OPERATIONS AND MAINTENANCE MANUAL FSU1A196 BARRIER BOX HALLIBURTON ENERGY SERVICES FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 1 of 34

TELEFAX COVER SHEET - BenchMark Wirelinebenchmarkwireline.com/HES WORD/7_FSU1A196 UserM…  · Web viewproduct description. saftey ... loop isolator 4-20ma 1 ea pressure 12 fsu1m196

Embed Size (px)

Citation preview

OPERATIONS AND MAINTENANCE MANUALFSU1A196 BARRIER BOX

HALLIBURTON ENERGY SERVICES

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 1 of 26

TABLE OF CONTENTS

SECTION DESCRIPTION

1.0 GENERAL INFORMATION

1.1 PRODUCT DESCRIPTION1.2 SAFTEY STANDARDS & ATEX REQUIREMENTS1.3 TYPE EXAMINATION CERTIFICATES1.4 TECHNICAL SPECIFICATIONS1.5 HAZARDOUS AREA PREPARATION AND INSTALLATION1.6 ASSEMBLY AND DISMANTLING1.7 MAINTENANCE1.8 OBTAINING TECHNICAL ASSISTANCE

2.0 EQUIPMENT MAINTENANCE AND WIRING INFORMATION

Manual Revision Log

Current Revision C SEP 2009

Initial Release

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 2 of 26

1.0 GENERAL INFORMATION1.1 PRODUCT DESCRIPTION

This device contains the necessary I.S. barriers and power supply needed for operation in a zone 2 environment.

The use of this equipment along with the proper sensors and power source makes the AMS4A095 Slickline Hoistman’s Touch Screen Panel panel safe for use in a hazardous area.

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 3 of 26

1.2 ATEX STANDARDS & REQUIREMENTS

INTENDED USE OF EQUIPMENT

The FSU1A196 Barrier Box is intended to provide a protected mounting enclosure for I.S. barriers and power supply. The enclosure protects the barriers from the environment to assure that they will function to specification.

PRODUCT CERTIFICATION & CODING

II 3 G Ex nR II T6 Tamb -20°C to +40°C

INSTALLATION INSTRUCTIONS

Warnings:

o The apparatus is ATEX CAT3, only to be installed in Hazardous Area Zones 2.

o The installer is to ensure that the equipment is located in areas that are known not to have an adverse affect on the housing material.

o Do not modify the enclosure as this will compromise the apparatus certificate.

Hazardous Area Installation Standards & Requirements:

The installer should refer to the latest edition of the following standards before operating in a Hazardous Area:

EN 1127-1 Explosive Atmospheres - Explosion prevention and protection, basic concepts and methodology.

EN 60079-14 Electrical apparatus for explosive gas atmospheres Part 14:Electrical installations in hazardous areas (other than mines)

EN 60079-17 Electrical apparatus for explosive gas atmospheres – Part 17:Inspection and maintenance of electrical installations in hazardous areas (other than mines)

Preparation & Installation - Refer to section 1.5Assembly and Dismantling - Refer to section 1.6Maintenance - Refer to Section 1.7Operational Parameters - Refer to Section 1.3

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 4 of 26

ATEX Label Details and Information

The following standards have been applied in the certification of this device:

EN60079-0:2006 – Electrical apparatus for explosive gas atmospheres – Part 0: General requirements

EN60079-15:2005 – Electrical apparatus for explosive gas atmospheres – Part 15: Construction, test and marking of type of protection “n” electrical apparatus.

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 5 of 26

1.3 TYPE EXAMINATION CERTIFICATES

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 6 of 26

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 7 of 26

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 8 of 26

1.4 TECHNICAL SPECIFICATIONS

WEIGHT: 25 LBS 11.3 KG

POWER REQUIREMENTS:

INPUT VOLTAGE: 120 – 240 VAC @ 50/60 HZMAXIMUM CURRENT

(@120VAC) .8 AMPS(@240VAC) .4 AMPS

INPUT POWER: 95 WATTS STARTUP SURGE85 WATTS NORMAL OPERATION

OPERATING TEMPERATUREMin Max -4 131 degrees F-20 55 degrees C

STORAGE TEMPERATUREMin Max-40 167 degrees F-40 75 degrees C

Maximum Ratings relating to maximum surface & operating temperatures:

Maximum operating ambient temperature range = -20°C to +40°C

Electronic short circuit protection current limitation at Imax. constant current, automatic recoveryOutput overvoltage protection 35 VDCOverload protection electronic overload protectionOvertemperature protection switch off at overtemperature, automatic restartPower back immunity 35 VDC

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 9 of 26

PHYSICAL DIMENSIONS

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 10 of 26

1.5 HAZARDOUS AREA PREPARATION AND INSTALLATION

This equipment is to be installed only by suitably trained and qualified personnel to local national codes.

