INSTYTUT TECHNIKI BUDOWLANEJ 1 F I L T R O W A str , W A R S A W 0 0 – 6 1 1
tel.: (48 22) 825-04-71; (48 22) 825-76-55 fax: (48 22) 825-52-86
Member of the European Union of Technical approvals in Building - U E A t c
Member of the European organization responsible for Technical Approvals - E O T A
Series: TECHNICAL APPROVAL
TECHNICAL APPROVAL ITB
AT-15-7905/2009
On the ground orders of the Minister of the Infrastructure on 8 November 2004 concerning the technical approval and the organizational licensed units for their publication ( Law Gazette. No. 249, pos. 2497), as a result of the exact approbation conducted at the Institute of the Structural Engineering in Warsaw on application of the company:
WIR-PLAST Rafał Więcek
Babienica, 47A 1Maja street, LUBSZA 42-287, Poland
Stated the usability in the usage of the building of products under the name:
Roof ventilating accessories WIR-PLAST
from artificial materials
in the range and the definite principles of the Attachment, which accounts for the integral part of the Technical approval ITB
Expiration date: 22 May 2014.
D I R E C T O R Institute of Structural Engineering
Marek Kaproń
Attachment: General and technical decisions
Warsaw, 22 May 2009 . Technical Approval ITB AT-15-7905/2009 is the amendment of the Technical Approval COBR “Metalplast” AT-06-0634/2003 the II Edition. The document of the Technical Approval ITB AT-15-7905/2009 contains 45 pages. The text
of this document one can copy only as a whole. Publishing or distributing it in any other form of fragments from the text of the
Technical Approval , demands the written approval from the Institute of Structural Engineering
®
AT-15-7905/2009
GENERAL AND TECHNICAL DECISIONS
CONTENTS
2/45
ATTACHMENT
1. THE OBJECT OF THE TECHNICAL APPROVAL ................................................................... 3
2. DESTINATION, RANGE AND CONDITIONS OF USAGE ………... ...................................….. 4
3. TECHNICAL CHARACTERISTIC REQUIREMENTS............…........… ................................. 5
3.1. Materials............................................................................................................................. 5
3.2. Products........ ................................................................................................................... 5
4. PACKING, STORAGE AND TRANSPORTATION ………....................................................... 6
5.COMPATIBILITY GRADE.......................................................................................................... 7
5.1. General rules........... ........................................................................................................ 7
5.2. The reconnaissance of the type ..........................…..........................................…........... 7
5.3. The institutional production control.............................…................................................... 8
5.4. Research of ready made products.................................................................................... 8
5.5. Frequency of research........................…….….................................................................. 8
5.6. Methods of research......................................................................................................... 9
5.7. Sampling samples for research …..........…...................................................................... 9
5.8. Rating the research results.…....…...………..................................................................... 9
6. FORMALLY LEGAL SETTLEMENT………….......................................................................... 10
7. EXPIRATION DATE .............................................................................................................. 11
ADDITIONAL INFORMATION .................................................................................................... 11
DRAWINGS AND TABLES ........................................................................................................ 13
®
AT-15-7905/2009
GENERAL AND TECHNICAL DECISIONS
1. THE OBJECT OF THE TECHNICAL APPROVAL
3/45
The object of the present Technical Approval ITB are roof ventilating accessories from
artificial materials: ventilating chimnies, gravitational ventilators, surface ventilators, roof passages ,
chimney tops and chimney caps and roof basics produced by the company WIR-PLAST Rafał
Więcek, Babienica, 47A 1 Maja street, Lubsza 42-287, Poland.
These products serve to ventilate roof surfaces, ventilations of sanitary systems or
to carry through the roof elements of ventilation objects. These are single elements (table1) or
sets ( table 2), which one builds in covering roofs from rolled up materials, roofing paper
shingles, flat metal sheets, wavy, trapezoidal or roof tiles.
Shape and measurements of products presented in drawings . 1 ÷ 43.
Accessories are made from unplasticized poli ( chloride of the vinyl) (PVC-U) and
polypropylene (PP) in colours:
• grey,
• brown,
• graphite,
• red,
• brick colour,
• green,
• black.
Roof chimnies are made in the version:
• standard with a single wall,
• warmed with a double sided warmed polystyrene shaped piece.
