Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
SSHS & M-GROUP 316 STAINLESS STEEL END SUCTION PUMPS
BOMBAS DE SUCCIÓN FINAL DE 316 ACERO INOXIDABLE GRUPO-M Y S
TECHNICAL BROCHUREBSSH R6
PAGE 2
Commercial WaterGoulds Water Technology
A FULL RANGE OF PRODUCT FEATURES,UNA GAMA TOTAL DE CARACTERÍSTICAS DEL PRODUCTO
Superior Materials of Construction: AISI Type 316L stainless steel pump parts for reduced corrosion and improved strength and ductility.
Frame Mounted Design: Flexibility of installation and driver arrangements.
Back Pull-Out Design: Simplifies maintenance when used with spacer type coupling.
Cast Iron Power Frame: Rigidly supported, grease lubricated ball bearing assembly.
Sello Mecánico: Sello mecánico estándar John Crane Tipo 21.
Motores de Accionamiento: Motores de armazón-T NEMA estándar unifásicos o trifásicos.
Bridas de Succión y Descarga: Acoplan con bridas ANSI clase 150.
Diseño de Acople Cerrado: El diseño compacto ahorra espacio y simplifica el mantenimiento.
Certificación del NSF 61: Las bombas ensambladas en la fábrica se certifican a los componentes de consumición del circuito de agua de NSF/ANSI 61 estándar.
Materiales Superiores de Construcción: Partes de la bomba de acero inoxidable AISI Tipo 316L para corrosión reducida y fuerza y ductilidad mejoradas.
Diseño de Armazón Montado: Flexibilidad de instalación y colocación del motor.
Diseño de Extracción Trasera: Simplifica el mantenimiento cuando se usa con el acople tipo espaciador.
Armazón del Motor de Hierro Fundido: Rígidamente soportado, con ensamblaje de balineras de bolas lubricadas con grasa .
Mechanical Seal: Standard John Crane Type 21 mechanical seal.
Drive Motors: Standard NEMA design T-frame or JM motors in single or three phase.
Suction and Discharge Flanges: Mate with ANSI class 150 flanges.
Close-Coupled Design: Compact design saves space and simplifies maintenance.
NSF 61 Certification: Pumps assembled at the factory are certified to the NSF/ANSI 61 Drinking Water System Components Standard.
®
DRINKING WATERNSF/ANSI 61 & 372
PAGE 3
Commercial WaterGoulds Water Technology
PERFORMANCE COVERAGE, 3500 AND 1750 RPMALCANCE DE FUNCIONAMIENTO, 3500 Y 1750 RPM
150
125
100
75
50
25
0
40
30
20
10
04003002001000 600
40 60 160 180
500 800
0
1750 RPM
700
20 80 100 120 140
23SH
27SH
22SH
6SH
25SH
24SH
11SH
10SH
9SH
8SH
5SH4SH
28SH
7SH
m3/hr
CAPACITY (CAPACIDAD) – U.S. GPM
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
METERS(METROS)
FEET(PIES)
600
500
400
0
100
75
50
25
04003002001000 600
40 60 160 260 m3/hr
CAPACITY (CAPACIDAD) – U.S. GPM
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
METERS(METROS)
FEET(PIES)
500 800
0
3500 RPM
700
20 80 100 120 140
100
200
300
1000900 12001100
180 200 220 240
125
150
175
23SH
27SH
22SH
6SH5SH
8SH
25SH
24SH
11SH
10SH
7SH
9SH
4SH
28SH
PAGE 4
Commercial WaterGoulds Water Technology
24 SH 1 Q 1 2 A 0 RExample Product Code, Ejemplo Código del Producto
Mechanical Seals and O-Ring0 = Pre-engineered standard For optional mechanical seal modify catalog order no. with seal code listed below.
Casing Rotation, OptionalR = 3 o’clock B = 6 o’clock L = 9 o’clockNOTE: Rotation when viewed from suction end of pump. Standard discharge position is 12 o’clock.
Motor Enclosure, Caja del motor1 = ODP 5 = 3PH, TE PE 9 = 1PH, ODP PE2 = TEFC 6 = 3PH, XP PE A = 1PH, TE PE3 = Explosion Proof, Prueba de explosiones 7 = Wash down, Lavado4 = 3PH, ODP PE 8 = 3PH, WD PE
Motor Voltage, Voltaje del motor1 = 115/208-230 3 = 230 5 = 208-230/460 7 = 5752 = 115/230 4 = 230/460 6 = 460 X = Non Std.
HP Rating, Potencia nominal, HPC = ½ F = 1.5 J = 5 M = 15 Q = 30 T = 60D = .75 G = 2 K = 7.5 N = 20 R = 40 U = 75E = 1 H = 3 L = 10 P = 25 S = 50 V = 100
Driver: Hertz/Pole/RPM, Fuerza motriz: Hertz/Polos/RPM1 = 60/3500/1 3 = 60/1750/1 5 = 50/2900/12 = 60/3500/3 4 = 60/1750/3 6 = 50/2900/3
MaterialSH = 316L Stainless steel, Acero inoxidable
Pump Size, Tamaño de la Bomba9 = 1 x 2 – 6 4 = 1½ x 2½ – 6 8 = 2 x 2½ – 810 = 1 x 2 – 8 7 = 1½ x 2½ – 8 6 = 2½ x 3 – 611 = 1 x 2 – 10 5 = 2 x 2½ – 6 22 = 2½ x 3 – 823 = 3 x 4 – 8 24 = 1½ x 2½ – 10 25 = 2 x 2½ – 1027 = 2½ x 3 – 10 28 = 3 x 4 – 10
SSH S/M-GROUP NUMBERING SYSTEMSISTEMA DE NUMERACIÓN DEL GRUPO-S/M SSH
Impeller Option Code - For optional impeller diameters modify catalog order no. with impeller code listed below. Select optional impeller diameter from pump performance curve. NOTE: For trimmed impellers, use T for impeller code.
NOTE: Impellers will be trimmed in 1/16” increments only. If you are ordering a trim within 1/16” of the standard impeller, you will receive the standard impeller trim.* Indicates impellers that can be trimmed
NOTE: Not all combinations of motor, impeller and seal options are available for every pump model. Please check with GWT on non-cataloged numbers.NOTA: No todas las combinaciones de las opciones de motor, impulsor y sello están disponibles para cada modelo de bombas. Por favor verifique con GWT en los números no catalogados.
Frame Options, Opciones de mando Substitute, Description, Substituto Descripción
FRM2 7/8" Imp. Bore, Diámetro
interior del impulsor 7/8"
FRM3 1¼" Imp. Bore, Diámetro
interior del impulsor 1¼"
Sello Mecánico y Anillo ‘0’0 = Estándar aprobado. Para sello mecánico opcional modificar el número de orden del catálogo con el código del sello anotado abajo.
Rotación de la cubierta, opcionalR = 3 hora B = 6 hora L = 9 horaNOTA: Rotación cuando está visto del extremo de la succión de la bomba. La posición estándar de la descarga es las 12.
Código del Impulsor Opcional - Para diámetros del impulsor opcional modificar el número de orden del catálogo con el código del impulsor anotado abajo. Seleccionar el diámetro del impulsor opcional de la curva de funcionamiento de la bomba. NOTA: Para los impulsores cortados, utilice T para el código del impulsor.
John Crane Type 21 Mechanical Seal, Sello Mecánico John Crane Tipo 21
Seal Code,Código del Sello
Rotary,Rotativo
Stationary,Estacionario
Elastomers,Elastómeros
Metal Parts,Partes Metálicas
Part No., Pieza Número
180-210 Frames, Armazones
250-360 Frames, Armazones
0Carbon Sil-Carb
Viton 316 SS, 316 Acero inoxidable
10K27 10K45
2 EPR 10K19 10K20
5 Sil-Carb Sil-Carb Viton 10K64 10K65
Impeller Code,
Código del impulsor
Pump Size, Tamaño de la Bomba9SH
1 x 2-6 Dia.
10SH 1 x 2-8
Dia.
11SH 1 x 2-10
Dia.
4SH 1½ x 2½-6
Dia.
7SH 1½ x 2½-8
Dia.
5SH 2 x 2½-6
Dia.
8SH 2 x 2½-8
Dia.
*6SH 2½ x 3-6
Dia.
*22SH 2½ x 3 – 8
Dia.
*23SH 3 x 4 – 8
Dia.
24SH 1½ x 2½ –
10 Dia.
25SH 2 x 2½
– 10 Dia.
*27SH 2½ x 3
– 10 Dia.
*28SH 3 x 4 – 10
Dia.A 65⁄8 827⁄64 103⁄32 6¾ 8¼ 67⁄8 8¼ 75⁄16 91⁄16 91⁄16 97⁄8 97⁄8 103⁄8 105⁄8B 67⁄16 81⁄16 917⁄32 63⁄8 713⁄16 67⁄16 7¾ 71⁄8 8¾ 811⁄16 9½ 9½ 915⁄16 10¼C 511⁄16 711⁄16 91⁄8 61⁄16 7 513⁄16 7½ 615⁄16 8½ 87⁄16 93⁄16 91⁄8 99⁄16 913⁄16
D 53⁄8 73⁄8 8¾ 55⁄8 6¾ 5½ 73⁄16 611⁄16 8¼ 81⁄16 87⁄8 813⁄16 9¼ 97⁄16
E 71⁄8 55⁄16 67⁄16 51⁄8 67⁄8 63⁄8 77⁄8 711⁄16 89⁄16 83⁄16 8¾ 91⁄16
F 411⁄16 61⁄8 413⁄16 63⁄16 61⁄16 7½ 7½ 8¼ 715⁄16 811⁄16
G 43⁄8 47⁄16 55⁄8 71⁄8 71⁄8 711⁄16
H 43⁄16 611⁄16 67⁄8J 6½ 6½K 6L 5½
NOTA: Los impulsores serán cortados en 1/16 " incrementos solamente. Si usted está pidiendo un ajuste dentro de 1/16 " del impulsor estándar, usted recibirá el ajuste estándar del impulsor.* Indica los impulsores que pueden ser cortados
PAGE 5
Commercial WaterGoulds Water Technology
PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
1251007550250
0
50
200
10
40
00
20
30
60
150
100
Model SSH / 9SHSize (Tamaño) 1 x 2 - 6 RPM 3500 Curve (Curva) CN0619R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
150
49
54
30252015105
50 8'
10'
39
56 EFF%
A 65/8" DIA.
