technical data

FAQ-BVV1B

Wall Mounted Unit

air conditioning systems

SplitSky Air

Page 2: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Split Sky Air � Indoor Units 1

� Indoor Units � R-410A � FAQ-BVV1B

TABLE OF CONTENTSFAQ-BVV1B

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 For indoor units only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3 Safety device settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

4 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

5 Control systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

6 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 8Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

7 Piping diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

8 Wiring diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Sound level data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

10 Air flow pattern. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

11 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Page 3: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

1

� Split Sky Air � Indoor Units2

1 Features

Indoor Unit Split Sky FAQ-BVV1B R-410A � Lightweight and compact

� Ideal for shops, restaurants or offices requiring maximum floor space for furniture, decorations and fittings

� Fits neatly on a wall

� Nice design and very compact casing

� Both horizontal flaps and front panel can easily be removed and washed

� Auto-swing function ensures efficient air distribution via louvers that close automatically when the unit is switched off

� Extremely quiet in operation

� Easy to install

� Daikin remote controls give you easy control at your fingertips.

� The wired remote control provides you with a schedule timer, enabling to program the air conditioning daily or weekly.

� The optional remote ON/OFF enables you to start/stop the air conditioning from a mobile phone via a telephone remote control (field supply).

� The optional forced OFF enables you to switch off the unit automatically. E.g. when a window is opened, the unit switches off.

� The �home leave� operation button prevents large temperature differences by continuously operating at a minimum (heating mode) or maximum (cooling mode) preset level while you�re out or sleeping. It also allows the indoor temperature to return quickly to your favourite comfort level.

heat pump optional 2 steps optional

optional

Page 4: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

2

� Split Sky Air � Indoor Units 3

� Indoor Units � R-410A � FAQ-BVV1B

2 Specifications

2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B

Nominal Input Cooling kW 0.068 0.101Heating kW 0.068 0.101

2-2 TECHNICAL SPECIFICATIONS FAQ71BVV1B FAQ100BVV1B

Casing Colour WhiteMaterial Resin

Dimensions Packing Height mm 366 483Width mm 1147 1740Depth mm 337 299

Unit Height mm 290 360Width mm 1050 1570Depth mm 230 200

Weight Unit kg 13.0 26.0Packed Unit kg 17.0 34.0

Heat Exchanger

Dimensions Length mm 863 1320Nr of Rows 2 2Fin Pitch mm 1.40 1.40Nr of Passes 4 9Face Area m² 0.289 0.332Nr of Stages 16 12Empty Tubeplate Hole

2

Tube type Hi-XA N-HixFin Type Cross fin coil (Multi louver fins and HI-XA tubes) Cross fin coil (Multi louver fins and N-hix tubes)

Fan Type Cross flow fanQuantity 1 1

Air Flow Rate Cooling High m³/min 19.0 23.0Low m³/min 15.0 19.0

Heating High m³/min 19.0 23.0Low m³/min 15.0 19.0

Fan Motor Quantity 1 1Model QCL9686M QCL1163MA+QCL1163MBNumber of steps 2 2Output (high)

W 43 49

Cooling Sound Power High dBA 59.0 61.0Low dBA 53.0 57.0

Sound Pressure

High dBA 43.0 45.0Low dBA 37.0 41.0

Heating Sound Power High dBA 59.0 61.0Low dBA 53.0 57.0

Sound Pressure

High dBA 43.0 45.0Low dBA 37.0 41.0

Refrigerant Type R-410APiping connections

Liquid (OD) Type Flare connectionDiameter (OD)

mm 9.5 9.5

Gas Type Flare connectionDiameter (OD)

mm 15.9 15.9

Drain Diameter (OD)

mm VP13 (I.D. 13/O.D. 18) VP20 (I.D. 20/O.D. 26)

Heat Insulation Foamed polystyrene/polyethyleneSafety Devices PC board fuse

Page 5: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

2

� Split Sky Air � Indoor Units4

2 Specifications

Standard Accessories

Item Installation and operation manualQuantity 1 1Item Paper pattern for installation

Insulation tapeInstallation panel

ScrewsInsulation for fitting

Notes The sound pressure level is measured via a microphone at 1m distance of the unit.Sound pressure level is a relative value, depending on the distance and acoustic environment. For more details, please

refer to sound level drawings of this chapter.The sound power level is an absolute value indicating the power which a sound source generates.