Accessories intended are for the gravitational ventilation.
®
AT-15-7905/2009
2. DESTINATION, RANGE AND CONDITIONS OF USAGE
4/45
Ventilating chimnies, vent holes and ventilators are used to carry through
and carry out ventilation ducts above the roof, to deaerate sewage plumb drainage lines
and deaerate rooms in the attic.
Side ventilating chimnies serve to initiate the process of ventilating installations through
the wall of the building. It is used everywhere, where there is no possibility of removing the
installation vertically above the roof.
Ventilating chimnies for roofing paper are used to release the cumulation of water vapour
assembling above the water protected isolation or the thermal covered roof – the ventilation of
roofing paper, shingles.
Ventilating chimnies, vent holes and ventilators protect the ventilation ducts from the
insufflation of external air from getting damp – making it impossible to penetrate to the drain of
storm sewage.
Roof bases serve to monitor the chimnies or the ventilators:
straight on flat roofs covered with materials rolled up or with shingles,
- on slanted roofs with the inclination to 45o, covered with rolled up materials or in
shingles, sheets or wavy material trapezoidal or with roof tiles.
The type of chimnies, vent holes and ventilators and also their quantity and distribution on
the roof surface must arise out of the technical roof project taking into account the surface area
on the roof, the slope angle and the type.
The quantity , annexation diameters and the assortment of all the ventilating elements
should result from the project of the roof, decisions of norms PN-B-01707:1992,
PN-B-03430:1983, PN-B-03434:1999, PN-B-10425:1989 as well as the contracted settlements
in the decree of the Minister of the Infrastructure 12.04.2002. in the matter of technical conditions
which should correspond and their location ( Law gazette. No. 75/2002, pos. 690,
Section IV § 125, § 140 i § 147).
Chimnies, vent holes and surface ventilators should be built in into the surface of the
roof in kind and the quantities in accordance with the project and the technical documents
of the building in the allocated places. The colour of the chimnies, vent holes
®
AT-15-7905/2009
5/45
and surface ventilators should be chosen in accordance to the colour of the roof covering and
colour of the object.
The chimnies must have a well chosen and well fitted diameter which will not cause a
reduction in the diameter of the ventilation duct.
3. TECHNICAL CHARACTERISTIC REQUIREMENTS
3.1. Materials
For the production of roof accessories the following materials should be used:
• polypropylene PP for the formation of gushing in compliance with PN-EN ISO 1873-1:2000,
• unplasticized polyvinyl chloride PVC-U for the formation of gushing and imprint in
accordance with PN-EN ISO 1163-1:2000,
• UV stabilizer,
• dyes for artificial materials,
• Butle rubber seals black for usage in the temperature range from -40 0 C
to +90 0 C,
• aluminium sheets with the thickness of 1 mm type EN AW 1050A wg PN-EN 573-3:2009,
• rubber with the hardness 59 ShA or EPDM hardness 55 ShA,
• pipes from PVC-U according to PN-EN 1329-1:2001,
• pipes from PP according to PN-EN 1451-1:2001,
• polystyrene EPS 70-040 according to PN-EN 13163:2009,
3.2. Products
3.2.1. The surface. Chimnies, vent holes and surface ventilators as well as other
accessories should have a smooth surface without blisters, cracks,
burns and openings.
It is acceptable for the occurrence of mechanical outlines, little fish eyes and traces of
mechanical tooling. The accessories should have an equal colour all over.
®
AT-15-7905/2009
6/45
3.2.2. Shape and measurement. The shape and measurement of the products should be in
accordance with drawings 1 to 43.
3.2.3. Softening temperature according to Vicata. Softening temperature according to
Vicata at the pressure of 50 N not less than 75 0C.
3.2.4. Thermal stability. Chimnies, vent holes and surface ventilators
and the basis for processed temperatures of 1500C for 15 or 30 min should not show blisters,
signs of splits on the material, damages of welding and surface shapes in places of the injection,
penetrating deeper than 50% of the thickness of the side walls. Shaped pieces up to 3 mm in
thickness should be warmed up for 15 min, and the shaped pieces of thickness of more than 3
mm for 30 min.
3.2.5. Impact resistance. The definite impact of resistance with the Charpy method on
samples with the double notch should not be less than 5 kJ/m2.
