4
50

TECHNICAL SPECIFICATIONS - spc.co.za HDPE flexpro brochure.pdf · TECHNICAL SPECIFICATIONS ISO 9001:2008 • The pipe is black outside and inside. • Supplied in coils of 50 meters,

Embed Size (px)

Citation preview

Page 1: TECHNICAL SPECIFICATIONS - spc.co.za HDPE flexpro brochure.pdf · TECHNICAL SPECIFICATIONS ISO 9001:2008 • The pipe is black outside and inside. • Supplied in coils of 50 meters,

50

6 Main Reef Road, Dunswart, Boksburg, GautengPO Box 6546, Dunswart, 1508

Tel + 27 (0)11 914 8500/1/2/3 Fax +27 (0)11 914 4524

E-mail: [email protected]

GPS co-ordinates: S26º12.31’ E028º16.52’

50

NOW SANS Accredited

Page 2: TECHNICAL SPECIFICATIONS - spc.co.za HDPE flexpro brochure.pdf · TECHNICAL SPECIFICATIONS ISO 9001:2008 • The pipe is black outside and inside. • Supplied in coils of 50 meters,

TECHNICAL SPECIFICATIONSISO 9001:2008

• The pipe is black outside and inside.• Supplied in coils of 50 meters, as well as 6meter lengths, complete with couplings. • The manufacturer’s Quality Management System is certified to UNI EN ISO 9001:2008. • Standard production conforms to BIG-DREN technical specifications.

GENERAL FEATURESDESIGN: Double-wall pipe, black outside, black inside.APPLICATION: Refer to section below. CRUSH RESISTANCE: 450N with 5% deformation of the internal diameter (measured according to SANS 61386-26N ).RADIUS OF BENDING: 15 times the external diameter (coils).PRESENTATION: 50 meters coils, 6 meter lengths.ACCESSORIES: Couplings.INSTALLATION: Underground.

TYPE TESTING (PHYSICAL TESTS)MELT FLOW RATE: According to ISO 1133: Condition 1T (test parameter: 190°C / 5 Kg / 10 mins) on raw materials

of both walls. DENSITY: according to ISO 1183: (test temperature: 23°C) on the pipe and on raw materials of both walls.

CONFORMITY TESTSVISUAL INSPECTION: According to UNI ISO 4582 sections 3-4. The product is marked with a clearly visible product

code printed longitudinally every 3 meters along the pipe.DIMENSIONS: Mean external diameter (de), minimum internal diameter (dim).CRUSH RESISTANCE: according to SANS 61386-24OPERATING LIMITS: -50°C to +60°C.

6m LENGTHS with 240º SLOTS 50m COILS with 360º SLOTS

Exterior diameter (mm) 75 110 160 Exterior diameter (mm) 75 110 160

Interior diameter (mm) 60 92 137 Interior diameter (mm) 60 92 137

Infiltration area (mm2/m) 5400 6500 9000 Infiltration area (mm2/m) 6500 8000 11000

Nominal slot width (mm) 1.3 1.8 1.8 Nominal slot width (mm) 1.3 1.8 1.8

Number of slots per corrugation 2-3 2-3 5 Number of slots per corrugation 3 3 6

Length (m) 6 6 6 Length (m) (coils) 50 50 50

Ring stiffness N >450 >450 >450 Ring stiffness N >450 >450 >450

Our Technical Department is at your disposal for further information, documentation and design support.

Pipe sections are joined by means of (a) bell fittings, or (b) two-joint couplings complete with elastomer seals in the first groove of the pipe end to be inserted in the joint.

TECHNICAL SPECIFICATIONSSANS 61386-24 class NISO 9001:2008

• The pipe is green (telecommunication) or black (electricity) on the outside and black on the inside. • Supplied in lengths of 6 meters, or coils of 50 meters, complete with couplings. • The manufacturer’s Quality Management System is certified to UNI EN ISO 9001:2008. • Pipes conform to SANS 61386-24 and is marked as class N with crush resistance higher than 450 N.

GENERAL FEATURESDESIGN: Double-wall pipe in green (telecommunication) or black (electricity) on the outside and black on

the inside. APPLICATION: Protection of low and medium tension electrical cables, as well as telecommunication cables.CRUSH RESISTANCE: SANS 61386-24 with 5% deformation of internal diameter. STRUCTURE: Stabilised against UV rays and guaranteed for one year from the date of manufacture marked

on the pipe.PRESENTATION: 6 meters lengths; 50 meters coils.ACCESSORIES: Couplings. INSTALLATION: Underground.

TYPE TESTING (PHYSICAL TESTS)MELT FLOW RATE: According to ISO 1133: condition 1T (test parameter: 190°C / 5 Kg / 10 mins) on raw materials

of both walls.DENSITY: According to ISO 1183 (test temperature 23°C) on the pipe and on raw materials of both walls.

CONFORMITY TESTS VISUAL INSPECTION: According to UNI ISO 4582 sections 3-4. The product is marked with a clearly visible product

code printed longitudinally every 3 meters along the pipe. DIMENSIONS: Mean external diameter (cm), minimum internal diameter (dim).CRUSH RESISTANCE: According to SANS 61386-24.SHOCK RESISTANCE TEST: According to SANS 61386-24.OPERATING LIMITS: -50°C to +60°C.

