2
© FAKRO Informational materials Strona 1/2 TECHNICAL SPECIFICATION I. APPLICATION Universal roof exit II. FEATURES Possibility of changing opening sides Multi chamber profiles in white colour (RAL 9010) System TopSafe Quadruple sealing system Universal installation system Warm TGI spacer Elegant handle white / silver III. ADDITIONAL PRODUCTS Flashing standard special combinations IV. OPTIONS Control manual Avaiable in veneer: golden oak and pine Mounting accessories insulation sets linings auxiliary rafters bands Window with mullion bar frame extensions External accessories External accessories to special order Non- standard glazing unit from FAKRO offer Internal accessories blackout blinds roller blinds standard blinds venetian blinds pleated blinds V. DECLARATION OF PERFORMANCE Other accesories Harmonized standard EN 14351-1:2006+A2:2016 awning blinds VI. TECHNICAL PARAMETERS PWP, PWP/PI, PWP/GO ALUMINIUM CLAD PLASTIC SIDE HUNG ESCAPE WINDOW WITH THE SASH OPENING TO THE RIGHT OR TO THE LEFT Installed in roofs with pitches 15-55 o External cladding elemnts painted in any RAL Classic colour in (CU,TC) Number of Declaration of Performance XXX/CPR/14351/XX Individual numbers of Declaration of Performance are to be found in the table with technical parameters * Result of FAKRO internal tests TECHNICAL PARAMETERS Glazing unit type U3 P2 U5 P5 STANDARDS window heat transmittance Uw [W/m²K] 1,4 1,4 1,2 1,2 EN 12567-2, EN 10077 - glazing heat transmittance Ug [W/m²K] 1,0 0,5 0,5 EN 673 - acoustic performance Rw [dB] 34 (-2;-5) 37 (-2;-5) 34 (-1;-4) 37 (-1;-4) EN ISO 717-1 - air permeability class 3 EN 1026, EN 12207 0,76 0,75 0,73 0,63 EN 410 - solar factor [ g] 0,53 0,52 0,53 0,48 EN 410 - permeability UV 0,26 0,01 0,28 0,01 EN 410 - frame thermal insulation Uf [W/m²K] npd npd npd npd npd npd npd npd W200/CPR/14351/xx W200/CPR/14351/xx W210/CPR/14351/xx W210/CPR/14351/xx EN 14351-1:2006+A2:2016 1,0 - light permeability tv EN ISO 10077-1 EN ISO 10077-2 - thermal insulation of window frame connection with glazing (psi) [W/mK] EN ISO 10077-1 EN ISO 10077-2 Number of Declaration of Performance

TECHNICAL SPECIFICATION PWP, PWP/PI, PWP/GO ALUMINIUM … · Non- standard glazing unit from FAKRO offer Internal accessories blackout blinds roller blinds standard blinds venetian

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TECHNICAL SPECIFICATION PWP, PWP/PI, PWP/GO ALUMINIUM … · Non- standard glazing unit from FAKRO offer Internal accessories blackout blinds roller blinds standard blinds venetian

© FAKRO Informational materials Strona 1/2

TECHNICAL SPECIFICATION

I. APPLICATION

Universal roof exit

II. FEATURES

Possibility of changing opening sides

Multi chamber profiles in white colour (RAL 9010)

System TopSafe

Quadruple sealing system

Universal installation system

Warm TGI spacer

Elegant handle white / silver

III. ADDITIONAL PRODUCTSFlashing

standardspecial

combinations IV. OPTIONSControl

manualAvaiable in veneer: golden oak and pine

Mounting accessoriesinsulation setsliningsauxiliary raftersbands

Window with mullion barframe extensions

External accessories

External accessories to special orderNon- standard glazing unit from FAKRO offer

Internal accessoriesblackout blindsroller blindsstandard blindsvenetian blinds

pleated blinds V. DECLARATION OF PERFORMANCE

Other accesoriesHarmonized standard EN 14351-1:2006+A2:2016

awning blinds

VI. TECHNICAL PARAMETERS

PWP, PWP/PI, PWP/GOALUMINIUM CLAD PLASTIC SIDE HUNG ESCAPE WINDOW WITH THE SASH OPENING TO THE RIGHT OR TO THE LEFT

Installed in roofs with pitches 15-55o

External cladding elemnts painted in any RAL Classic colour in (CU,TC)

Number of Declaration of Performance

XXX/CPR/14351/XXIndividual numbers of Declaration of Performance are to be found in the table with technical parameters

* Result of FAKRO internal tests

TECHNICAL PARAMETERSGlazing unit type

U3 P2 U5 P5 STANDARDS

window heat transmittance Uw [W/m²K] 1,4 1,4 1,2 1,2 EN 12567-2, EN 10077

- glazing heat transmittance Ug [W/m²K] 1,0 0,5 0,5 EN 673- acoustic performance Rw [dB] 34 (-2;-5) 37 (-2;-5) 34 (-1;-4) 37 (-1;-4) EN ISO 717-1- air permeability class 3 EN 1026, EN 12207

0,76 0,75 0,73 0,63 EN 410

- solar factor [ g] 0,53 0,52 0,53 0,48 EN 410

- permeability UV 0,26 0,01 0,28 0,01 EN 410

- frame thermal insulation Uf [W/m²K] npd npd npd npd

npd npd npd npd

W200/CPR/14351/xx W200/CPR/14351/xx W210/CPR/14351/xx W210/CPR/14351/xx EN 14351-1:2006+A2:2016

1,0

- light permeability tv

EN ISO 10077-1EN ISO 10077-2

- thermal insulation of window frame connection with glazing (psi) [W/mK]

EN ISO 10077-1EN ISO 10077-2

Number of Declaration of Performance

Page 2: TECHNICAL SPECIFICATION PWP, PWP/PI, PWP/GO ALUMINIUM … · Non- standard glazing unit from FAKRO offer Internal accessories blackout blinds roller blinds standard blinds venetian

© FAKRO Informational materials Strona 2/2

VII. DETAILED DIMENSIONES OF PWP

Window sizeGlazing area

S x L p q m n a b z j k j * k[cm] [mm]

55 x 78 01 547 x 770 484 707 391 613 462 685 401 369 591 0,2255 x 98 02 547 x 970 484 907 391 813 462 885 401 369 791 0,2955 x 118 16 547 x 1170 484 1107 391 1013 462 885 401 369 991 0,3766 x 78 22 657 x 770 594 707 501 613 572 685 511 479 591 0,2866 x 98 03 657 x 970 594 907 501 813 572 885 511 479 791 0,3866 x 118 04 657 x 1170 594 1107 501 1013 572 1085 511 479 991 0,4778 x 98 05 777 x 970 714 907 621 813 692 885 631 599 791 0,4778 x 118 06 777 x 1170 714 1107 621 1013 692 1085 631 599 991 0,5978 x 140 07 777 x 1390 714 1327 621 1233 692 1305 631 599 1211 0,7394 x 98 15 937 x 970 874 907 781 813 852 885 791 759 791 0,6094 x 118 08 937 x 1170 874 1107 781 1013 852 1085 791 759 991 0,7594 x 140 09 937 x 1390 874 1327 781 1233 852 1305 791 759 1211 0,92

Symbol of size

Frame external size

Distance between

lining grooves

Dimensions for internal accessories

Dimensions in the frame light

Glazing visible area

[m²]