2-3 ELECTRICAL SPECIFICATIONS FAQ71BVV1B FAQ100BVV1B

Power Supply Phase V1 V1Frequency Hz 50 50Voltage V 220-240

Power Supply Intake Outdoor unit only

2-2 TECHNICAL SPECIFICATIONS FAQ71BVV1B FAQ100BVV1B

Page 6: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

3

3

� Split Sky Air � Indoor Units 5

� Indoor Units � R-410A � FAQ-BVV1B

3 Safety device settings

FAQ71-100B

Model Safety devices FAQ71B FAQ100B

FAQ∼B

Fuse − −Fan motor thermal fuse (°C) − −

Fan motor thermal protector (°C) − OFF: 130±5ON: 83±20

DU423-9101L

Page 7: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

4

� Split Sky Air � Indoor Units6

4 Options

Optional accessories FAQ71B FAQ100B

Remote control Wired BRC1D528

Infrared type Heat pump BRC7EA618 BRC7CA510W

Cooling only BRC7EA619 BRC7CA511W

Wiring adapter for electrical appendices (2)* *KRP4AA51

Installation box for adapter PCB KRP4AA93 -

Central remote control DCS302CA51

Electrical box with earth terminal (3 blocks) KJB311AA

Unified ON/OFF control DCS301BA51

Electrical box with earth terminal (2 blocks) KJB212AA

Noise filter (for electromagnetic interface use only) KEK26-1A -

Schedule timer DST301BA51

Interface adapter for Sky Air series - DTA112BA51

Remote sensor KRCS01-1A -

Drain up kit K-KDU572CVE -

Connector for forced on, forced off - EKROROA

3D044482A

Note:

1. Installation box (KRP4AA93) is necessary for each adapter marked*

Page 8: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

3

5

� Split Sky Air � Indoor Units 7

� Indoor Units � R-410A � FAQ-BVV1B

5 Control systems

3TW23651-2

6.5 x 9 (Round end slit)

Cover open

Cover closed

5 x 7 (Round end slit) HoleJ5

5 x 10 (Round end slit)

BRC1D527

Page 9: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

6

� Split Sky Air � Indoor Units8

6 Dimensional drawing & centre of gravity6 - 1 Dimensional drawing

3D038540C

unit (mm)

50or

mor

e30

orm

ore

(Req

uire

dsp

ace)

J80 hole

approx. 345

approx. 475

FAQ71B

approx. 400

Mounting location

approx. 390

Piping direction

(Required space)

50 or more

Dimensions forfull open frontpanel

Outside line

J80 hole

(piping and wiringintake)

2500 or moreFor installation in high

spaces

(Req

uire

dsp

ace)

120 or less

1 Front panel2 Front grille3 Air outlet4 Gas pipe (J15.9 Flare connection)5 Liquid pipe (J9.5 Flare connection)6 Drain hose VP13 (External dia J18)7 Grounding terminal (M4)8 Right side piping connection hole9 Left side drain piping connection hole

Notes:1 Location of general rated name plate

Right side plate outside surface2 In case of using infrared remote control,

this position will be a signal receiver.Refer to the drawing of infrared remotecontrol in detail.

Name plate

50 or more

Piping directionNote) 2

Piping direction

(Required space)

3D044897A

unit (mm)

50or

mor

e

250 or more

(Req

uire

dsp

ace)

J80 hole

approx. 450

approx. 600

FAQ100B

8-5x20 Oval hole (for wood screw)

Mounting locationDetailjA (Mounting hole for installation plate)

approx. 580

Piping direction

(Required space)

50 or more50 or more

(Required space)

5-6x20 Oval hole (for wood screw)

13-J5 Hole (for wood screw)

2-J12 Hole (for bolt)(piping and wiringintake)

Note 2. (service space for air filter)

Direction for air filter draw out

1 Front grille2 Air filter3 Discharge outlet4 Gas piping connection (J15.9 flare)5 Gas piping connection (J9.5 flare)6 Drain pipe connection (VP20 O.D. J26)7 Earth terminal(M4) (inside cover)8 Slit hole for right side piping connection9 Slit hole for left side piping connection

Notes:1 Location of general rated name plate

Right side plate outside surface2 In case of using infrared remote control, this

position will be a signal receiver. Refer to thedrawing of infrared remote control in detail.

