6
The TP8-28 and TP8-28 GSM systems implement the Tecnoalarm RSC technology right from the basic versions. The advantages and the performance offered by the RSC technology are now available to realize even small-sized installations with a high level of technology. Expandable serial alarm systems TP8-28 – TP8-28 GSM

Tecnoalarm Gsm Depl Tp8-28 Eng Lr

Embed Size (px)

Citation preview

Page 1: Tecnoalarm Gsm Depl Tp8-28 Eng Lr

The TP8-28 and TP8-28 GSM systems implement the

Tecnoalarm RSC technology right from the basic versions.

The advantages and the performance offered by the RSC

technology are now available to realize even small-sized

installations with a high level of technology.

Expandable serial alarm systems

TP8-28 – TP8-28 GSM

Page 2: Tecnoalarm Gsm Depl Tp8-28 Eng Lr

Zone

Configuration

System

Configuration

8

Programs

1 2 3 4 5Finger

100Acces Period

4

Key

100Yearly Calendar

2

Trasmitter

80Timer

6

Code

120

OPERATINGCODES

AUTOMATICFUNCTIONS

Wired

28

Wireless

28

Logic

Zones28

Tecnoalarm Technology

ZonesSystem configuration is entirely modular thanks to the input expansion modules.The 2 conventional and the 6 bus inputs of the CPU constitute the basic version ofthe system. They are expandable to a total of 28 zones which can be freely associatedto the hard-wired (conventional or bus) or wireless inputs of the connected hardware.The zone programming facilities allow to obtain excellent performances even fromtraditional detectors but the best results are obtained by using the Tecnoalarm RDVand RSC detectors. These detectors permit the verification and analysis of the alarmsat the very moment they are released, through the specific diagnostic tools of themonitoring software. In this way, the limitations of traditional remote managementhave been overcome and a new concept of interaction has been proposed.(RDV® and RSC® are registered trademarks and protected by international patents)

The Tecnoalarm systems which are equipped with the(Remote Sensitivity Control) technology communicate withthe monitoring station and transmit specific and detailedinformation. The Tecnoalarm monitoring station can programand constantly monitor the system from a distance and, usingsophisticated diagnostic tools, verify the smooth functioningand obtain the necessary information to maintain and improveits performance.

ProgrammingProgramming of the system’s functioning parameters can be madelocally or remotely, via telephone line, using the Tecnoalarm software.The software provides numerous programming tools which permitcustomization of the installation selecting the most appropriate amongthe options available.

Programs and control unitsThe TP8-28 and TP8-28 GSM systems manage 8 programs. A wide range of controlunits is able to satisfy any application requirements. The range comprises theLCD300/S console with voice synthesis, the new LCDPROX1 console with graphicdisplay and transponder reader, RFID card and finger print readers as well as theexclusive TSP7000 STD consoles with 7 inches touch screen and, for the STD-BIOversion, with biometric finger print reader. The users have access to the system’sfunctions through 120 codes, 100 transponders/RFID cards, 80 wireless keys and100 finger prints. Access to the protected areas can be automated and regulatedby 4 access periods and 6 timers.

