www.cbsscientific.com phone: (858) 755-4959 Toll Free: (800) 243-4959 BLOTTING BLOTTING red side blotting paper gel foam pad black side membrane COMPATIBLE PRODUCTS INCLUDE: Mini-Verticals These blotters fit gels from our MGV-102 and MGV-302 single vertical Mini-Gel Systems. Quadra Mini-Vertical, 4-place, Cat. #’s QNX-700, QNC-700 Runs 4 10cm x 10cm SDS- PAGE gels at a time. This combo unit can also be used for blotting. Dual Cool Mini-Vertical, 2-place, Cat. # DCX-700 Runs 2 10cm x 10cm SDS- PAGE gels at a time. This combo unit can also be used for blotting. CASSETTE FEATURES AND TRANSFER ASSEMBLY Hinged cassette with double latches assures equal contact on blotting stack and allows easy loading and removal of blot The cassette assembly consists of two hinged, molded polycarbonate panels and one sponge pad between which the gel, membrane and blotting paper are placed. See diagram below. Dual Mini-Verticals These blotters fit gels from our MGV-202 and MGV-402 Dual Mini-Vertical Systems. ORDERING INFORMATION CAT. # DESCRIPTION MINI-BLOTTING SYSTEMS - FOR UP TO 10CM X 10CM BLOTS EBU-204 Mini-Blotting System, 4 place, with cooling base and platinum electrode panels, fits gel cassette/glass plate dimensions 10cm(w) x 10cm (h) EBU-204P Mini-Blotting System, 4 place, with cooling base and plate electrodes, fits gel cassette/glass plate dimensions 10cm(w) x 10cm (h) EBX-700 Mini-Blotting System, 4 place, with freezer blocks, fits gel cassette/glass plate dimensions 10cm(w) x 10cm (h) Accessories and Replacement parts for EBU-204 or EBX-700 EBX-BC-700 Additional Blotting Cassette EBX-SP-700 Additional Sponge Pads, package of 4 EPX-250 X High Current Power Supply, CE, 2-250V, 10-2500mA EPS-300 X Power Supply, CE, 1-300V, 1-500mA Recommended Power Supplies See page 55 for complete description. EPS-300 X Power Supply Universal input with timer. Input: 100-240 VAC, 50-60 Hz. Output voltage 1-300V, output current: 1-500mA in 1mA steps EPX-250 X High Current Power Supply Universal input with timer. Input: 100-240 VAC, 50-60 Hz. Output voltage 2-250V, output current: 10-2500mA in 1mA steps Temperature controlled Tank Blotting Systems fit four 10cm x 10cm mini-gels FEATURES Tank Blotting System includes a cooling grid in base for temperature control during runs. Capability of transferring 4 gels simultaneously under identical temperature controlled buffer conditions Transfer cassette assembly consists of hinged, molded polycarbonate panels and sponge pads. Stirring bar can be placed beneath the cassettes to allow buffer circulation, even temperature distribution and heat exchange during electrophoresis. Fits four gels with precast cassette or glass plate dimensions of 10cm x 10cm. Plate Electrode Option (EBU-204P): The anode is made from a platinum- plated Titanium sheet; the cathode is made of durable 351 stainless steel. Plate electrodes provide a more dense electrical field resulting in faster, more efficient transfers. This option can speed up transfer of proteins over the whole spectrum of molecular weights. A high current power supply (such as the EPX-250X) must be used with plate electrodes. Mini-Blotting System, 4-place EBU-204, EBU-204P Complete System: • Blotting chamber with room for spin bar beneath cassettes and internal cooling base for temperature controlled runs • 2 platinum electrode panels (EBU-204) or plate electrode option (EBU-204P) • 4 transfer cassettes with 4 sponge pads • 4 additional sponge pads • Safety cover with power leads • Tubing adapters SPECIFICATIONS Cat. # Overall Dimensions L x W x H (cm) Recommended Buffer Volume (mls) Maximum # of Gels Method of Temperature Control Fits Gel Cassette/ Glass Plate Size W x H (cm) Compatible C.B.S. Scientific Vertical Systems (catalog number) EBX-700 14 x 13 x 16 1200 (no freezer blocks) 850 (2 freezer blocks) 4 freezer blocks 10 x 10 10 x 8 DCX-700, QNX-700, QNC-700, MGV-302, MGV-402, MGV-102, MGV-202 EBU-204 EBU-204P 14 x 13 x 16 1200 4 cooling base 10 x 10 10 x 8 DCX-700, QNX-700, QNC-700, MGV-302, MGV-402, MGV-102, MGV-202 APPLICATIONS Western Blotting Southern Blotting Northern Blotting Mini-Blotting System, 4-place EBX-700 Complete System: • Molded blotting chamber with spin bar corral • 4 freezer blocks • 2 platinum electrode panels • 4 transfer cassettes with 4 sponge pads • 4 additional sponge pads • Safety cover with power leads Mini-Blotting Systems FEATURES Temperature control is achieved through the use of freezer blocks on both ends of the reservoir, eliminating the need for an external cooling apparatus. Capability of transferring 4 gels simultaneously under identical temperature controlled buffer conditions Transfer cassette assembly consists of hinged, molded polycarbonate panels and sponge pads. Color-coded components for correct polarity orientation. Stirring bar can be placed beneath the cassettes to allow buffer circulation, even temperature distribution and heat exchange during electrophoresis. Fits four gels with precast cassette or glass plate dimensions of 10cm x 10cm. EBU-204 EBX-700 EBU-204P

