPYRIGHT.
AutoCAD SHX Text
REV.
AutoCAD SHX Text
200152
AutoCAD SHX Text
BLOCK 15 SECTION 28
AutoCAD SHX Text
PARKES
AutoCAD SHX Text
HIGH COURT OF AUSTRALIA
AutoCAD SHX Text
HIGH COURT OF AUSTRALIA
AutoCAD SHX Text
%%UDRAINAGE PLAN NUMBER:
AutoCAD SHX Text
DESIGNED TO AS3500
AutoCAD SHX Text
%%uPLAN OF SANITARY DRAINAGE
AutoCAD SHX Text
%%UDRAINAGE AND WATER SUPPLY
AutoCAD SHX Text
ALL WORK MUST BE CARRIED OUT IN CONFORMITY WITH THE WATER AND SEWER ACT 2000 AND THE WATER AND SEWERAGE REGULATIONS 2001.
AutoCAD SHX Text
THE PLUMBING AND DRAINAGE IS DESIGN TO AS/NZS 3500 PLUMBING STANDARDS.
AutoCAD SHX Text
%%UPLAN OF SANITARY DRAINAGE
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
SUBURB
AutoCAD SHX Text
OWNER
AutoCAD SHX Text
BLOCK
AutoCAD SHX Text
HIGH COURT OF AUSTRALIA
AutoCAD SHX Text
15
AutoCAD SHX Text
28
AutoCAD SHX Text
PARKES
AutoCAD SHX Text
PLUMBING PLAN APPROVED
AutoCAD SHX Text
APPROVED BY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REG. NUMBER
AutoCAD SHX Text
H200
AutoCAD SHX Text
HYDRAULIC SERVICES
AutoCAD SHX Text
LEVEL1 G/A
AutoCAD SHX Text
DO
AutoCAD SHX Text
BW
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
ISSUED FOR TENDER REVIEW
AutoCAD SHX Text
01.07.20
AutoCAD SHX Text
DO
AutoCAD SHX Text
2
AutoCAD SHX Text
ISSUED FOR TENDER
AutoCAD SHX Text
10.08.21
AutoCAD SHX Text
DO
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text
%%UPIPING SYMBOLS
AutoCAD SHX Text
%%UHYDRAULIC SERVICE MATERIALS NOTES
AutoCAD SHX Text
%%UABBREVIATIONS
AutoCAD SHX Text
%%ULEGEND
AutoCAD SHX Text
%%ULEADERS
AutoCAD SHX Text
%%UWATER SUPPLY NOTES
AutoCAD SHX Text
%%UFIRE SEALING OF PENETRATIONS NOTES
AutoCAD SHX Text
1.
AutoCAD SHX Text
14.
AutoCAD SHX Text
1.
AutoCAD SHX Text
2.
AutoCAD SHX Text
3.
AutoCAD SHX Text
4.
AutoCAD SHX Text
%%UVERTICAL PIPES
AutoCAD SHX Text
HYDRAULIC DRAWINGS SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND CIVIL WORKS DRAWINGS AND THE BUILDING HYDRAULICS SPECIFICATION.
AutoCAD SHX Text
THE LOCATIONS OF EXISTING SERVICES SHOWN ARE APPROXIMATE ONLY. EXACT LOCATION OF SERVICES SHALL BE VERIFIED PRIOR TO COMMENCEMENT OF WORK.
AutoCAD SHX Text
MINIMUM GRADES ON 100 AND 150 STORMWATER DRAINS SHALL BE 1.00% 100 AND 150 STORMWATER DRAINS SHALL BE 1.00% 150 STORMWATER DRAINS SHALL BE 1.00% UNLESS SHOWN OTHERWISE.
AutoCAD SHX Text
ALL STORMWATER JUNCTIONS SHALL BE CARRIED OUT IN ACCORDANCE WITH TABLE "JUNCTION TYPES" SHOWN ON URBAN STORMWATER STANDARD DRAWING ST-0001.
AutoCAD SHX Text
COVER LEVELS ON MANHOLES AND SUMPS SHALL BE VERIFIED BY THE SUPERINTENDENT PRIOR TO THE CONSTRUCTION OF THE TOP SECTIONS OF THE STRUCTURES. THE CONTRACTOR SHALL ALLOW TO CONSTRUCT THE COVERS ON A SLOPE TO SUIT THE FINAL SURFACE SHAPES.
AutoCAD SHX Text
WHERE uPVC PIPES PENETRATE FIRE RATED WALLS OR SLABS, THEY SHALL BE PROVIDED WITH AN APPROVED FIRE RATED COLLAR, HAVING THE SAME FIRE RATING AS THE ELEMENT BEING PENETRATED.
AutoCAD SHX Text
WHERE SERVICES OTHER THAN uPVC PENETRATE CONCRETE OR MASONRY FIRE RATED BUILDING ELEMENTS, SEAL GAP BETWEEN SERVICES AND ELEMENT WITH AN APPROVED SILICON FIRE-STOP FOAM HAVING A FIRE RATING EQUAL TO THAT OF THE ELEMENT BEING PENETRATED.
AutoCAD SHX Text
SANITARY AND STORMWATER DRAINAGE SHALL BE SUPPORTED ON OR FROM SOLID GROUND IN ACCORDANCE WITH AS3500.
AutoCAD SHX Text
ALL DRAINAGE AND WATER SERVICES TO BE ABANDONED SHALL BE SEALED TO APPROVAL.
AutoCAD SHX Text
EXISTING SERVICE CONNECTION POINTS SHALL BE LOCATED ON SITE AND VERIFIED PRIOR TO COMMENCEMENT OF WORK.
AutoCAD SHX Text
1.
AutoCAD SHX Text
4.
AutoCAD SHX Text
5.
AutoCAD SHX Text
6.
AutoCAD SHX Text
7.
AutoCAD SHX Text
9.
AutoCAD SHX Text
10.
AutoCAD SHX Text
11.
AutoCAD SHX Text
12.
AutoCAD SHX Text
13.
AutoCAD SHX Text
ALL WORK MUST BE CARRIED OUT IN CONFORMITY WITH THE WATER AND SEWERAGE ACT 2000 AND THE WATER AND SEWERAGE REGULATIONS 2001.
AutoCAD SHX Text
2.
AutoCAD SHX Text
3.
AutoCAD SHX Text
ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH AS3500.
AutoCAD SHX Text
PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE SEALED TO PROVIDE A TWO HOUR FRL TO AS1530 PART 4 - 2005.
AutoCAD SHX Text
EXISTING DRAINS UNDER NEW BUILDINGS SHALL BE RE-TESTED.
AutoCAD SHX Text
ALL WORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH AS3500.
AutoCAD SHX Text
COPPER TUBES AND FITTINGS SHALL COMPLY WITH AS1432 - 2004 TYPE "B" TUBES (WATER SUPPLY) AND TYPE "A" TUBES (FIRE SUPPLY).
AutoCAD SHX Text
ALL CONNECTIONS BETWEEN DISSIMILAR PIPE MATERIALS SHALL BE MADE WITH APPROVED MANUFACTURED FITTINGS.
AutoCAD SHX Text
SIZES SHOWN ARE INDICATIVE ONLY. THE PRESSURE AT ALL WATER OUTLETS ARE NOT TO EXCEED 500kPa IN ACCORDANCE WITH AS3500. PRESSURE REDUCTION IS TO BE ACHIEVED BY UTILIZING PRESSURE REDUCTION STATIONS.
AutoCAD SHX Text
HIGH DENSITY POLYETHYLENE
AutoCAD SHX Text
DUCTILE IRON CEMENT LINED
AutoCAD SHX Text
UNPLASTICISED POLYVINYL CHLORIDE
AutoCAD SHX Text
COPPER
AutoCAD SHX Text
HDPE
AutoCAD SHX Text
uPVC
AutoCAD SHX Text
DICL
AutoCAD SHX Text
Cu
AutoCAD SHX Text
FINISHED FLOOR LEVEL
AutoCAD SHX Text
FFL
AutoCAD SHX Text
HC
AutoCAD SHX Text
H/L
AutoCAD SHX Text
H
AutoCAD SHX Text
FS
AutoCAD SHX Text
FH
AutoCAD SHX Text
FGL
AutoCAD SHX Text
FINISHED GROUND LEVEL
AutoCAD SHX Text
HOSE COCK
AutoCAD SHX Text
HYDRANT
AutoCAD SHX Text
HIGH LEVEL
AutoCAD SHX Text
FIRE HYDRANT
AutoCAD SHX Text
FIRE SERVICE
AutoCAD SHX Text
STOP VALVE
AutoCAD SHX Text
SV
AutoCAD SHX Text
DT
AutoCAD SHX Text
DP
AutoCAD SHX Text
DISCONNECTOR TRAP
AutoCAD SHX Text
DOWN PIPE
AutoCAD SHX Text
MH
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
OVER FLOW
AutoCAD SHX Text
O/F
AutoCAD SHX Text
INSPECTION OPENING
AutoCAD SHX Text
IO
AutoCAD SHX Text
GV
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
SEWER MANHOLE
AutoCAD SHX Text
SMH
AutoCAD SHX Text
STORMWATER MANHOLE
AutoCAD SHX Text
SWMH
AutoCAD SHX Text