1. Provide four mounting holes to bolt each of the four mounting tabs located near each of the four corners. The top holes (slotted tabs) should accept a 3/8” (9 mm) bolt and the bottom holes should be ¼” (6 mm) bolt.

2. Mount the box and secure it with the bolts.

3. Open the lid using the Key provided with the enclosure.

4. Verify the power source:

Input voltage range 85 – 132/187 – 264 VAC

Input frequency 47 to 63 HZ.

Harmonic limits EN 61000-3-2, Class A (for limited output power)

Holdup time 20 ms min. (full load 115/230 VAC)Inrush current < 13 A (115 VAC) < 25 A (230 VAC)

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 11 of 26

5. Verify that the mains supply provided by the customer includes a suitable circuit breaker. Recommended circuit breaker, – TSP 070/090 6.0 Acharacteristic C – TSP 140/180 6.0 A

6. Insert power cable into box through appropriate cable gland such as HAWKE 501/414/M20/M20 or equivalent.

Flameproof and Increased SafetyCable Gland Type

ATEX Flameproof and Increased Safety

Metric entry threads are 1.5mm pitch as standard.Thread length is 15mm Assembly instruction data sheet No. A.I. 310.

7. Connect Electrical Power

Connect a cable from the power source through the power input gland to the terminal block on the power din rail mounted power supply.

PS1 - L BLK T9 - 3 TERMINAL BLOCK 120/240VAC LINE

PS1 - N WHT T8 - 2 TERMINAL BLOCK 120/240VAC NEUTRAL

PS1 - GND GRN T7 - 2 TERMINAL BLOCK 120/240VAC GND

8. CONNECT INPUT SIGNAL CABLES

Connect the cables from the measuring head to the load pin in and encoder in connectors on the box.

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 12 of 26

.6. CONNECT OUTPUT SIGNAL CABLES

Connect the INT2 and EXT cables from the AMS4A095 Computer Panel to the INT2 and EXT connectors on the box.

Connect the Shutdown Relay cable from the box to the Hoist Shutdown valve.

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 13 of 26

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 14 of 26

1.6 ASSEMBLY AND DISMANTLING

During normal operations, this equipment requires no additional assembly or dismantling in addition to the information provided in section 1.5 (Preparation & Installation).

Below are diagrams showing the equipment fully assembled.

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 15 of 26

1.7 MAINTENANCE

If the equipment is used in a manner not specified by the manufacturer, the protection by the equipment may be impaired.

The equipment is restricted breathing apparatus and the restricted breathing properties of the enclosure shall be measured as dictated in EN60079-17. The test shall be conducted in accordance with Clause 33.7.1 of EN60079-15:2005.

To verify that the box has maintained its seal and developed no leaks, it should be periodically tested by pulling a vacuum on it. A Restricted Breathing Test Point is installed (shown below) to provide a means to perform this test.

1.8 OBTAINING TECHNICAL ASSISTANCE

Call BenchMark Wireline Products Inc. at +1 281 346 4300Or contact by email [email protected] fax in request at +1 281 346 4301Information is also available on website www.benchmarkwireline.comParts can be ordered by email, phone, or faxEquipment can be returned for repair and maintenance. Please notify us by Phone, email, or fax before sending any equipment.To return equipment to BenchMark, ship it to:BenchMark Wireline Products36220 FM 1093Simonton, Texas 77476U.S.A.

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 16 of 26

2.0 EQUIPMENT MAINTENANCE AND WIRING INFORMATION

2.1 DRAWINGS AND BOM

P/N DESCRIPTION QTY UM REFERENCE1 AMS5P014 BARRIER TENSION L.V. IN 1 EA TENSION2 AMS5P008 BARRIER TENSION SHUNT CAL 1 EA SHUNT3 AMS7P203 BARRIER I.S. ENCODER POWER 1 EA 4 AMS7P204 BARRIER I.S. ENCODER SIGNAL 2 EA 6 AMS7P206 BARRIER TENSION SHUTDOWN RELAY 1 EA 8 AMS5P058 POWER SUPPLY 120AC TO 24VDC 1 EA 9 C276P620 BARRIER LOOP ISOLATOR 4-20mA 1 EA PRESSURE