Temperature controlled Tank Blotting Systems fit four 10cm x … · 2018-02-19 · Mini-BLottinG sYsteMs - For UpCat. # to 10CM X 10CM BLots EBU-204 Mini-Blotting system, 4 place,

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Temperature controlled Tank Blotting Systems fit four 10cm x … · 2018-02-19 · Mini-BLottinG sYsteMs - For UpCat. # to 10CM X 10CM BLots EBU-204 Mini-Blotting system, 4 place,

w w w. c b s s c i e n t i f i c . c o m p h o n e : ( 8 5 8 ) 7 5 5 - 4 9 5 9 To l l F r e e : ( 8 0 0 ) 2 4 3 - 4 9 5 934 35

BLO

TT

ING

BLO

TT

ING

red side

blotting paper

gel

foam pad

black side

membrane

Compatible produCts inClude:

Mini-VerticalsThese blotters fit gels from our MGV-102 and MGV-302 single vertical Mini-Gel Systems.

Quadra Mini-Vertical,4-place, Cat. #’s QNX-700,

QNC-700Runs 4 10cm x 10cm SDS-PAGE gels at a time. This combo unit can also be used for blotting.

Dual Cool Mini-Vertical,2-place, Cat. # DCX-700Runs 2 10cm x 10cm SDS-PAGE gels at a time. This combo unit can also be used for blotting.

Cassette Features and transFer assembly

• Hinged cassette with double latches assures equal contact on blotting stack and allows easy loading and removal of blot

• The cassette assembly consists of two hinged, molded polycarbonate panels and one sponge pad between which the gel, membrane and blotting paper are placed. See diagram below.

Dual Mini-VerticalsThese blotters fit gels from our MGV-202 and MGV-402 Dual Mini-Vertical Systems.

