26 APPLICATION Heat shrinkable indoor termination are used for, energy cables, power house, electrical distribution points, any moisture ambient. During the mounting of heat shrinkable termination, do not apply the fire on the tube surface not fixed, must apply with circular movements. Indoor termination can apply for only in closed areas. Shed number is changes according to rated voltage and type of terminations. SuItable Cable Types Use for, PVC insulations, XLPE, armour cables, mining, airport lighting cables. TechnIcal Data Water Absorption : ASTM D 570 Low Temperature Flexibility : -400C/4 Hrs, no cracking Termination Melting Point : 110-1250C Termination Hardness : 43-45 Shores D Cont. Operating Temperature : 400C -1250C Appropriate RoHS Standards Terminations dusty as; exclude track on shrink tube. It’s resistant moisture, humidity. Exclude air in critical areas, under control stress control, provide protection of cable insulation from environment, provide earth connection, prevent ingress of moisture, connect electrical equipment, and insulate exposed equipment. TEKNİK BİLGİLER TECHNICAL DATA SHEET APPLICATION Renewable cable joints are used for jointing power insulation connections, convenient for connection of underground, ground telecom and energy cables, insulation of electronic circuits, surface coating, Park and garden illumination, pool, any moisture ambient and under water. This material easily unfixand re intervention at the same cable joint. ProSil mold used stainless screws, so easily opens and closes. Plastic mold is resistant to physical impact. SUITABLE CABLE TYPES YVV-U,YVV-R, CU/PVC/PVC and NYY Use for, PVC insulations, HEPR, EPR,xLPE, other side, armour cables, mining, ship, airport lighting, railway, control, telephone, water pump, data and fiber cables. TECHNICAL DATA Insulation Resin has two components; Freezing point can change according to weather situation. Insoluble in water Viscosity : 4 Pa.s at 25 0 C Joint Hardness : 60 Shores A Tensile Strength : 0,85Mpa Elongation at Break : 30 %at 25 0 C Volume Resistivity : 1.7x1013 Ωcm Appropriate Voltage Range : 0.22-1kV Electrical Insulation : Up to 5kV Firing Point : Poliol Min. 250 0 C Freezing : Approx. at 0 0 C -10 0 C de 4min. 10 0 C -25 0 C de 30Min.25 0 C ve ↑ 15Min. Appropriate RoHS Standard UYGULAMA Yenilenebilir kablo ek mufu güç yalıtımlı bağlantılarda, yer altı, yer üstü telefon ve enerji kabloları bağlantısında, elektronik devre kaplamasında, yüzey kaplamada, park ve bahçe aydınlatmalarında, su havuzlarında, her türlü nemli ortamda ve su içerisinde kullanıma uygundur. Aynı kalıp içerisinde ProSil’in sökülerek, yapılan kablo ek’ini tekrardan müdahale etme imkânı sağlar. ProSil kalıbında paslanmaz vida kullanılmıştır, kolayca açılır ve kapanır. Plastik kalıp fiziksel darbelere dayanıklıdır. UYGUN KABLO TÜRLERİ YVV-U,YVV-R, CU/PVC/PVC ve NYY HEPR, PVC yalıtımlı, EPR vexLPE kablolar ile birlikte çelik zırhlı kablolar, telefon, su pompası kabloları için uygundur. TEKNİK BİLGİ Yalıtım sıvısı çift birleşenlidir. Donma süresi hava sıcaklığına göre değişkenlik gösterir. Su içinde çözünmez Viskozite : 25 0 C de 75 Pa.s Muf Sertlik : 50 Shore A Gerilim Dayanımı : 0,85Mpa Kopma anında uzama : 25 0 C de %30 Hacim Özdirenci : 1.7x1013 Ωcm Uygun Gerilim Aralığı : 0,22-1kV Elektriksel Yalıtkanlık : 5kV’a kadar Parlama Noktası : Poliol Min. 250 0 C Donma : 0 0 C -10 0 C de 45Dak. 10 0 C -25 0 C de 30Dak.25 0 C ve ↑ 15dak. RoHS standartlarına uygundur.

