18
Technology Solutions 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 www.tek-trol.com Flow | Level | Temperature | Pressure | Valves | Analyzers | Accessories | TekValSys

Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

  • Upload
    others

  • View
    21

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

Technology Solutions

796 Tek DriveCrystal Lake, IL 60014 USA

Tel: +1 847 857 6076, +1 847 655 7428Fax: +1 847 655 6147

www.tek-trol.com

Flow | Level | Temperature | Pressure | Valves | Analyzers | Accessories | TekValSys

Page 2: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

State-of-the-art measurement solutions

We offer multiple flow measurement technologies to measure liquids, gas-

es, steam and corrosive fluidOur specialized level measurement

instruments consists of contact, non-contact, differential, and

ultrasonic, to cater to all types of varied process needs

Our field and panel mount designsoffer an array of technologies to

choose from

Flow Measurement

Level Measurement

Temperature Measurement

Pressure Measurement

AccessoriesTekValSys

02 03

Our pressure measurement ranges provide compelling

accuracy and reliability

To improve the efficiency and

durability of a product additional accessories

are always of great importance

Diagnostic systems that provide real time validation and

monitoring

A full line of digital panel meters,

indicators and control instrumentation for

process indication and control

Flow Measurement

Level Measurement

Temperature Measurement

Pressure Measurement

AccessoriesTekValSys

INDICATOR CONTROLLER

TEKVALSYSACCESSORIESPRESSUREMEASUREMENT

Page 3: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

Technology Solutions For Process Measurement Automation & Control

04 05

Page 4: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

Flow Measurement

Tek-Trol’s range of flowmeter monitors mass and volumetric flow of liquids, gases and steam with

premium accuracy, high stability and robust operation

06

Coriolis Mass Flowmeter - Tek-Cor 1100A

Electromagnetic Flowmeter - Tek-Flux 1400A

Service Liquids and Gas

Wetted Material 304 SS, 316 SS or Hastealloy CAccuracy 0.1% or 0.2% or 0.5%Ranges For mass flow rates please refer the catalogRepeatability For 0.1% accuracy: ±0.05%, For 0.2% OutputDigital Communication

4 to 20 mA PulseRS 485 or HART

Temperature Limit Direct Mount: -58°F to 257°F (-50°C to 125°C)Remote Mount: -58°F to 392°F (-50°C to 200°C)

Power Requirements 18 to 28 VDC or 85 to 220 VACProcess Connections Flanges, Tri-Clamp or Threads, DIN or ANSIResolution/ Display OLED DisplayPressure Limits See ManualEnclosure Ratings NEMA 4 x (IP67), 7, 9Agency Approval UL ClassⅠ, DivⅠWeight See Manual

Service Compatible conductive liquids

Wetted Material Electrode Material: 316 SS or Hastealloy CLiner Materials: PTFE or Hard Rubber

Accuracy ±0.5% of F. S.Ranges For flow range please refer the catalogRepeatability 0.15% and PulseOutput 4 to 20 mA; optional HART, Pulse or RS 485Temperature Limit Sensor (Remote Mount): -50°F to 158°F (-45°C to 70°C)

Converter: -40°F to 122°F (-40°C to 50°C)Direct Mount: 40°F to 122°F (-40°C to 50°C)

Power Requirements 18 to 28 VDC or 85 to 220 VACProcess Connections 150# to 900# ANSIResolution/ Display LCD displayPressure Limits ≤ 150 PSIEnclosure Ratings IP68Weight See ManualAgency Approval CE

07

Page 5: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

08

Vortex Flowmeter - Tek-Vor 1300C

Thermal Mass Flowmeter - Tek-Thermal 1700B

Service Air and NitrogenWetted Material 316 SS

Accuracy ±0.5% of FSFlow Velocity Ranges See Velocity ranges in CatalogRepeatability 0.2%

Output 4 to 20 mA with Pulsed output; Optional HART or RS 485Temperature Limit -40°F to 302°F (-40°C to 150°C)Power Requirements 13.5 VDC to 42 VDC

Process Connections 1/2" NPT

Resolution/ Display 5 Digit Display

Pressure Limits 232 PSI (16 bar)Enclosure Ratings IP65Weight See Manual

09

Ultrasonic Clamp-On Flowmeter - Tek-Clamp 1200A

Service Liquids, Gas, and Steam

Wetted Material 304 SS and 316 SS

Accuracy ±1% of reading

Ranges Gas: 197 ft/s (60 m/s)