12 FSU1M196 ENCLOSURE MOD SIGNAL I/O 95 Z2 1 EA 13 FSU1M159 PANEL BARRIER MOUNTING SIG IO 1 EA 14 FSU1M160 DIVIDER BARRIER PLATE SIG IO 1 EA 20 FSU1M161 RAIL DIN BARRIER MTG SIG IO 1 EA 23 AMS5P100 CONN KPT07E8-33P JAM NUT 1 EA CAN24 AMS5P101 CONN KPSE07E14-15P JAM NUT 1 EA INT-2/DC POWER25 AMS5P105 CONN BFR18-9P-1 JAM NUT 1 EA LOAD CELL IN26 AMS5P106 CONN BFR18-1P-1 JAM NUT 1 EA ENCODER IN27 AMS5P102 CONN KPSE07E14-19P JAM NUT 1 EA EXT

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 17 of 26

31 AMS5P103 CONN KPSE07E10-6S JAM NUT 2 EA PRESSURE 1 & 233 AMS5P115 CONN USBFTV71G JAM NUT USB 1 EA USB34 AMS5P107 CONN BFR14S-9S-1 JAM NUT 1 EA OVER TENSION OUT35 AMS5P104 CONN KPSE07E10-6P JAM NUT 1 EA RS23249 AMS5P118 DUST CAP 10-329392-18 MS TYPE 2 EA 50 AMS5P121 DUST CAP KPT8110N RECEPT 3 EA 52 AMS5P117 DUST CAP 10-329392-14 MS TYPE 1 EA 53 AMS5P116 DUST CAP USB FWFTVC7G JAM NUT 1 EA 54 AMS5P120 DUST CAP KPT8114N RECEPT 2 EA 55 FSU1P205 GLAND CABLE M20 7.5-11.9MM 1 EA 57 FSU1P208 NUT M20 X 1.5 LOCK CABLE GLAND 1 EA 80 FSU1P213 PLUG 1/4 NPT BRASS 1 EA 81 FSU1P211 BLKHD 1/4NPT BRS 1 EA 82 FSU1P212 WASHER 3/4 FLAT NYLON 6/6 1 EA 91 C276P607 STOP END 35MM DIN RAIL TERM 4 EA 92 C276P608 PLATE END 35MM DIN RAIL TERM 2 EA 93 C276P609 JUMPER DIN RAIL 2-POLE TERM ST 3 EA 94 C276P610 TERMINAL DUAL 35MM DIN RAIL 4 EA 95 C276P613 TERMINAL GND 35MM DIN RAIL GRN 3 EA 97 C276P616 TAG MARKING 1-10 DIN RAIL T ST 1 EA

