TENSION DISPLAY PANEL ALS8A101 2-3mv/v input signal Program Revision – 8A101F ALS8A101 PANEL TENSION AUG 2015 Rev F Page 1 of 43

TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

TENSION DISPLAY PANELALS8A101

2-3mv/v input signal

Program Revision – 8A101F

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 1 of 30

Page 2: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

TABLE OF CONTENTS

SECTION DESCRIPTION

1.0 QUICK START

2.0 GENERAL DESCRIPTION

3.0 DESCRIPTION OF BUTTONS & SWITCHES

4.0 MENU SELECTIONS

5.0 INSTALLATION AND MOUNTING

6.0 SPECIFICATONS

7.0 PARTS LISTS & DIAGRAMS

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 2 of 30

Page 3: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

1.0 QUICK START

Recommended Spare Parts List – ALS6A100

All parts listed are Critical Spares and are required to properly maintain this device.

We recommend that all customers stock the quantity indicated in the ‘QTY’ column. IF you are in a remote location or prefer having immediate availability of all spares, we recommend that you stock at least one of each item.

NOTE – BenchMark may not always have all spares in stock all the time.

P/N DESCRIPTION QTY REF

RECOMMENDED SPARE PARTS FOR ALL LOCATIONS

AMS4P569 LCD 6 DIGIT .71" REFLECTIVE TN LCD-S601C71TR LUMEX 0 Ref

ALS8A024 PCB ASSY TENSION BU LV 1  

AMS4P621 POWER SUPPLY 12V 7W 85-264ACIN CONDOR GSM11-12AAG 1  

AMS4P786 FUSE 0.5A 250V 5X20MM GLASS 2  

AMS4P618 BATTERY 1.2V NIMH AA ENERGIZER NH15BP-4 6  

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 3 of 30

Page 4: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

Obtaining Technical Assistance

Call BenchMark Wireline Products Inc. at +1 281 346 4300Or contact by email [email protected] fax in request at +1 281 346 4301

Information is also available on website www.benchmarkwireline.com

Parts can be ordered by email, phone, or fax.

Equipment can be returned for repair and maintenance. Please notify us by Phone, email, or fax before sending any equipment.

To return equipment to BenchMark, ship it to:BenchMark Wireline Products36220 FM 1093Simonton, Texas 77476U.S.A.

Note – For better response, please have the Part Number available.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 4 of 30

Page 5: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

2.0 GENERAL DESCRIPTION

The Tension Display panel is designed to be an independent, low voltage tension measurement indicator for mounting inside a wireline unit. The tension signal is read from a load cell connected to a wireline sheave or from a load pin in the measuring head. It can be displayed in either pounds or kilograms at the display unit. The unit is powered by three internal batteries. It can be connected to an external AC or DC power source to keep the batteries charged. An external output is provided to allow the panel to be connected to an analog gauge to show tension.

The unit is designed to operate without intervention from the user. When external power fails, the display is maintained by the batteries. If the input is inactive for more than one hour the unit switches itself off.

Front panel controls allow the operator to:Zero the tension readingSelect a different settings using the menu buttonSwitch the power off manually (for use when running on battery power)

The unit is switched on automatically, when external power is restored, or when the user selects the enable switch on the front panel.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 5 of 30

Page 6: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 6 of 30

Page 7: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

3.0 DESCRIPTION OF BUTTONS & SWITCHES

3.1 ENABLEThe ENABLE/OFF switch is a center-biased three position switch. The unit cannot be switched off when connected to external power.

The display unit forces you to use two switches, to prevent accidental loss or corruption of the depth display value.

The up position (ENABLE) is required to zero the tension.

3.2 MENU

This button is used to change the internal settings of the panel. These settings include Load Cell type, Scales, Load Cell Angles, English/Metric units, etc. Refer to Section 4 for detailed description of these features.

3.3 ZEROThe ZERO button allows you to zero the display. It is a two position momentary switch. To activate this switch, you must hold the ‘ENABLE’ switch up, then press this button.

3.4 “+/-“The INCREASE/DECREASE switch is a center biased three position switch. Use this switch to change values in each menu.