Brand name plate

Ceiling surface

Page 10: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

7

� Split Sky Air � Indoor Units 9

� Indoor Units � R-410A � FAQ-BVV1B

7 Piping diagram

4D037995B

O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe

Indoor heat exchanger

Field piping J9. 5C1220T-0

FAQ71-100B

Field piping J15.9C1220T-0

Refrigerant pipe connection port diameters

Model A BFAQ71, 100B J 9.5 J 15.9

To outdoor unit

Indoor unit

Page 11: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

8

� Split Sky Air � Indoor Units10

8 Wiring diagram8 - 1 Wiring diagram

3D043881A

FAQ71B

A1P Printed circuit boardHAP Light emitting diode (service monitor green)M1S Motor (swing flap)M1F Motor (indoor fan)R1T Thermistor (air)R2T Thermistor (coil)SS1 Selector switch (emergency)X1M Terminal blockX2M Terminal block

Power supply? Signal receiver circuit. Signal transmission circuit

Infrared remote controlReceiver / display unitA2P Printed circuit boardA3P Printed circuit boardBS1 Push button (on/off)H1P Light emitting diode (on-red)H2P Light emitting diode (timer-green)H3P Light emitting diode (filter sign-red)H4P Light emitting diode (defrost-orange)SS1 Selector switch (main/sub)SS2 Selector switch (wireless address set)

Connector for optional partsX15A Connector (float switch)X35A Connector (group control adapter)Wired remote controlR1T Thermistor (air)SS1 Selector switch (main/sub)

To outdoorunit

Note) 4

In case of simultaneousoperation system.

Toou

tdoo

runi

t

Notes

1. D : Terminal, F : Connector, : Field wiring2. In case using central remote control, connect it to the

unit in accordance with the attached instructionmanual.

3. Remote control model varies according to thecombination system, confirm technical materials andcatalogs, etc. before connecting.

4. X24A is connected when the infrared remote controlkit is being used.

5. Shows short circuit connector6. Symbols show as follows Red:red, Blk:black, Ylw:yellow,

Org:orange, Gry:gray, Prp:purple, Blu:blue7. Confirm the method of setting the selector switch (SS1,

SS2) by installation manual and engeneering materials,etc.

Receiver / display unit (attached to infrared remote control)

Note) 4

Indoor unit(master)

Indoor unit(slave)

Remote control

Norm. Emerg.

Note) 2

Transmission wiringcentral remote control

Wired remote control

Control box

SIDE FRONT

ON/OFF input from outside

3D044228A

FAQ100B

A1P Printed circuit boardA2P Printed circuit board

(Transformer) 230V/16V)C1R Capacitor (M1F)HAP Light emitting diode (service monitor green)KAR Magnetic relay (M1S)KPR Magnetic relay (M1P)M1F Motor (indoor fan)M1S Motor (swing flap)Q1M Thermo switch (M1F embedded)R1T Thermistor (air)R2T Thermistor (coil)

S1Q Limit switch (swing flap)SS1 Selector switch (emergency)V1TR Phase control circuitX1M Terminal blockX2M Terminal block? Signal receiver circuit. Signal transmission circuitWired remote controlR1T Thermistor (air)SS1 Selector switch (main/sub)

Infrared remote controlReceiver / display unitA3P Printed circuit boardA4P Printed circuit boardBS1 Push button (on/off)H1P Light emitting diode (on-red)H2P Light emitting diode (timer-green)H3P Light emitting diode (filter sign-red)H4P Light emitting diode (defrost-orange)SS1 Selector switch (main/sub)SS2 Selector switch (wireless address set)

Connector for optional partsX15A Connector (float switch)X25A Connector (drain pump)X35A Connector (group control adapter)X16AX61A

Connector (interface adapter for sky air series)

To outdoorunit

Note) 4

Wired remotecontrol

Control box

In case of simultaneousoperation system.

Toou

tdoo

runi

t

Notes

1. D : Terminal F, : Connector2. : Field wiring3. In case using central remote control, connect it to

the unit in accordance with the attachedinstruction manual.

4. X24A is connected when the infrared remotecontrol kit is being used.

5. Remote control model varies according to thecombination system, confirm technical materialsand catalogs, etc. before connecting.

6. Symbols show as follows Red:red, Blk:black,Ylw:yellow, Org:orange, Gry:gray, Prp:purple,Blu:blue

7. Confirm the method of setting the selectorswitch (SS1, SS2) by installation manual andengeneering materials, etc.

8. x15A, x25A are connected when the drain up kitis being used. Connect it to the kit in accordancewith the attached installation manual.

Receiver / display unit

Note) 4

Indoor unit(master)

Indoor unit(slave)

Infrared remotecontrol

Emerg.Norm.

Note) 8

Page 12: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

8

� Split Sky Air � Indoor Units 11

� Indoor Units � R-410A � FAQ-BVV1B

8 Wiring diagram8 - 2 External connection diagram

4D044475

V1, ModelPower supply1∼50Hz220V-240V

Main switch

Fuse Fuse

NOTES1 Line voltage wiring

Control circuit wiring2 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes.3 Use copper conductors only.4 See wiring diagrams for details.5 Install fuse and mainswitch for safety.6 All field wiring and components must be provided by a licensed electrician.7 The unit shall be grounded in compilance with the applicable local and national codes.8 Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific

installation.9 Never share a common power supply with other equipment.