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 18 of 26

2.2 WIRE LIST

B1 OVER TENSION SHUTDOWN BARRIER  

B2 ENCODER SIGNAL BARRIER

B3 ENCODER SIGNAL BARRIER    

B4 ENCODER POWER BARRIER   

B5 LOW VOLTAGE TENSION BARRIER  

B6 TENSION SHUNT CAL BARRIER  

B7 DUAL PRESSURE TRANSDUCER BARRIER  

J1 EXT          

J2 INT-1/ DC POWER     

J3 RS232          

J4 USB          

J5 CAN          

J6 OVER TENSION CONTACT    

J7 ENCODER     

J8 LOAD CELL     

J9 PRESSURE 1  

J10 PRESSURE 2  

PS1 120VAC TO 24VDC POWER SUPPLY  

J1 - EXT CONNECTOR

J1 - A YEL 22 B2 - 1 ENCODER SIGNAL BARRIER B2 ENCODER A

J1 - B BLU 22 B2 - 2 ENCODER SIGNAL BARRIER B2 ENCODER B

J1 - C ORN 22 B3 - 1 ENCODER SIGNAL BARRIER B3 ENCODER A\

J1 - D GRY 22 B3 - 2 ENCODER SIGNAL BARRIER B3 ENCODER B\

J1 - E RED 20 B4 - 1 ENCODER POWER BARRIER B4 ENCODER +5VDC

J1 - F BLK 20 B4 - 2 ENCODER POWER BARRIER B4 ENCODER GND

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 19 of 26

J1 - G YEL 22 B5 - 5 LOAD CELL BARRIER B5 4 TO 20MA IN

J1 - H BLK 20 T4 - 2 PS1 24VDC GND GND

J1 - J WHT 20 B5 - 3 LOAD CELL BARRIER B5 +24VDC

J1 - K GRY 22 B6 - 5 SHUNT CAL BARRIER B6 SHUNT CAL

J1 - L GRN 22 B1 - 8 OVER TENSION BARRIER B1

TENSION SHUTDOWN NO

J1 - M BRN 22 B1 - 7 OVER TENSION BARRIER B1

TENSION SHUTDOWN COM

J1 - N RED 22 J4 - RED WIRE USB CONNECTOR J4 USB VCC

J1 - P WHT 22 J4 - WHT WIRE USB CONNECTOR J4 USB D0-

J1 - R GRN 22 J4 - GRN WIRE USB CONNECTOR J4 USB D0+

J1 - S BLK 22 J4 - BLK WIRE USB CONNECTOR J4 USB GND

J1 - T YEL 22 J3 - A RS-232 CONNECTOR RS232 TX COM 3

J1 - U BLU 22 J3 - B RS-232 CONNECTOR RS232 RX COM 3

J1 - V BLK 22 J3 - C RS-232 CONNECTOR RS232 GND

J2 - INT-2/DC POWER CONNECTOR

J2 - A WHT 22 J5 - A CAN BUS CONNECTOR J5 CAN_H

J2 - B VIO 22 J5 - B CAN BUS CONNECTOR J5 CAN_L

J2 - C BLK 22 J5 - C CAN BUS CONNECTOR J5 GND

J2 - D WHT 20 T1 - 1 POWER SUPPLY 24VDC TO PANEL

J2 - E BLK 20 T3 - 1 POWER SUPPLY GND

J2 - F BLU 22 B7 - 9 PRESSURE BARRIER B7 PRESSURE 1

J2 - G GRY 22 B7 - 11 PRESSURE BARRIER B7 PRESSURE 2

J2 - J BLK 22 B7 - 8 PRESSURE BARRIER B7 GND

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 20 of 26

J3 - RS232 40 PCB COM 3J3 - A YEL 22 J1 - T EXT CONNECTOR J1 RS232 TX COM 3

J3 - B BLU 22 J1 - U EXT CONNECTOR J1 RS232 RX COM 3

J3 - C BLK 22 J1 - V EXT CONNECTOR J1 RS232 GND

J4 - USB CONNECTORJ4 - RED RED 22 J1 - N EXT CONNECTOR J1 USB VCC

J4 - WHT WHT 22 J1 - P EXT CONNECTOR J1 USB D0-

J4 - GRN GRN 22 J1 - R EXT CONNECTOR J1 USB D0+

J4 - BLK BLK 22 J1 - S EXT CONNECTOR J1 USB GND

J5 - CAN BUS CONNECTOR

J5 - A WHT 22 J2 - A INT 2/DC POWER CONNECTOR CAN_H

J5 - B VIO 22 J2 - B INT 2/DC POWER CONNECTOR CAN_L

JA - C BLK 22 J2 - C INT 2/DC POWER CONNECTOR GND

J6 - OVER TENSION CONTACT

J6 - A GRN 20 B1 - 1 OVER TENSION BARRIER B1