Liquid: 23 ft/s (7 m/s)

Steam: 230 ft/s (70 m/s)

Repeatability 0.3% of reading

Output 4 to 20 mA and Pulse; Optional HART or

Modbus RS 485

Temperature Limit Standard: 302°F (150°C)

Medium: 482°F (250°C)

High: 662°F (350°C)

Power Requirements 13.5 to 42 VDC

Process Connections Wafer or ANSI Flange

Resolution/ Display LED

Pressure Limits See Flange Rating

Enclosure Ratings NEMA 4 x (IP67)

Agency Approval CE

Weight See Manual

Service Compatible Liquids

Wetted Material Sensor: Aluminum alloy or Plastic alloy

Accuracy 1%

Ranges 1200A-S2: ½" to 4", 1200A-M2: 2" to 28",

1200A-HS: ½" to 4", 1200A-HM: 2" to 28"

Repeatability 0.2%

Output 1200A-100F1: RS 485, 4 to 20mA and

frequency output

1200A-100M: RS 485, 4 to 20 mA and

frequency output

1200A-100H: RS 232

Temperature Limit 32°F to 320°F (0°C to 160°C)

Power Requirements 1200A-100F1: 85 to 264 VAC or 24 VDC,

1200A-100M: 8 to 36 VDC

1200A-100H: 90 to 230 VAC or Ni-MH battery

Process Connections ANSI 150#, 300#, 600#, 900# or AWWA Flanges

Resolution/ Display 1200A-100F1: 2” H x 20” W, 2 line x 20 characters

1200A-100M: 2” H x 20” W, 2 line x 20 characters

1200A-100H: 4” H x 16” W, 4 line x 16 characters

Pressure Limits As per flange rating

Enclosure Ratings 1200A-100F1: IP65, 1200A-100M: IP57

1200A-100H: IP65

Weight See Manual

Page 6: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

11

Indicator Controller

A full line of digital panel meters, indicators and control instrumentation for process indication and control

Loop-Powered Indicators- Tek-Lcd 7800A Series

Display Feet & Inches display: 0.60” (0.04ft) high, 0 to 699 FT – 11 15/16 IN with 1/16 or 1/8 fraction display

Display Update Rate Ambient > -13°F: 2 Updates/Second Ambient < -13°F: 1 Update/5 Seconds

Over Range Level display flashes to 699 FT 11 15/16 IN Volume display flashes 9999999 if over range

Under Range Display flashes -999999Recalibration Recommended at least every 12 months.Normal Mode Rejection

64 dB at 50/60 Hz

Operating Temperature Range

-40 °F to 167 °F

Storage Temperature -40 °F to 167 °FRelative Humidity 0 to 90% non-condensingConnections Screw terminals accept 12 to 22 AWG wireWeight 5.00 lbs (80 oz, 2.27 kg)

10

Venturi Tubes - Tek-DP 1640A

Orifice meters - Tek-DP 1610A

Cone Flowmeter - Tek-DP 1620A

Flow nozzles - Tek-DP 1630A

Service Liquids and Gas

Wetted Material 304 SS, 316 SS, 316 SS as standard. Monel, PP, PVC, PTFE coated

Temperature Limit Standard -20 °F to 100 °F (-28 °C to 37 °C), optional -40 °F to 1200 °F (-40 °C to 648 °C)

Weight See Manual

Service Liquids and Gas

Wetted Material 304 SS, 316 SS, 316 SS as standard. Hastelloy-C, Weight See Manual

Service Liquids and Gas

Wetted Material Carbon steel for weld in type, 304 SS, 304 SS, 316 SS, 316 SS for holding ring type and Ni, Cr, Mo Alloy Steel for flanged type

Weight See Manual

Service Liquids and Gas

Wetted Material All standard materials availableWeight See Manual

Page 7: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

12 13

Analog Input Batch Controller - TEK-BATCH 7900A

Display Upper display: 0.60" (0.04ft) high. Lower display: 0.46" (0.03ft) high. Both are 6 digits (-99999 to 999999), red LEDs.

Display Update Rate 5/second (200 ms)Over Range Display flashes 999999Under Range Display flashes -99999Recalibration Recommended at least every 12 months.Normal Mode Rejection

Greater than 60 dB at 50/60 Hz (PD8-6210)Isolation: 4 kV input/output-to-power line.500 V input-to-output or output-to-P+ supply.

