12
Technical specification Submersible pump B 2201, 50 Hz

Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

Technical specificationSubmersible pump B 2201, 50 Hz

Page 2: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

2

BIBO 2201

BIBO 2201ProductSubmersible pump for dewatering construction sites, draining water in flooded areas, handling water in mines or on oil platforms and other similar applications. The pump can handle water containing relatively abrasive solids.

DenominationProduct code 2201.011

2201.3202201.5902201.690

Installation S

Impeller characteristics

Process data Depth of immersion max 20 mLiquid density max.1100 kg/m3

Liquid temperature max +40°C

The pH of the pumped liquid

Strainer hole size

Motor dataFrequency 50 HzInsulation class H (+180 °C)Voltage variation

- continuously running max ± 5%- intermittent running max ± 10%

Voltage imbalance between phases max 2%No. of starts/hour max 30

CableDirect-on-line startSUBCAB® 4G10 mm2

4G10+2x1,5 mm2

4G16 mm2

4G16+2x1,5 mm2

4G25 mm2

4G35 mm2

Y/D startSUBCAB® 2x4G6 mm2

2x4G10 mm2

2x4G10+2x1,5 mm2

2x4G16 mm2

2x4G16+2x1,5 mm2

2x4G25 mm2

2x4G25+2x1,5 mm2

7G+2x1.5 mm2

Monitoring equipmentThermal contacts opening temp. 125°C

Product code Impeller characteristics2201.011 LT, MT, HT2201.320 MT, HT2201.590 MT, HT2201.690 MT, HT

Product code pH2201.011 5-82201.320 6-132201.590 6-132201.690 6-13

Product code Impeller characteristic Size2201.011 LT, MT 15 mm x 45 mm2201.011 HT 10 mm x 10 mm2201.320 MT 15 mm x 45 mm2201.320 HT 10 mm x 10 mm2201.590 MT 15 mm x 45 mm2201.590 HT 10 mm x 10 mm2201.690 MT 15 mm x 45 mm2201.690 HT 10 mm x 10 mm

Page 3: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

3

BIBO 2201

MaterialImpeller

Stator housing

Strainer

Shaft

O-rings

Wear parts

Mechanical face seals

Surface Treatment

WeightSee dimensional drawing.

Approvals2201.590 EN 50014, EN 50018, EEX de IIB T32201.690 EN 50014, EN 50018, EEX de I

OptionPolyurethane-lined wear parts

Impeller (HT) Stainless steelDischarge connection with coupling AO-rings (.320/.590/.690) VitonSiemens cable monitor (L-version.690)Sait cable monitor (L-version.690)Diode (.590)Warm liquid version on request (only 2201.320)Other cablesZinc anodesTandem connection

AccessoriesAdapters, hose connections and other mechanical accessories.Electrical accessories such as pump controller, control panels, starters, monitoring relays.See separate booklet or www.flygt.com, for further information.

Product code Impeller characteristics

Material

2201.011 LT High chrome alloyed white ironMT High chrome alloyed white ironHT High chrome alloyed white iron

Stainless steel2201.320 MT High chrome alloyed white iron

HT Spring steelStainless steel

2201.590 MT High chrome alloyed white ironHT Spring steel

Stainless steel2201.690 MT High chrome alloyed white iron

HT Spring steelStainless steel

Product code Material2201.011 Aluminium2201.320 Cast iron2201.590 Cast iron2201.690 Cast iron

Product code Material2201.011 Galvanized steel2201.320 Galvanized steel2201.590 Galvanized steel2201.690 Galvanized steel

Product code Material2201.011 Stainless steel2201.320 Stainless steel2201.590 Stainless steel2201.690 Stainless steel

Product code Material2201.011 Nitrile rubber2201.320 Nitrile rubber2201.590 Nitrile rubber2201.690 Nitrile rubber

Product code Material2201.011 Nitrile rubber2201.320 Nitrile rubber

Alternative Inner seal Outer seal1 Corrosion resistant

cemented carbide/Corrosion resistant cemented carbide

Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

2 Corrosion resistant cemented carbide/Corrosion resistant cemented carbide

Silicon carbide/Silicon carbide

Product code Treatment2201.011 The pump is sprayed with one layer of

aluminium paint.2201.320 Priming of castings and finishing coating

of synthetic resin enamel in orange colour.