INVERT LEVEL
AutoCAD SHX Text
IL
AutoCAD SHX Text
e
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
CW
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HW
AutoCAD SHX Text
l/s
AutoCAD SHX Text
LITRES PER SECOND
AutoCAD SHX Text
GS
AutoCAD SHX Text
GRATED SUMP
AutoCAD SHX Text
OVER FLOW RELIEF GULLY
AutoCAD SHX Text
ORG
AutoCAD SHX Text
FW
AutoCAD SHX Text
FLOOR WASTE
AutoCAD SHX Text
VENT PIPE
AutoCAD SHX Text
VP
AutoCAD SHX Text
STORMWATER
AutoCAD SHX Text
SW
AutoCAD SHX Text
F/A
AutoCAD SHX Text
FROM ABOVE
AutoCAD SHX Text
F/B
AutoCAD SHX Text
FROM BELOW
AutoCAD SHX Text
T/A
AutoCAD SHX Text
TO ABOVE
AutoCAD SHX Text
T/B
AutoCAD SHX Text
TO BELOW
AutoCAD SHX Text
DRG
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
NG
AutoCAD SHX Text
NATURAL GAS
AutoCAD SHX Text
OR REGULATING VALVE
AutoCAD SHX Text
ISOLATION VALVE
AutoCAD SHX Text
REDUCER
AutoCAD SHX Text
DROPPER OR JUMP UP
AutoCAD SHX Text
1.
AutoCAD SHX Text
3.
AutoCAD SHX Text
4.
AutoCAD SHX Text
SANITARY DRAINAGE - ALL uPVC CLASS "DWV" SHALL BE TO AS1260, PARTS 1 TO 4 - 2002, SOLVENT WELDED JOINTS EXCEPT WHERE EXPANSION JOINTS ARE REQUIRED.
AutoCAD SHX Text
ALL INTERNAL AND EXTERNAL WATER SERVICES AND FITTINGS SHALL BE TYPE "B" COPPER TUBING TO AS1432 - 2004.
AutoCAD SHX Text
STORMWATER - ALL 100 AND 150 PIPES SHALL BE uPVC TO AS1260, PARTS 1 TO 4 - 2002, 100 AND 150 PIPES SHALL BE uPVC TO AS1260, PARTS 1 TO 4 - 2002, 150 PIPES SHALL BE uPVC TO AS1260, PARTS 1 TO 4 - 2002, SOLVENT WELDED JOINTS EXCEPT WHERE EXPANSION JOINTS ARE REQUIRED
AutoCAD SHX Text
2.
AutoCAD SHX Text
SANITARY PLUMBING - uPVC TYPE "DWV" SHALL BE TO AS1260, PARTS 1 TO 4 - 2002 SOLVENT WELDED JOINTS EXCEPT WHERE EXPANSION JOINTS ARE REQUIRED.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
REMOVED OR ABANDONED
AutoCAD SHX Text
EXISTING TO BE
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
NEW
AutoCAD SHX Text
SANITARY DRAINAGE
AutoCAD SHX Text
STORMWATER
AutoCAD SHX Text
POLYETHYLENE
AutoCAD SHX Text
PE
AutoCAD SHX Text
SERVICE
AutoCAD SHX Text
PIPE SIZE
AutoCAD SHX Text
FU
AutoCAD SHX Text
FIXTURE UNITS
AutoCAD SHX Text
WATER METER
AutoCAD SHX Text
WM
AutoCAD SHX Text
FHR
AutoCAD SHX Text
FIRE HOSE REEL
AutoCAD SHX Text
SEWER RISING MAIN
AutoCAD SHX Text
SRM
AutoCAD SHX Text
GAS
AutoCAD SHX Text
FIRE SERVICE
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
VENT PIPE
AutoCAD SHX Text
15.
AutoCAD SHX Text
ORG LEVELS ARE TO BE IN ACCORDANCE WITH AS3500.2.2 CLAUSE 4.6.6.6 AND 4.6.6.7 AND ACTPLA PLUMBING NOTE 22.
AutoCAD SHX Text
%%UHEALTH AND SAFETY
AutoCAD SHX Text
1.
AutoCAD SHX Text
THE MAIN CONTRACTOR AND ALL SUB-CONTRACTORS SHALL COMPLY WILL APPLICABLE HEALTH AND SAFETY CODES OF PRACTICE, GUIDANCE NOTES, AUSTRALIAN STANDARDS AND OTHER RELEVANT DOCUMENTATION.
AutoCAD SHX Text
2.
AutoCAD SHX Text
CURRENT LEGISLATION REQUIRES THAT ALL PERSONS ARE TO CONSIDER THEIR ACTIONS OR LACK OF ACTION ON THE HEALTH AND SAFETY OF THEMSELVES AND OTHERS. ADVICE ON SAFETY LEGISLATION IS AVAILABLE FROM THE HEALTH AND SAFETY EXECUTIVE OFFICER NOMINATED FOR THE PROJECT.
AutoCAD SHX Text
3.
AutoCAD SHX Text
THE MAIN CONTRACTOR AND ALL SUB-CONTRACTORS SHALL IDENTIFY HAZARDS OR WORK SEQUENCES THAT MAY BE A RISK TO THE HEATH AND SAFETY OF CONSTRUCTION WORKERS. IF POSSIBLE, AVOID THE RISK COMPLETELY, IF NOT, ADVISE THE SITE MANAGEMENT FOR INCLUSION IN THE HEALTH AND SAFETY PLAN.
AutoCAD SHX Text
4.
AutoCAD SHX Text
THE MAIN CONTRACTOR AND ALL SUB-CONTRACTORS SHALL CARRY OUT RISK ASSESSMENTS FOR ALL OF THEIR ACTIVITIES AND WHERE NECESSARY INTRODUCE SUITABLE CONTROL MEASURES, OR PROVIDE PROTECTIVE CLOTHING TO MINIMISE THOSE RISKS. COPIES OF RISK ASSESSMENTS MUST BE PROVIDED TO THE SITE MANAGEMENT FOR INSPECTION.
AutoCAD SHX Text
6.
AutoCAD SHX Text
ALL PIPE WORK SHALL BE CONCEALED. WHERE PIPE WORK IS EXPOSED IT SHALL BE CHROME PLATED.
AutoCAD SHX Text
5.
AutoCAD SHX Text
ALL ISOLATION VALVES SHALL BE POSITIONED IN APPROVED ACCESSIBLE LOCATIONS. VALVES LOCATED IN DUCTS OR WALLS SHALL BE POSITIONED WITH APPROVED TYPE ACCESS COVERS.
AutoCAD SHX Text
16.
AutoCAD SHX Text
THESE DRAWINGS ARE STRICTLY COPYRIGHT AND SHALL NOT BE COPIED OR AMENDED WITHOUT THE WRITTEN CONSENT OF SELLICK CONSULTANTS PTY LTD.
AutoCAD SHX Text
17.
AutoCAD SHX Text
CONTRACTOR SHALL PROVIDE 'WORK AS EXECUTED' DRAWINGS AND PAY ALL ASSOCIATED FEES AT THE COMPLETION OF THE HYDRAULIC WORKS.
AutoCAD SHX Text
POINT
AutoCAD SHX Text
DP
AutoCAD SHX Text
100
AutoCAD SHX Text
f/a
AutoCAD SHX Text
t/b
AutoCAD SHX Text
FROM ABOVE
AutoCAD SHX Text
TO BELOW
AutoCAD SHX Text
FIXTURE No
AutoCAD SHX Text
FIXTURE NAME
AutoCAD SHX Text
No OFF - DELETED
AutoCAD SHX Text
1
AutoCAD SHX Text
WATER CLOSET
AutoCAD SHX Text
2
AutoCAD SHX Text
BATH
AutoCAD SHX Text
-
AutoCAD SHX Text
3
AutoCAD SHX Text
BASIN
AutoCAD SHX Text
4
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
5
AutoCAD SHX Text
KITCHEN SINK
AutoCAD SHX Text
8
AutoCAD SHX Text
CLEANERS SINK
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
2
AutoCAD SHX Text
%%USANITARY FIXTURES
AutoCAD SHX Text
TV
AutoCAD SHX Text
TEMPERING VALVE
AutoCAD SHX Text
TEMPERING VALVE
AutoCAD SHX Text
No OFF - NEW
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
%%ULOCALITY PLAN
AutoCAD SHX Text
%%ULEVEL 1 - EXISTING SERVICES
AutoCAD SHX Text
%%ULEVEL 1 - GENERAL ARRANGEMENT
AutoCAD SHX Text
%%UDETAIL
AutoCAD SHX Text
%%UTHERMOSTATIC MIXING VALVE
AutoCAD SHX Text
SCALE 1:10
AutoCAD SHX Text
%%UPLAN
AutoCAD SHX Text
%%C20
AutoCAD SHX Text
%%C20
AutoCAD SHX Text
%%C20
AutoCAD SHX Text
OUTLET TESTPOINT
AutoCAD SHX Text
%%UFRONT ELEVATION
AutoCAD SHX Text
-
AutoCAD SHX Text
A
AutoCAD SHX Text
AQUABLEND 1500 ATM 700, 20mm THERMOSTATIC MIXING VALVE WITH INBUILT STOP COCKS, NON-RETURN VALVES AND STRAINERS
AutoCAD SHX Text
STAINLESS STEEL RECESSED CABINET MODEL No. ATMS700R (LOCKABLE)