Operating Temperature Range

T6 Class: -40 °F to 140 °FT6 Class: -40 °F to 65 °F

Storage Temperature -40 °F to 167 °FRelative Humidity 0 to 90% non-condensingConnections Screw terminals accept 12 to 22 AWG wireWeight 16.0 lbs (7.26 kg)

Page 8: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

Explosion-Proof Loop-Powered Indicators- Tek-Lcd 7800B

Display Five digits (-9999 to 99999) 0.70” (0.05ft) high, 7-segment, automatic lead zero blanking

Display Update Rate Ambient > -13°F: 2 Updates/Second.Ambient < -13°F: 1 Update/5 Seconds

Over Range Display flashes 999999Under Range Display flashes -99999Recalibration Recommended at least every 12 months.Normal Mode Rejection 64 dB at 50/60 Hz

Operating Temperature Range -40 °F to 167 °F

Storage Temperature -40 °F to 167 °F

Relative Humidity 0 to 90% non-condensingConnections Screw terminals accept 12 to 22 AWG wireWeightAgency Approval

5.00 lbs (80 oz, 2.27 kg) FM, CSA, ATEX, CE

14 15

Page 9: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

Large Display Batcher- Tek-Batch 7900B

SERIES NEMA 4X FLOW COMPUTER- TEK-FC 8000B

Operating Temperature -4 °F to 131 °F

Storage Temperature -40 °F to 185 °F Humidity 0-95% Non-condensingMaterials UL, CSA, VDE approvedKeypad Keypad Type: Membrane Keypad with 116

keys, Keypad Rating: Sealed to NEMA 4X / IP65Accuracy 0.02% FS at -4 °FRanges Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC

Current: 4-20 mA, 0-20 mA, 4-20 mA stacked, Basic Material Resolution 16 bit

Update 4 updates/sec Automatic Fault Detection Signal over/under-range, Current Loop Broken

Calibration Operator assisted learn modeExtended Calibration Learns Zero and Full Scale of each rangeReal Time Clock The Flow Computer is equipped with a non-volatile

real time clock with display of time and date.Format: 24 hour format for time Day, Month, Year for date

Operating Temperature 32 °F to 122 °F

Storage Temperature -40 °F to 185 °F Humidity 0-95% Non-condensingMaterials Plastic, UL94V-0, Flame retardant Bezel: Textured

per matt finishKeypad Keypad Type: Membrane Keypad with 16 keysAccuracy 0.02% FS at -4 °FRanges Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC

Current: 4-20 mA, 0-20 mA, 4-20 mA Basic Measurement Resolution 16 bit

Update 4 updates/sec Automatic Fault Detection Signal over/under-range, Current Loop Broken

Calibration Software Calibration (no trimmers) Extended Calibration Learns Zero and Full Scale of each range using special

test modeReal Time Clock The Tek-Batch is equipped with a battery backed

real time clock with display of time and date.Format: 12 or 24 hour time display; Day, Month, Year, date display

1716

Page 10: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

19

Level Measurement

Tek-Trol’s level measurement devices offers the right solution for your level measuring

requirements

Explosion Proof Guided Wave Radar Transmitter - Tek-Flex 4100A

18

Accessories

Tek-Trol provides wide range of instrumentation accessories, products and configurations for

optimum efficiency and durability for all industrial applications

Manifold Valve - Tek-Manifold 7500A

Service Compatible liquids, gases, or steam

Wetted Material Body, stem, valve assembly: SS 316; Stem packing: PTFE

Temperature Limit 450°F (232°C) Pressure Limits 6000 PSI (400 bar)

Service Water/Wastewater Industry and Chemical Industry

Wetted Material 316 SS, PTFERanges up to 10’ with minimum dielectric constant of 0.3Accuracy ± 0.039” ( 0.003ft) or 0.02% of measured distance,

whichever is greatestRepeatability ±0.02” (0.001ft)Resolution 0.0008”Temperature Limit Electronics: -40 ºF to 158 ºF (-40 °C to 70 ºC)

Pressure LimitsProcess/Probe: -40 ºF to 398 ºF (-40 °C to 203 ºC)-14.50 PSI to 580 PSI

Power Requirements 24 VDC <3WOutput Signal 4 mA to 20 mAProcess Connection ¾” NPTEnclosure Rating NEMA 6Mounting Orientation Vertical Failsafe