4. PACKING, STORAGE AND TRANSPORTATION
Chimnies, vent holes and surface ventilators and the basis enfolded in the Technical
Approval should be provided in their original wrappings of the manufacturer and
Stored as well as transported in accordance with the instructions of the manufacturer in such a
way that it ensures no changes in their technical characteristics.
On the package there should be information allocated implicating at least the following
information:
name and adress of the Manufacturer,
identification of the product containing the name and destination of the product,
number of Technical Approval ITB AT-15-7905/2009,
number and date displayed on the national decleration agreement,
building sign.
The way of marking the article with the builder's sign should be in accordance
with the order of the Minister of the Infrastructure 11 August 2004, in the matter of ways declaring
accordance of the building products as well as ways of marking their building sign ( Law gazette.
No. 198/2004, pos. 2041).
®
5.1. General rules
AT-15-7905/2009
5. COMPATIBILITY GRADE
7/45
In accordance with art. 4, art. 5 paragraph. 1 point. 3 and art. 8 paragraph 1 according to
the law 16 April 2004.
about the building products (Law gazette. No 92/2004, pos. 881) products which refer to the
present Technical Approval which can be introduced to the turn over and used in the realization
of the building work in the range of appropriate properties and destinations, if the manufacturer
did the compatibility grade, gave a national declaration agreement of the Technical Approval
ITB AT-15-7905/2009 and marked the products with the builder’s sign in accordance with the
present regulations.
In compliance with the decree of the Minister of Infrastructure on 11 August 2004.
Concerning the ways of declaring the concordance of building products and the manner of
marking them with the builder’s sign (Law gazette. No. 198/2004, pos. 2041), compatibility
grade of products Technical Approval iTB AT-15-7905/2009 the Producer makes in accordance
with system 4.
In the case of system 4 of the compatibility grade , the producer can give a national
declaration agreement of the Technical Approval ITB AT-15-7905/2009 on the basis:
1 the reconnaissance of the passed research by the Producer or if ordered by them,
2 the institutional production control .
5.2. The reconnaissance of the type
The reconnaissance of the type is research which confirms the required properties
technically useful, produced before the introduction of the product to the turnover.
The reconnaissance of the type includes:
• softening temperature according to Vicata,
• thermal stability,
• impact resistance according to Charpy.
Research which in the approbation procedure were the bases in determining the
technically useful features of the product, determine the reconnaissance of the type in compatibility
grade.
®
AT-15-7905/2009
8/45
5.3. The institutional production control
The institutional production control includes:
1. the specification and checking of raw materials and components,
2. the inspection and research in the process of production and researching ready made
products (p. 5.4), lead by the producer in compliance with the agreed research plan and
according to the rules and definite procedures in the documents of the institutional
production control, adapted to the technology production and in pursuit of obtaining products
with the required proprieties.
The production control should assure that the product is in accordance with the Technical
Approval ITB AT-15-7905/2009. The results of the production control should be systematically
registered.
Recordings of the register should confirm that the product fulfills the criteria of the
compatibility grade
Every batch of products should be univocally identified in the research register and
commercial documents.
5.4. Research of ready made products
5.4.1. Research programme. Research programme includes:
• current research,
• periodic research.
5.4.2. Current research. Current research include inspecting:
• surface appearance,
• shape and measurements.
5.4.3. Periodic research. Periodic research include inspecting:
• softening temperature according to Vicata,
• thermal stability,
• impact resistance according to Charpy.
5.5. Frequency of research
Current research should be done in compliance with the agreed research plan, but not less
freqently than for every batch of products. The size of the batch of products should be specified
in the documents of the institutional production control.
Routine tests should be done not less frequently than once every 3 years.
®
5.6. Method of research
AT-15-7905/2009
9/45
5.6.1. Inspecting the surface appearance. Inspecting the surface appearance of the products
should be done in compliance with PN-EN 13018:2004 through visual inspection
unarmed in the natural light (daily) or diffused artificial light from a distance (0,3 ÷ 0,5) m, at an
angle of the evaluated colour and the occurrence of damages.
5.6.2. Inspecting the shape and measurements. The inspection of the shapes consists of
inspecting the products in accordance with the requirements of the norm PN-EN 13018:2004
and comparing them with the drawings in the approval.