External diameter DN/OD (mm) 50 75 90 110 160

Internal diameter (mm) 40 60 73 92 137

Stiffness resistance (N/ml) >450 >450 >450 >450 >450

Coils - meters per coil 50 50 50 50 50

Lengths – meter per length 6 6 6 6

External layer polyethylene PE-HD PE-HD PE-HD PE-HD PE-HD

Internal layer polyethylene PE-HD PE-HD PE-HD PE-HD PE-HD

Tolerance +- 2%

Page 3: TECHNICAL SPECIFICATIONS - spc.co.za HDPE flexpro brochure.pdf · TECHNICAL SPECIFICATIONS ISO 9001:2008 • The pipe is black outside and inside. • Supplied in coils of 50 meters,

TECHNICAL SPECIFICATIONSISO 9001:2008

• The pipe is black outside and inside.• Supplied in coils of 50 meters, as well as 6meter lengths, complete with couplings. • The manufacturer’s Quality Management System is certified to UNI EN ISO 9001:2008. • Standard production conforms to BIG-DREN technical specifications.

GENERAL FEATURESDESIGN: Double-wall pipe, black outside, black inside.APPLICATION: Refer to section below. CRUSH RESISTANCE: 450N with 5% deformation of the internal diameter (measured according to SANS 61386-26N ).RADIUS OF BENDING: 15 times the external diameter (coils).PRESENTATION: 50 meters coils, 6 meter lengths.ACCESSORIES: Couplings.INSTALLATION: Underground.

TYPE TESTING (PHYSICAL TESTS)MELT FLOW RATE: According to ISO 1133: Condition 1T (test parameter: 190°C / 5 Kg / 10 mins) on raw materials

of both walls. DENSITY: according to ISO 1183: (test temperature: 23°C) on the pipe and on raw materials of both walls.

CONFORMITY TESTSVISUAL INSPECTION: According to UNI ISO 4582 sections 3-4. The product is marked with a clearly visible product

code printed longitudinally every 3 meters along the pipe.DIMENSIONS: Mean external diameter (de), minimum internal diameter (dim).CRUSH RESISTANCE: according to SANS 61386-24OPERATING LIMITS: -50°C to +60°C.

6m LENGTHS with 240º SLOTS 50m COILS with 360º SLOTS

Exterior diameter (mm) 75 110 160 Exterior diameter (mm) 75 110 160

Interior diameter (mm) 60 92 137 Interior diameter (mm) 60 92 137

Infiltration area (mm2/m) 5400 6500 9000 Infiltration area (mm2/m) 6500 8000 11000

Nominal slot width (mm) 1.3 1.8 1.8 Nominal slot width (mm) 1.3 1.8 1.8

Number of slots per corrugation 2-3 2-3 5 Number of slots per corrugation 3 3 6

Length (m) 6 6 6 Length (m) (coils) 50 50 50

Ring stiffness N >450 >450 >450 Ring stiffness N >450 >450 >450

Our Technical Department is at your disposal for further information, documentation and design support.

Pipe sections are joined by means of (a) bell fittings, or (b) two-joint couplings complete with elastomer seals in the first groove of the pipe end to be inserted in the joint.

TECHNICAL SPECIFICATIONSSANS 61386-24 class NISO 9001:2008

• The pipe is green (telecommunication) or black (electricity) on the outside and black on the inside. • Supplied in lengths of 6 meters, or coils of 50 meters, complete with couplings. • The manufacturer’s Quality Management System is certified to UNI EN ISO 9001:2008. • Pipes conform to SANS 61386-24 and is marked as class N with crush resistance higher than 450 N.

GENERAL FEATURESDESIGN: Double-wall pipe in green (telecommunication) or black (electricity) on the outside and black on

the inside. APPLICATION: Protection of low and medium tension electrical cables, as well as telecommunication cables.CRUSH RESISTANCE: SANS 61386-24 with 5% deformation of internal diameter. STRUCTURE: Stabilised against UV rays and guaranteed for one year from the date of manufacture marked

on the pipe.PRESENTATION: 6 meters lengths; 50 meters coils.ACCESSORIES: Couplings. INSTALLATION: Underground.

TYPE TESTING (PHYSICAL TESTS)MELT FLOW RATE: According to ISO 1133: condition 1T (test parameter: 190°C / 5 Kg / 10 mins) on raw materials

of both walls.DENSITY: According to ISO 1183 (test temperature 23°C) on the pipe and on raw materials of both walls.

CONFORMITY TESTS VISUAL INSPECTION: According to UNI ISO 4582 sections 3-4. The product is marked with a clearly visible product

code printed longitudinally every 3 meters along the pipe. DIMENSIONS: Mean external diameter (cm), minimum internal diameter (dim).CRUSH RESISTANCE: According to SANS 61386-24.SHOCK RESISTANCE TEST: According to SANS 61386-24.OPERATING LIMITS: -50°C to +60°C.

External diameter DN/OD (mm) 50 75 90 110 160

Internal diameter (mm) 40 60 73 92 137

Stiffness resistance (N/ml) >450 >450 >450 >450 >450

Coils - meters per coil 50 50 50 50 50

Lengths – meter per length 6 6 6 6

External layer polyethylene PE-HD PE-HD PE-HD PE-HD PE-HD

Internal layer polyethylene PE-HD PE-HD PE-HD PE-HD PE-HD

Tolerance +- 2%

Page 4: TECHNICAL SPECIFICATIONS - spc.co.za HDPE flexpro brochure.pdf · TECHNICAL SPECIFICATIONS ISO 9001:2008 • The pipe is black outside and inside. • Supplied in coils of 50 meters,

50

6 Main Reef Road, Dunswart, Boksburg, GautengPO Box 6546, Dunswart, 1508

Tel + 27 (0)11 914 8500/1/2/3 Fax +27 (0)11 914 4524

E-mail: [email protected]

GPS co-ordinates: S26º12.31’ E028º16.52’

50

NOW SANS Accredited