B 67/16"
C 511/16"
D 53/8"
3 HP
5 HP
5' NPSHR – FEET (PIES)
m3/hr
1251007550250
0
50
300
40
20
30
90
150
100
Model SSH / 10SHSize (Tamaño) 1 x 2 - 8 RPM 3500 Curve (Curva) CN0613R00
200
4025
50
150 175
200
250
60
70
80
3530205 1510
22'18'
14'10'
42
49
47
33
42 EFF%
10 HP
B 81/16"
D 73/8"
C 711/16"
E 71/8"
71/2 HP
A 827/64" DIA.
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6' NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 65⁄8" 5
B 67⁄16 5
C 511⁄16 3
D 53⁄8 3
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 827⁄64" 10
B 81⁄16 10
C 711⁄16 7½
D 73⁄8 7½
E 71⁄8" 7½
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
PAGE 6
Commercial WaterGoulds Water Technology
PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
1251007550250
0
50
450
40
20
30
130
150
100
Model SSH / 11SH
200
40255
50
150 175
200
250
60
70
80
3530201510
400
350
30090
120
110
100
20 HP
15 HP
22’
25'
27'
29'
30
38
43 EFF%
A 103/32" DIA.
B 917/32"
C 91/8"
D 83/4"
45
10 HP
43
Size (Tamaño) 1 x 2 - 10RPM 3500 Curve (Curva) CN0616R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
NPSHR – FEET (PIES)
m3/hr
100500
0
50
125
175
10
40
00
20
30
50
150
100
75
25
150 200 250
5040302010
60
2 HP
3 HP
5 HP
10 HP
71/2 HP
5559
61 6365
65
63
EFF%61
12'
8'
F 411/16"
D 55/8"
B 63/8"
A 63/4" DIA.
G 43/8"
H 43/16"
C 61/16"
E 55/16"
Model SSH / 4SHSize (Tamaño) 11/2 x 21/2 - 6RPM 3500 Curve (Curva) CN0488R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
5’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 103⁄32" 20
B 917⁄32 15
C 91⁄8 15
D 8¾ 15
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 6¾" 10
B 63⁄8 7½
C 61⁄16 7½
D 55⁄8 5
E 55⁄16 5
F 411⁄16 3
G 43⁄8 3
H 43⁄16 2
NOTE: Pump will pass a sphere to 3⁄16" diameter.
NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
PAGE 7
Commercial WaterGoulds Water Technology
PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
60
15075500
0
50
200
250
10
40
00
20
30
50
225
100
75
25
175 200 275
5040302010
27580
125
150
175
70
60
25022512510025
10 HP
71/2 HP
15 HP
5958
EFF%57
56 5758
59
5055
40
D 63/4"
A 81/4" DIA.
E 67/16"
B 713/16"
C 7"
F 61/8"
8'
10'
14'
Model SSH / 7SHSize (Tamaño) 11/2 x 21/2 - 8RPM 3500 Curve (Curva) CN0491R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
4020 100
2000
0
75
125
175
10
40
00
20
30
150
50
250 300
8060
60
50
35015010050
25
100
400
10 HP
15 HP
5 HP
6867
686766
64
60
50
D 51/2"
A 67/8" DIA.
E 51/8"
B 67/16"
C 513/16"
F 413/16"
G 47/16"
10'
14'
19'
EFF%66
71/2 HP
Model SSH / 5SHSize (Tamaño) 2 x 21/2 - 6RPM 3500 Curve (Curva) CN0494R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 8¼" 15
B 713⁄16 15
C 7 10
D 6¾ 10
E 67⁄16 7½
F 61⁄8 7½
NOTE: Pump will pass a sphere to 3⁄16" diameter.
NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 67⁄8" 15
B 67⁄16 15
C 513⁄16 10
D 5½ 10
E 51⁄8 7½
F 413⁄16 7½
G 47⁄16 5
NOTE: Pump will pass a sphere to 3⁄16" diameter.
NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
PAGE 8
Commercial WaterGoulds Water Technology
PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
4020 100
2000
0
150
250
10
40
00
20
30
200
50
250 300
8060
30090
50
35015010050
100
400
80
70
60
A 81/4" DIA.
E 67/8"
B 73/4"
F 63/16"
C 71/2"
D 73/16"
15 HP20 HP
25 HP
10 HP
69
EFF%65
71
71
69656050 10'
13'
16'
21'
Model SSH / 8SHSize (Tamaño) 2 x 21/2 - 8RPM 3500 Curve (Curva) CN0497R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
8’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 8¼" 25
B 7¾ 20
C 7½ 20
D 73⁄16 15
E 67⁄8 15
F 63⁄16 10
NOTE: Pump will pass a sphere to ¼" diameter.
NOTA: La bomba pasará una esfera a ¼" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 75⁄16" 25
B 71⁄8 25
C 615⁄16 20
D 611⁄16 20
E 63⁄8 15
F 61⁄16 15
G 55⁄8 10
NOTE: Pump will pass a sphere to 5⁄16" diameter.
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
5025 150
3000
0
150
250
10
40
00
20
30
200
50
400 500
75
80
50
600200100
100
700
70
60
E 63/8"
A 75/16" DIA.
F 61/16"
B 71/8"C 615/16"
G 55/8"
60
65
7070
68
8'
10'
13'
66
EFF%60
15'
6520'
10 HP
20 HP
25 HP
125100 175
D 611/16"
63
15 HP
25'
Model SSH / 6SHSize (Tamaño) 21/2 x 3 - 6RPM 3500 Curve (Curva) CN0500R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
7’ NPSHR – FEET (PIES)
m3/hr
PAGE 9
Commercial WaterGoulds Water Technology
PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM
50403020100
10
0
20
80
6'
50
55 EFF%
A 65/8" DIA.
B 67/16"
C 511/16"
D 53/8"30
40
50
60 70
4'55
565'
8'
1/2 HP
3/4 HP
Model SSH / 9SHSize (Tamaño) 1 x 2 - 6RPM 1750 Curve (Curva) CN0620R00
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
NPSHR – FEET (PIES)
504030201000
70
40
30
8060 70
50
60
8'47
49 EFF%
20
10
1 HP
A 827/64" DIA.
C 711/16"
B 81/16"
E 71/8"
D 73/8"
3/4 HP
11/2 HP
5'42
6'
Model SSH / 10SHSize (Tamaño) 1 x 2 - 8RPM 1750 Curve (Curva) CN0614R00
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
4’ NPSHR – FEET (PIES)
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 65⁄8" ¾
B 67⁄16 ¾
C 511⁄16 ½
D 53⁄8 ½
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 827⁄64" 1½
B 81⁄16 1½
C 711⁄16 1
D 73⁄8 ¾
E 71⁄8 ¾
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
PAGE 10
Commercial WaterGoulds Water Technology
PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM
502500
120
40
20
10075
60
100
80
2 HP
12' 14'
17'
36
43 EFF%
A 103/32 "
B 917/32"
C 91/8"
D 83/4"
45
1.5 HP
43
38
3 HP
8'
Model SSH / 11SHSize (Tamaño) 1 x 2 - 10RPM 1750 Curve (Curva) CN0617R00
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H
)
CAPACITY (CAPACIDAD) (Q)U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
NPSHR – FEET (PIES)
30
800
0
30
10
00
40
20
100 120
25201510
15
F 411/16"
D 55/8"
C 61/16"
A 63/4" DIA.
G 43/8"H 43/16"
5459
62
62
61
EFF%60
6'
10
604020
5
5
8'
1/2 HP
1 HP
3/4 HP
B 63/8"
E 55/16"
60 61
Model SSH / 4SHSize (Tamaño) 11/2 x 21/2 - 6RPM 1750 Curve (Curva) CN0489R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
4’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 103⁄32" 3
B 917⁄32 3
C 91⁄8 2
D 8¾ 2
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 6¾" 1
B 63⁄8 1
C 61⁄16 1
D 55⁄8 ¾
E 55⁄16 ¾
F 411⁄16 ½
G 43⁄8 ½
H 43⁄16 ½
NOTE: Pump will pass a sphere to 3⁄16" diameter.
NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
PAGE 11
Commercial WaterGoulds Water Technology
PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM
30
80600
0
40
00
25201510
20
15
10
12020
5756
EFF%55
54 5556
57
4853
38
D 63/4"
E 67/16"
B 713/16"
C 7"
F 61/8"
10'
13'
20
5
5
10040
8'
2 HP
1 HP
60
A 81/4" DIA.
Model SSH / 7SHSize (Tamaño) 11/2 x 21/2 - 8RPM 1750 Curve (Curva) CN0492R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.
NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
11/2 HP
30
0
0
40
10
00
30
120
5040
160
20
200
1 HP
6766
65
676665
63
58
48
D 51/2"
A 67/8" DIA.
E 51/8"
B 67/16"
C 513/16"
F 413/16"
G 47/16"
12'
10
40 80
10 20
5
7'
9'
2 HP
11/2 HP
3/4 HP
EFF%
Model SSH / 5SHSize (Tamaño) 2 x 21/2 - 6RPM 1750 Curve (Curva) CN0495R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
4’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia A 8¼" 2
B 713⁄16 2
C 7 1½
D 6¾ 1½
E 67⁄16 1
F 61⁄8 1
NOTE: Pump will pass a sphere to 3⁄16" diameter.
NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 67⁄8" 2
B 67⁄16 2
C 513⁄16 1½
D 5½ 1½
E 51⁄8 1
F 413⁄16 1
G 47⁄16 ¾
NOTE: Pump will pass a sphere to 5⁄32" diameter.
NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
PAGE 12
Commercial WaterGoulds Water Technology
30
0
0
10
00
20
50
120
5040
16080 200
67
69
A 81/4" DIA.
E 67/8"
B 73/4"
F 63/16"
C 71/2"
D 73/16"
EFF%
69
6763
5848
11'
40
30
20
10
60
40
10 20
5
15
7'
9'
3 HP
2 HP11/2 HP
Model SSH / 8SHSize (Tamaño) 2 x 21/2 - 8RPM 1750 Curve (Curva) CN0498R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
5’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 8¼" 3
B 7¾ 3
C 7½ 2
D 73⁄16 2
E 67⁄8 1½
F 63⁄16 1½
NOTE: Pump will pass a sphere to 5⁄32" diameter.
NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
5025
3000
0
10
00
50
400
75
20
200100
E 63/8"
A 75/16" DIA.
F 61/16"
C 615/16"
G 55/8"
57
62
6767
65
5'
63
EFF%57
11'
6215'
60
2 HP
19'
7'
9'
11/2 HP
3 HP
B 71/8"
D 611/16"
60
40
30
20
10
15
5
Model SSH / 6SHSize (Tamaño) 21/2 x 3 - 6RPM 1750 Curve (Curva) CN0502R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
4’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 75⁄16" 3
B 71⁄8 3
C 615⁄16 3
D 611⁄16 3
E 63⁄8 2
F 61⁄16 2
G 55⁄8 1½
NOTE: Pump will pass a sphere to 5⁄16" diameter.
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM
PAGE 13
Commercial WaterGoulds Water Technology
1007550250 1501250
250
150
100
200
49 EFF%
50
A 827/64" DIA.
D 73/8"
E 71/8"
C 711/16"
B 81/16"
7' 42
12’
47
3 HP
5 HP
9’
Model SSH / 10SHSize (Tamaño) 1 x 2 - 8RPM 2900 Curve (Curva) CN0615R00
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
5’ NPSHR – FEET (PIES)
402000
20
80
40A 65/8" DIA.
B 67/16"
C 511/16"
D 53/8"
60
40
120
60 100
80
100
120
50
7'55 EFF%
3 HP
2 HP1/2 HP
56
55
4'
Model SSH / 9SHSize (Tamaño) 1 x 2 - 6RPM 2900 Curve (Curva) CN0621R00
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
5’ NPSHR – FEET (PIES)
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 65⁄8" 3
B 67⁄16 3
C 511⁄16 2
D 53⁄8 2
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 827⁄64" 5
B 81⁄16 5
C 711⁄16 5
D 73⁄8 5
E 71⁄8 3
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
PAGE 14
Commercial WaterGoulds Water Technology
50250
300
100
5017575
250
8’
14’18'
20'
30
43 EFF%
A 103/32" DIA.
B 917/32"
C 91/8"
D 83/4"
45
43
38
100 125 150
150
200
10 HP
71/2 HP
Model SSH / 11SHSize (Tamaño) 1 x 2 - 10RPM 2900 Curve (Curva) CN0618R00
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H
)
CAPACITY (CAPACIDAD) (Q)U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
NPSHR – FEET (PIES)
50
120800
0
60
120
10
00
20
30 100
80
40
160 200
40302010
40
20
40
1 HP
5 HPF 411/16"
D 55/8"
C 61/16"
B 63/8"
A 63/4" DIA.
G 43/8"H 43/16"
5560
61 6264
64
62
EFF%61
6'
8'
2 HP
3 HP
E 55/16"
Model SSH / 4SHSize (Tamaño) 11/2 x 21/2 - 6RPM 2900 Curve (Curva) CN0490R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
4’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 103⁄32" 15
B 917⁄32 10
C 91⁄8 10
D 8¾ 7½
NOTE: Pump will pass a sphere to 1⁄8" diameter.
NOTA: La bomba pasará una esfera a 1⁄8" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 6¾" 5
B 63⁄8 5
C 61⁄16 5
D 55⁄8 3
E 55⁄16 3
F 411⁄16 2
G 43⁄8 2
H 43⁄16 1½
NOTE: Pump will pass a sphere to 3⁄16" diameter.
NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
PAGE 15
Commercial WaterGoulds Water Technology
50
12080400
0
40
200
10
40
00
20
30
50
80
160 200
40302010
60
120
160
71/2 HP
10 HP
5857
EFF%56
55 5657
58
4954
39
D 63/4"
A 81/4" DIA.
E 67/16"
B 713/16"
C 7"
F 61/8"
13'
17'
8'
5 HP
Model SSH / 7SHSize (Tamaño) 11/2 x 21/2 - 8RPM 2900 Curve (Curva) CN0493R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EAD
(CA
RGA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
40
2000
0
80
120
10
00
20
30
60
280 320
8060
40
36016080
40
100
20
71/2 HP
3 HP
6867
EFF%66
686766
64
59
49
D 51/2"
A 67/8" DIA.
E 51/8"
B 67/16"
C 513/16"
F 413/16"
G 47/16"
10'
14'
24012040
7050302010
7'
10 HP
5 HP
Model SSH / 5SHSize (Tamaño) 2 x 21/2 - 6RPM 2900 Curve (Curva) CN0496R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
5’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 8¼" 10
B 713⁄16 7½
C 7 7½
D 6¾ 7½
E 67⁄16 5
F 61⁄8 5
NOTE: Pump will pass a sphere to 3⁄16" diameter.
NOTA: La bomba pasará una esfera a 3⁄16" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 67⁄8" 10
B 67⁄16 7½
C 513⁄16 7½
D 5½ 5
E 51⁄8 5
F 413⁄16 3
G 47⁄16 3
NOTE: Pump will pass a sphere to 5⁄32" diameter.
NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
PAGE 16
Commercial WaterGoulds Water Technology
40
2000
0
160
10
40
00
20
30
80
240 280
8060
50
32016012080
120
360
EFF%
A 81/4" DIA.
E 67/8"
B 73/4"
C 71/2"
D 73/16"
10 HP
68
64
70
71
70
68645949
13'
16'
40
40
10 20 30 50 70
7'
9'
15 HP
71/2 HP
F 63/16"
Model SSH / 8SHSize (Tamaño) 2 x 21/2 - 8RPM 2900 Curve (Curva) CN0499R01
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 8¼" 15
B 7¾ 15
C 7½ 10
D 73⁄16 10
E 67⁄8 7½
F 63⁄16 7½
NOTE: Pump will pass a sphere to 5⁄32" diameter.
NOTA: La bomba pasará una esfera a 5⁄32" diámetro.
5025
3000
0
150
10
40
00
20
30
50
400 500
75
50
600200100
100
125100
25
75
125
175
E 63/8"
A 75/16" DIA.
F 61/16"
C 615/16"
G 55/8"
58
64
6969
67
7'
11'
65
62
EFF%58
13'17'
21'
10 HP
15 HP
D 611/16"
B 71/8"
64
8'
71/2 HP
Model SSH / 6SHSize (Tamaño) 21/2 x 3 - 6RPM 2900 Curve (Curva) CN0501R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 75⁄16" 15
B 71⁄8 15
C 615⁄16 15
D 611⁄16 10
E 63⁄8 10
F 61⁄16 7½
G 55⁄8 7½
NOTE: Pump will pass a sphere to 5⁄16" diameter.
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
PAGE 17
Commercial WaterGoulds Water Technology
20
200150100500
0
EFF
0
40
70
250
40 60
50
100
150
250
300
60
50
30
20
300
200
350
400
450
100
90
80
400350 450 500
80 100
130
120
110
10
55%60
11'
20'
6263
64
6463
9'B 9 1/2"
C 91/8"
D 813/16"
E 83/16"F 715/16"G 711/16"
A 9 7/8" DIA.
30 HP
25 HP
40 HP
50 HP
Model SSH / 25SHSize (Tamaño) 2 x 21/2 - 10RPM 3500 Curve (Curva) CN0506R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
7’ NPSHR – FEET (PIES)
m3/hr
20
200150100500
0
0250
40 60
50
100
150
250
300
300
200
350
400
450
50%
5759
59
8'
10'
12'
55
25 HP
7
B 9 1/2"
C 93/16"
D 87/8"
E 89/16"
F 8 1/4"
40
70
60
50
30
20
100
90
80
130
120
110
10
EFF55
30 HP
A 9 /8" DIA.
60
20 HP
Model SSH / 24SHSize (Tamaño) 11/2 x 21/2 - 10RPM 3500 Curve (Curva) CN0503R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 97⁄8" 50
B 9½ 40
C 91⁄8 40
D 813⁄16 30
E 83⁄16 30
F 715⁄16 25
G 711⁄16 25
NOTE: Pump will pass a sphere to ½" diameter.
NOTA: La bomba pasará una esfera a ½" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 97⁄8" 30
B 9½ 30
C 93⁄16 25
D 87⁄8 25
E 89⁄16 20
F 8¼ 20
NOTE: Pump will pass a sphere to 5⁄16" diameter.
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
PAGE 18
Commercial WaterGoulds Water Technology
50
0
6005004003002001000
B 8 3/4"A 9 1/16" DIA.