Page 3: Tecnoalarm Gsm Depl Tp8-28 Eng Lr

TelephoneCommunication

Wireless

Controls

Remote

Advanced

Configuration

Data File

Events

Alarm

Photo

dBm level

RF Monitor

LowHigh

Bad

Timers

64

Actions

128

Phone Book

6

Counters

16

Synoptic

4

SMS DTMF

Lights Shutters

Roller

Irrigation

8 RemoteControl

VOICE RINGSMS DTMFFSK DATI

PSTNInterface

TP8-28 SYSTEMCOMMUNICATION

DEVICE

TP8-28 GSM SYSTEMCOMMUNICATION

DEVICE

156 PROTOCOLS

GSM-GPRSModule

Ethernet59 PROTOCOLS

GSM-GPRSModule

Ethernet

Event BufferCapacity

1500

Download SavePrint

Consoles

2Sirens

2Sensor

28

WIRELESSDEVICES

Event logThe event log contains all the events relating to the system’s functioning, i.e.the alarms, the diagnostics and the changes of status. A total of 1500 eventscan be recorded, in reverse chronological order, with indication of date and time. For each event, detailed information is given about the interested zones,programs and remote controls, identified by a number and a description,as well as the telephone calls. For each alarm detected by the RSC detectorsa graph showing the detector’s functioning at the moment of alarm releaseis also stored. The installer can download the event log at any time using theTecnoalarm software and extract the necessary information to verify thesystem’s smooth functioning.

Advanced programmingThe advanced programming tool is a software expansion of the programmingfacilities of the TP8-28 and TP8-28 GSM systems permitting a large extent ofcustomization extending the system’s resources and integrating homeautomation functions. It allows to offer functional solutions to particularapplication requirements making cost-expensive external devices redundantand implementing the PLC (programmable logic controller) programming logic.The conventional functionality of the inputs, outputs, channels, remote controlsetc. is redefined through a series of actions, associated to the events.The actions can be linked and scheduled by timers and counters.

Telephone sectionThe telephone section provides 8 telephone channels. The TP8-28 system uses thePSTN line and optionally the GSM or Ethernet network through respectively the externalGSM communicator TECNOCELL-PRO PL and the PROG NET2 Ethernet interface.The TP8-28 GSM system uses the GSM network through the integrated GSM/GPRSinterface or the external GSM communicator TECNOCELL PRO-PL and optionally theEthernet network through the PROG NET2 Ethernet interface. According to the system,TP8-28 or TP8-28 GSM and the vector, the telephone section uses several communicationformats: voice calls, SMS or data transmission in FSK, DTMF and TCP/IP formats.The alarm and system status messages are automatically composed by the systemusing the onboard vocabulary. The TP8-28 and TP8-28 GSM systems communicate withthe user and the central monitoring stations using respectively 156 and 59 communicationprotocols.

Wireless sectionThe expansion of the system is possible, even if cable laying is complicated,by the installation of maximum 2 wireless receivers or receiver-transmittersable to manage a total of 80 wireless keys, 28 wireless detectors as well as,respectively, 2 wireless consoles and sirens. The wireless communication,i.e. the transmissions of the alarm signal and the automatic test signal (supervision),is constantly verified and analyzed and the detected interferences, transformedinto a graph, can be consulted, locally or remotely, using the RF Monitor diagnostictool of the Tecnoalarm software. The wide range of Tecnoalarm wireless detectors,comprising indoor and outdoor detectors as well as perimeter protections, offersideal solutions for all protection requirements.

InteractionThe TP8-28 and TP8-28 GSM systems provide 8 remote controls whichallow the user to interact with the systems through telephone calls orSMS messages. The remote controls are customizable and permit the management of the system’s functions as well as the interaction with external devices such as heating, air-conditioning, lighting equipment etc.

