tekmarNet ® 2 Thermostat 528
Q 52808/10
Zoning Replaces: 10/0
Quick Setup Guide
1 2 3 4
tN2 Manager, Moduleor Wiring Center
tN2 tN2Slab Sensor 079, or
Outdoor Sensor 070, orIndoor Sensor 076, 077, 084
1 2 3 4
tNt 528 5 2 8
One Stage Heat
Made in
Canada
M m m
Y Y Y Y
L o t
# 1 2 3 4 5
M e e t s
C l a s s
B :
C a n a
d i a n
I C E S
F C C
P a r t
1 5
1 0 2 3
- 0 2
tN2
1
tN2
2
S w
i t c h S e t t i n g s :
For instructions see brochure
Use at least 65°C conductors
ON
Sensor
3 4
S e t b a c
k
S c e n e
N o n e
U n
l o c
k
L o c
k
C o o
l M e m
b e r
1
O ff
O ff
No Power
Location1. Remove Mounting Base2.
Install Mounting Base3. Wiring4.
Switch Settings5.Switch Position Action
1 ON
SETBACK Allow thermostat to respond to
available schedule. Requires Timer 033.OFF OFF No setback schedule response.
2ON
SCENE Allow thermostat to respond toscenes. Requires User Switch 479.
OFF OFF No scene response.
3ON
NONE The thermostat is not part of acooling group.
OFFCOOL MEMBER 1 The thermostat is amember of cooling group number 1.
4ON
LOCK Locked to ‘User’ access level. Setto Lock when installation completed.
OFFUNLOCK Unlock to access all settings.Set to Unlock during installation.
Close Thermostat6.
pivot
tab
ThermostatBase
AdaptorPlate 007
SwitchBox
OR
ThermostatBase
Wall
ExteriorWall
InteriorWall
5 feet1.5 m
Switch Setting Location
8/8/2019 Tekmar 528 One Stage Heat tN2 Thermostat
http://slidepdf.com/reader/full/tekmar-528-one-stage-heat-tn2-thermostat 2/2
Product design, software and literature are Copyright © 2010 by:tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 2 of 2 All specifications are subject to change without notice.Printed in Canada. Q 528 - 08/10.
tekmar Control Systems Ltd., Canada, tekmar Control Systems, Inc., U.S.A. Head Office: 5100 Silver Star Road,
Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com
User Interface7.
Critical Settings8.
For a full list of settings and operational details, please refer to the thermostat Installation and Operation Manual
(D528) included with compatible tekmarNet ® controls or download the brochure from www.tekmarcontrols.com
Display Range Access Description Set to
°F or °CDefault = °F
Installer
User
TEMPERATURE UNITS
Press the or the button to change from °F to°C and vice versa.
On or Off
Default = On Installer
ROOM SENSOR
Select whether the built-in air temperature sensor ison or off.Available when:A floor sensor or room sensor is installed on theauxiliary sensor input.
Off, Room,Outdoor,
Floor, FloordSP
Installer
AUXILIARY SENSOR
Select the type of auxiliary sensor.
Floor dSP = Show floor sensor reading in uppernumber field.
Available when:
Auxiliary sensor automatically detected.
OFF, dLy
(delay), OnDefault = On
Installer
HEATING SUPPLY PUMP
Select how the system supply pump should operate:On = system pump on during a call for heat.Delay = system pump delayed 3 minutes for thermalmotor (wax actuator) zone valves to open.Off = system pump not turned on during a call for heat.Use when a manifold uses a Zone Group Pump.Available when:
A reset control is present on the tekmarNet ® system.•
• Press and hold down both the and buttons for 2 seconds to change from one step to the next.
• Release both buttons once the step has been reached.• Press the or the button to change the setting, if available.
• Press and hold down both the and buttons for 2 seconds to go to the next step, OR• After 10 seconds of no button activity, the display goes back to normal operation.
Press
+
Together
The following settings are essential to the successful operation of the system.
ImportantNote: Set switch setting #4 and tekmarNet ® system control to Unlock to change Access level to Installer. Return to Locksetting once installation has been completed.