Inspecting the measurements should be done in compliance with PN-EN ISO 3126:2006.
5.6.3. Inspecting the softening temperature according to Vicata. Determining the softening
temperature according to Vicata (VST) should be done in compliance with the agreed norms
PN-EN 727:1998.
5.6.4. Inspecting the thermal stability. The research should be carried out in accordance
with the agreed norms PN-EN ISO 580:2006 method A.
5.6.5. Inspecting the impact resistance Charpy method. The research should be carried out
in accordance with the agreed norms PN-EN ISO 179-1:2004.
5.7. Sampling the samples for research
Sampling the samples for research should be done in accordance with norm PN-N-
03010:1983.
5.8. Rating the research results
The produced product should be accordant with the requirements of the current Technical
approval ITB, if all of the research results are positive.
®
AT-15-7905/2009
6. FORMALLY LEGAL SETTLEMENT
10/45
6.1. Technical Approval ITB AT-15-7905/2009 replaces the Technical Approval
COBR PEWB ”Metalplast” AT-06-0634/2003 II Edition.
6.2. Technical Approval ITB AT-15-7905/2009 is a document declaring the usefulness of
roof ventilating accessories of WIR-PLAST to use in building in the consequential range from
decisions of the Approval.
According to article. 4, art. 5 paragraph. 1 pt. 3 and art. 8 par. 1 Act on 16 April 2004.
about building products (Law gazette. No 92/2004, pos. 881), products which apply to the
current Technical Approval can be introduced to the turn over and used at building operations in
the range of appropriately used features and destination, if the producer did the compatibility
grade and gave a national declaration in accordance to the Technical Approval ITB AT-15-
7905/2009 and marked the products with the building sign in accordance with the current
regulations.
6.3. Technical Approval ITB does not violate the regulations that are consequent about the
protection of industrial property, particularly the announcement of the President of the Parlament
in the Republic of Poland on 13 June 2003 in the matter of announcing an equal text law on 30
June 2000. The law of industrial property (Law gazette. No 119, pos. 1117
+ changes – Law gazette. No. 33/2004, pos. 286). The assurance of these authorizations
belong to the duty of using the current Technical Approval ITB.
6.4. ITB publishing the Technical Approval do not take the responsibility of possible
violation of the law sole and acquired.
6.5. Technical Approval ITB does not dismiss the Producer of products the responsibility of
the correct quality, and the executive authority of the building works from the responsibility of
their proper usage.
6.6. In the content of handed out leaflets and advertisements or other documents
connected with the introduction of the trade and the usage in the building of roof ventilating
accessories WIR- PLAST one ought to give information of products about the Technical Approval
ITB AT-15-7905/2009.
®
AT-15-7905/2009
7. EXPIRATION DATE
11/45
Technical Approval ITB AT-15-7905/2009 is valid until 22 May 2014.
The validity of the Technical Approval ITB can be extended for the following terms if its petitioner
or legal successor goes in this case to the Institute of the Structural Engineering with the correct
application not later than 3 months before the expiration date of this document.
The End
ADDITIONAL INFORMATION
Norms and documents attached
PN-EN 573-3:2009
PN-EN 727:1998
PN-EN 1329-1:2001
PN-EN 1451-1:2001
PN-EN 13018:2004
PN-EN 13163:2009
Aluminium and aluminium feet. Chemical composition and kinds of products
processed plastically. Part 3: Chemical composition and kinds of
products
Line systems from plastics. Tubing and shaped pieces
from thermoplastic materials. Denotation of the softening temperature
according to Vicata (VST)
Line systems from plastics to lead
dirt and sewage ( with low and high temperature)
inside the construction of the building. Unplasticized poly (the chloride of the
vinyl) (PVC-U). Part 1: Requirements concerning tubing , shaped pieces and
the system
Line systems from plastics to lead dirt and sewage ( with low and high
temperatures) inside the construction of the building. Polypropylene (PP). Part
1: Requirements concerning pipes, shaped pieces and the system.
Non destructive research. Visual research. General rules
Products for the heat insulation in building. Products from polystyrene
(EPS) factory produced. Specification
PN-EN ISO 179-1:2004 Marking the impact of resistance with the Charpy method .