3.5 EXT PWR LED

There is one LED on the front panel of the display unit. The LED is lit when the unit is connected to an external power source, either 240/120 vac or 12 vdc. If the LED is not lit, then the unit is operating on of battery power.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 7 of 30

Page 8: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.0 MENU SELECTIONS

This panel may be configured by scrolling through settings using the MENU button.

IMPORTANT NOTE: To change an input value, press and release the MENU button until the desired setting is displayed. Use the ‘+/-‘ switch to change the setting. After a setting is changed, continue pressing the MENU button until you pass the last setting. You will then be asked if you want to ACCEPT the setting changes. To ACCEPT the changes press ‘+’ then the MENU button. If you press ‘–‘ or wait for four seconds, the changes will be ignored. If you wait for four seconds between button presses, the panel will time out.

4.1 HEAD TYPEPress the MENU button again and the panel displays ‘hd’ for Head type. Select: the Head Type from this list.

- HDSTND - test stand

- HDLC - load cell

- HDSN78 - passive ATEX certified

- HD5BU - AM5K backup

- HD5NA - AM5K not amplified

- HD5A - AM5K amplified

- HD3NA - AM3K not amplified

- HD3A - AM3K amplified

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 8 of 30

Page 9: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

NOTE – after the HEAD TYPE has been chosen, only the menu items that pertain to that head type will be displayed.

4.2 LINE SIZE

When the MENU button is pressed once the LINE SIZE is stored in the system. Use the ‘+/-‘ switch to change the display until desired line size setting is displayed.

Fractional values will be displayed like this

Decimal values will be displayed like this Line sizes will be displayed as the following options. Select a line size.

7-329-325-163-87-1615-32ht472472ht48449217-329-16

NOTE – the “ht” designates High Tension or Deep Groove tension wheels.

4.3 SENSITIVITY NUMBER

Press the MENU button again and the SN Sensitivity Number menu item will be displayed. You will have to input that value. It is found on the ID plate on the load cell.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 9 of 30

Page 10: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.4 FULL SCALE

Press the MENU button again and the FS Full Scale menu item will be displayed and you will have to input the value. This is found on the ID plate on the load cell.

4.5 SHUNT CAL

Press the MENU button again and the SC Shunt Cal menu item will be displayed. This value is automatically calculated by the panel based on other inputs. Immediately after that, the SC Off message will be displayed indicating that the value has now been erased.

4.6 ANGLE

Press the MENU button again and the ANGLE menu item will be displayed. The system assumes and displays “0” zero. If the angle of the wire is anything other than that, primarily because a sheave is being used, calculate the angle and enter that value.

4.7 UNIT OF MEASURE

Press the MENU button again and the panel displays ‘un’ for UNIT OF MEASURE. Either LB pounds or KG kilograms must be selected.

4.8 TENSION HOLD – ZERO

Press the MENU button again and the panel displays ‘TENSION HOLD’. This indicates the maximum tension value recorded on the panel.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 10 of 30

Page 11: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.9 ACCEPT Y/N

Press the MENU button again and the panel displays ACCEPt. If you want to accept the changes put the ‘+/-‘ switch in the ‘+’ position. The panel displays YES. Pushing the menu button writes the new values to flash. If you want to discard the changes put the ‘+/-‘ switch to the ‘-‘ position. The panel displays NO. Push the menu button again.

4.10 MENU MAPS

The following pages provide a complete MENU MAP for each type of Measuring Head. Select the head attached to the Tension Panel and the map will show the menu selections in order as they appear on the panel.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 11 of 30

Page 12: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.1 MENU SELECTIONS - MEASURING HEAD - TEST STAND

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 12 of 30

Page 13: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.2 MENU SELECTIONS – MEASURING HEAD - LOAD CELL

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 13 of 30

Page 14: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.3 MENU SELECTIONS - MEASURING HEAD - SN78

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 14 of 30

Page 15: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.4 MENU SELECTIONS – MEASURING HEAD - 5BU

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 15 of 30

Page 16: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.5 MENU SELECTIONS – MEASURING HEAD - 5NA

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 16 of 30

Page 17: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.6 MENU SELECTIONS – MEASURING HEAD - 5A

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 17 of 30

Page 18: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.7 MENU SELECTIONS – MEASURING HEAD - 3NA

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 18 of 30

Page 19: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

4.10.8 MENU SELECTIONS – 3A

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 19 of 30

Page 20: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

5.0 INSTALLATION AND MOUNTING

5.1 INSTALLATION PROCEDURE

5.1.1 Prepare an appropriate panel cut-out with four fixing holes (refer to drawing in section 5.2) or use one of the two mounting brackets shown in (section 5.2).