2201.590 Priming of castings and finishing coating of synthetic resin enamel in black colour.

2201.690 Priming of castings and finishing coating of synthetic resin enamel in black colour.

Product code Material2201.011 POLY-LIFE®

2201.320 POLY-LIFE®

Page 4: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

4

BIBO 2201

LT-Motor rating and performance curve2201.011

Y/D starting current is approximately 1/3 of D starting current.

MT-Motor rating and performance curve2201.011/.320/.590/.690

Y/D starting current is approximately 1/3 of D starting current.

Cur

ve/Im

pelle

r No

Rat

ed P

ower

, kW

Rat

ed c

urre

nt, A

Star

ting

curr

ent,

A

Pow

er fa

ctor

cos

ϕ Ex

pro

of v

ersi

on a

vaila

ble

400 V, 50 Hz, 3 ~, 1465 r/min411 30 57 450 0,85412 30 57 450 0,85

Cur

ve/Im

pelle

r No

Rat

ed P

ower

, kW

Rat

ed c

urre

nt, A

Star

ting

curr

ent,

A

Pow

er fa

ctor

cos

ϕ Ex

pro

of v

ersi

on a

vaila

ble

400 V, 50 Hz, 3 ~, 2945 r/min231 37 65 430 0,92 •232 37 65 430 0,92 •

�������

���

�� � ��

� �� �� ��� ��� ����

��

��

��

��

��

��

��

��

���

���

���

���

�������

���

�� � ��

� �� �� �� �� ��� ��� ��� ����

��

��

��

��

��

��

��

��

��

��

��

��

��

���

���

���

���

Page 5: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

5

BIBO 2201

HT-Motor rating and performance curve2201.011/.320/.590/.690

1) Only 2201.011

Y/D starting current is approximately 1/3 of D starting current.

2201.320/.590/.690

Y/D starting current is approximately 1/3 of D starting current.

Cur

ve/Im

pelle

r No

Rat

ed P

ower

, kW

Rat

ed c

urre

nt, A

Star

ting

curr

ent,

A

Pow

er fa

ctor

cos

ϕ Ex

pro

of v

ersi

on a

vaila

ble

400 V, 50 Hz, 3 ~, 2945 r/min233 37 65 430 0,92 •234 37 65 430 0,92 •

2431) 37 65 430 0,92

2441) 37 65 430 0,92

Cur

ve/Im

pelle

r No

Rat

ed P

ower

, kW

Rat

ed c

urre

nt, A

Star

ting

curr

ent,

A

Pow

er fa

ctor

cos

ϕ Ex

pro

of v

ersi

on a

vaila

ble

400 V, 50 Hz, 3 ~, 2945 r/min253 37 65 430 0,92 •254 37 65 430 0,92 •

�������

���

�� � ��

� �� �� �� �� �� ���

��

��

��

��

��

��

��

��

��

��

��

��

��

��

���

���

���

���

���

���

���

���

�������

���

�� � ��

� �� �� �� �� �� ���

��

��

��

��

��

��

��

��

��

��

��

��

��

��

���

���

���

���

Page 6: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

6

BIBO 2201

Dimensional drawingAll drawings are available as Acrobat documents (.pdf) and AutoCad drawings (.dwg). Download the drawings from www.flygt.com or contact your ITT Flygt representative for more information.

All dimensions are in mm.

LT, S-installation

LT, S-installation LT, S-installation

Page 7: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

7

BIBO 2201

LT, S-installation LT, S-installation

LT/MT, S-installation MT, S-installation

Page 8: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

8

BIBO 2201

MT, S-installation MT, S-installation

MT, S-installation MT, S-installation

Page 9: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

9

BIBO 2201

MT, S-installation MT, S-installation

MT, S-installation MT, S-installation

Page 10: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

10

BIBO 2201

MT, S-installation HT, S-installation

HT, S-installation HT, S-installation

Page 11: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

11

BIBO 2201

HT, S-installation HT, S-installation

HT, S-installation

Page 12: Technical specification - PROREM 2201 specyfikacja techniczna (EN).pdf2201.320 2201.590 2201.690 Installation S Impeller characteristics Process data Depth of immersion max 20 m Liquid

www.flygt.com B220

1.50

Hz.

04.E

N_G

B.10

07 ©

ITT

Flyg

t AB

8

9464

6