30
Technical Presentation November 2006

Technical Presentation

Embed Size (px)

DESCRIPTION

Technical Presentation. November 2006. Who Are We?. We are the leading provider of Next Generation Water Disinfection Solutions. We bring a revolutionary disinfection technology Hydro-Optic Disinfection (HOD): Environmentally friendly Simple to use and maintain - PowerPoint PPT Presentation

Citation preview

Page 1: Technical Presentation

Technical Presentation

November 2006

Page 2: Technical Presentation

2

Who Are We?Who Are We?

We are the leading provider of

Next Generation

Water Disinfection Solutions

We bring a revolutionary disinfection technology

Hydro-Optic Disinfection (HOD): Environmentally friendly Simple to use and maintain At a low cost of ownership Really does the job…

Page 3: Technical Presentation

3

Company Profile Company Profile

Founded in March 2003

Raised $30M to date from leading investors

HQ in Israel – home to renowned innovation in high-tech and water technologies

50 employees and growing

Seasoned water sector management

Interdisciplinary team of top scientists and engineers

Comprehensive Intellectual Property Portfolio

Proven the technology in industrial installations

Page 4: Technical Presentation

4

Water Disinfection Technologies TodayWater Disinfection Technologies Today

Extremely high operational cost; Intensive maintenance

Reliable; Wide acceptance

Heat exchange Heat exchange (pasteurization) (pasteurization)

IssuesAdvantages

Microbial Kill 1-3 log range; Deposits & fouling of quartz sleeves; High maintenance; Questionable reliability; Issues with monitoring and control

Environmentally Friendly;Acceptable

Conventional Conventional UVUV

Expensive to buy & operate; Stops microbes only above certain threshold; Sensitive to chlorine; Backwash treatment and biofilms breed hidden costs over time

Reliable;Wide acceptanceMembranesMembranes

Disinfection by-products (Bromates); Hard to control with water quality flux; Difficult working environment; Lots of hidden costs

Effective;Accepted for some industries

OzonationOzonation

Disinfection by-products; Taste in food; Ineffective against Cryptosporidium & Giardia; Creates issues for downstream processing - membranes

Relatively cheap; Widely used and accepted

ChlorinationChlorination

Page 5: Technical Presentation

5

HOD’s Out-of-the-Box DesignHOD’s Out-of-the-Box Design

Light beams represent how the fiber optic Total Internal Reflection principle works

11

2

3 3

4

Out-of-the-water light sources1

Air cooled dry chamber2

Dual sensor configuration for accurate monitoring3

Central quartz chamber traps light photons4

Page 6: Technical Presentation

6

Technology PrincipleTechnology Principle

“The Liquid Wave Guide“

Same “Total Internal Reflection” principle as in optical fibers

Page 7: Technical Presentation

7

Operation PrinciplesOperation Principles

HOD system cross sectionHOD system cross sectionHOD system cross sectionHOD system cross section

Quartz Window

Lamp status monitors

Water transmission monitor

AIR

AIR

AIR

AIR

WATER

* Medium Pressure High Intensity

Air Cooling

Quartz Tube

Air BlockMPHI* UV

Light Source

Reflector

Page 8: Technical Presentation

8

Microbial contamination in test point of dairy water systemMicrobial contamination in test point of dairy water system

The Atlantium “Total Kill” SolutionThe Atlantium “Total Kill” Solution

Microbial contamination in test points of water system (June - July, 2005)

21.0717.0710.0730.06 4.0723.06 27.0619.0614.069.065.062.06 24.07 27.071.00E+00

1.00E+01

1.00E+02

1.00E+03

1.00E+04

1.00E+05

1.00E+06

Date of test

CF

U/1m

l

System entrance

System exit

Far sampling point

Page 9: Technical Presentation

9

Conventional UV Conventional UV

Microbes may escape UV

Many lamps, light cannot be uniform

Page 10: Technical Presentation

10

The HOD Advantage I: Performance and ReliabilityThe HOD Advantage I: Performance and Reliability

HOD System HOD System HOD System HOD System

WATER

Conventional UV Conventional UV Conventional UV Conventional UV

Heat generates sleeve deposits; Requires frequent

maintenance

Uniform dose distribution

Non-uniform dose distribution

Page 11: Technical Presentation

11

HOD System HOD System HOD System HOD System

WATER

4 minutes replacement; No system downtime

Cumbersome lamp & sleeve replacements; System down

Risk of glass and mercury droplets into the water

The HOD Advantage II: Simple MaintenanceThe HOD Advantage II: Simple Maintenance

Conventional UV Conventional UV Conventional UV Conventional UV

Page 12: Technical Presentation

12

WATER

Conventional UV Conventional UV Conventional UV Conventional UV Measuring UV light through water (light, sleeve fouling, and water)

Direct measurement of UV source

Additional detector for water turbidity

The HOD Advantage III: Monitoring and ControlThe HOD Advantage III: Monitoring and Control

HOD System HOD System HOD System HOD System

Page 13: Technical Presentation

13

The HOD Advantage III: Monitoring and ControlThe HOD Advantage III: Monitoring and Control

State-of-the-art set up, control & monitoring

State-of-the-art set up, control & monitoring

Page 14: Technical Presentation

14

The HOD Advantage III: Monitoring and ControlThe HOD Advantage III: Monitoring and Control

Configure validated doseConfigure validated dose

Page 15: Technical Presentation

15

The HOD Advantage III: Monitoring and ControlThe HOD Advantage III: Monitoring and Control