D 8 1/4"
50
100
700
40 180
E 7 7/8"
60 HP
8'
75
300
70
60
40
30
20
F 7 1/2"50 HP
C 8 1/2"
800
60 80 100 120 140
70
71
68
65
5060
40% EFF350
325
275
250
225
200
175
150
125
100
80
90
160
H 6 11/16"
G 7 1/8"
J 61/2"
10'12'
15'
68
65
20'25'
30'
60
40 HP
30 HP25 HP20 HP
15 HP
Model SSH / 22SHSize (Tamaño) 21/2 x 3 - 8RPM 3500 Curve (Curva) CN0509R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
7’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 91⁄16" 60
B 8¾ 50
C 8½ 50
D 8¼ 40
E 77⁄8 40
F 7½ 30
G 71⁄8 25
H 611⁄16 20
J 6½ 20
NOTE: Pump will pass a sphere to 19⁄32" diameter.
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
0
20
6005004003002001000
0
B 9 15/16"
A 103/8" DIA.
D 9 1/4"
50
175
700
40 180
E 8 3/4"
100 HP
50
300
75
25
0
C 9 9/16"
800
60 80 100 120 140
5545% EFF
600
250
200
150
100
160
550
500
450
400
350100
125
150
75 HP
60 HP50 HP
40 HP
6065
69
6970
8'10'
12'15'
20'30'
65
Model SSH / 27SHSize (Tamaño) 21/2 x 3 - 10RPM 3500 Curve (Curva) CN0512R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
7’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 103⁄8" 100
B 915⁄16 75
C 99⁄16 75
D 9¼ 60
E 8¾ 50
NOTE: Pump will pass a sphere to 19⁄32" diameter.
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
PAGE 19
Commercial WaterGoulds Water Technology
0
40
120010008006004002000
0
D 97/16"
C 9 13/16" DIA.
F 8 11/16"
50
175
1400
80 360
100 HP
50
0
10'
E 9 1/16"
1600
120 160 200 240 280
5545% EFF
600
250
200
150
320
300
100
75
25
550
500
450
400
350
150
125
100
65 7073
75
75
7676
73
12'14'
17'20'
25'
30'
75 HP
60 HP
Model SSH / 28SHSize (Tamaño) 3 x 4 - 10RPM 3500 Curve (Curva) CN0518R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
8’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
C 913⁄16" 100
D 97⁄16 100
E 91⁄16 75
F 811⁄16 75
NOTE: Pump will pass a sphere to ¾" diameter.
NOTA: La bomba pasará una esfera a ¾" diámetro.
50
40
120010008006004002000
0
B 8 11/16"
A 9 1/16" DIA.
D 8 1/16"
50
100
1400
80 360
E 7 11/16"
75 HP
75
325
90
40
20
10'
C 8 7/16"
1600
120 160 200 240 280
6050% EFF
350
275
250
200
150
320
300
225
175
125
100
80
70
60
30
F 7 1/2"
G 7 1/8"
H 67/8"
J 6 1/2"
14'
17'
20'
25'
30'
70
7577
77
75
7878
70
60 HP
50 HP
40 HP30 HP25 HP
K 6"
L 5 1/2"
20 HP15 HP
100 HP
Model SSH / 23SHSize (Tamaño) 3 x 4 - 8RPM 3500 Curve (Curva) CN0515R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.
NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
12’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 91⁄16" 75
B 811⁄16 75
C 87⁄16 60
D 81⁄16 50
E 711⁄16 50
F 7½ 40
G 71⁄8 40
H 67⁄8 30
J 6½ 25
K 6 20
L 5½ 15
NOTE: Pump will pass a sphere to ¾" diameter.
NOTA: La bomba pasará una esfera a ¾" diámetro.
PERFORMANCE CURVES – 60 HZ, 3500 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 3500 RPM
PAGE 20
Commercial WaterGoulds Water Technology
0 10
504030200
EFF
0100
20
10
20
30
50
60
30
20
150
40
70
100
110
80
90
10 90807060 110 120 130 140
45%
50 5254
54
56
4'
5'
50
3 HP
2 HP
25
15
10
5
5 15 25 30
52
B 9 1/2"
C 93/16"
D 8 7/8"
E 89/16"
F 8 1/4"
A 9 7/8" DIA.
Model SSH / 24SHSize (Tamaño) 11/2 x 21/2 - 10RPM 1750 Curve (Curva) CN0505R00
METERSMETROS
FEETPIES
TO
TA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H
)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
3’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 97⁄8" 5
B 9½ 5
C 93⁄16 3
D 87⁄8 3
E 89⁄16 3
F 8¼ 2
NOTE: Pump will pass a sphere to 5⁄16" diameter.
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
10
806040200
0
EFF
100
15 20
120
25
0
10
20
30
50
60
40
70
100
110
80
90
140 160 180 200 220 240
30
20
25
15
10
5
5 30 35 40 45 50 55
50%55
5'
8'
5758
59
5958
3 HP
5 HP
7.5 HP
B 9 1/2"
C 91/8"
D 813/16"
E 83/16"F 715/16"G 711/16"
A 9 7/8" DIA.
Model SSH / 25SHSize (Tamaño) 2 x 21/2 - 10RPM 1750 Curve (Curva) CN0508R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
4’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 97⁄8" 7½
B 9½ 5
C 91⁄8 5
D 813⁄16 5
E 83⁄16 3
F 715⁄16 3
G 711⁄16 3
NOTE: Pump will pass a sphere to ½" diameter.
NOTA: La bomba pasará una esfera a ½" diámetro.
PERFORMANCE CURVES – 60 HZ, 1750 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1750 RPM
PAGE 21
Commercial WaterGoulds Water Technology
0
20
300250200150100500
0
C 8 1/2"
A 9 1/16" DIA.
E 7 7/8"
10
35
350
30 100
10
0
D 8 1/4"
400
40 50 60 70 80
5040% EFF
120
90
15
5
110
10030
25
20
7 1/2 HP20
30
40
50
60
70
80
90
450
10
G 7 1/8"
H 6 11/16"
5560 62
6260
64
55
50
6'
8'
10'
15'
5 HP3 HP
2 HP
Model SSH / 22SHSize (Tamaño) 21/2 x 3 - 8RPM 1750 Curve (Curva) CN0511R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
5’ NPSHR – FEET (PIES)
m3/hr
0
20
300250200150100500
0
B 9 15/16"
A 103/8" DIA.
D 9 1/4"
10
35
350
30 100
10
0
C 9 9/16"
400
40 50 60 70 80
5550% EFF
120
90
15
5
110
10030
25
20
5'
7 1/2 HP
20
30
40
50
60
70
80
90
450
10
E 8 3/4"
5 HP
6063
63
66
66
68
68
55
60
7'
15'
20'
10'
10 HP
15 HP
Model SSH / 27SHSize (Tamaño) 21/2 x 3 - 10RPM 1750 Curve (Curva) CN0514R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 91⁄16" 7½
C 8½ 7½
D 8¼ 5
E 77⁄8 5
G 71⁄8 3
H 611⁄16 3
NOTE: Pump will pass a sphere to 19⁄32" diameter.
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 103⁄8" 15
B 915⁄16 10
C 99⁄16 10
D 9¼ 7½
E 8¾ 7½
NOTE: Pump will pass a sphere to 19⁄32" diameter.
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
PERFORMANCE CURVES – 60 HZ, 1725 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1725 RPM
PAGE 22
Commercial WaterGoulds Water Technology
0
40
6005004003002001000
0
C 8 7/16"
A 9 1/16" DIA.
F 7 1/2"
10
35
700
60 200
10
0
D 81/16"
800
80 100 120 140 160
5545% EFF
120
180
15
5
110
10030
25
20
7 1/2 HP20
30
40
50
60
70
80
90
900
20
G 7 1/8"
3 HP
J 6 1/2"
6568
71
73
73
74
71
6'8'
10'
6865
55
15'
5 HP
10 HP
Model SSH / 23SHSize (Tamaño) 3 x 4 - 8RPM 1750 Curve (Curva) CN0517R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.
NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
5’ NPSHR – FEET (PIES)
m3/hr
10
20
0
6005004003002001000
B 101/4"
A 105/8" DIA.
D 9 7/16"
40
700
60 200
C 9 13/16"
800
80 100 120 140 160
5545% EFF
180
15
130
120
30
25
20
30
40
50
60
70
80
90
900
20
10 HP
110
100
35
6570
15 HP
20 HP
73
73
74
70
65
8'
10'
15'20'
30'
Model SSH / 28SHSize (Tamaño) 3 x 4 - 10RPM 1750 Curve (Curva) CN0520R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
7’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 91⁄16" 10
C 87⁄16 7½
D 81⁄16 7½
F 7½ 5
G 71⁄8 5
J 6½ 3
NOTE: Pump will pass a sphere to ½" diameter.
NOTA: La bomba pasará una esfera a ½" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 105⁄8" 20
B 10¼ 15
C 913⁄16 15
D 97⁄16 15
NOTE: Pump will pass a sphere to ¾" diameter.
NOTA: La bomba pasará una esfera a ¾" diámetro.
PERFORMANCE CURVES – 60 HZ, 1725 RPMCURVAS DE FUNCIONAMIENTO – 60 HZ, 1725 RPM
PAGE 23
Commercial WaterGoulds Water Technology
20
200120100400
0
EFF
0
40
70
220
40
50
100
150
250
300
60
50
30
20
240
200
48%53 55
57
57
58
6'
8'
10'
53
A 9 7/8" DIA.
B 9 1/2"
C 93/16"
D 87/8"
E 89/16"
F 8 1/4"
90
80
140 160 180806020
10
10 30 50
55
15 HP
10 HP
20 HP
Model SSH / 24SHSize (Tamaño) 11/2 x 21/2 - 10RPM 2900 Curve (Curva) CN0504R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
3’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 97⁄8" 20
B 9½ 15
C 93⁄16 15
D 87⁄8 15
E 89⁄16 10
F 8¼ 10
NOTE: Pump will pass a sphere to ½" diameter.