DBN

EM

AN

EM

ADAD

SURFACE CONDUIT TOFITTINGS

NEW DOOR CONTROLS TO BECOORDINATED WITH DOOR INSTALLER

500

EW

AD

EXISTING CONTROLS

FITTINGS TO BE DEMOLISHED.PATCH AND PAINT PERARCHITECTURALREQUIREMENTS

E

EE

W

DBN

EMAN

EM

AD

EXISTING FLUORESCENT WALL OYSTER LIGHT

EXISTING 600mm DIFFUSED BATTEN

EXISTING 1200mm DIFFUSED EMERGENCYLIGHTING BATTEN

NEW IN EXISTING LOCATION 1200mm DIFFUSEDEMERGENCY LIGHTING BATTEN EQUAL TOCLEVERTRONICS CBS4LEDS-DIF-HV

NEW IN NEW LOCATION 1200mm DIFFUSEDEMERGENCY LIGHTING BATTEN EQUAL TOCLEVERTRONICS CBS4LEDS-DIF-HV

EXISTING LIGHT SWITCH

SURFACE MOUNTED EWIS SPEAKER. GREY FOR EXISTING

SURFACE MOUNTED 90° PIR MOTION SENSOR EQUAL TOCLIPSAL 751R. GREY FOR EXISTING

10A DOUBLE SOCKET OUTLET FOR AUTO DOOR. GREYFOR EXISTING

EXISTING CAT 3 DAT OUTLET TO BE DEMOLISHED.PROVIDE BLANKING PLATE

AUTO DOOR CONTROLS. MIN. 500mm FROMINTERNAL CORNERS

Conditions of Use. This document may only be used by GHD's client (and any otherperson who GHD has agreed can use this document) for the purpose for which it wasprepared and must not be used by any other person or for any other purpose.

Level 7, 16 Marcus Clarke Street

Canberra ACT 2601 Australia

GPO Box 1877 Canberra ACT 2601

T 61 2 6113 3200 F 61 2 6113 3299

E [email protected] W www.ghd.com

Plot Date: File Name:12 August 2021 - 2:02 PM \\ghdnet\GHD\AU\Canberra\Projects\23\12552620\CADD\Drawings\12552620-E001.dwg

Plotted by:

Chathurika Peiris

Project No.

www.ghd.com

Drawing No.

DrawingTitle

Client

Project

Status

Rev Description Checked Approved Date

Author Drafting Check

Designer Design CheckStatusCode

Size

Rev

A3HIGH COURT OF AUSTRALIA

GROUND FLOOR PWD WC

TENDER

ELECTRICAL SERVICESDEMO AND PROPOSED LAYOUTS

12552620 12552620-E001 1C. PEIRISC. PEIRIS T. LITTLE

0 FOR TENDER ER TL 09.08.211 FOR TENDER ER TL 12.08.21

-

1. GENERAL SPECIFICATION NOTES1.1 INFORMATIONTHE CONTRACTOR IS TO FULLY INFORM THEMSELVES OF ALL ASPECTSOF THIS EXISTING INSTALLATION PRIOR TO TENDER &COMMENCEMENT OF CONSTRUCTION. UNDERTAKE A MANDATORYSITE INSPECTION TO ASSESS THE SCOPE OF DEMOLITION AND NEWWORKS.

