TechPatient CARDIO V3 Brochure

Embed Size (px)

Citation preview

  • 8/2/2019 TechPatient CARDIO V3 Brochure

    1/4

    instruments

    WaveformECG, Sine,Triangular, Square,Pulsed and Baseline

    Ritmic*,

    Beat Rate20 BPM to 300 BPM0% to 20%* deviation

    Frequency 1/8Hz to 120Hz

    Noise SourcesLine, Ripple, Random,Baseline W., Tremor

    Amplitude0.5mV, 1mV, 2mV, 4mV0% to 20%* deviation

    Leads 12 (Snap / Banana / Pin)

    Power Source Standard 9V Battery or 9VDC Adapter(NOT INCLUDED)

    Product Size

    Approx. Weight

    150mm x 90mm x 26mm

    400gr

    Hi-Signal Output 200x Lead II plus DC

    Output Impedance 2200 unipolar

    http://www.heinstruments.com/ [email protected]

    Technical

    Specifications

    Cardiac Simulation

    Advanced Analysis

    instrumentsinstruments

    MODULEArrhythmias Simulation

    Calibration

    CertificateTraceability & Conformity

    The stands among itscompetitors for generating realistic cardiac waveforms, anadvantage that gives you the certainty that any test conductedwith this simulator will be repeatable with a human patient.

    Twelve leads ECG simulation is suitable to test moderndiagnostic equipment, including waveform recognition devices.

    Using the EKG simulator you will also beable to test the noise filtering systems and beat rate measurementfunctions of the diagnostic device under test.

    To perform noise testing, multiple real life noise sources areincluded. You can select between line noise (related to poorground connections), base line wandering (related to poorelectrode conductivity), muscle tremor, power supply noise and

    more.The beat rate setup function combines the selection of an

    arbitrary rate with the addition of beat to beat variability, a keyperformance testing to make sure diagnostic devices operateproperly under critical conditions.

    TechPatient CARDIO

    TechPatientCARDIO

    ECG simulator

    mailto:[email protected]?subject=Additional%20Rhythms%20for%20Ritmic%20Module%20Quotationmailto:[email protected]:[email protected]:[email protected]?subject=Additional%20Rhythms%20for%20Ritmic%20Module%20Quotation
  • 8/2/2019 TechPatient CARDIO V3 Brochure

    2/4

    Retail box for global market

    The new retail product box enables our

    customers to resell the simulator in the US

    and other global markets. It includes the UPC

    product barcode, FCC exempt ion

    declaration and an eye-catching graphicdesign that will help you boost your sales.

    Neoprene travel holster

    The new Neoprene travel holster protects the

    simulators from shocks and moisture while

    easing its transport. Its flexible structure

    helps you carry cables or even a spare

    battery.Attach it to your belt to have your simulator at

    hand every time you need it.

    Biopotential multi-connectors

    The new multi-connectors give the simulator

    enhanced compatibility, enabling its

    connection to 4mm snap, 4mm banana and

    2mm pin patient cables. Youll no longer needexpensive adapters that degrade reliability

    and performance.

    FeaturesinTechPatientCARDIOV

    ersion3

    instrumentsinstrumentsinstruments

    http://www.heinstruments.com/ [email protected] +1-866-921-4971http://www.heinstruments.com/ [email protected] +1-866-921-4971

    http://www.heinstruments.com/mailto:[email protected]://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/mailto:[email protected]://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmmailto:[email protected]://www.heinstruments.com/mailto:[email protected]:[email protected]://www.heinstruments.com/
  • 8/2/2019 TechPatient CARDIO V3 Brochure

    3/4

    instrumentsinstrumentsinstruments

    MODULE

    [email protected]