NOTA: La bomba pasará una esfera a ½" diámetro.
20
400
0
EFF
40 60 80
0
50
100
150
250
300
200
80 120 160 200 240 280 320 360 400
40
70
60
50
30
20
90
80
10
20 HP15 HP
25 HP
30 HP
53%58
10'
17'
6061
62
6261
8'B 9 1/2"
C 91/8"
D 813/16"
E 83/16"F 715/16"G 711/16"
A 9 7/8" DIA.
Model SSH / 25SHSize (Tamaño) 2 x 21/2 - 10RPM 2900 Curve (Curva) CN0507R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H
)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 97⁄8" 30
B 9½ 25
C 91⁄8 20
D 813⁄16 20
E 83⁄16 15
F 715⁄16 15
G 711⁄16 15
NOTE: Pump will pass a sphere to 5⁄16" diameter.
NOTA: La bomba pasará una esfera a 5⁄16" diámetro.
PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
PAGE 24
Commercial WaterGoulds Water Technology
0
0
6005004003002001000
B 8 3/4"A 9 1/16" DIA.
D 8 1/4"
50
700
40 140
E 7 7/8"
75
70
60
40
30
10
F 7 1/2"
C 8 1/2"
60 80 100 120
5040% EFF
250
225
200
175
150
125
100
H 6 11/16"
G 71/8"
J 61/2"
50
20
60
65
6567
68
60
50
7' 8'10'
12' 15'
18'
20'
40 HP
30 HP
25 HP20 HP
15 HP
10 HP
Model SSH / 22SHSize (Tamaño) 21/2 x 3 - 8RPM 2900 Curve (Curva) CN0510R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
0
20
6005004003002001000
0
B 9 15/16"
A 103/8" DIA.
D 91/4"
50
700
40 140
E 8 3/4"
50
300
75
25
0
C 9 9/16"
60 80 100 120
45% EFF
250
200
150
100
400
350
100
25 HP
5560
6568
30 HP
40 HP
50 HP
6869
65
8'10'
12'15'
20'
Model SSH / 27SHSize (Tamaño) 21/2 x 3 - 10RPM 2900 Curve (Curva) CN0513R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
6’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 91⁄16" 40
B 8¾ 30
C 8½ 30
D 8¼ 25
E 77⁄8 20
F 7½ 20
G 71⁄8 15
H 611⁄16 15
J 6½ 15
NOTE: Pump will pass a sphere to 19⁄32" diameter.
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 103⁄8" 50
B 915⁄16 40
C 99⁄16 40
D 9¼ 30
E 8¾ 30
Pump will pass a sphere to 19⁄32" diameter.
NOTA: La bomba pasará una esfera a 19⁄32" diámetro.
PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
PAGE 25
Commercial WaterGoulds Water Technology
0
40
120010008006004002000
0
B 8 11/16"
A 9 1/16" DIA.
D 8 1/16"
50
1400
80 280
E 7 11/16"
50
20060
40
9'
C 8 7/16"
120 160 200 240
50% EFF
175
150
100
250
225
70
50 HP
60
75
30
20
10
125
F 7 1/2"
G 7 1/8"
H 67/8"
J 61/2"
7072
12'
15'
72
74
74
76
7620'
70
40 HP
30 HP25 HP
20 HP15 HP
Model SSH / 23SHSize (Tamaño) 3 x 4 - 8RPM 2900 Curve (Curva) CN0516R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EAD
(CA
RGA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
10’ NPSHR – FEET (PIES)
m3/hr
0
40
120010008006004002000
0
D 97/16"
C 9 13/16" DIA.
F 8 11/16"
50
1400
80 280
50
300
75
25
0
E 9 1/16"
120 160 200 240
50% EFF
250
200
150
100
400
350
100
30 HP
6065
70
73
73
7575
9' 10'12'
14'
17'
20'
40 HP
50 HP
60 HP
Model SSH / 28SHSize (Tamaño) 3 x 4 - 10RPM 2900 Curve (Curva) CN0519R00
METERSMETROS
FEETPIES
TOTA
L D
YN
AM
IC H
EA
D (C
AR
GA
DIN
AM
ICA
TO
TAL)
(H)
CAPACITY (CAPACIDAD) (Q)
U.S. GPM
NOTE: Not recommended for operation beyond printed H-Q curve.NOTA: No se recomienda para funcionamiento superior al impreso en la curva H-Q.
8’ NPSHR – FEET (PIES)
m3/hr
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
A 91⁄16" 50
B 811⁄16 40
C 87⁄16 40
D 81⁄16 30
E 711⁄16 30
F 7½ 25
G 71⁄8 20
H 67⁄8 20
J 6½ 15
NOTE: Pump will pass a sphere to ½" diameter.
NOTA: La bomba pasará una esfera a ½" diámetro.
Optional Impeller,Impulsor Opcional
Impeller Standard Code, Dia., HP Rating, Código del Diá. Estándar HP Impulsor Potencia
C 913⁄16" 60
D 97⁄16 50
E 91⁄16 50
F 811⁄16 40
NOTE: Pump will pass a sphere to ¾" diameter.
NOTA: La bomba pasará una esfera a ¾" diámetro.
PERFORMANCE CURVES – 50 HZ, 2900 RPMCURVAS DE FUNCIONAMIENTO – 50 HZ, 2900 RPM
PAGE 26
Commercial WaterGoulds Water Technology
SSH FRAME MOUNTED – MATERIALS OF CONSTRUCTIONSSH ARMAZÓN MONTADO – MATERIALES DE CONSTRUCCIÓN
SSH CLOSE COUPLED – MATERIALS OF CONSTRUCTIONSSH ACOPLE CERRADO – MATERIALES DE CONSTRUCCIÓN
Item No., Description, Materials, Parte No. Descripción Materiales
100 Casing, Carcasa
101 Impeller, Impulsor
103 Wear ring, Anillo de desgaste 316L SS, 316L acero inox.
184 Seal housing, Alojamiento del sello
126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.
422 Impeller stud, Perno del impulsor Steel, Acero
178 Impeller key, Carbon steel,
Llave del impulsor Acero al carbono
199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.
Casing bolt with nut (casing to adapter), 316L SS,
370 Tornillo de la carcasa con tuerca
316L acero inoxidable (carcasa para adaptador)
Cast iron ASTM A48 CL20, 108 Adapter, Adaptador Hierro fundido ASTM A48CL20
Hex head cap screw (adapter to motor), Steel SAE 1200 series,371 Tornillo de cabeza hexagonal Acero SAE series 1200 (adaptador para motor)
412A O-ring, Impeller, Anillo en O, impulsor
412F O-ring, shaft sleeve, Anillo en O, camisa del eje Viton
513 O-ring, Anillo 'O'
408 Drain plug – 3⁄8 BSP, 316L SS,
Válvula de drenaje – 3⁄8 BSP 316 acero inoxidable
383 Mechanical seal, See seal chart,
Sello mecánico Ver tabla del sello
Item No., Description, Materials, Parte No. Descripción Materiales
100 Casing, Carcasa
101 Impeller, Impulsor 316L SS,
103 Wear ring, Anillo de desgaste 316L acero inox.
184 Seal housing, Alojamiento del sello
126 Shaft sleeve, Camisa del eje 316 SS, 316 acero inox.
178 Impeller key, Llave del impulsor Carbon steel,422 Impeller Stud, Perno del impulsor Acero al carbono
199 Impeller washer, Arandela del impulsor 316 SS, 316 acero inox.
370 Casing bolt with nut, Tornillo de la carcasa con tuerca 316L SS,
408 Drain plug – 3⁄8 NPT, Válvula de drenaje – 3⁄8 NPT 316L acero inox.
513 O-ring, Anillo ‘O’ Viton
383 Mechanical seal, See seal chart, Sello mecánico Ver tabla del sello
108 Adapter, Adaptador
228 Bearing frame, Armazón de balineras
134 Bearing cover, Cubierta de balineras
122 Pump shaft, Carbon steel, Eje de la bomba Acero al carbono
168 Ball bearing (inboard), Balineras de bolas (interior)
112 Ball bearing (outboard), Balineras de bolas (exterior)
382 Retaining ring, Anillo de sujeción
Hex head cap screw (adapter to bearing frame),370B Tornillo de cabeza hexagonal Steel, Acero (adaptador para armazón de balineras)
Hex head cap screw (bearing frame to cover), 370C Tornillo de cabeza hexagonal (armazón de balineras para cubierta)
333A Lip seal, Sello cubierto BUNA-N
193 *Greasefitting,Accesorio de grasa Steel, Acero
123 V-ringdeflector,Deflector anillo ‘V’ BUNA-N
* M-Group only
Part No.,Pleza Número
10K19 10K20
EPR
Hot Water, 383 Carbon, Silicon 316 SS, Agua Caliente Options,
10K27 10K45 Carbone Carbide, 316 Mild Abrasive,
383 Carburo de Viton
Acero Abrasivo Suave Opciones
10K64 10K65 Sil-Carb. silicona inoxidable Severe Duty,
Deber Severo
Mechanical Seal, Sello Mecánico
John Crane Type 21 Mechanical Seal,Sello Mecánico John Crane Tipo 21
Item, Rotary, Stationary, Elastomers, Parte Rotativo Estacionario Elastómeros
Cast iron ASTM A48CL20,Hierro fundido ASTM A48CL20
Metal Intended Parts, Duty, Partes Servicio Metálicas Propuesto
103 199 422 408 178
100 101 178 108 370
513
199 422 408 126 371412F
184
383412A
103
383100 101 513 370 184 108 228
126370B 123 168 112 122382
134
370C
333A
412F
412A
180-210 250-360 Frames, Frames, Armazones Armazones
PAGE 27
Commercial WaterGoulds Water Technology
SSH – ENGINEERING DATA S-GROUPSSH – INFORMACIÓN TÉCNICA GRUPO-SChannel Steel Bedplate, Clockwise Rotation Viewed from Drive End;Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor
NOTES:1. All pumps shipped in vertical
discharge position. May be ro-tated in 90° increments. Tighten 3⁄8 – 16 casing bolts to 20 ft./lbs. torque.