1.2 CODES, RULES, PERMITS, FEESALL MATERIALS, SUPPLIES, AND ALL WORK INSTALLED SHALL COMPLYWITH THE CODES, STANDARDS, RULES AND REGULATIONS OFRELEVANT STATUTORY AUTHORITIES INCLUDING, BUT NOTNECESSARILY LIMITED TO:· NATIONAL CONSTRUCTION CODE 2019· AS 3000:2018 ELECTRICAL INSTALLATIONS (WIRING RULES)· AS/NZS 2293 EMERGENCY LIGHTING AND EXIT SIGNS FOR BUILDINGS· AS/NZS 3008 ELECTRICAL INSTALLATIONS - SELECTION OF CABLES· AS 3017 ELECTRICAL INSTALLATIONS - TESTING GUIDELINES· AS 4072 FIRE PENETRATIONS· SUPPLY AUTHORITY REGULATIONSMAKE ALL APPLICATIONS AND PAY ALL FEES REQUIRED TO COMPLYWITH RELEVANT AUTHORITY REQUIREMENTS, INCLUDINGSELF-CERTIFICATION COSTS FOR ELECTRICAL INSPECTION.

1.3 DEFECTS LIABILITYGUARANTEE ALL WORK AND MATERIALS AS TO QUALITY,WORKMANSHIP AND AGAINST DEFECTS, FOR A PERIOD OF TWELVEMONTHS FROM THE DATE OF ISSUE OF THE 'CERTIFICATE OFPRACTICAL COMPLETION'. DURING THIS PERIOD, PROMPTLY REPLACEALL DEFECTIVE EQUIPMENT, FIXTURES AND MATERIALS AT NOADDITIONAL COST.

1.4 PROVISIONSPROVIDE THE FOLLOWING TO THE PROJECT MANAGER FOR REVIEWPRIOR TO COMMENCING INSTALLATION WORKS.· LIGHTING TECHNICAL DATA

1.5 WORKMANSHIPALL WORKMANSHIP AND MATERIALS SHALL BE TO THE SATISFACTIONOF THE PROJECT MANAGER. ALL MATERIALS SHALL BE NEW UNLESSOTHERWISE NOTED. ANY MATERIALS OR WORKMANSHIP, WHICH ARECONSIDERED INFERIOR OR NON-CONFORMING BY THE PROJECTMANAGER SHALL BE REPLACED AT THE CONTRACTOR'S COST.

1.6 LICENSED ELECTRICAL CONTRACTORALL WORKS SHALL BE UNDERTAKEN BY LICENSED ELECTRICALCONTRACTOR'S, QUALIFIED AND EXPERIENCED IN THE TYPE OF WORKREQUIRED FOR THIS PROJECT.

1.7 RELATED ELECTRICAL WORKSCO-ORDINATE AND CO-OPERATE WITH THE BUILDER AND OTHERTRADES (MECHANICAL, HYDRAULIC, ETC.) AS REQUIRED.

1.8 BACKGROUNDELECTRICAL WORKS REQUIRED FOR THE REFURBISHMENT OF THEHIGH COURT TOILET AMENITY UPGRADE INCLUDE:· ISOLATION, DISCONNECTION AND REMOVAL OF ALL ELECTRICAL

SERVICES NOTED ON THE DRAWINGS.· FINAL SUB-CIRCUITS TO ALL NOMINATED SERVICES.· NEW GENERAL LIGHTING AS DOCUMENTED ON THE DRAWINGS.· GENERAL POWER AS DOCUMENTED ON THE DRAWINGS.· TESTING AND COMMISSIONING· PROVISION OF AS BUILT DOCUMENTATIONA CONCURRENT PROJECT TO UPGRADE BUILDING EMERGENCY

LIGHTING IS BEING UNDERTAKEN. NEW UNSWITCHED ACTIVE ANDEMERGENCY LIGHTING TEST SWITCH SHALL BE PROVIDED BY THATPROJECT.

1.9 SCOPE OF WORKTHE SCOPE OF WORK INCLUDES THE DEMOLITION, SUPPLY, DELIVERY,INSTALLATION, TESTING AND SETTING TO WORK OF THE ELECTRICALLIGHTING AND POWER SYSTEMS AS SHOWN ON THE DRAWINGS ANDNOMINATED IN THE SPECIFICATION. SUPPLY ALL REQUIREDMATERIALS UNLESS OTHERWISE SPECIFIED. THE SCOPE OF WORKINCLUDES BUT IS NOT NECESSARILY LIMITED TO THE FOLLOWING:

1.9.1 LIGHTING· PROVIDE NEW LIGHTING AS SPECIFIED ON THE DRAWINGS. NEW

LIGHTING IS TO MAKE USE OF EXISTING CUTOUTS AND SUPPLIESWHERE AVAILABLE.

· ALTERNATE LIGHT FITTINGS WILL NOT BE ACCEPTED WITHOUTAPPROVAL FROM THE PROJECT MANAGER OR ELECTRICAL

ENGINEER. PROVIDE PRODUCT SHEETS FOR ALL ALTERNATIVEFIXTURES.

· ALL LIGHTING CIRCUITS MODIFIED AND NEW, SHALL BE RCDPROTECTED. ENSURE THAT THERE ARE A SUITABLE NUMBER OFLUMINAIRES ON EACH CIRCUIT SO AS TO AVOID FALSE RCDTRIPPING DUE TO EARTH LEAKAGE FROM THE BALLAST/LUMINAIRE.

· MAXIMUM EARTH LEAKAGE CURRENT PER BALLAST FOR ALL NEWLUMINAIRES SHALL BE LESS THAN 0.3 mA.

· COORDINATE FINAL SET-OUTS FOR LIGHT FIXTURES FROM ON-SITEDIMENSIONED SETOUTS. COORDINATE ALL LUMINAIREINSTALLATIONS WITH CEILING SETOUTS.

1.9.2 LIGHTING CONTROLS· PROVIDE MOTION DETECTION CONTROLS TO LIGHTING AS

NOMINATED ON DRAWINGS.· CONNECT TO EXISTING LIGHT SWITCH.· ALL LIGHT SWITCHES SHALL HAVE CIRCUIT REFERENCE MARKED ON

THE BACK OF THE FACEPLATES IN PERMANENT MARKER IF NOTALREADY DONE.

1.9.3 GENERAL POWER· SUPPLY AND INSTALL NEW POWER CONNECTIONS AS SHOWN ON

THE DRAWINGS.· RETICULATE POWER GENERALLY IN CEILING VOID, AND

TERMINATED WITHIN THE EXISTING DISTRIBUTION BOARD DB-1A.· PROVIDE CIRCUIT PROTECTION COMPLIANT WITH AS 3000. PROVIDE

RCD PROTECTION WHERE REQUIRED UNDER THE AUSTRALIANSTANDARDS.

