Technical Data OEF-P – High-Bay Fixture Mount sheet.pdf · OEF-P – High-Bay Fixture Mount Overview…

  • Published on
    09-Nov-2018

  • View
    212

  • Download
    0

Transcript

<ul><li><p>Technical Data Effective November 5, 2014</p><p>OEF-P High-Bay Fixture Mount</p><p>OverviewThe OEF-P sensor controls fluorescent fixtures and can be mounted directly to the fixtures via a 1/2 knock out. The nipple on the sensor attaches with a lock nut through a 1/2 knockout on the fixture or on a junction box and all wiring passes through the same knockout.</p><p>Features Applications up to 40 feet in height Coverage diameter of twice the mounting height (2MH) Built in power supply, relay and light level sensor Zero-Crossing Technology prolongs relay life by switching high-inrush equipment at close to zero power</p><p> Compatible with electronic ballasts, incandescent lighting or motor loads</p><p> No minimum load required Direct installation to fixture; fits standard 1/2 knockout</p><p>Catalog# Prepared by</p><p>Project Date</p><p>Comments Type</p><p>Technical Data </p><p>PIRActivated</p></li><li><p>2</p><p>Technical Data November 2014</p><p>OEF-P High-Bay Fixture Mount </p><p>www.coopercontrol.com</p><p>Specifications</p><p>Technology Passive Infrared (PIR)Electrical Ratings</p><p>Contacts:800 VA @ 120 VAC Tungsten800 VA @ 120 VAC Ballast1200 VA @ 240-277 VAC Ballast</p><p>Input 120/277 VAC +/- 10% 60HzLight Level Sensing</p><p>0 to 200 foot-candles</p><p>Operating Environment</p><p>Temperature: 32F - 104F (0C - 40C)Relative humidity: Less than 95%, non-condensingFor indoor use only</p><p>Housing Durable, injection molded housing. Polycarbonate resin complies with UL 94V-0</p><p>Size 3.08"H x 3.08"W x 1.70"D (78.232mm x 78.232mm x 43.180mm)</p><p>Standards FCC Compliant UL Listed</p><p>Description/OperationThe OEF-P, High-bay sensors are designed to detect motion from a heat-emitting source (such as a person entering a space) within its field-of-view and automatically switch lights ON. Lights will remain ON until no motion is detected and a preset time delay has expired. If no motion is detected during the time delay, the relay is opened, turning the load off. No adjustments are needed at installation. After the installer test, the sensor will automatically set itself to the default 10-minute time delay. At installation, the sensor will scan the coverage area to determine the optimum sensitivity setting.</p><p>Applications Warehouses Manufacturing Garages High Ceilings</p></li><li><p>3</p><p>Technical Data November 2014</p><p>OEF-P High-Bay Fixture Mount </p><p>www.coopercontrol.com</p><p>Wiring Diagrams</p><p>LINE</p><p>HOT</p><p>NEUTRAL</p><p>BLACK</p><p>WHITE 120-277 VAC**</p><p>BLUELOAD</p><p>NOTE:120 VAC INCANDESCENT/TUNGSTEN;MAX. LOAD: 6.7 AMPS, 800VA, 60HZ</p><p>120 VAC FLUORESCENT/BALLAST;MAX. LOAD: 6.7 AMPS, 800VA, 60HZ</p><p>240-277 VAC FLUORESCENT/BALLAST;MAX. LOAD: 4.3 AMPS, 1200VA, 60HZ</p><p>Coverage</p><p>Mounting</p><p>OEF-P-2MH0-MV-S Note:N Sensor needs to be mounted on fix-ture so that fixture does not block sensor field of view.</p></li><li><p>Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com</p><p>Eatons Cooper Controls Business203 Cooper CirclePeachtree City, GA 30269coopercontrol.com</p><p> 2014 EatonAll Rights ReservedPrinted in USAPublication No. ACC141017November 5, 2014</p><p>Eaton is a registered trademark.</p><p>All other trademarks are property of their respective owners.</p><p>Technical Data November 2014</p><p>OEF-P High-Bay Fixture Mount </p><p>Coverage HoodsComes with each sensor</p><p>180 Dtgrtt Aislt CusoNm</p><p>Note:N Custom hood sections can be broken off to create custom pattern.</p><p>OrderingCatalog # Mounting Photocell Wire Lead Length</p><p>OEF-P-2MH0-MV-S Side Yes 36 inces</p></li></ul>