TENSION SHUTDOWN NO

J6 - B BRN 20 B1 - 2 OVER TENSION BARRIER B1

TENSION SHUTDOWN COM

J7 - ENCODER CONNECTOR

J7 - A YEL 22 B2 - 3 ENCODER SIGNAL BARRIER B2 ENCODER A

J7 - B BLU 22 B2 - 4 ENCODER SIGNAL BARRIER B2 ENCODER B

J7 - D RED 22 B4 - 3 ENCODER POWER BARRIER B4 ENCODER 5VDC

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 21 of 26

J7 - F BLK 22 B4 - 4 ENCODER POWER BARRIER B4 ENCODER GND

J7 - H ORN 22 B3 - 3 ENCODER SIGNAL BARRIER B3 ENCODER A\

J7 - I GRY 22 B3 - 4 ENCODER SIGNAL BARRIER B3 ENCODER B\

J8 - LOAD CELL CONNECTOR

J8 - A BLU 22 B5 - 13 LOAD CELL BARRIER B5 LOAD CELL SIG+

J8 - B BLK 20 B5 - 14 LOAD CELL BARRIER B5 LOAD CELL SIG-

J8 - C WHT 20 B5 - 9 LOAD CELL BARRIER B5 LOAD CELL 12VDC

J8 - E BLK 20 B5 - 12 LOAD CELL BARRIER B5LOAD CELL 12VDC GND SENSE

J8 - G GRN 22 B6 - 13 LOAD CELL SHUNT CAL BARRIER B6 SHUNT CAL

J9 - PRESSURE 1 CONNECTOR

J9 - A BLU 22 B7 - 4 PRESSURE BARRIER B7 PRESSURE 1+

J9 - B BLK 22 B7 - 5 PRESSURE BARRIER B7 PRESSURE 1 GND

J10 - PRESSURE 2 CONNECTOR

J10 - A GRY 22 B7 - 1 PRESSURE BARRIER B7 PRESSURE 2+

J10 - B BLK 22 B7 - 2 PRESSURE BARRIER B7 PRESSURE 2 GND

B1 - OVER TENSION SHUTDOWN BARRIER

B1 - 1 GRN 22 J6 - A OVER TENSION CONTACT CONNECTOR J6

TENSION SHUTDOWN NO

B1 - 2 BRN 22 J6 - B OVER TENSION CONTACT CONNECTOR J6

TENSION SHUTDOWN COM

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 22 of 26

B2 - ENCODER SIGNAL BARRIER 1B2 - 1 YEL 22 J1 - A EXT CONNECTOR J1 ENCODER A OUT

B2 - 2 BLU 22 J1 - B EXT CONNECTOR J1 ENCODER B OUT

B2 - 3 YEL 22 J7 - A ENCODER CONNECTOR J7 ENCODER A IN

B2 - 4 BLU 22 J7 - B ENCODER CONNECTOR J7 ENCODER B IN

B3 - ENCODER SIGNAL BARRIER 2B3 - 1 ORN 22 J1 - C EXT CONNECTOR J1 ENCODER A\ OUT

B3 - 2 GRY 22 J1 - D EXT CONNECTOR J1 ENCODER B\ OUT

B3 - 3 ORN 22 J7 - H ENCODER CONNECTOR J7 ENCODER A\ IN

B3 - 4 GRY 22 J7 - I ENCODER CONNECTOR J7 ENCODER B\ IN

B4 - ENCODER POWER BARRIERB4 - 1 RED 20 J1 - E EXT CONNECTOR J1 ENCODER 5VDC

B4 - 2 BLK 20 J1 - F EXT CONNECTOR J1 ENCODER GND

B4 - 3 RED 20 J7 - D ENCODER CONNECTOR J7 ENCODER 5VDC

B4 - 4 BLK 20 J7 - F ENCODER CONNECTOR J7 ENCODER GND

B5 - LOW VOLTAGE TENSION BARRIERB5 - 3 RED 20 J1 - J EXT CONNECTOR J1 +24VDC

B5 - 4 BLK 20 T3 - 2 PS1 GND

B5 - 5 YEL 20 J1 - G EXT CONNECTOR J1 4 TO 20MA IN

B5 - 9 WHT 20 J8 - C LOAD CELL CONNECTOR J8

LOAD CELL 12VDC

B5 - 9 WHT 22 B5 - 10 LOAD CELL BARRIER B5 LOAD CELL 12VDC SENSE

B5 - 11 BLK 20 J8 - E LOAD CELL CONNECTOR J8

LOAD CELL SIG- SENSE

B5 - 11 BLK 22 B5 - 12 LOAD CELL BARRIER B5 LOAD CELL 12VDC GND

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 23 of 26

SENSE

B5 - 13 BLU 22 J8 - A LOAD CELL CONNECTOR J8 LOAD CELL SIG+

B5 - 14 BLK 20 J8 - B LOAD CELL CONNECTOR J8 LOAD CELL SIG-

B6 - SHUNT CAL BARRIERB6 - 3 WHT 22 T1 - 1 TERMINAL BLOCK PS1 24VDC