Automated EPA reporting

Automated EPA reporting

Page 16: Technical Presentation

16

R-Series modelsR-Series models

HOD R – 200 DL model HOD R – 200 SL model

HOD PR – 20 model

Page 17: Technical Presentation

17

Overview:Markets & ProductsOverview:Markets & Products

R - models covering flow rates from 10 – 300 m3/hr

Industrial and Municipal markets:

Municipal Drinking water Water Re-use Desalination

Industrial Food & Beverage Aquaculture Power plants Pharmaceuticals Other

Page 18: Technical Presentation

18

Product WaterProduct Water

FireWallFireWall Process Water Process Water

PasteurizationPasteurization

Industrial Markets:F&B ApplicationsIndustrial Markets:F&B Applications

Page 19: Technical Presentation

19

HOD “FireWall”The ideal solution for the Food & Beverage industryHOD “FireWall”The ideal solution for the Food & Beverage industry

Inactivate all harmful microorganisms

Maximize plant water quality

Minimize the use of chemicals andavoid residual carcinogenic substances

Save on electricity, chlorine and labor costs

ROI in less than one year

Page 20: Technical Presentation

20

“HOD FireWall” at work:TNUVA E.T. – One of the World’s Largest Dairies“HOD FireWall” at work:TNUVA E.T. – One of the World’s Largest Dairies

3 x 100 m3/hr Atlantium HOD Units

External View of Atlantium’s Facility

Note Far Sampling point – 500 m’ down the line from the HOD system

Microbial contamination in test points of water system (June - July, 2005)

21.0717.0710.0730.06 4.0723.06 27.0619.0614.069.065.062.06 24.07 27.071.00E+00

1.00E+01

1.00E+02

1.00E+03

1.00E+04

1.00E+05

1.00E+06

Date of test

CF

U/1m

l

System entrance

System exit

Far sampling point

Microbial contamination in test point of dairy water systemMicrobial contamination in test point of dairy water system

Page 21: Technical Presentation

21

PasteurizationPasteurization

Up: Conventional Pasteurization systemUp: Conventional Pasteurization systemDown: Atlantium’s HOD PR - 20 unitDown: Atlantium’s HOD PR - 20 unit

HOD PR – 20 unit

Validated 9 Log reduction

Significant savings on energy and operation costs

Page 22: Technical Presentation

22

Pasteurization:The Atlantium AdvantagePasteurization:The Atlantium Advantage

Conventional PasteurizationConventional PasteurizationAtlantium’s SolutionAtlantium’s Solution

1-1.2 Euro per m³ energy cost0.05 Euro per m³ energy cost

Major maintenance requirementSimple & easy maintenance

Significant system downtimeAlmost no system downtime

Large FootprintSmall Footprint

Page 23: Technical Presentation

23

TOC & THMs ReductionTOC & THMs Reduction

Efficient way to reduce TOC & THMs:

Creation of “radicals-saturated” zone

All water are exposed to “radicals-saturated” zone

Continuous generation of radicals

Utilization of entire HOD reactor’s chamber for chemical reaction

Reduces chlorine usage to a minimum

Cost Effective:

Eliminated the need for PAC and UF Membranes

Reduces O&M costs

Page 24: Technical Presentation

24

Case Study:Site installation, Dresden – GermanyCase Study:Site installation, Dresden – Germany

HOD effect on average chlorine presence in tested waterHOD effect on average chlorine presence in tested water

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

mg/l

cl-

Free Chlorine 0.39 0.56

Bounded Chlorine 0.29 0.08

Total Chlorine 0.68 0.64

PAC On; HOD Off (15-24/4/2006) PAC Off; HOD On (12-21/6/2006)

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

mg/l

cl-

Free Chlorine 0.39 0.56

Bounded Chlorine 0.29 0.08

Total Chlorine 0.68 0.64

PAC On; HOD Off (15-24/4/2006) PAC Off; HOD On (12-21/6/2006)

Page 25: Technical Presentation

25

Industrial Markets:Aquaculture ApplicationsIndustrial Markets:Aquaculture Applications

Page 26: Technical Presentation

26

Fish HatcheriesFish Hatcheries

Increases fish growth rates

Increases survival rates

Minimizes drugs, chemicals and antibiotics

Improves FCR (Fish Conversion Rate)

Environmentally friendly

Page 27: Technical Presentation

27

Case Study:Pinar Fish HatcheryCase Study:Pinar Fish Hatchery

Increase in survival rates: Sea Bream: 100% Sea Bass: 50%

Reduce Antibiotics use by 90%

Reduced full time maintenance person

ROI in less than 4 months

Customer ordered 2nd unit

Page 28: Technical Presentation

28

SummarySummary

Leader in innovative water disinfection solutions: Introducing Hydro-Optic Disinfection (HOD) technology A Revolutionary primary disinfection method

Dozens of successful industrial installations

Comprehensive Intellectual Property (IP) portfolio Seasoned management, academic and R&D staff Registered and pending patents worldwide

Operations in Europe, US and Asia – over 20 countries worldwide

Partnering with reps/ distributors and water companies for sales, installation, support, distribution, and R&D projects

Page 29: Technical Presentation

29

Most important …Most important …

TheThe

FactorFactor

SleepSleep Well Well

At NightAt Night (SWAN)(SWAN)

Page 30: Technical Presentation

Atlantium Ltd.

Har Tuv Industrial Park

POB 11071, Bet Shemesh 99100, Israel

Tel : + 972 2 992 5001 Fax : + 972 2 992 5005

[email protected] www.atlantium.com

THANK YOU!