Agency Approvals

User selectable to 3.8 mA, 4 mA, 20 mA, 20.2 mAor last signalExplosion Proof

Page 11: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

20 21

Two Wire TDR Level Transmitter with HART - TEK-FLEX 4100C

2-Wire Loop Powered TDR Level Meter - Tek-Flex 4100B

Service Liquids

Wetted Material 316 SS, PTFE Accuracy ±0.039” ( 0.003ft) or 0.02% of measured distance,

whichever is greatest Ranges Up to 60’ Repeatability ±0.02” (0.001ft) Output 4 - 20 mATemperature Limit Electronics: -40°F to 158°F (-40°C to 70°C)

Process/Probe: -40°F to 398°F (-40°C to 203°C) Power Requirements 12 to 28 VDC (2-Wire)Process Connections ¾” NPT Resolution/ Display 5 DigitsPressure Limits -14.50 PSI to 580 PSI (-1 bar to 40 bar)Enclosure Ratings NEMA 6 Weight 2 lbs. (without probe)

Service Liquids and Bulk Solids

Wetted Material 316 SS, PTFE Accuracy ±0.4" (0.03ft)Ranges Up to 10' with minimum dielectric constant of 0.3 Repeatability ±0.02" (0.001ft) Output 4 to 20 mA/HARTTemperature Limit Electronics: -40 °F to 158 °F (-40 °C to 70 °C)

Process/Probe: -40 °F to 398 °F (-40 °C to 203 °C) Power Requirements 16 to 36 VDC (2-wire)Process Connections 1 ½" NPT Resolution/ Display 5 DigitsPressure Limits -14.50 PSI to 580 PSI (-1 bar to 40 bar)Enclosure Ratings NEMA 4XWeight 2 lbs. (without probe)

Ultrasonic Level Transmitter - Tek-Sound 4200A

Service Liquids and Bulk Solids

Wetted Material PVC Accuracy ±0.25% of max range Ranges 106” (9’), 193” (16’), 240” (20’), 358”(30’), 598”(50’),

717” (60’) Repeatability 0.08”Output 4 to 20 mA as Standard or Optional RS 232 or RS 485 or

750 Ω on 4 Wire Temperature Limit Electronic Enclosure: -40°F to 140°F (-40°C to 60°C);

Temperature Compensation: -40°F to 140°F (-40°C to 60°C)Power Requirements 4 Wire: 115 VAC at 60 Hz or 230 VAC at 50Hz

3 Wire: 12 VDC to 30 VDC Process Connections 1" NPT or 3" NPT Resolution/ Display 3 Digits Pressure Limits Up to 72 PSI (5 bar) Enclosure Ratings NEMA 6 (IP68) Weight 4.0 lb (1.8 kg)Agency Approval CE

Page 12: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

22 23

Differential Pressure Level Transmitter - Tek-Hydro 4500A-D

Service Compatible Liquids

Wetted Material Hastelloy C, 316 SS Accuracy ±0.075% of span Ranges 1.5 in H₂O to 1450 PSI (0.0037 bar to 100 bar)Output 4 to 20 mA with HART Temperature Limit Process temperature: -40°F to 248°F (-40°C to 120°C)

Operating temperature: -40°F to 185°F (-40°C to 85°C)Power Requirements 12 to 45 VDC Process Connections Diaphragm SealResolution/ Display 6 Digit DisplayEnclosure Ratings IP67 (NEMA 4X)Agency Approval FM/FMC, KOSHA KTL, ATEX

Two Wire Ultrasonic Level Transmitter - TEK-Sound 4200B

Service Liquids

Wetted MaterialEnclosure

Transducer: PTFEPowered Coated Aluminum

Weight 2 lbs.Accuracy 0.5%Ranges 13ft to 25ftRepeatability .08”Output 4 to 20 mA/HARTTemperature Limit -40°F to 248°F (-40 °C to 70 °C) Power Requirements 16 to 36 VDC (2-Wire)Process Connections 1½" NPTResolution/ Display 5 Digit DisplayPressure Limits -0.02 to 0.1Enclosure Ratings IP67 Beam Angle 5.5° From CenterWeight 2 lbs.