V3, ModelPower supply1∼50Hz230V

Main switch

Page 13: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

9

� Split Sky Air � Indoor Units12

9 Sound data9 - 1 Sound level data

Microphone

Model

Sound pressure level

Sound power level230V

Measuring location50Hz

CoolingH/L

HeatingH/L

CoolingH/L

HeatingH/L

FAQ71B 43/37 43/37 45/41 45/41

FAQ100B 59/53 59/53 61/57 61/57

Page 14: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

9

� Split Sky Air � Indoor Units 13

� Indoor Units � R-410A � FAQ-BVV1B

9 Sound data9 - 2 Sound pressure spectrum

4D038512C

Oct

ave

band

soun

dpr

essu

rele

vel

Octave band center frequency (Hz)

FAQ71B (Cooling/Heating)

approximatethreshold hearingfor continuousnoise

H (230V)

L (230V)

Note:1. Sound pressure levels are measured in an anechoic room.2. Data are valid at nominal operation conditions.3. Operation sound level differs with operation and ambient conditions.

4D027787B

FAQ100B (Cooling)

Oct

ave

band

soun

dpr

essu

rele

vel

Octave band center frequency (Hz)

approximatethreshold hearingfor continuousnoise

H (230V)

L (230V)

Note:1. Sound pressure levels are measured in an anechoic room.2. Data are valid at nominal operation conditions.3. Operation sound level differs with operation and ambient conditions.

4D027790B

FAQ100B (Heating)

Oct

ave

band

soun

dpr

essu

rele

vel

Octave band center frequency (Hz)

approximatethreshold hearingfor continuousnoise

H (230V)

L (230V)

Note:1. Sound pressure levels are measured in an anechoic room.2. Data are valid at nominal operation conditions.3. Operation sound level differs with operation and ambient

conditions.

Page 15: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

10

� Split Sky Air � Indoor Units14

10 Air flow pattern

4D039573B

FAQ71B

Cooling - air velocity distribution

Air flow direction: 10° (downward)

FAQ71B

Cooling - air temperature distribution

Air flow direction: 10° (downward)

Page 16: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

3

10

� Split Sky Air � Indoor Units 15

� Indoor Units � R-410A � FAQ-BVV1B

10 Air flow pattern

4D028547B

FAQ100B

Cooling - air velocity distribution

Air flow direction: 10° (downward)

FAQ100B

Cooling - air temperature distribution

Air flow direction: 10° (downward)

Page 17: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

10

� Split Sky Air � Indoor Units16

10 Air flow pattern

4D039574B

FAQ71B

Heating - air velocity distribution

Air flow direction: 65°C (downward)

FAQ71B

Heating - air temperature distribution

Air flow direction: 65°C (downward)

Page 18: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

10

� Split Sky Air � Indoor Units 17

� Indoor Units � R-410A � FAQ-BVV1B

10 Air flow pattern

4D028548B

FAQ100B

Heating - air velocity distribution

Air flow direction: 65°C (downward)

FAQ100B

Heating - air temperature distribution

Air flow direction: 65°C (downward)

Page 19: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

� Indoor Units � R-410A � FAQ-BVV1B

11

� Split Sky Air � Indoor Units18

11 Installation11 - 1 Installation method

Names and functions of partsja Indoor unitjb Outdoor unitjc Infrared remote controljd Inlet airje Discharged airjf Air outletjg Air flow flap (at air outlet)jh Refrigerant piping, connection electric wireji Drain pipejj Air inlet

The built-in air filter removes dust and dirt.jk Ground wire

Wire to ground from the outdoor unit to prevent electrical shocks.

Page 20: technical data - daikintech.co.uk · Ł Indoor Units Ł R-410A Ł FAQ-BVV1B 2 Specifications 2-1 FOR INDOOR UNITS ONLY FAQ71BVV1B FAQ100BVV1B Nominal Input Cooling kW 0.068 0.101

ISO14001 assures an effective environmental management system in order to help protect human•health•and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the•environment.

Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.

Daikin units comply with the Europeanregulations that guarantee the safety ofthe product.

Zandvoordestraat 300B-8400 Ostend - Belgiumwww.daikineurope.com EE

DE0

6-1/

3 •

05/2

006

Prep

ared

in B

elgi

um b

y La

nnoo

The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V..

ÉEEDE06-1/3ÇËÍ

Split - Sky Air

Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products.