· TEST AND CERTIFY THE COMPLETE SYSTEM

1.9.4 OUTLETS AND ACCESSORIES· SUPPLY, INSTALL AND CONNECT ALL NEW POWER OUTLETS AND

ACCESSORIES AS SHOWN.· ALL POWER OUTLETS SHALL HAVE CIRCUIT REFERENCE LABELS

WITH BLACK LETTERS ON WHITE BACKGROUND FIXED BY INTEGRALCIRCUIT DESIGNATION LABEL WINDOW ON SWITCH PLATE COVER.LABELS SHALL REFER TO THE SWITCHBOARD ORIGIN AND CIRCUITBREAKER NUMBER. NEW SWITCHBOARD LABELS SHALL SHOW IDAND ORIGIN ON INTERNAL ESCUTCHEON. ALSO LABEL GPO WITHPERMANENT MARKER OR OTHER MEANS WHICH SHALL BE VISIBLEWHEN COVER PLATE IS REMOVED.

· PROVIDE AND INSTALL CIRCUIT BREAKERS INCLUDING 30 mA RCD'sTO ALL GENERAL LIGHTING AND POWER CIRCUITS.

· COORDINATE OUTLETS AND CONNECTIONS TO DEDICATEDEQUIPMENT WITH THE INSTALLER OF THAT EQUIPMENT. (AUTODOOR)

1.9.5 EARTHING· THE INSTALLATION BY THE CONTRACTOR SHALL BE EARTHED.· EARTHING SHALL BE CARRIED OUT IN ACCORDANCE WITH THE

RELEVANT SUPPLY AUTHORITY REQUIREMENTS AND AS/NZS 3000AND AS/CA S009.

· REUSE THE EXISTING MEN POINT FOR THE BUILDING.

1.9.6 CABLE SELECTION· SUPPLY, INSTALL AND CONNECT ALL NEW POWER AND LIGHTING

CABLING NECESSARY TO COMPLETE THE INSTALLATION.· ALL POWER AND LIGHTING CABLES SHALL BE THERMOPLASTIC

INSULATED (T.P.I) AND SHEATHED (T.P.S) 0.6/1.0 kV GRADE ASAPPLICABLE WITH AS 5000.1. INSULATION SHALL BE V75 GRADEUNLESS OTHERWISE NOTED.

· LIGHTING SUB-CIRCUITS: 2.5 mm² MIN.· GENERAL PURPOSE POWER CIRCUITS: MIN 2.5 mm².· CONTROL CIRCUITS ETC: MIN 2.5 mm².· FLEXIBLE CORDS: MIN 30/0.25 mm²· SEGREGATE LV POWER CABLING AND COMMUNICATIONS/CONTROL

CABLING TO AS 3000 AND AS/CA S009. PARTICULAR ATTENTIONNEEDS TO BE PAID TO RETICULATION OF CABLING WITHIN SERVICESCOLUMNS AND WORKSTATION SCREENS, TO ENSURE THATSEGREGATION AND SEPARATION BETWEEN POWER ANDCOMMUNICATIONS CABLING IS MAINTAINED.

· ALL CABLING SHALL BE CONCEALED IN CEILING SPACES OR WALLSUNLESS INDICATED OR APPROVED OTHERWISE.

· ALL CABLING INDICATED OR APPROVED TO NOT BE IN A CONCEALEDCEILING SPACE ARE TO BE ENCASED IN CONDUIT OR DUCT ANDSECURELY MOUNTED IN FLAT FORMATION AGAINST A WALL OR SLABIN ACCORDANCE WITH AS 3008.

1.9.7 TESTING AND COMMISSIONING· CARRY OUT TESTING, OPERATING AND ADJUSTING THE SYSTEM

AND EQUIPMENT, AND FOR FULLY INSTRUCTING THE PROJECTMANAGER OR THEIR REPRESENTATIVE IN THE OPERATION OF THESYSTEM AND EQUIPMENT. PROVIDE FULL OPERATOR'S MANUAL.

· DEMONSTRATE TO THE PROJECT MANAGER AND NOMINATEDREPRESENTATIVES THE FULL OPERATION OF THE LIGHTINGCONTROL SYSTEM (INCLUDING ALL PRE-SETS AND CONTROLSOUTLINED WITHIN THIS DOCUMENT AND ALL MOTION SENSOR /TIMER CONTROLS PRESCRIBED) IN ACCORDANCE WITH THEPERFORMANCE REQUIREMENTS OUTLINED ON THE DRAWINGS.

· SUBMIT TEST REPORTS. PROVIDE THE PROJECT MANAGER WITHALL TEST RESULTS, BOUND, FOR REVIEW. THE CERTIFICATE OFPRACTICAL COMPLETION WILL ONLY BE SIGNED AFTER THECOMPLETE TEST REPORTS HAVE BEEN REVIEWED. INCLUDE A HARDAND SOFT COPY OF THE FULL TEST REPORTS IN THE OPERATIONAND MAINTENANCE MANUALS.

· CARRY OUT TESTING IN ACCORDANCE WITH AS 3000 CLAUSE 8.3 &8.33 MANDATORY TESTS 8.3.10. OPERATION OF RCD'S.

1.9.8 AS-BUILT HARD COPY DRAWINGS AND MAINTENANCE MANUALS· PROVIDE A FULL SET AND A 'DWG' (AUTOCAD LATEST VERSION) SET

ON DISK OF AS-BUILT DRAWINGS, TO THE SATISFACTION OF THEPROJECT MANAGER, WITHIN 7 DAYS OF PRACTICAL COMPLETION.THE AS- BUILT DRAWINGS SHALL COMPREHENSIVELY REFLECTDETAILS OF ALL INSTALLED SYSTEMS AND COMPONENTS, ASDETAILED IN THE SCOPE OF WORK.

· PROVIDE TWO SETS OF OPERATION AND MAINTENANCE MANUALS,THE AIM OF THESE BEING TO PROVIDE A DETAILED UNDERSTANDINGOF THE ITEMS OF EQUIPMENT AND ITS OPERATION, AN AID FORTRAINING OF OPERATORS, A REFERENCE FOR FAULT DIAGNOSISAND A FRAMEWORK FOR PREVENTIVE AND BREAKDOWNMAINTENANCE. THE MANUALS SHALL INCLUDE, AS A MINIMUM:· NAME, ADDRESS, TELEPHONE AND FACSIMILE NUMBERS OF

THE MANUFACTURER AND SUPPLIER OF ITEMS OF EQUIPMENTINSTALLED, TOGETHER WITH CATALOGUE LIST NUMBERS.ITEMS SHALL INCLUDE, BUT ARE NOT LIMITED TO ALL LIGHTFIXTURES, SWITCHES AND GPOS.

· INCLUDE SUCH DETAILS FOR ALL CONSULTANTS ANDCONTRACTORS INVOLVED IN THE DESIGN AND CONSTRUCTIONPHASES

· TECHNICAL DESCRIPTION AND MODES OF OPERATION OF THESYSTEMS INSTALLED.

· PRODUCT LITERATURE FOR THE SYSTEMS INSTALLED ANDCONTACT DETAILS FOR SUPPLIERS AND MANUFACTURERS' OFTHESE SYSTEMS.

· CONTROL AND SWITCHING SEQUENCES AND FLOW DIAGRAMSFOR SYSTEMS INSTALLED, INCLUDING SAFETY FEATURES.ALSO PROCEDURES FOR OPERATING AND ADJUSTINGCONTROL SYSTEMS.

· MANUFACTURERS' OPERATIONAL AND SAFETY LITERATURE, ASAPPROPRIATE.