Part 1: Uninstrumental researching of the impact resistance
®
AT-15-7905/2009
12/45
PN-EN ISO 580:2006
System of pipe lines and the covering of tubes from artificial materials.
The shaped pieces injections from thermoplastic materials.
Methods of visual grade in changes as a result of heating
PN-EN ISO 1163-1:2000 Artificial materials. Unplasticized poly(the chloride of the vinyl)
(PVC-U) for the formation of gush and imprints. System of marking is the
basis for classification.
PN-EN ISO 1873-1:2000 Artificial materials. Polypropylene (PP) for the formation of
gush and imprints. System of marking is the basis for classification.
PN-EN ISO 3126:2006 System of pipe lines from artificial materials. Elements from artificial materials.
Inspecting the measurements.
PN-B-01707:1992
PN-B-03430:1983
PN-B-03434:1999
PN-B-10425:1989
PN-N-03010:1983
Sewerage systems. Requirements in designing
The ventilation in the living quarters, the collective residence
and the public utility. Requirements
Ventilation. Ventilation pipes. Basic requirements
and research
Chimney pipes, internal-combustion and ventilating cinch from brick.
Technical requirements and research on collection.
Statistical quality control. Random choice of product units of
the sample
Research reports, statements and ratings
• Research report no LOW/509.1/2009 ventilation chimnies and ventilators
WIR-PLAST from artificial materials. Okuć Laboratory and Ślusarki Building ITB
Department Wielkopolski, Poznań.
• Research statement no 112/2003 done in the Accredited Research Laboratory
COBR PEWB ”Metalplast”, Poznań.
®
AT-15-7905/2009
DRAWINGS AND TABLES
Drawings
13/45
Pg.
Draw. 1. Ventilation chimnies [K1, K2, K3, K4] .......................................................... 15
Draw. 2. Ventilation chimnies from PVC-U [K5, K6] ..................................….............. 16
Draw. 3. Chimney for roofing paper [K40, K41] ........................................….............. 17
Draw. 4. Ventilators gravitational annular [K9, K10, K11, K12, K13] ........……........... 18
Draw. 5. Ventilators gravitational type H from PVC-U [K15] ....................…............... 19
Draw. 6. Side ventilation chimney from PVC-U [K16] ............................….…............ 19
Draw. 7. Surface ventilators type A [P2] .……........................................……............. 20
Draw. 8. Surface ventilators type B to cover bituminous [K18] ..…….....…….............. 20
Draw. 9. Connecting pipe from VC-U [K33] .........………...............................…..…..... 21
Draw. 10. Reduction [K35, K36] .................................................................................. 21
Draw. 11. Reduction for the straight base [37] ............................................................ 22
Draw. 12. Reduction for surface ventilators type A [K34] …….................................... 22
Draw. 13. Ventilation chimney regulated with a roof passage and a neck band sealing it to the roofing sheet [K38] ................................................................ 22
Draw. 14. Roof bases straight, round [K31, K32] ……………………........................... 23
Draw. 15. Roof bases from PVC-U [K27, K29] ………………..................................... 23
Draw. 16. Roof bases from PVC-U for chimney heads [K29] .……….......................... 24
Draw. 17. Roof bases from PVC-U with a butyl seal [K28, K30] ……......................... 24
Draw. 18. Chimney head [K14] .......………………....................................................... 25
Draw. 19. Chimney head for the ventilator [K45] ......................................................... 25
Draw. 20. Chimney ventilator regulated Ø 110/490 with a roof passage STANDARD [K21] .......................................................................................... 26
Draw. 21. Chimney ventilator regulated Ø 110/490 with a roof passage UNIWERSAL [K25] ......................................................................................... 26