2. Dimensions in inches.3. Motor dimensions may vary with
motor manufacturer.4. Not to be used for construction
purposes.
NOTAS:1. Todas las bombas transportadas
en posición de descarga vertical. Pueden rotarse en aumentos de 90º. Apretar 3⁄8 – 16 tornillos de carcasa a 20 pies/libras potencia.
2. Las dimensiones en pulgadas.3. Las dimensiones puede que varíen
con los fabricantes..4. No para propósitos de construcción.
MotorFrame,
Armazóndel
Motor
Available Motor and Bedplate Dimensions and Weights,Pesos y Dimensiones Disponibles de la Fundación y del Motor
ODP*** TEFC*** ODP*** TEFC*** ODP*** TEFC*** ODP*** TEFC***
Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs.* “HP” Dimensions at motor end only.** “HD” Dimension for 254T/256T motor frame on 1 x 2-10 only is 11"; A ¾" motor shim and a 1¾" bearing frame shim are required.*** Premium efficiency where required by Department of Energy regulations.
Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras.* Dimensiones “HP” sólo en el extremo del motor.** La dimensión “HD” para el bastidor del motor 254T/256T de 1 x 2 - 10 es sólo 11"; se requieren una cuña del motor de ¾" y una cuña del bastidor de apoyo de 1¾".*** Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.
HP @ 3500 RPM, HP @ 1750 RPM, Bedplate Data, Datos de la Fundación HP a 3500 RPM HP a 1750 RPM
Single Phase, Three Phase, Single Phase, Three Phase, Monofásicos Trifásicos Monofásicos Trifásicos
SUCTIONSUCCIÓN
DISCHARGEDESCARGA
3⁄8" – 19 BSP
KEYWAY 1⁄8 x ¼CHAVETERO 1⁄8 x ¼
HP
SPACER COUPLINGACOPLE DEL ESPACIADOR
COUPLING GUARD, GUARDA ACOPLE1.1251.124
DC MAX.
CREF
(4) HOLES5⁄8 DIA.
(4) AGUJEROS
5⁄8 DIA.
SINGLE PHASE ONLY, SOLO UNIFÁSICOS
ABMAX.
HE HEHA
HG
HD
X
DD
Y ZCP 3¾
PMAX.
HFHB
HL
PRIME PLUG
DRAIN PLUG
3½
Ø
Motor Bearing HA HB HD** HE HF HG HP* Frame Shim Shim
Dimension “HL” Determined by Pump and Bedplate, Dimensión “HL” determinada la bomba y el motor Motor Frame Size, Tamaño del bastidor del motor Pump, Bomba Suction*, Discharge*, CP DC Max., DD X Y Z Wt. (lbs.), 143/ 183/ 213/ 254/ 284/ Sución* Descarga* DC Máx. Peso (lib.) 145 184 215 256 286 9SH 1 X 2–6
163⁄4 5 4¾ 63⁄8 56
91⁄8 75⁄8 37⁄8 10SH 1 X 2–8 2 1 55⁄8 53⁄8 71⁄8 31⁄8 37⁄8 64
11SH 1 X 2–10 179⁄16 67⁄8 65⁄8 87⁄8 4 86 10 8½ 4¾ 4SH 1½ X 2½–6
1½ 169⁄16 5 4¾ 63⁄8 3¼ 57 9¼ 7¾ 4
7SH 1½ X 2½–8 2½
55⁄8 53⁄8 71⁄8
66 5SH 2 X 2½–6
2
175⁄16 5 4¾
4 35⁄8 57
10 8½ 4¾ 8SH 2 X 2½–8
6 5¾ 715⁄16 68
6SH 2½ X 3–6 3 2½ 59*ForusewithANSIClass150matingflanges.* Para usar con bridas que casan ANSI clase 150.
Dimensions and Weights – Determined by Pump,Dimensiones y Pesos – Determinados por la Bomba
AB P Wt. Max., CREF Max., Max., AB P Peso Máx. Máx. Máx.
Wt.(lbs.),Peso
(libras)
143T 1 1 1 1 5¼
133⁄8 65⁄8
45 1¾
145T 2 2 2 – 3 2 1½ 1½ 1½ – 2 1½ – 2 14¼ 53 10 28 8 3¾ 24 2¾ ¾ 48 —
182T 3 3 5 3 2 2 3 3 57⁄8
165⁄8 77⁄8
74 ¾
184T 5 5 7½ 5 3 or 5 3 5 3 181⁄8 95
213T 10 7½ 73⁄8
18 95⁄8
116 12 31 8¼ 4¼ 29 3 1 65 — —
215T 15 10 191⁄8 136
254T 20 15 101⁄8
215⁄8 13
266 13 42 10¼ 5¼ 38½ 4 110 — 1
256T 25 20 233⁄8 264 1¾
284TS 30 25 125⁄8
247⁄8 15
392 15 44 10½ 5¾ 40½ 3½ 124 – 1¾
286TS 40 30 265⁄8 432
PAGE 28
Commercial WaterGoulds Water Technology
Channel Steel Bedplate, Clockwise Rotation Viewed from Drive End;Fundación de Acero, Rotación en Dirección de las Agujas del Reloj Visto desde el Extremo del Motor
Three Phase, Single Phase, Three Phase, Trifásicos Monofásicos Trifásicos
MotorFrame,
Armazóndel
Motor
HA HB HD HE HF HG
HP @ 3500 RPM HP @ 1750 RPM – T-Frame Only Bedplate Data, Datos de la Fundación AB P Wt. Max., C Max., Max., AB Ref. P Peso Máx. Máx. Máx.
Available Motor and Bedplate Dimensions and Weights,Pesos y Dimensiones Disponibles de la Fundación y del Motor
Wt.(lbs.),Peso
(libras)
DD L X Y 24SH 1½ x 2½-10
2½ 1½
67⁄8 65⁄8 125
25SH 2 x 2½-10 2 23
101⁄8
815⁄16 4
125 22SH 2½ x 3-8
3
2½ 61⁄8 57⁄8 125
27SH 2½ x 3-10 67⁄8 65⁄8
915⁄16
134 23SH 3 x 4-8
4 3 24
111⁄8
5 136
28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148
CP
Dimensions and Weights – Determined by Pump,Dimensiones y Pesos – Determinados por la Bomba
NOTE:1. Pumps will be shipped with top vertical
discharge as standard. For other orienta-tions, remove casing bolts, rotate discharge to desired position and tighten 3⁄8 – 16 bolts to 20 ft./lbs., ½ – 13 bolts to 40 ft./lbs.
2. ALL dimensions in inches.
3. Not for construction purposes.
NOTA:1. Las bombas se transportarán con la des-
carga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 20 pies/libras, ½ – 13 tornillos a 40 pies/libras.
2. TODAS las dimensiones en pulgadas.
3. No para propósitos de construcción.
Wt.(lbs.),Peso
(libras)
Suction*, Discharge*, Succión* Descarga*
Pump Size,Tamaño de la Bomba
Dimensions and weights vary with manufacturers. Dimensions in inches and weights in lbs.Dimensiones y pesos varían con los fabricantes. Dimensiones en pulgadas y pesos en libras.
*ForusewithANSIclass150matingflanges.* Para usar con bridas que casan ANSI clase 150.
DCMax.,DC
Máx.
184T 3 or 5 3 5 5 57⁄8 181⁄8 77⁄8 95
213T 7½ 7½ 73⁄8
18 95⁄8
116
215T 15 10 10 191⁄8 136 13 42 101⁄4 51⁄4 38½ 4 111
254T 20 15 15 15 91⁄2
215⁄8 13
266
256T 25 20 20 20 233⁄8 264
284TS/T 30 25 25 25 125⁄8
247⁄8 15
392 15 44 10½ 5¾ 40½ 3½ 124
286TS/T 40 30 265⁄8 422
324TS/T 50 40 141⁄8
283⁄4 173⁄8
592 12
326TS/T 60 50 30¼ 634 18 48
7¼ 44½ 4 183
364TS/T 75 60 151⁄8
315⁄8 187⁄8
834 13
365TS/T 100 75 325⁄8 1000
405TS/T 100 18 367⁄8 205⁄8 1060 22 56 14 7¼ 52½ 4 214
ODP TEFC ODP TEFC ODP TEFC
Pump
ABMAX.
PRIME PLUG
HE HE
HA
DRAINPLUG
HG
HD
SUCTION
DISCHARGE
DCMAX.
3/8” GAS THREADUNI ISO 228/1
DD
CP
Y
L
HB
HF
4 HOLES
PMAX.
C REF.