TEKNİK BİLGİLER - Tamer Elektrik€¦ · TEKNİK BİLGİLER TECHNICAL DATA SHEET APPLICATION Renewable cable joints are used for jointing power insulation connections, convenient

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TEKNİK BİLGİLER - Tamer Elektrik€¦ · TEKNİK BİLGİLER TECHNICAL DATA SHEET APPLICATION Renewable cable joints are used for jointing power insulation connections, convenient

26

APPLICATIONHeat shrinkable indoor termination are used for, energy cables, power house, electrical distribution points, any moisture ambient.During the mounting of heat shrinkable termination, do not apply the fire on the tube surface not fixed, must apply with circular movements.Indoor termination can apply for only in closed areas. Shed number is changes according to rated voltage and type of terminations.

SuItable Cable TypesUse for, PVC insulations, XLPE, armour cables, mining, airport lighting cables.

TechnIcal DataWater Absorption : ASTM D 570Low Temperature Flexibility : -400C/4 Hrs, no crackingTermination Melting Point : 110-1250CTermination Hardness : 43-45 Shores DCont. Operating Temperature : 400C -1250CAppropriate RoHS StandardsTerminations dusty as; exclude track on shrink tube. It’s resistant moisture, humidity. Exclude air in critical areas, under control stress control, provide protection of cable insulation from environment, provide earth connection,prevent ingress of moisture, connect electrical equipment,and insulate exposed equipment.

TEKNİK BİLGİLERTECHNICAL DATA SHEET

APPLICATIONRenewable cable joints are used for jointing power insulation connections, convenient for connection of underground, ground telecom and energy cables, insulation of electronic circuits, surface coating, Park and garden illumination, pool, any moisture ambient and under water.This material easily unfixand re intervention at the same cable joint. ProSil mold used stainless screws, so easily opens and closes. Plastic mold is resistant to physical impact.

SUITABLE CABLE TYPESYVV-U,YVV-R, CU/PVC/PVC and NYYUse for, PVC insulations, HEPR, EPR,xLPE, other side, armour cables, mining, ship, airport lighting, railway, control, telephone, water pump, data and fiber cables.

TECHNICAL DATAInsulation Resin has two components; Freezing point can change according to weather situation. Insoluble in waterViscosity : 4 Pa.s at 25 0C Joint Hardness : 60 Shores ATensile Strength : 0,85MpaElongation at Break : 30 %at 25 0CVolume Resistivity : 1.7x1013 ΩcmAppropriate Voltage Range : 0.22-1kVElectrical Insulation : Up to 5kVFiring Point : Poliol Min. 250 0CFreezing : Approx. at 0 0C -10 0C de 4min. 10 0C -25 0C de 30Min.25 0C ve ↑ 15Min. Appropriate RoHS Standard

UYGULAMAYenilenebilir kablo ek mufu güç yalıtımlı bağlantılarda, yer altı, yer üstü telefon ve enerji kabloları bağlantısında, elektronik devre kaplamasında, yüzey kaplamada, park ve bahçe aydınlatmalarında, su havuzlarında, her türlü nemli ortamda ve su içerisinde kullanıma uygundur.Aynı kalıp içerisinde ProSil’in sökülerek, yapılan kablo ek’ini tekrardan müdahale etme imkânı sağlar.ProSil kalıbında paslanmaz vida kullanılmıştır, kolayca açılır ve kapanır. Plastik kalıp fiziksel darbelere dayanıklıdır.

UYGUN KABLO TÜRLERİYVV-U,YVV-R, CU/PVC/PVC ve NYYHEPR, PVC yalıtımlı, EPR vexLPE kablolar ile birlikte çelik zırhlı kablolar, telefon, su pompası kabloları için uygundur.

TEKNİK BİLGİYalıtım sıvısı çift birleşenlidir. Donma süresi hava sıcaklığına göre değişkenlik gösterir. Su içinde çözünmezViskozite : 25 0C de 75 Pa.sMuf Sertlik : 50 Shore AGerilim Dayanımı : 0,85MpaKopma anında uzama : 25 0C de %30Hacim Özdirenci : 1.7x1013 ΩcmUygun Gerilim Aralığı : 0,22-1kVElektriksel Yalıtkanlık : 5kV’a kadarParlama Noktası : Poliol Min. 250 0CDonma : 0 0C -10 0C de 45Dak. 10 0C -25 0C de 30Dak.25 0C ve ↑ 15dak.RoHS standartlarına uygundur.