ORDERING INFORMATION Cat. # DesCription

Mini-BLottinG sYsteMs - For Up to 10CM X 10CM BLotsEBU-204 Mini-Blotting system, 4 place, with cooling base and platinum electrode panels, fits gel cassette/glass plate dimensions 10cm(w) x 10cm (h)EBU-204P Mini-Blotting system, 4 place, with cooling base and plate electrodes, fits gel cassette/glass plate dimensions 10cm(w) x 10cm (h)EBX-700 Mini-Blotting system, 4 place, with freezer blocks, fits gel cassette/glass plate dimensions 10cm(w) x 10cm (h)accessories and replacement parts for eBU-204 or eBX-700EBX-BC-700 Additional Blotting CassetteEBX-SP-700 Additional Sponge Pads, package of 4EPX-250 X High Current power supply, Ce, 2-250V, 10-2500mAEPS-300 X power supply, Ce, 1-300V, 1-500mA

recommended power suppliesSee page 55 for complete description. eps-300 X power supply

Universal input with timer. Input: 100-240 VAC, 50-60 Hz. Output voltage 1-300V, output current: 1-500mA in 1mA steps

epX-250 X High Current power supply Universal input with timer. Input: 100-240 VAC, 50-60 Hz. Output voltage 2-250V, output current: 10-2500mA in 1mA steps

Temperature controlled Tank Blotting Systems fit four 10cm x 10cm mini-gels

FeatUres• Tank Blotting System includes a cooling grid in base for temperature control during runs.• Capability of transferring 4 gels simultaneously under identical temperature controlled buffer conditions• Transfer cassette assembly consists of hinged, molded polycarbonate panels and sponge pads.• Stirring bar can be placed beneath the cassettes to allow buffer

circulation, even temperature distribution and heat exchange during electrophoresis.

• Fits four gels with precast cassette or glass plate dimensions of 10cm x 10cm.

• Plate Electrode Option (EBU-204P): The anode is made from a platinum-plated Titanium sheet; the cathode is made of durable 351 stainless steel. Plate electrodes provide a more dense electrical field resulting in faster, more efficient transfers. This option can speed up transfer of proteins over the whole spectrum of molecular weights. A high current power supply (such as the EPX-250X) must be used with plate electrodes.

Mini-Blotting system, 4-placeEBU-204, EBU-204PComplete System:• Blotting chamber with room for spin bar beneath cassettes and

internal cooling base for temperature controlled runs• 2 platinum electrode panels (EBU-204) or plate electrode option

(EBU-204P)• 4 transfer cassettes with 4 sponge pads• 4 additional sponge pads• Safety cover with power leads• Tubing adapters

SPECIFICATIONS

Cat. #Overall

DimensionsL x W x H (cm)

Recommended Buffer Volume

(mls)

Maximum # of Gels

Method of Temperature

Control

Fits Gel Cassette/Glass Plate Size

W x H (cm)

Compatible C.B.S. Scientific Vertical Systems(catalog number)

eBX-700 14 x 13 x 16 1200 (no freezer blocks)

850 (2 freezer blocks)

4 freezer blocks 10 x 1010 x 8

DCX-700, QNX-700, QNC-700, MGV-302, MGV-402, MGV-102, MGV-202

eBU-204eBU-204p

14 x 13 x 16 1200 4 cooling base 10 x 1010 x 8

DCX-700, QNX-700, QNC-700, MGV-302, MGV-402, MGV-102, MGV-202

appLiCations• Western Blotting• Southern Blotting• Northern Blotting

Mini-Blotting system, 4-placeEBX-700Complete System:• Molded blotting chamber with spin bar corral• 4 freezer blocks• 2 platinum electrode panels• 4 transfer cassettes with 4 sponge pads• 4 additional sponge pads• Safety cover with power leads

Mini-Blotting Systems

FeatUres• Temperature control is achieved through the use of freezer blocks on both ends of the reservoir, eliminating the need for an external cooling apparatus.• Capability of transferring 4 gels simultaneously under identical temperature controlled buffer conditions• Transfer cassette assembly consists of hinged, molded polycarbonate panels and sponge pads.• Color-coded components for correct polarity orientation.• Stirring bar can be placed beneath the cassettes to allow buffer

circulation, even temperature distribution and heat exchange during electrophoresis.

• Fits four gels with precast cassette or glass plate dimensions of 10cm x 10cm.

EBU-204 EBX-700EBU-204P