· EMERGENCY MAINTENANCE PROCEDURES, INCLUDINGTELEPHONE NUMBERS FOR EMERGENCY SERVICES, ANDAFTER HOURS CONTACTS FOR SUPPLIERS AND CONTRACTORSAND PROCEDURES FOR FAULT FINDING.

· STATUTORY CERTIFICATES OF COMPLIANCE FOR ALLELECTRICAL AND COMMUNICATIONS WORK, COPIES OFMANUFACTURERS' WARRANTIES, CERTIFICATES FROMAUTHORITIES AND UTILITIES, PRODUCT CERTIFICATION,COPIES OF TEST CERTIFICATES, ETC.

· AS-BUILT DRAWINGS, SHOP DRAWINGS, SYSTEM SCHEMATICSETC.

· COMMISSIONING RECORDS.

EXISTING LAYOUT

PROPOSED LAYOUT

SCALE: 1:50

SCALE: 1:50

0 1500mm500 1000

SCALE 1:50 AT ORIGINAL SIZE

SA

250

x250

SA 250x250

SA

150

x250

SA 200x200

140L/s

THE REMAINING PART OF THE

EXISTING DUCTWORK WILL BE

CAPPED OFF.

75L/s

EXTEND EXISTING DUCTWORK AS

SHOWN TO PROVIDE FACE GRILLE

150mmx150mm FOR SUPPLY AIR OF

75L/S. CLEAN DUCTWORK AND

REBALANCE TO ACHIEVE DESIGN

AIRFLOWS

80L/s

REPLACE EXISTING TOILET EXHAUST

DUCTWORK WITH NEW DUCTWORK

WITH SIZES AS SHOWN IN DRAWING.

ADD A NEW EXHAUST FACE GRILLE

150mmX150mm TO SERVE THE NEW

PARENT ROOM AS SHOWN.

REBALANCE NEW DUCTWORK TO SUIT

EXTEND THE NEW DUCTWORK TO

JOIN THE EXISTING MAIN TOILET

EXHAUST DUCT ROUTING.

OPEN THE VCD TO FULL AT THE

RISER.

TE

200

x200

TE

250

x250

40L/s

35L/s

RECONNECT EXISTING EXHAUST

GRILLES FROM FEMALE TOILET TO

NEW EXHAUST DUCTWORK AS SHOWN

EXISTING SUPPLY AIR DUCTWORK

TO BE DEMOLISHED FOR NEW

SLIDING DOOR

SA

250

x250

SA 250x250SA 200x200

EXISITING SUPPLY AIR DUCTWORK

BRANCHED FROM MAIN DUCT

SERVING TOILETS

TE

250

x150

TE

100

x100

DEMOLISH EXISTING

TOILET EXHAUST

DUCTWORK AS SHOWN

90L/s

A1

PROJECT

DRAWING TITLE

NOTES

DESIGNED UNDER QUALITY SYSTEM CERTIFIED AS COMPLYING

WITH ISO 9001 BY AN ACCREDITED CERTIFICATION BODY

© Copyright. This Document and Design remains the copyright of Steensen Varming (Australia) Pty Ltdand cannot be reproduced in any way without prior consent. The contractor shall verify all dimensions and levels on site as this is not a workshop drawing. The contractor shall refer any discrepancies to the engineer before proceeding with the work.

This drawing shall be read in conjunction with other contract documents, drawings and project specifications. This file has been checked by an antivirus program with the latest update. However new viruses are discovered everyday we recommend that this file is rescanned upon receipt.

MECHANICAL SERVICES

STATUS

STEENSEN VARMING

CopenhagenLondonSydneyHong KongNew York

8, 9 Castlereagh St.Sydney, NSW, 2000, AustraliaABN 50 001 189 037t : +61 / 02 9967 2200e : [email protected]

0 2.5m 5m

SCALE

REVISIONDRAWING No.PROJECT No.