Page 4: Tecnoalarm Gsm Depl Tp8-28 Eng Lr

SENSOR BUS

PROG USB PROG NET2 TSP LINK

ETHERNET

TSP7000 STD-BIOTSP7000 STD

SRA

SRINT

OUT2 OUT2

OUT1 OUT1 OUT1

SIREN BUS

SPEED ALM8 PLUS SPEED 8 PLUS SPEED 4 PLUS SPEED ALM8 PL

SAEL 2010 BUS

TP SDNTECNOCELL-PRO PL ESP32-OCNSINOTTICO 32N

+ SRA

- SIR

- OUT1

- OUT2

APR CARD APR FINGER APR FINGER-CARD

SRA

SRINT

OUT2

OUT1

OUT2

OUT1 OUT1

SPEED 8 SPEED 4 SPEED 8 STD

RX300/433868 RTX200/433868

SIREN BUS

LCD300/S LCDPROX1 SERIAL BUS

ESP4-20 TP PROX

Mar 10 GEN 12Feri. 13:46

4

8

3

7

2

6

1

5

6 DEVICES

2 DEVICES

8 DEVICES

2 DEVICES

1 DEVICE 12 DEVICES

TP8-28 – TP8-28 GSM SYSTEM CONFIGURATION

8 DEVICES

1 DEVICE

28 DEVICES

2 DEVICES

2 DEVICES

2 DEVICES

PROG INTERFACE

RSC DETECTORS

Page 5: Tecnoalarm Gsm Depl Tp8-28 Eng Lr

Mar 10 GEN 12Feri. 13:46

4

8

3

7

2

6

1

5

TP OUT6OCV+ -

SRE-

SRI- OUT

1 2 3 4

TP PROXLED V+L1 L2 L3 KR1L4 KR0

TP OUTRELC NO NC

TP BUSVOC+ - A B S

ESP BUSTP BUS+ - A B

SPEED ALM8 PLUS SPEED 8 PLUS SPEED 4 PLUS SPEED 8 SPEED 4

POWER SUPPLY 1.8A 1.8A

ZONES 8 BUS 8 BUS 4 + 4 BUS 8 8 4

OUTPUTS 4 2 1 4 2 1

CASING optional optional optional optional

CODE F101SPEALM8PLUS F101SPEED8PLUS F101SPEED4PLUS F101SPEEDALM8PL F101SPEED8 F101SPEED4

Input

expansions

TECHNICAL SPECIFICATIONS OF BUS EXPANSIONS

4 2 1

1 SIREN BUS

SPEED ALM8 PL

ESP32-OCN SINOTTICO 32N

OUTPUTS

32 programmable

LEDSIGNALING LED

CASING optional

32 programmable

open collectors

CODE F127ESP32OCN F127SINOTTICON

Output

expansions

TSP7000 STD TSP7000 STD-BIO

FINGER PRINTS

MEMORY local (100 finger prints)

CODES

PROGRAMS 8 8

VOICE SYNTHESIS

LCD 7” 65,000 colors – touch screen – 800x480dpi

ETHERNET PORT

USB PORT

RS422 SERIAL PORT

CODE F210TSP7000ST F210TSP7000STBI

Touch screen

consoles

LCD300/S LCDPROX1

CODES

TRANSPONDERS

PROGRAMS

DISPLAY

8 8

VOICE SYNTHESIS

SIGNALING LED

CODE

LCD

consoles

2x16 characters

36 23

F127LCD300S F127LCDPROX1

graphic

N.B. Connection with the control panel through TSP LINK

SAEL 2010 BUS SAEL 2010PRO BUS

PROGRAMS 1 to 8 1 to 8

ANTI-DRILLING

ALARM MODES 16 16

CASING ABS aluminum

ANTI-FOAM

CODE F105S2010BUSBI F105S2010PROBUS

Bus

sirens

SENSOR BUS

ZONE BUS

FINGER PRINTS

RFID CARDS

CODES

MEMORY local (100 finger prints) local (100 finger prints)