5.1.2 Connect the tension input cable to the rear of the unit.

5.1.3 Ensure that power is off. Connect the unit to a 12vdc or 120/240 vac power supply.

5.1.4 Insert the display unit into the panel and secure it at the four corners.

5.1.5 Ensure that the unit is setup for the desired measurement units (pounds or kilograms).

5.1.6 Before you start to use the display unit, leave it connected to the external power for 4 hours to ensure that the batteries are fully charged.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 20 of 30

Page 21: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

5.2 MOUNTING KITS

AMS4A161 PIVOTING MOUNT

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 21 of 30

Page 22: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

5.2 MOUNTING KITS continued

AMS4M110 PLATE MOUNT

TOP VIEW

FRONT VIEW SIDE VIEW

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 22 of 30

Page 23: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

6.0 SPECIFICATIONS

6.1 Mechanical

Material Aluminium, anodized Weight 1.5 lbs (.68 kg)Mounting 4 .019 holes

fixing centers: 6.19” (19.05 cm) from side, 2” (5.08 cm) from top/bottom.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 23 of 30

Page 24: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

6.2 Environmental

IP Rating 40Temperature 0 to + 50 CentigradeHumidity 10% - 80% RH non-condensing.

6.3 Electrical

Input power Voltage 100 - 240 VAC or 12 – 24 VDCInput power frequency 50 - 60 Hz, DCInput power current 0.4 A

6.4 Batteries

Battery 2100 mAhVoltage 1.2 V NIMHLifetime Approx. 5 years (depending on usage)

The batteries are trickle charged when external power is connected to the unit. The batteries are fully charged after 3 hours. The batteries discharge if the unit is left unpowered for a few weeks.

6.5 AC Power Input

Live Brown WhiteNeutral Blue BlackEarth Green/Yellow Green

Power is fused inside the display unit case with a 250 mA fuse.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 24 of 30

Page 25: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

6.6 DC Power-input

Live Pin 1Neutral Pin 2Earth Pin 3

DC connector spec: AMS4P257 -CONN KPT06E8-33P 3 PIN

The battery voltage and charge current can be displayed by pressing enable and menu at the same time.

The voltage will be displayed as:

E 4180

4180 would be a battery voltage of 4.18 volts. When the battery reaches 4.8v the charge will stop.

The charge current will be displayed as:

A 310

310 would be a battery charge current of 310 ma.

The display will cycle between the voltage and current display as long as the buttons are being depressed.

The charge current is limited to between 250 ma and 350 ma.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 25 of 30

Page 26: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

7.0 PARTS LISTS AND DIAGRAMS

7.1 PARTS LISTS ALS8A101 TENSION DISPLAY PANEL

P/N DESCRIPTION QTY REF

ALS8A101 PANEL AMS TN BKUP AMP 2MV/V AM5K LOAD PIN OR PANCAKE LOAD CELL 110/240VAC - 12/24VDC    

ALS6M001-2 PANEL FR TENSION BKUP PNL MT 1  ALS8M002 PANEL REAR TENS BKP 1  ALS6M004 CHASSIS BACKUP DISPLAY PNL TOP 1  ALS6M005 CHASSIS BACKUP DISPLAY PNL BTM 1  