NORTHPOINTAPPROVED

DRAWN DESIGNED CHECKEDSUITABILITY

C:\U

se

rs\a

bu

.he

na.S

ubh

an

\Do

cum

en

ts\2

07

02

8-S

V-X

X-X

X-M

3-M

EP

-00

01_

ab

u.h

ena

.Sub

ha

n.r

vt

1 : 50

2

HIGH COURT OF AUSTRALIAAMENITIES UPGRADE

GROUND LEVEL - FLOOR PLAN ANDDEMOLITION PLAN

FOR TENDER

207028-SV-XX-00-DR-M-2000

DM

IR FS DM

GROUND LEVEL - FLOOR PLAN1

GROUND LEVEL - DEMOLITION2

AMENDMENTS

REV DESCRIPTION DATE

1 FOR TENDER 02.07.2021

2 FOR TENDER 10.08.2021

LEVEL B1

LEVEL B2

GROUND LEVEL

LEVEL 2

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 6

LEVEL 7

LEVEL 8

LEVEL 9

LEVEL 10

ROOF LEVEL

OUTSIDE AIR 100L/s

STAFF LOBBY 400L/s

STAFF ENTRY 100L/s

R/A 400L/s

MARSHALL STORE 200L/s

SECURITY 725L/s

POLICE HOLDINGS 200L/s

PRACTITIONERS DINING 250L/s ZONE 45

LEVEL B1

LEVEL B2

GROUND LEVEL

LEVEL 2

LEVEL 3

LEVEL 4

LEVEL 5

LEVEL 6

LEVEL 7

LEVEL 8

LEVEL 9

LEVEL 10

ROOF LEVEL

STAIR PRESSURISATION 4500L/s

OUTSIDE AIR6180L/s MIN

OUTSIDE AIR9580L/s MAX2660L/s MIN

OUTSIDE AIR3480L/s MAX1280L/s MIN

OUTSIDE AIR12522L/s MAX2750L/s MIN

PABX265L/s

AHU3AHU2AHU1 AHU4

OUTSIDE AIR635L/s MIN7631L/s MAX

O/A100L/s

O/A207L/s

O/A120L/s

O/A330L/s

O/A290L/s

O/A793L/s

LOBBY310L/s

REGISTRARS2090L/s

RETURN AIR2300L/s

LOBBY410L/s

OFFICE MONITOR ROOM 2120L/s

RETURN AIR2323L/s

LOBBY250L/s

REGISTRARS1860L/s

RETURN AIR1990L/s

LOBBY160L/s

ATTORNEY GENERAL 1600L/s

RETURN AIR1430L/s

LOBBY160L/s

LIBRARIAN1400L/s

RETURN AIR1270L/s

CORRIDOR LOBBY195L/s

CONFERENCE??L/sTOTAL

RETURN AIR1166L/s

O/A STAIR4500L/s

STAIR PRESS4500L/s

AHU18

AHU17

AHU16

AHU15

AHU14

AHU13

PRACTICE COURT1825L/s

LOBBY90L/s

JUSTICE RECPT. PERIM.320L/s

REST ROOM40L/s

TOILET??L/s

COMMON ROOM PERIMETER812L/s

COMMON ROOM INTERIOR1150L/s

KITCHEN400L/s

??90L/s

TOILET155L/s

OUTSIDE AIR1430L/s

RETURN AIR 1000 L/s

DINING ROOM1260 L/s

DINING ROOM2015 L/s

DUPLICATING 1205 L/sZONE 4.2

COMPACTUS 1060 L/sZONE 4.1

ATT 5.8

RETURN AIR 1200 L/s

RETURN AIR 2220 L/s

RETURN AIR 5155 L/s

RETURN AIR 625 L/s

RETURN AIR 1400 L/s

RETURN AIR 2000 L/s

RETURN AIR 2130 L/s

TOILET EXHAUST 50 L/s

JUSTICES RETIRING550 L/s

TOILET EXHAUST 270 L/s

WITNESS RETIRING625 L/s

PUBLIC HALL5355 L/s

PRACTITIONERS INTERNAL480 L/s

PRACTITIONERS PERIMETER1230 L/s

BAR LIBRARY PERIMETER1170 L/s

TOILET EXHAUST 25 L/s

BAR LIBRARY INTERNAL 980 L/s

BAR LIBRARY INTERNAL1000 L/s

BAR LIBRARY PERIMETER1125 L/s

CHIEF JUSTICE INTERNAL296 L/s

CHIEF JUSTICE PERIMETER380 L/s

RETURN AIR1260 L/s

TOILET EXHAUST 75 L/s

TOILET EXHAUST 465 L/s

TEA ROOM795 L/s

BUILDING SERVICES660 L/s

DINING AREA620 L/s

DRIVERS LOUNGE85 L/s

CORE 1A CORRIDOR160 L/s

PRESS ROOM515 L/s TOILET

EXHAUST515 L/s

PUBLIC HALL1010 L/s

JUSTICE RETIRING290 L/s

JURY RETIRING600 L/s

TOILET EXHAUST75 L/s

RETURN AIR2330 L/s

JUSTICE RETIRING150 L/sTOILET

EXHAUST75 L/s

TOILET EXHAUST75 L/s

STAIR PRESS4500 L/s

OUTSIDE AIR4500 L/s

COURT No.32330 L/s

COMPACTUS945 L/s

RELIEF AIR3210 L/s MAX1010 L/s MIN

RELIEF AIR12522 L/s MAX2750 L/s MIN

RELIEF AIR?? L/s MAX?? L/s MIN

RELIEF AIR24732 L/s MAX

RETURN AIR7810 L/s MIN9000 L/s

OUTSIDE AIR6180L/s MIN

OUTSIDE AIR6180L/s MIN

BAR1800L/sPUBLIC

1800L/s

JUSTICE1800L/s

COURT3600 L/s

BALCONY FOYER230 L/s

COURT No.1

COURT No.1 RELIEF600 L/s

COURT No.1 RELIEF600 L/s

AHU19

PARENT ROOM EXHAUST 80L/S

(N) TEF -01A 1725L/S

(N) TEF -01B 1725L/S

REBALANCE FAN CONTROLS AND FAN SPEED TO

ACCOMODATE THE NEW 80L/S EXHAUST AIRFLOW

FROM THE PARENTS ROOM

SCALE

PROJECT

DRAWING TITLE

NOTES

DESIGNED UNDER QUALITY SYSTEM CERTIFIED AS COMPLYING

WITH ISO 9001 BY AN ACCREDITED CERTIFICATION BODY

© Copyright. This Document and Design remains the copyright of Steensen Varming (Australia) Pty Ltdand cannot be reproduced in any way without prior consent. The contractor shall verify all dimensions and levels on site as this is not a workshop drawing. The contractor shall refer any discrepancies to the engineer before proceeding with the work.This drawing shall be read in conjunction with other contract documents, drawings and project specifications. This file has been checked by an antivirus program with the latest update. However new viruses are discovered everyday we recommend that this file is rescanned upon receipt.

REVISIONDRAWING No.PROJECT No.

NORTHPOINT

MECHANICAL SERVICES

STATUS

APPROVED

DRAWN DESIGNED CHECKED

A0

STEENSEN VARMINGSTEENSEN VARMINGSTEENSEN VARMINGSTEENSEN VARMING

CopenhagenLondonSydneyHong KongNew York

8, 9 Castlereagh St.Sydney, NSW, 2000, AustraliaABN 50 001 189 037t : +61 / 02 9967 2200e : [email protected]

SUITABILITY

0

1 : 1

1

C:\U

sers

\arie

l.liz

ca

no

\Do

cu

men

ts\2

070

28-S

V-X

X-X

X-M

3-M

EP

-000

1_A

riel.liz

cano

T7

N2W

.rvt

207028-SV-XX-DR-M-8000

HIGH COURT OF AUSTRALIAAMENITIES UPGRADE

AIR SCHEMATIC

FOR TENDER

DM

IR FS DM

AMENDMENTS

REV DESCRIPTION DATE

1 FOR TENDER 02.07.2021

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

MECHANICAL ENGINEERING STEENSEN VARMING

High Court of Australia – Amenities Upgrade Performance Speci�cation

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 2 / 11

steensenvarming.com 207028sp 001

Document Revision and Status

Date Rev Issue Notes Checked Approved

02-07-2021 1 For Tender DM FS

Disclaimers and Caveats: Copyright © 2021, by Steensen Varming Pty Ltd. All rights reserved. No part of this report may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of Steensen Varming Pty Ltd. This document is con�dential and contains privileged information regarding existing and proposed services for the Building. The information contained in the documents is not to be given to or discussed with anyone other than those persons who are privileged to view the information. Privacy protection control systems designed to ensure the highest security standards and con�dentiality are to be implemented. You should only re-transmit, distribute or commercialise the material if you are authorised to do so.

Canberra July 2nd, 2021 Ref. No. 207028sp001 Faraan Shareef Senior Mechanical Engineer [email protected] (02) 9967 2200

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 3 / 11 steensenvarming.com 207028ms003 Rev 02

Table of Contents

1.0 General 4

1.1 The project 4

1.1.1 Description of the project 4

1.1.2 Description of the existing mechanical system 4

1.1.3 Redundant Equipment 7

2.0 Project Parties 8

2.1 Contractor 8

2.2 Mechanical Services Contractor 8

2.3 Principal 8

3.0 Mechanical Services Works 9

3.1 Scope of Works 9

3.2 Basis of the Mechanical Services Performance Speci�cation 9

3.3 Scope of Mechanical Services 9

3.4 Other Trades 10

3.4.1 Building Trade 10

Standards and Authorities 10

3.5 Documentation 11 3.5.1 General Requirements 11 3.6 Equipment 11 3.7 Grilles and DiFusers 11

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 4 / 11 steensenvarming.com 207028ms003 Rev 02

1.0 General

1.1 The project

The project is the selected amenity upgrade of the High Court of Australia as part of the 2020/21 Upgrade.

1.1.1 Description of the project

This project consist of the upgrade of the following area: Ground Floor Parent Amenities Room – There is a requirement to upgrade the existing PWD Room and the Parents Room because the overall dimensions of the PWD are not compliant and the access to the parents room is via the female toilets which will now be changed to sliding door.

1.1.2 Description of the existing mechanical system

Ground Floor Parent Amenity The existing mechanical system for ground Ioor parent amenity comprises of the below exhaust ductwork reticulation. The room is used as a PWD Room, and the exhaust discharges through a toilet exhaust fan located on the roof. A centralized supply air fan provides the makeup air to the room.

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 5 / 11 steensenvarming.com 207028ms003 Rev 02

However, since the new proposed PWD room has modi�ed amenities and the sliding door is full height, there will be modi�cations to the ventilation requirements and the duct routing. The existing exhaust fan which is serving the toilet exhausts has a capacity of 1725l/s is of good condition and capacity as it was installed in the recent past, however contractor will be required to carry out the investigation to be able to rebalance the exhaust grilles to suit.