Draw. 22. Chimney ventilator regulated Ø 110/490 with a straight roof passage NORMAL 110 [K23] ........................................................................................ 27
Draw. 23. Chimney ventilator regulated, insulated Ø 110/490 with a roof passage STANDARD [K22] ......................................................................................... 27
Draw. 24. Chimney ventilator regulated, insulated Ø 110/490 with a roof passage UNIWERSAL [K26] ........................................................................................ 28
Draw. 25. Chimney ventilator regulated , insulated Ø 110/490 with a roof passage NORMAL 110 [K24] .................................……………….................................. 28
®
AT-15-7905/2009
14/45
Draw. 26. Chimney ventilator regulated to the ventilator with a roof passage STANDARD [K42] .................................…………............................................…...... 29
Draw. 27. Chimney ventilator regulated to the ventilator with a roof passage UNIWERSAL [K44] ....................................……………………............................….... 29
Draw. 28. Chimney ventilator regulated to the ventilator with a roof passage NORMAL 110 [K43] ..........................................................….…………………………. 30
Draw. 29. Surface ventilator type A with a roof passage SIMPLE [K17] ….…..………..…….. 30
Draw. 30. Surface ventilator with a roof passage OPTIMUM [K20] ……............……...……. 31
Draw. 31. Surface ventilator with a wavy roof passage EASY [K19] .…………….….………... 31
Draw. 32. Surface ventilator with a wavy roof passage ROLLING [K51] …………….…….. ... 31
Draw. 33. Chimney ventilator regulated Ø 110/490 with a wavy roof passage PERFEKTA 110 [K48] ....................................................…………………….……...... 32
Draw. 34 Chimney ventilator regulated, insulated Ø 110/490 with a wavy roof passage PERFEKTA 110 [K49] .........................………………………..............................….... 32
Draw. 35. Chimney ventilator regulated Ø 110/490 to the ventilator with a wavy roof passage PERFEKTA 110 [K50] .....................…………………………………....... 33
Draw 36. Chimney ventilator regulated Ø 150/700 with a straight roof passage NORMAL 150 [K52] ..............................................………………………….................. 33
Draw. 37. Chimney ventilator regulated Ø 150/700 with a wavy roof passage PERFEKTA 150 [K53] ...................................................…………………................... 34
Draw. 38 Chimney ventilator regulated, insulated Ø 150/700 with a straight roof passage NORMAL 150 [K54] ...................................………………………….............. 34
Draw. 39 Chimney ventilator regulated, insulated Ø 150/700 with a wavy roof passage PERFEKTA 150 [K55] .............................…………………………................ 35
Draw. 40. Chimney ventilator regulated Ø 110 with the roof passage TILE to cover roof tiles [K56] ……....................................………………………................... 35
Draw. 41 Chimney ventilator regulated, insulated Ø 110 with the roof passage TILE to cover roof tiles [K57].................................……………..………………..................... 36
Draw. 42. Chimney ventilator regulated Ø 150 with the roof passage TILE to cover roof tiles [K58] ..................…………………………….…………………........... 36
Draw. 43. Chimney ventilator regulated, insulated Ø 150 with the roof passage TILE to cover roof tiles [K59] ..............……………………………….…………………............ 37
Tables
Table 1. Single products ......................................................................................................... 38
Table 2. Ready made units for installations ............................................................................ 42
®
K1
K3
AT-15-7905/2009
K2
K4
15/45
Draw. 1. Ventilation chimnies
®
AT-15-7905/2009
Draw. 2. Ventilation chimnies from PVC-U
K5
K6
16/45
®
AT-15-7905/2009
Draw. 3. Chimney for roofing paper
17/45
K40 75 x 270
K41 110 x 325
®
K9
K11
AT-15-7905/2009
K10
K12
K13
18/45