1.6251.624
SPACER COUPLING
COUPLING GUARD
SINGLE PHASEONLY
KEYWAY3/16 X 3/8
415/1633/4
13/4
5/8
37/8
3⁄8" – 19 BSP
SSH-F – ENGINEERING DATA M-GROUPSSH-F – INFORMACIÓN TÉCNICA GRUPO-M
PAGE 29
Commercial WaterGoulds Water Technology
(All dimensions in inches and weights in lbs. Do not use for construction purposes.)(Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)
Motor Frame Selections,Selecciones del Armazón del Motor
DISCHARGEDESCARGA
SUCTIONSUCCIÓN
DC MAX.G
H-(4) HOLESH-(4) AGUJEROS
DD X Y Z 143/145 182/184 213/215 254/256 9SH 1 x 2 – 6 5 45⁄8 63⁄8 31⁄8
97⁄8 10½ 11½ —
36.5 10SH 1 x 2 – 8 2 1 55⁄8 5¼ 71⁄8
37⁄8 49.2
11SH 1 x 2 – 10 67⁄8 6¼ 87⁄8 4 10¾ 113⁄8 123⁄8 127⁄8 66 4SH 1½ x 2½ – 6
1½ 5 45⁄8 63⁄8 3¼ 9¾ 103⁄8 113⁄8 — 37.7
7SH 1½ x 2½ – 8 2½
55⁄8 5¼ 71⁄8
48.2 5SH 2 x 2½ – 6
2 5 45⁄8 4 35⁄8 10½
111⁄8
121⁄8 125⁄8 37.9
8SH 2 x 2½ – 8 6
5¾
77⁄8
54.6 6SH 2½ x 3 – 6 3 2½ 37⁄8 105⁄8 113⁄8 123⁄8 127⁄8 61.8
3⁄8" – 19 BSP
NOTE:1. Pumps shipped in vertical discharge as
standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 20 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.
2. ALL dimensions in inches.3. Motor dimensions may vary with motor
manufacturer.4. Not for construction purposes.
NOTA:1. Las bombas se transportarán en des-
carga vertical como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 20 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras.
2. TODAS las dimensiones en pulgadas.3. Las dimensiones puede que varíen con
los fabricantes.4. No para propósitos de construcción.
Pump,Bomba
DCMax.,DC
Máx.
Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM
Suct.*, Disch.*, Succ.* Desc.*
150 lb. Flange,Brida de 150 lib. DIM. “L” (Motor Frame Size)
DIM. “L” (Tamaño del Armazón del Motor)Wt.
(lbs.),Pesos
(libras)
*ForusewithANSIclass150matingflanges.* Para usar con bridas que casan ANSI clase 150.
ODP* TEFC* ODP* TEFC* ODP* TEFC* ODP* TEFC* 143JM – – – – – – 1 1 145JM 2 2 2-3 2 1-1½ 1-1½ 1½-2 1½-2 182JM 3 3 5 3 2 2-3 3 3 184JM 5 5 7½ 5 3 – 5 5 213JM 7½ – 10 7½ 5 – 7½ 7½ 215JM 10 – 15 10-15 – – – – 254TCZ – – 20 15** – – – – 256TCZ – – 25 20 – – – –
1Ø, Monofásicos 3Ø, Trifásicos 1Ø, Monofásicos 3Ø, Trifásicos
Motor Horsepower, Potencia del Motor 3500 RPM, 3500 RPM 1750 RPM, 1750 RPM
Motor Frame,
Armazón del Motor
AB MAX.
X
D
E EA
DD
PMAX.
F FB
L
Y Z CREF
DRAIN PLUG
PRIME PLUG
SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS S-GROUPSSH ACOPLE CERRADO – DIMENSIONES Y PESOS GRUPO-S
* Premium efficiency where required by Department of Energy regulations.* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.
** Frame size for 208-230/460 Voltage TEPE motor.** Talla de capítulo para 208-230/460 el motor del voltaje TEPE.
JM Frame,JM
ArmazónA AB
Max. B D E F G C Max.H
Dia.,H
Diám.
PMax.,
PMáx.
Motor Wt.(lbs.)
Peso Motor(lib.)
143JM6½ 5¾ 6 3½ 2¾
2 1/8 113/16
11/32 73/16
50
145JM 2½ 54
182JM85/8 67/8 6½ 4½ 3¾
2¼3/16 134/5
13/32
85/8
76
184JM2¾
101
213JM9½ 82/5 8 5¼ 4¼ 3/16 1514/25 107/25
134
215JM 3½ 169
254TCZ11½ 102/5 11½ 6¼ 5
41/87/8 201/20
17/32 1313/50
276
256TCZ 5 298
PAGE 30
Commercial WaterGoulds Water Technology
PRIME PLUG
DRAIN PLUG
D
A
SUCTION
DISCHARGE Y
CP
L
DCMAX.
3/8-19 BSP
DD
E
AB MAX.
E
G
MAX.
BF F
P MAX.
H-4 HOLES
415/16
(All dimensions in inches and weights in lbs. Do not use for construction purposes.) (Todas las dimensiones en pulgadas y pesos en libras. No usar para propósitos de construcción.)
364TCZ and 365TCZ frames are built with 326JM shaft extensions.Dimensions may vary with manufacturer.Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM. Las dimensiones puede que varíen con los fabricantes.
364TCZ and 365TCZ frames are built with 326JM shaft extensions.Los armazones 364TCZ y 365TCZ se construyen con extensiones del eje 326JM.
Motor Frame Selections,Selecciones del Armazón del Motor
Motor Horsepower, Potencia del Motor Wt.Max.,PesoMáx.
ODP* TEFC* ODP* TEFC* ODP* TEFC* 145JM – – – – 2 2 57 182JM – – 2 2, 3 3 3 77 184JM – – 3 – 5 5 97 213JM 10 – 5 – 7½ 7½ 141 215JM 15 10 – – 10 10 155 254JM 20 15 – – 15 15 265 256JM 25 20 – – 20 20 320 284JM 30 25 – – 25 25 419 286JM 40 30 – – – – 422 324JM 50 40 – – – – 562 326JM 60 50 – – – – 625 364TCZ 75 60 – – – – 775 365TCZ 100 75, 100 – – – – 905
3500 RPM 1750 RPM
Frame,Armazón 3 PH, Trifásicos 1 PH, Monofásicos 3 PH, Trifásicos
*ForusewithANSIclass150matingflanges.* Para usar con bridas que casan ANSI clase 150.
Dimensions Determined by JM Motor Frame, Dimensiones Determinadas por el Armazón del Motor JM
NOTAS:1. Las bombas se transportarán en descarga vertical como
estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 20 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras, ½ – 13 tornillos a 40 pies/libras.
2. TODAS las dimensiones en pulgadas.3. No para propósitos de construcción.
NOTES:1. Pumps shipped in vertical discharge as standard.
For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 – 16 bolts to 20 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs., ½ – 13 bolts to 40 ft./lbs.
2. Motor dimensions may vary with motor manufacturer.3. Not for construction purposes.
SSH CLOSE COUPLED – DIMENSIONS AND WEIGHTS M-GROUPSSH ACOPLE CERRADO – DIMENSIONES Y PESOS GRUPO-M
* Premium efficiency where required by Department of Energy regulations.* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.
JM Frame,JM Armazón A AB
Max. B D E F G H Dia.,H Diám.
P Max.,P Máx.
145JM 6½ 5¾ 6 3½ 2¾ 2½ 1/811/32 73/16
182JM85/8 67/8 6½ 4½ 3¾
2¼3/16
9/20
85/8 184JM
2¾213JM
9½ 81/25 8 5¼ 4¼ 3/16 105/16215JM 3½
254JM11½ 101/25 11½ 6¼ 5
41/87/8
17/32
13¼256JM 5
284JM12¾ 1613/20 1221/25 7 5½
4¾11/16 1527/64
286JM 5½
324JM14½ 1461/100 14 8 6¼
5¼1/16
69/100
1727/32326JM 6
364TCZ 17 183/50 15 9 7 55/87/8 19½
Dimensions “L” Determined by Pump and Motor, Dimensiones “L” Determinadas por la Bomba y el Motor
PumpPump Size,Tamaño de la Bomba
Suction*, Succión*
Discharge*, Descarga*
CPMax.,
CPMáx.
DCMax.,DC
Máx.DD X Y
Wt.(lbs.),Peso
(libras)
Motor Frame Size,Tamaño del Armazón del Motor
140 180 210 250 280 320 360
24SH 1½ x 2½-102½
1½ 343/867/8 6¼
815/164
92.1117/8
12½13½ 137/8 143/8
-
25SH 2 X 2½-10 2
36¾
86
1522SH 2½ X 3-83 2½
61/8 61/8 85.9 -
27SH 2½ X 3-1067/8 65/8 915/16
95.3 - -
23SH 3 X 4-84 3 37¾ 5
108.3 127/8 13½14½ 147/8 153/8 16
28SH 3 X 4 -10 75/8 73/8 111/8 113.2 - -
PAGE 31
Commercial WaterGoulds Water Technology
DC MAX.
3⁄8" – 19 BSP
½¾
KEYWAY 1⁄8 x ¼, CHAVETERO 1⁄8 x ¼
1.1251.124 DIA.
Dimensions and Weights – Bare Pump Only,Dimensiones y Pesos – Solamente Bomba
9SH 1 x 2 – 6 5 4¾
163⁄4 77⁄8 63⁄8
31⁄8 56
10SH 1 x 2 – 8 2 1 55⁄8 53⁄8 71⁄8 37⁄8 64 11SH 1 x 2 – 10 67⁄8 65⁄8 179⁄16 8¾ 87⁄8 4 86 4SH 1½ x 2½ – 6
1½ 5 4¾ 169⁄16 7¾ 63⁄8 3¼ 57
7SH 1½ x 2½ – 8 2½
55⁄8 53⁄8 71⁄8
65 5SH 2 x 2½ – 6
2 5 4¾
175⁄16 8½
4 35⁄8 57
8SH 2 x 2½ – 8 6 5¾
715⁄16
68 6SH 2½ x 3 – 6 3 2½ 59
Pump,Bomba
NOTE: 1. Pumps will be shipped
with top vertical discharge as standard. For other orientations, remove casing bolts, rotate discharge to desired position, and tighten 3⁄8 –16 bolts to 20 ft./lbs., 7⁄16 – 14 bolts to 20 ft./lbs.
2. ALL dimensions in inches.3. Not for construction
purposes.
NOTA: 1. Las bombas se
transportarán con la descarga vertical superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 20 pies/libras, 7⁄16 – 14 tornillos a 20 pies/libras.