Radar Level Transmitter - Tek-Wave 4300A

Service Liquids and Bulk Solids

Wetted Material Antenna: Polypropylene (PP)Enclosure AluminumAccuracy ±0.25% of max range Ranges 201” (17ft), 393” (33ft), 590” (50ft), 1197” (100ft) Repeatability 0.08”Output 4 to 20 mA HARTTemperature Limit -40°F to 140°F (-40°C to 60°C) Power Requirements 12 to 30 VDC (2 Wire)Process Connections 1½" NPT or 2" NPT Resolution/ Display No DisplayPressure Limits Up to 72 PSI (5 bar) Enclosure Ratings NEMA 6 (IP68) Weight 6 Lbs.Agency Approval FM

Page 13: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

24 25

Hydrostatic Level Transmitters - Tek-Hydro 4500A-G

Service Compatible Liquids

Wetted Material Hastelloy C, 316 SS Accuracy ±0.075% of span Ranges 0.21 PSI to 8700 PSI (0.015 bar to 600 bar)Output 4 to 20 mA HART Temperature Limit Process temperature: -40°F to 248°F (-40°C to 120°C)

Operating temperature: -40°F to 185°F (-40°C to 85°C)Power Requirements 12 to 45 VDC Process Connections Diaphragm SealResolution/ Display LCD displayEnclosure Ratings IP67 (NEMA 4X)Agency Approval FM/FMC, KOSHA KTL, ATEX

Service Compatible Liquids

Wetted Material Body 304 SS, 316 SS Cable: PTFE or PolyurethaneAccuracy ±0.5% FSRanges 5 psig to 20 psig (3.5 mH2O to 14 mH2O),

Optional ranges availableOutput 4-20 mA, RS-485, 0.5-4.5 VDCPower Requirements 12 to 36 VDCTemperature Limit -40 °F to 257 °F (-40 °C to 125 °C)Pressure Limits 150% of spanEnclosure Ratings IP68Weight 0.9 lbs (408 g)

Submersible Level Transmitter - Tek-Sub 4800B

PTFE Submersible Level Transmitter - Tek-Sub 4800A

Service Compatible Liquids

Wetted Material Body: PTFE, O-Ring: FKM fluorine rubber Diaphragm: Ceramic (Al₂O₃, 96%)Cable: PTFE or Polyurethane

Accuracy ±0.5% FS Ranges 2.8 psig to 15 psig (2 mH2O to 10.5 mH2O)

Optional ranges availablePressure Limits 150% of spanOutput 4 to 20 mA RS 485 or 0.5 to 4.5 VDC Temperature Limit -20°F to 160°F (-29°C to 71°C) Pressure Limits 150% of spanEnclosure Ratings IP68Weight 0.9 lb (415 g)

Page 14: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

26

Wastewater Submersible Level Transmitter - Tek-Sub 4800D

Service Compatible Liquids

Wetted Material 304 SS, 316 SSAccuracy 0.25% FSRanges 10 psig to 50 psig (7 mH2O to 35 mH2O),

Optional ranges availableOutput 4-20 mA, RS-485, 0.5-4.5 VDC Temperature Limit -40 °F to 257 °F (-40 °C to 125 °C)Power Requirements 12 to 36 VDCPressure Limits 150% of SpanEnclosure Ratings IP68Weight 0.49 lb (225 g)

Service Compatible Liquids

Wetted Material 304 SSAccuracy ±0.5% FSRanges 5 psig to 20 psig (3.5 mH₂O to 14 mH₂O),

Optional ranges availableOutput 4-20 mA, RS-485, 0.5-4.5 VDCTemperature Limit -40 °F to 257 °F (-40 °C to 125 °C)Power Requirements 12 to 36 VDC Pressure Limits 150% of SpanEnclosure Ratings IP68Weight 8.8 lb (4000g)

0.062 ft Submersible Level Transmitter- Tek-Sub 4800C

27

Validation System

Diagnostic systems that provide real-time validation and monitoring

TekValSys DP

• Reduced Financial Exposure to Mismeasurement• Reduced Maintenance Cost• Reduced Risk to Personnel Health and Safety• Assurance of Meter System Performance• Possibility of Achieving Financial Payback in Few Days

This patented technique has proven to be an extremely powerful tool in ensuring accuracy, providing real-time alerts of meter mismeasurement, and performance shifts, and reducing maintenance overheads on DP systems. Applicable to all types of differential pressure metering systems, including Orifice, Venturi, Cone, Flow Nozzle, and Wedge; TekValSys DP uses 3 Differential Pressure (DP) measurements to monitor the entire pressure field through the meter body.