PROGRAMS 3 3 3 4

SIGNALING LED 4 4 4 7

Secondary

control

units

APR FINGER APR CARD TP SDNAPR FINGER-CARD

CODE F103APRFINGCARD F103APRFING F103APRCARD F127TPSDN

TP BUS TP BUSVOC

Additional

modules

COMPATIBILITY

FUNCTION

VOICE SYNTHESIS

For TP8-28 and TP8-28 EN only

CODE F127TPBUS F127TPBUSVOC

serial bus serial bus

ESP4-20

ZONES 4

CODE F127TP420ESP

Internal

input expansion

TP PROX TP OUT6OC

Additional

modules

COMPATIBILITY

FUNCTIONOutput expansion6 open collectors

Relay module1 relay

TP OUTREL

All versions

Technical specifications of internal expansions

RTX200/433868 RX300/433868

RECEIVER

RECEIVER-TRANSMITTER

RX FREQUENCY 433MHz/868MHz 433MHz/868MHz

TX FREQUENCY 868MHz

CODE F102RTX200 F102RX300

CASING

Wireless

expansions

SPEED 8 STD

8

optional

F101SPEED8STD

TECNOCELL-PRO PL

FUNCTION

PROTOCOLS

VOICE MESSAGES

BACKUP

SMS MESSAGES

CODE F104TECNOC/PPL

GSM

CODE F127TPPROX F127TPOUT6OC F127TPOUTREL

Transponderinterface

secondary/backup

ZONE BUS

Page 6: Tecnoalarm Gsm Depl Tp8-28 Eng Lr

Interface

PSTN Advanced

Configuration

Power

A V

Supply Box

ABS

Module

GSM

EN 50131-1EN 50131-3

Approval

ConnexionSerial BUS

Connexion

Serial BUS

VOC

c/Vapor 18 (Pol. Ind. El Regas)08850 Gavá - Barcelona (España)tel. [email protected] - www.tecnoalarm.es

495, Rue Antoine Pinay - 69740 Genas - Lyon (France)tél. +33478406525 - fax [email protected] - www.tecnoalarm.comAgence de Paris: 125, Rue Louis Roche - 92230 Gennevilliers

Via Ciriè, 38 - 10099 San Mauro T.se - Torino (Italy)tel. +390112235410 - fax [email protected]

11-2

011

Rev

. 0

CONTROL PANEL VERSIONS

For the itemnumbers please

contact thereseller

TP8-28

TP8-28 EN

TP8-28 GSM/V EN

TP8-28 GSM/V

2A

2A

2A

2A

All specifications listed in this brochure are subect to change without notice.

Optional

Optional

Optional

Optional

Grade 2

Grade 2

ZONES

SYSTEM

FEATURES

OUTPUTS

PROGRAMS

ACCESS

MANAGEMENT

AUTOMATION

TELEPHONE

SECTION

TP8-28

Total logic zones

CPU hard-wired zones

Total hard-wired zones

Total wireless zones

28

2 conventional + 6 bus

28

28

Actions

Timers

Counters

Telephone directory

Reserved output expansions

128

64

16

6

4

Operating voltage

CPU board consumption TP8-28

CPU board consumption TP8-28 GSM

Power supply

Battery

230V AC +/- 10% 50Hz

150mA @ 13.8V DC

220mA @ 13.8V DC

2A @ 14.8V DC

12V/7Ah

Casing

Dimensions (L x H x D)

Weight (without battery)

ABS

350 x 285 x 93mm

TP8-28 (2.7kg) - TP8-28 GSM (2.8kg)

CPU outputs

Logic siren outputs

2 + 2 programmable

4

RS485 serial bus

Voice synthesis

Event buffer capacity

Printer management

According to version

According to version

1500

Programs

Access codes

Finger prints

Transponders/RFID

Wireless keys

8

120

100

100

80

Timers

Access periods

Calendar years

Remote controls

Test call

Server test call

6

4

2

8

Hard-wired input expansions

Wireless expansions

Consoles

Secondary control units

Output expansions

GSM telephone communicator

Bus sirens

Wireless sirens

Wireless consoles

2

2

8

8

12

1

2

2

2

ADVANCED

PROGRAMMING

ELECTRICAL

SPECIFICATIONS

PHYSICAL

SPECIFICATIONS

Channels

Primary vector

Secondary vector (optional)

Secondary vector (optional)

Transmittable events

Telephone number length

Call event queue

Communication protocols

8

PSTN

External GSM

Ethernet

128

24 digits

32

156

SERIAL BUS

EXPANSIONS

TECHNICAL AND FUNCTIONAL SPECIFICATIONS

TELEPHONE

SECTION

TP8-28 GSM

Channels

Primary vector

Secondary vector (optional)

Secondary vector (optional)

Transmittable events

Telephone number length

Call event queue

Communication protocols

8

GSM

External GSM

Ethernet

128

24 digits

32

59

Optional

Optional

Optional