2. TODAS las dimensiones en pulgadas.
3. No para propósitos de construcción.
Wt.(lbs.),Peso
(libras)
DD L X Y ZDC
Max.,DC
Máx. Suction*, Discharge*, Succión* Descarga*
150 lb. Flange,Brida de 150 lib. CP
Max.,CP
Máx.
7
2¾ 2¾
5¼
X
DD
PRIME PLUG
DRAIN PLUG L 5
6½
3½
ZY
CPDISCHARGEDESCARGA
SUCTIONSUCCIÓN
*ForusewithANSIclass150matingflanges.* Para usar con bridas que casan ANSI clase 150.
7⁄16 DIA. – (4) HOLES7⁄16 DIA. – (4) AGUJEROS
SSH FRAME MOUNTED – DIMENSIONS AND WEIGHTS S-GROUPSSH ARMAZÓN MONTADO – DIMENSIONES Y PESOS GRUPO-S
PAGE 32
Commercial WaterGoulds Water Technology
Dimensions and Weights – Bare Pump Only,Dimensiones y Pesos – Solamente Bomba
*ForusewithANSIclass150matingflanges.* Para usar con bridas que casan ANSI clase 150.
DD L X Y 24SH 1½ x 2½-10
2½ 1½
67⁄8 65⁄8 125
25SH 2 x 2½-10 2 23
10¼
815⁄16 4
125 22SH 2½ x 3-8
3 2½ 61⁄8 57⁄8 125
27SH 2½ x 3-10 67⁄8 65⁄8
915⁄16
134 23SH 3 x 4-8
4 3 24
11¼
5 136
28SH 3 x 4-10 75⁄8 73⁄8 111⁄8 148
CP
Wt.(lbs.),Peso
(libras)
Suction*, Discharge*, Succión* Descarga*
Pump Size,Tamaño de la Bomba
DCMax.,DC
Máx. Pump
NOTES: 1. Pumps will be shipped with top vertical discharge as
standard. For other orientations, remove casing bolts, rotate discharge to desired position, replace and tighten 3⁄8 –16 bolts to 20 ft./lbs., ½ – 13 bolts to 40 ft./lbs.
2. Motor dimensions may vary with motor manufacturer.
3. Not for construction purposes.
NOTAS: 1. Las bombas se transportarán con la descarga vertical
superior como estándar. Para otras orientaciones, retirar los tornillos de la carcasa, rotar la descarga a la posición deseada, y apretar 3⁄8 – 16 tornillos a 12 pies/libras,
½ – 13 tornillos a 40 pies/libras.
2. TODAS las dimensiones en pulgadas.
3. No para propósitos de construcción.
PRIME PLUG
DRAIN PLUG
SUCTION
DISCHARGE Y
CP
L
DCMAX.
3/8" – BSP
DD
1"
KEYWAY3/16 X 3/8
4 HOLES9/1 6 D IA .
1.6251.624
DIA.
415/16
81/2
61/2
1/2
37/8
61/4
81/2
31/231/2
SSH FRAME MOUNTED – DIMENSIONS AND WEIGHTS M-GROUPSSH ARMAZÓN MONTADO – DIMENSIONES Y PESOS GRUPO-M
PAGE 33
Commercial WaterGoulds Water Technology
SPECIFICATIONSESPECIFICACIONES
Capacities to: 1100 GPM (250 m3/hr) at 3500 RPM 775 GPM (177 m3/hr) at 1750 RPM
Heads to: 525 feet THD (158 m) at 3500 RPM130 feet THD (40 m) at 1750 RPM
Maximum working pres-sures to: 230 PSI (15 bars)
Maximum temperatures to: 250°F (121°C)
All wetted components of AISI: Type 316L stainless steel material.
Rotation: Clockwise when viewed from motor end.
Enclosed impeller and replaceable wear ring:for high efficiency and maxi-mum wear life.
Motor (close coupled):NEMA standard JM shaft open drip-proof*, totally en-closed* and explosion-proof enclosures*, 60 Hz, 1750 or 3500 RPM.Single phase ODP* (115/230 V) 1750 RPM, 1 – 5 HP.Three phase ODP*. TEFC*/Exp. proof* (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP
NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heaters for three phase ordered separately.
Motor (frame mounted): NEMA standard T-frame open drip-proof*, totally enclosed* and explosion-proof* (three phase only) enclosures 60 Hz, 1750 or 3500 RPM.Single phase (115/230 V) 1750 RPM, 1 – 5 HPThree phase (208 – 230/ 460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP
NOTE: Overload protection must be provided. Contac-tor with overload for single phase or starter with heaters for three phase ordered separately.
Optional: Rigid carbon steel bedplate, sheet metal coupling guard designed to OSHA specifications and T.B. WOODS type “SC” spacer couplings.
* Premium efficiency where required by Department of Energy regulations.
Capacidades:1100 GPM (105 m 3/hr) a 3500 RPM 775 GPM (177 m3/hr) a 1750 RPM
Cargas:525 pies THD (158 m) a 3500 RPM 130 pies THD (40 m) a 1750 RPM
Presión de trabajo máxi-ma:230 PSI (15 baras)
Temperatura máxima:250°F (121°C)
Todos los componentes mojados de AISI: Material de acero inoxidable tipo 316L.
Rotación: En dirección de las agujas del reloj visto desde el extremo final del motor.
Impulsor encerrado y anillo de desgaste reem-plazable: para alta eficien-cia y máxima durabilidad.
Motor (acople cerrado): Eje a prueba de goteo* JM estándar NEMA, totalmente encerrado* y recintos a prueba de explosión*, 60 Hz, 1750 ó 3500 RPM.Unifásicos ODP (115/230 V) 1750 RPM, 1 – 5 HP Trifásicos ODP. TEFC/a prueba de explosión (208 – 230/460 V). 3500 RPM, 2 – 100 HP 1750 RPM, 1 – 25 HP
NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contac-tor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por sepa-rado.
Motor (armazón mon-tado): Armazón abierto T a prueba de goteo* estándar NEMA, totalmente encer-rado* y recintos a prueba de explosión* (trifásicos solamente) 60 Hz, 1750 ó 3500 RPM.Unifásicos (115/230 V) 1750 RPM, 1 – 5 HP.Trifásicos (208 – 230/460 V) 3500 RPM, 3 – 125 HP 1750 RPM, 1 – 25 HP
NOTA: Se debe de propor-cionar protección térmica contra sobrecarga. Contac-tor con protección térmica contra sobrecarga para unifásicos o arrancadores con calentadores para trifásicos se piden por sepa-rado.
Opcional: Fundación rígida de acero al carbono, guarda acople de metal laminado diseñado según las espe-cificaciones OSHA y acoples del espaciador T.B. WOODS tipo “SC”.
* Eficacia superior donde se requiera por el Ministerio de regulaciones de la Energía.
PAGE 34
Commercial WaterGoulds Water Technology
Specifically designed for all traditional cast iron or bronze fitted water and low grade corrosive services.
• Water circulation
• Booster systems
• Liquid transfer
• HVAC pump replacements
• General service pumping
TYPICAL APPLICATIONSAPLICACIONES TÍPICAS
Water truck,Camión cisterna
HVAC,Calefacción, Ventilación y Aire Acondicio-nado
Diseñada específicamente para to-dos los servicios de agua de hierro fundido o recubiertas de bronce y servicios corrosivos de bajo grado.
• Circulación de Agua
• Aumento de presión
• Transferencia de líquidos
• Reemplazos para bombas HVAC
• Bombeo de servicios generales
Tubing washer,Arandela de tubería
Reverse osmosis,Ósmosis invertida
PCB washer,Arandela PCB
Textile dyes,Colorantes textiles
Boiler feed,Alimentación de caldera
PAGE 35
Commercial WaterGoulds Water Technology
NOTESNOTAS
Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license. Goulds es una marca registrada de Goulds Pumps, Inc. utilizada con permiso.© 2017 Xylem Inc. BSSH R6 September (Septiembre) 2017
Xylem Inc.2881 East Bayard Street Ext., Suite ASeneca Falls, NY 13148Phone/Teléfono: (800) 453-6777 Fax: (888) 322-5877www.gouldswatertechnology.com
1) The tissue in plants that brings water upward from the roots;2) a leading global water technology company.
We’re a global team unified in a common purpose: creating advanced technology solutions to the world’s water challenges. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. Our products and services move, treat, analyze, monitor and return water to the environment, in public utility, industrial, residential and commercial building services, and agricultural settings. With its October 2016 acquisition of Sensus, Xylem added smart metering, network technologies and advanced data analytics for water, gas and electric utilities to its portfolio of solutions. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise with a strong focus on developing comprehensive, sustainable solutions.
For more information on how Xylem can help you, go to www.xyleminc.com
1) El tejido en las plantas que hace que el agua suba desde las raíces;2) una compañía líder global en tecnología en agua.
Somos un equipo global unido por un fin común: crear soluciones de tecnología avanzada para los desafíos del mundo en relación con el agua. Desarrollando nuevas tecnologías que mejorarán la manera en que se usa, se conserva y se reutiliza el agua en el futuro es un aspecto crucial de nuestra labor. Nuestros productos y servicios desplazan, tratan, analizan, supervisan y devuelven agua al medio ambiente para clientes de servicios públicos, la industria, servicios de edificios comerciales residenciales y contextos agrícolas. Con la adquisición de Sensus en octubre de 2016, Xylem incorporó a su cartera de soluciones : mediciones inteligentes, tecnologías de red, y análisis avanzados de datos para servicios de agua, gas y electricidad. En más de 150 países, tenemos relaciones sólidas desde hace mucho tiempo con clientes que nos conocen por nuestra potente combinación de marcas de producto líderes y conocimientos de aplicación, con el un enfoque firme en el desarrollo de soluciones completas y sostenibles.
Para obtener más información, visite xyleminc.com.
Xylem
Xylem