B6 - 4 BLK 22 T4 -1 TERMINAL BLOCK PS1 24VDC GND

B6 - 5 GRY 22 J1 - K EXT CONNECTOR J1 SHUNT CAL

B6 - 6 BLK 22 T4 - 1 TERMINAL BLOCK GND

B6 - 13 GRN 22 J8 - G LOAD CELL CONNECTOR J8 SHUNT CAL

B6 - 15 WHT 22 B5 - 10 LOAD CELL BARRIER B5 LOAD CELL 12VDC

B7 - DUAL PRESSURE TRANSDUCER BARRIER

B7 - 1 GRY 22 J10 - A PRESSURE 2 CONNECTOR J10 PRESSURE 2+

B7 - 2 BLK 22 J10 - B PRESSURE 2 CONNECTOR J10 PRESSURE 2 GND

B7 - 4 BLU 22 J9 - A PRESSURE 1 CONNECTOR J9 PRESSURE 1+

B7 - 5 BLK 22 J9 - B PRESSURE 1 CONNECTOR J9 PRESSURE 1 GND

B7 - 8 BLK 22 J2 - J INT 2/DC POWER CONNECTOR PRESSURE 1 GND

B7 - 9 BLU 22 J2 - F INT 2/DC POWER CONNECTOR PRESSURE 1+

B7 - 10 BLK 22 B7 - 8 DUAL PRESSURE TRANSDUCER BARRIER PRESSURE 1 GND

B7 - 11 GRY 22 J2 - G INT 2/DC POWER CONNECTOR PRESSURE 2+

B7 - 12 BLK 22 B7 - 10 DUAL PRESSURE TRANSDUCER BARRIER PRESSURE 2 GND

PS1 - 120/240VAC TO 24VDC POWER SUPPLY

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 24 of 26

PS1 - L BLK 18 T9 - 3 TERMINAL BLOCK 120/240VAC LINE

PS1 - N WHT 18 T8 - 2 TERMINAL BLOCK 120/240VAC

NEUTRALPS1 - GND GRN 18 T7 - 2 TERMINAL BLOCK 120/240VAC GND

PS1 - (-) BLK 18 T3 - 4 POWER SUPPLY PS1 24VDC GND

PS1 - (-) BLK 18 T4 - 4 TERMINAL BLOCK PS1 24VDC GND

PS1 - (+) WHT 18 T1 - 4 POWER SUPPLY PS1 24VDC

PS1 - (+) WHT 18 T2 - 4 TERMINAL BLOCK PS1 24VDC

T1 - TERMINAL BLOCK 24VDC

T1 - 1 WHT 20 J2 - D INT 2/DC POWER CONNECTOR PS1 24VDC

T1 - 1 WHT 22 B6 - 3 SHUNT CAL BARRIER PS1 24VDC

T1 - 3 WHT 18 PS1 - (+) POWER SUPPLY PS1 24VDC

T1 - 3 WHT 20 T2 - 3 POWER SUPPLY PS1 24VDC

T1 - 4 WHT 18 PS1 - (+) POWER SUPPLY PS1 24VDC

T2 - TERMINAL BLOCK 24VDCT2 - 3 WHT 20 T1 - 3 TERMINAL BLOCK PS1 24VDC

T2 - 4 WHT 20 PS1 - (+) POWER SUPPLY PS1 24VDC

T3 - TERMINAL BLOCK 24VDC GND

T3 - 1 BLK 20 J2 - E INT 2/DC POWER CONNECTOR PS1 24VDC GND

T3 - 2 BLK 20 B5 - 4 LOAD CELL BARRIER B5 PS1 24VDC GND

T3 - 3 BLK 20 T4 - 3 TERMINAL BLOCK PS1 24VDC GND

T3 - 4 BLK 20 PS1 - (-) POWER SUPPLY PS1 PS1 24VDC GND

T4 - TERMINAL BLOCK 24VDC GND

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 25 of 26

T4 - 1 BLK 20 B6 - 6 SHUNT CAL BARRIER PS1 24VDC GND

T4 - 2 BLK 20 J1 - H EXT CONNECTOR J1 PS1 24VDC GND

T4 - 3 BLK 20 T3 - 3 TERMINAL BLOCK PS1 24VDC GND

T4 - 4 BLK 18 PS1 - (-) POWER SUPPLY PS1 PS1 24VDC GND

T5 - TERMINAL BLOCK CHASSIS GNDT5 - 1 GRN 20 T6 - 1 TERMINAL BLOCK CHASSIS GND

T6 - TERMINAL BLOCK CHASSIS GNDT6 - 1 GRN 18 T7 - 1 TERMINAL BLOCK CHASSIS GND

T7 - TERMINAL BLOCK CHASSIS GNDT7 - 1 GRN 18 T6 - 1 TERMINAL BLOCK CHASSIS GND

T7 - 1 GRN 18 TERMINAL LUG TERMINAL LUG IN CHASSIS CHASSIS GND

T8 - TERMINAL BLOCK 120VAC NEUTRAL T8 - 2 BLU 18 PS1 - N POWER SUPPLY PS1 120VAC NEUTRAL

T9 - TERMINAL BLOCK T9 - 2 BLK 18 PS1 - L POWER SUPPLY PS1 120VAC LINE

FSU1A196 BARRIER BOX USER MANUAL Rev C NOV 2009 Page 26 of 26