    Arrhythmias Simulation Module

    The Ritmic MODULE is an arrhythmias simulation sofware moduleinstalled on demand to the TechPatient CARDIO V3 ECGsimulator. The following is a list of the simulated rhythms.Additional rhythms can also be included. Please contact us at

    for specific [email protected] Sinus RhythmwSinus BradycardiawSinus TachycardiawSinus Respiratory ArrhythmiawSinus Exit BlockwSinus Arrestw1st Degree AV Blockw2nd Degree Type I Av Blockw2nd Degree Type II Av Blockw2nd Degree 2:1 Av Blockw3rd Degree Av Block

    wLeft Bundle Branch BlockwRight Bundle Branch BlockwSinus Rhythm with PACwSinus Rhythm with PNC / PJCwSinus Rhythm with PVCwSupraventricular TachycardiawAtrial FlutterwAtrial FibrillationwAtrial BigeminywAtrial TrigeminywNodal (Junctional) RhythmwAccelerated Nodal (Junctional) Rhythm

    wNodal (Junctional) TachycardiawNodal (Junctional) BigeminywNodal (Junctional) TrigeminywIdioventricular RhythmwAccelerated Idioventricular RhythmwMonomorphic Ventricular TachycardiawTorsades de PointeswVentricular FibrillationwVentricular BigeminywVentricular TrigeminywWolf-Parkinson-White Syndrome

    wNormal Pediatric ECGwLong QT Segment SyndromewST Segment ElevationwST Segment DepressionwPacemaker Rhythm - Atrial PacedwPacemaker Rhythm - Ventricular PacedwPacemaker Rhythm - AV SequentialwPacemaker Not CapturedwPacemaker Not FunctioningwPacemaker On DemandwAsystole

    Click toPlay Video

    Automatic Sequencing

    Automatic sequencing is specially useful for product show off on

    trade fairs and events. Random sequencing has also been

    included for medical educators and paramedic instructors to train

    and challenge their students to recognize the simulated

    arrhythmia. The simulated rhythm strip changes every 10 seconds

    with a 1 second flatline pause in between.

    http://www.heinstruments.com/ [email protected] +1-866-921-4971http://www.heinstruments.com/ [email protected] +1-866-921-4971

    http://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmmailto:[email protected]?subject=Additional%20Rhythms%20for%20Ritmic%20Module%20Quotationhttp://www.heinstruments.com/mailto:[email protected]://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/mailto:[email protected]://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmmailto:[email protected]://www.heinstruments.com/mailto:[email protected]:[email protected]://www.heinstruments.com/mailto:[email protected]?subject=Additional%20Rhythms%20for%20Ritmic%20Module%20Quotation
  • 8/2/2019 TechPatient CARDIO V3 Brochure

    4/4

    Mode

    Base

    Calibration CertificateThe calibration of our devices includes:

    Declaration of results traceability to national standards.

    Declaration of conformity to manufacturing specifications.

    Test results with their respective associated uncertainties.

    Calibration Certificate Sample

    Specific Calibration Procedure SP01EN

    Factory Calibration CertificateThe additional cost for the purchase of a TechPatient CARDIO V3with the calibration certificate is US$ 35.-.

    To purchase the cert i f icate please contact us at

    before purchasing the product. You

    can also add it to your shopping cart before checking out. Requests

    received after product purchase will be accepted or rejected at HE

    Instruments option based on the status of the order.

    [email protected]@heinstruments.com

    Traceability to National Standards

    The measurement instruments used for device calibrationare traceable to national standards. The time standard has

    been calibrated by a NIST traceable laboratory, while the

    voltage standard has been calibrated by an OAA / INTI

    SAC accredited laboratory. The calibration certificates of

    this time and voltage standards are available to our

    customers upon request to [email protected].

    http://www.heinstruments.com/ [email protected] +1-866-921-4971http://www.heinstruments.com/ [email protected] +1-866-921-4971

    http://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/files/TPCardio_calibration_sample.pdfhttp://www.heinstruments.com/files/calibration_procedure_SP01EN.pdfmailto:[email protected]?subject=Calibration%20Certificate%20TechPatient%20CARDIOmailto:[email protected]?subject=Calibration%20Certificate%20TechPatient%20CARDIOmailto:[email protected]?subject=Traceabilityhttp://www.heinstruments.com/mailto:[email protected]://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/mailto:[email protected]://www.heinstruments.com/contact.htmhttp://www.heinstruments.com/contact.htmmailto:[email protected]://www.heinstruments.com/mailto:[email protected]:[email protected]://www.heinstruments.com/mailto:[email protected]?subject=Traceabilitymailto:[email protected]?subject=Calibration%20Certificate%20TechPatient%20CARDIOhttp://www.heinstruments.com/files/calibration_procedure_SP01EN.pdfhttp://www.heinstruments.com/files/TPCardio_calibration_sample.pdf