Image 2 : Ground Floor Parent Toilet Supply & Exhaust Ducts

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 6 / 11 steensenvarming.com 207028ms003 Rev 02

Image 3 : Air Schematic

Image 4 : Centralised Exhaust Fans

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 7 / 11 steensenvarming.com 207028ms003 Rev 02

Interruption of Existing Services Where the work under the contract aFects the continuity of existing services the Contractor shall arrange to have the work carried out at the least inconvenient time to the Principal. The work shall be organised to minimise the duration of inconvenience. This will mean out of hours work will need to be undertaken for elements of the Work or unless arranged otherwise with the Principal.

1.1.3 Redundant Equipment

All equipment and services made redundant through this project and required to be removed from its existing place of installation shall be removed from the site by the Contractor and shall be disposed of by the Contractor. All eFort shall be made to recycle redundant equipment associated with this Contract. The Contractor shall provide a waste management plan together with records of relevant disposal and recycling activities. All redundant mechanical services shall be stripped out to the extent indicated on the drawings. Redundant mechanical electrical services and control services shall be stripped back to source and associated ways in MCCs etc. shall be labelled as ‘spare’.

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 8 / 11 steensenvarming.com 207028ms003 Rev 02

2.0 Project Parties

2.1 Contractor

The Contractor is referred here as the company engaged to provide the complete works including all materials, designs and provisions for any temporary works. Where works are described as being provided by the Contractor in this speci�cation they are expected to be included in the tender price for the Project whether or not they are included in other works descriptions for other sections of the Project. All works described in this speci�cation as being provided by the Contractor are to include all materials and designs where required for the completion of the works.

2.2 Mechanical Services Contractor

The mechanical services contractor is referred to here when speci�c items are known to be applicable to the mechanical services associated with the Project. The reference to works being undertaken by a mechanical services contractor does not obligate the contractor to engage a speci�c company associated with mechanical services to undertake the works. All works described as being by a mechanical services contractor are part of the overall works for the Project that the Contractor is contracted to provide.

2.3 Principal

The Principal for the Project is High Court of Australia. The Principal’s Representative is Eric Martin Architects

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 9 / 11 steensenvarming.com 207028ms003 Rev 02

3.0 Mechanical Services Works

3.1 Scope of Works

This scope of works is the complete tender package for works described herein. General The divisions of the scopes for various trades are indicative only in this speci�cation and does oblige the Contractor to divide the works as described. The divisions are based on standard practice for ease of division of the works for the Contractor.

3.2 Basis of the Mechanical Services Performance Speci�cation

The mechanical services contractor shall design, supply and construct all the mechanical services required for the Project described herein. The items included in this speci�cation are indicative of the minimum standards and requirements for the Project and do not limit the extent of works for all items required to complete the Project. The mechanical services contractor is to allow all components and associated works as required to complete the works whether stated or not in this speci�cation or shown on the drawings.

3.3 Scope of Mechanical Services

The scope of works for this Project for the mechanical services includes but is not limited to the following: Ground Floor Parent Amenity

Detailed site inspection of the existing mechanical services including areas associated with this project, review of ”AS” built drawings and Operating and Maintenance Manuals all located to enable to determine the extent of works.

Existing supply ductwork must be demolished because of the new full height sliding door.

Extend the existing supply air ductwork to the room as shown in the attached drawings M-2000.

Supply and install a supply face grille, 150x150 to supply the required outdoor airIow, 75 L/s to the room.

After removing the existing supply air ductwork, remaining piece of the ductwork needs to be capped which is serving the adjacent space as shown in M-2000.

The exhaust ductworks must be replaced with a new size of the duct works requested and shown in the attached drawings M-2000.

A 150x150 exhaust grille is required to be located on the exhaust duct work inside the room to exhaust of 80 L/s air Iow.

Extend the new exhaust ductwork to connect the main toilet exhaust ductwork.

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 10 / 11 steensenvarming.com 207028ms003 Rev 02

Connect the existing exhaust grilles from female toilets to new exhaust duct as shown in M-2000.

Open the VCD located at the riser fully open. Testing and Commissioning of the completed grilles within the toilet space. All air Iows are to be balanced to within 5% of the �nal design air Iows for the

systems. The existing exhaust fan capacity to be recon�rmed on site which is serving the

toilets from L1 to L9 is of good condition and capacity as it was installed in the recent past, contractor will be able to rebalance the exhaust grilles to suit.

Labelling of all grilles with trifoliate labels.

3.4 Other Trades

Services provided by other trades are expected to be as the following sections. Coordination between all trades is expected to be included within the Contractor’s scope of works.

3.4.1 Building Trade

Ceiling penetrations for all grilles, and diFusers

Standards and Authorities

All mechanical services shall be in accordance with all related statutory and other authorities including but not limited to the following:

National Construction Code Series (BCA) – 2019 AS3000 – Wiring Rules The Property Council of Australia. The Standards Association of Australia, AS1668.1:2015 AS1668.2:2012 and AS3666.

Local Authorities such as:

ACTEW Corporation ACT Fire Brigade. ACT Environment, Planning and Sustainable Development Directorate . ACT WorkCover. ACTPLA – Planning Authority ACT NCA – National Capital Authority

Any other Authority having jurisdiction over the installation to ensure that the machinery and installation will comply with the Rules and Regulations. On completion of the installation and prior to �nal payment being made the Contractor is to arrange for each Authority having jurisdiction to inspect and check the contract works and where required by the Principal to obtain certi�cates from such Authority to the eFect that the equipment, machinery and installation complies

When I’m working on a problem, I never think about beauty. I think only how to solve the problem. But when I have �nished, if the solution is not beautiful, I know it is wrong. Richard Buckminster Fuller

Mechanical Engineering Lighting Design Sustainable Design Electrical Engineering

Copenhagen London Sydney Hong Kong New York

GF 1, 17 Moore Street Canberra, ACT, 2601, Australia ABN 50 001 189 037 t : +61 / 02 6230 0502 e : [email protected]

STEENSEN VARMING

Page 11 / 11 steensenvarming.com 207028ms003 Rev 02

with that Authority's requirements. These certi�cates are to be forwarded to the Principal. The design and installation of the services must comply with the seismic constraint

requirements in accordance with the AS1170.4 SAA Earthquake Code.

3.5 Documentation

3.5.1 General Requirements

The Contractor is required to provide from a suitable quali�ed Mechanical Services Contractor the following documentation:

Shop drawings of the proposed works for review by the Principal & Engineer Equipment selection manufactures data for grilles System pressure calculations of all ducted existing AHU SA and RA fans Ductwork design to AS4254 Pt1 & 2. 2012 As-built documentation of the mechanical services and other works completed as

part of the Project that relate to the mechanical services Operation and maintenance manuals of the works (if any) including the following: Equipment and material schedules Supplier schedules As-built documentation Commissioning results Installation certi�cates of the mechanical services 12months Services or same as head contract.

3.6 Equipment

3.7 Grilles and Di=users

For this project the exhaust & supply air grilles shall be retained by the MSC and shall be inspected and checked to be equal to design spec. All grilles to have removable cores and

All grilles to be painted as per the architectural requirements.