AMS4P171 CONN KPSE02E12-10S RECEPTACLE 10 SOCKETS 1 LOAD CELL

AMS4P257 CONN KPT02E8-33P RECEPTACLE MS3112 1  ALS4P020 CONN JACK BNC STRGHT 50OHM ISO 1 TENS OUTAMS4P569 LCD 6 DIGIT .71" REFLECTIVE TN LCD-S601C71TR LUMEX 0 RefALS8A024 PCB ASSY TENSION BU LV 1  AMS4P621 POWER SUPPLY 12V 7W 85-264ACIN CONDOR GSM11-12AAG 1  C276P155 CABLE BELDEN 177431 10' AC LINE INPUT 1  AMS4P276 RECEPTACLE 115/240 VAC FUSED EMI FILTERED 2 AMP 1  AMS4P786 FUSE 0.5A 250V 5X20MM GLASS 2  AMS4P618 BATTERY 1.2V NIMH AA ENERGIZER NH15BP-4 6  ALS8M057 TRAY BATTERY 6XAA BK TENSN 1  ALS8M037 CLAMP BATTERY 6XAA BKUP TENSN 1  ALS8P042 SPACER ROUND PHENLC #6 X 1-1/2 NON-THREADED 2  AMS4P021 SWITCH CAP ALCO C-22 BLACK 1 MENU SWAMS7P017 SWITCH CAP ALCO C-22 RED 1 ZERO SWC276P046 WASHER #6 LOCK SS 2  ALS8P043 SCREW 6-32 X 2 PHIL PAN SST 2  AMS4P631 NUT 1/4-40 DRESS BRIGHT NICKEL 0.460 DIA X 0.090 THK 4  AMS4P659 CONN TERMINAL RECPTACLE .25TAB AMP 2-520184-2 3  AMS7P022 CONN 102398-6 AMP 16 POS PCB HARNESS BODY 1 102398-4AMS7P026 CONN 102536-6 AMP 16 POS BACK COVER 1  AMS7P025 CONN 102681-3 AMP 16 POS FRONT COVER 1  AMS4P661 CONN HOUSING 3POS 2.5MM SHROUD MOLEX 50-37-5033 1  AMS4P662 CONN FE TERMINAL CRIMP 2.5MM MOLEX 08-70-1040 4  AMS4P663 CONN HOUSING 2POS 2.5MM SHROUD MOLEX 50-37-5023 1  ALS8P041 HOLDER BATT 6AA W 9V SNAP CON 1  

ALS6P033 SCREW 4-40 X 3/16 FH PHIL SST 2 BATTERY HOLDER

ALS6P085 SCREW 4-40 X 1/4 FH PHIL SST 14  AMS8P091 SCREW 4-40 X 1/4 PHIL PAN SST 12  AMS8P036 WASHER #4 LOCK SST 12  ALS4P019 CONN HOUSING CRIMP 2CKT .100 1  ALS4P014 CONN TERM CRIMP 24-30AWG MOLEX 08-50-0005 2  

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 26 of 30

Page 27: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

7.3 BATTERY REPLACEMENT

Note position of the three batteries.

USE ONLY 1.2V NIMH AA 2100MAH BATTERIES

WARNING

DO NOT USE NON RECHARGEABLE BATTERIES AS THEY ARE LIKELY TO EXPLODE WHEN CHARGED

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 27 of 30

Page 28: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

7.4 USB DISK ADAPTER

SOFTWARE UPDATE

In the event of a required software update the ALS8A101 tension panel must be re-programmed with the ALS9K211 USB Debug Adaptor connected to a computer using the Silicone Laboratories Flash Programming utility. This can be downloaded from the Silicone Laboratories website. Search for, silicon labs – support – downloads – 8 bit production programmer.

Remove the cover of the ALS8A101 backup depth panel and connect the 20 pin connector to the HDR2 header and then apply power.

Next connect the USB Connector to a computer and start the Silabs flash programming utility.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 28 of 30

Page 29: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

RE-PROGRAMMING INSTRUCTIONS

Refer to the following figure and ensure that connects/disconnects dialogue screen is configured accordingly.

Click on the Connect Button and the utility will respond with a “CONNECTED” message.

Now click on the “Download Hex File/Go/Stop” tab near the top of the dialog and next refer to the next figure.

ALS8A101 PANEL TENSION AUG 2015 Rev F Page 29 of 30

Page 30: TELEFAX COVER SHEET WORD/12_ALS8A101 manual p…  · Web viewp/n description qty ref als8a101 panel ams tn bkup amp 2mv/v am5k load pin or pancake load cell 110/240vac - 12/24vdc

DOWNLOAD HEX FILE/GO/STOP DIALOG

Click on the “Browse” button and locate the new software Hex File for the ALS6A100 backup depth panel.

Next click on the “Download –Ad” and the utility will respond with a “Downloaded” message. Next click on the “Go” button and the utility will respond with a “Go” message.

Note – DO NOT press “STOP”.

Close the utility and cycle-power on the ALS6A100 Backup Depth Panel to confirm that the new software has been added by noting the displayed version number.