Page 15: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

28 29

TekValSys GC

• Provides real time assurance that the GC is operating correctly• Analyzes historical data to identify changes and predict future failures• Reduces the need for conventional maintenance and unnecessary costs• Determines dynamic GC uncertainty for quantification of GC performance• Validates that the pressure let down system provides a representative sample• Creates a fully auditable database of GC performance• Helps to support and increase a technician's competence level

A unique and comprehensive Condition-Based validation software package for Gas Chromatographs (GCs), comprising GCAS software and Panel PC for hazardous or safe areas.As an automated, condition-based monitoring software, TekValSys GC:

Page 16: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

3130

Temperature Measurement

Tek-Trol’s Temperature measurement devices provides accurate measurement of temperature even in the most

challenging conditions

Explosion-Proof Temperature Transmitter - Tek-Temp 2100A

Service Liquids and Gases

Wetted Material See Model ChartWeight 2.4 lb (1.2 kg) Accuracy ±0.003% of span Ranges As per sensor, refer the catalog for details Repeatability ±0.1% typicalOutput 4 to 20 mATemperature Limit Without condensing: -40°F to 185°F (-40°C to 85°C)

With LCD module: -22°F to 176°F (-30°C to 80°C) Power Requirements 10 to 45 VDCProcess Connections See Model Chart Resolution/ Display Optional 5 digit LCD displayEnclosure Ratings FM for Class I, Division 1Agency Approval CE, FM

Pressure Measurement

Our high-quality pressure measuring devices provides stable, reliable and accurate measurements

inprocess industries that requires high-precision measurement solutions

Explosion-Proof Differential Pressure Transmitter - Tek-Bar 3110A

Service Compatible gases, steam, liquids Wetted Materials 316 SSAccuracy 0.075% of URL Range Ability 100:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ¼" female NPT Display Optional 5 digit LCD Weight 8.8 lb (4.0 kg) Enclosure Rating NEMA 4 x (IP66)Agency Approval CE, FM (ClassⅠ, DivⅠ )

Page 17: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

32 33

Smart Gauge Pressure Transmitter - Tek-Bar 3120B

Service Compatible gases, steam, liquids Wetted Materials Hastelloy C, 316 SSAccuracy 0.075% of URL Range Ability 40:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ½" male NPT Display Optional 5 digit LCD Weight 3.43 lb (1.56 kg) Enclosure Rating NEMA 4 x (IP66)

Tri-Clamp Gauge Pressure Transmitter - Tek-Bar 3120C

Service Compatible gases, steam, liquids Wetted Materials 316 SSAccuracy ±0.2% F.S.Range Ability 40:1 Turn DownStability ±0.2% URL/5 yearsTemperature Limits -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 300 PSIG (0.4 bar to 20.6 bar)Power Requirements 10.5 to 55 VDCOutput Signal Two wire, 4- 20 mA with HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 ΩElectrical Connection ½” female NPT conduitProcess Connection 1-½” Tri-Clamp or 2” Tri-Clamp Display 5 digit LCD Weight 3.43 lb (1.56 kg) Enclosure Rating NEMA 4 x (IP66)

Page 18: Technology Solutions - Tek-Trol · 08 Vortex Flowmeter - Tek-Vor 1300C Thermal Mass Flowmeter - Tek-Thermal 1700B Service Air and Nitrogen Wetted Material 316 SS Accuracy ±0.5% of

18 23

Smart Differential Pressure Transmitter - Tek-Bar 3110B

Service Compatible gases, steam, liquids Wetted Materials Hastelloy C, 316 SSAccuracy 0.075% of URL Range Ability 100:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSID to 5800 PSID (0.4 bar to 100 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ¼" female NPT Display Optional 5 digit LCD Weight 8.8 lb (4.0 kg) Enclosure Rating NEMA 4 x (IP66)

Explosion-Proof Gauge Pressure Transmitter - Tek-Bar 3120A

34 35

Service Compatible gases, steam, liquids Wetted Materials 316 SSAccuracy 0.075% of URL Range Ability 100:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ½" male NPT Display Optional 5 digit LCD Weight 3.43 lb (1.56 kg) Enclosure Rating NEMA 4 x (IP66)Agency Approval CE, FM (ClassⅠ, DivⅠ )