Draw. 4. Ventilators gravitational annular
®
AT-15-7905/2009
Draw. 5. Ventilators gravitational type H from PVC-U
Draw. 6. Side ventilation chimney from PVC-U
K15
K16
19/45
®
AT-15-7905/2009
Draw. 7. Surface ventilators type A
P2
K18
20/45
Draw. 8. Surface ventilators type B to cover bituminous [K18]
®
AT-15-7905/2009
K33
21/45
Draw. 9. Connecting pipe from VC-U
Draw. 10. Reduction
K36
K35
®
AT-15-7905/2009
Draw. 11. Reduction for the straight base
K37
K34
22/45
Draw. 12. Reduction for surface ventilators type A
K38
Draw. 13. Ventilation chimney regulated with a roof passage and a neck band sealing it to the roofing sheet
®
AT-15-7905/2009
Draw. 14. Roof bases straight, round
Draw. 15. Roof bases from PVC-U
K32
K31
K27
K29
23/45
®
AT-15-7905/2009
Draw. 16. Roof bases from PVC-U for chimney heads
K28
K30
Draw. 17. Roof bases from PVC-U with a butyl seal
K29
24/45
®
AT-15-7905/2009
K14
Draw. 18. Chimney head
K45
Draw. 19. Chimney head for the ventilator
25/45
®
AT-15-7905/2009
K21
26/45
Draw. 20. Chimney ventilator regulated Ø 110/490 with a roof passage STANDARD
K25
Draw. 21. Chimney ventilator regulated Ø 110/490 with a roof passage UNIWERSAL
®
AT-15-7905/2009
K23
Draw. 22. Chimney ventilator regulated Ø 110/490 with
a straight roof passage NORMAL 110
Draw. 23. Chimney ventilator regulated, insulated Ø
110/490 with a roof passage STANDARD
K22
27/45
®
AT-15-7905/2009
Draw. 24. Chimney ventilator regulated, insulated Ø
110/490 with a roof passage UNIWERSAL
Draw. 25. Chimney ventilator regulated , insulated Ø
110/490 with a roof passage NORMAL 110
K26
K24
28/45
®
AT-15-7905/2009
Draw. 26. Chimney ventilator regulated to the ventilator with a roof passage STANDARD
Draw. 27. Chimney ventilator regulated to the
ventilator with a roof passage UNIWERSAL
K42
K44
29/45
®
AT-15-7905/2009
Draw. 28. Chimney ventilator regulated to the
ventilator with a roof passage NORMAL 110
K43
K17
30/45
Draw. 29. Surface ventilator type A with a roof passage SIMPLE
®
AT-15-7905/2009
31/45
K20
Draw. 30. Surface ventilator with a roof passage OPTIMUM
K19
Draw. 31. Surface ventilator with a wavy roof passage EASY
K51
Draw. 32. Surface ventilator with a wavy roof passage ROLLING
®
AT-15-7905/2009
Draw. 33. Chimney ventilator regulated Ø 110/490
with a wavy roof passage PERFEKTA 110
Draw. 34. Chimney ventilator regulated, insulated Ø
110/490 with a wavy roof passage PERFEKTA 110
[K49]
K48
K49
32/45
®
AT-15-7905/2009
K50
33/45
Draw. 35. Chimney ventilator regulated Ø110/490 to the ventilator with a
wavy roof passage PERFEKTA 110
K52
Draw. 36. Chimney ventilator regulated Ø 150/700 with a straight roof passage NORMAL 150
®
AT-15-7905/2009
K53
34/45
Draw. 37. Chimney ventilator regulated Ø 150/700
with a wavy roof passage PERFEKTA 150
Draw. 38. Chimney ventilator regulated, insulated Ø
150/700 with a straight roof passage NORMAL 150
K54
®
AT-15-7905/2009
K55
35/45
Draw. 39. Chimney ventilator regulated, insulated Ø
150/700 with a wavy roof passage PERFEKTA 150
Draw. 40. Chimney ventilator regulated Ø 110 with the
roof passage TILE to cover roof tiles
K56
®
AT-15-7905/2009
Draw. 41. Chimney ventilator regulated, insulated
Ø 110 with the roof passage TILE to cover roof tiles
Draw. 42. Chimney ventilator regulated Ø 150 with
the roof passage TILE to cover roof tiles
K58
36/45
K57
®
AT-15-7905/2009
K59
37/45
Draw. 43. Chimney ventilator regulated, insulated Ø 150 with the roof passage TILE to cover roof tiles
®
AT-15-7905/2009
Single products
Diameter
38/45
Table 1
Pos. Brand name of product Drawing Material x height or width
[mm]
No according to catalogue
1 1
2
3
4
5
6
7
8
9
10 11
12
13
14
2 Ventilation chimnies [draw. 1]
Ventilation chimnies PVC
[draw. 2]
Ventilation chimnies for
roof paper [draw. 3]
Ventilators gravitational annualar [draw. 4]
-for a chimney with a neck band
sealing K38
3 4 PP
PP
PVC-U
PP
PP
5 50 x 255 75 x 250 110 x 305
110 x 147
110 x 330
160x500 (335)
75 x 270 Ø 300
110 x 325
Ø 300
50 x 190
75x 200 110x310 160 x 430 200 x 340 110x635
6 K1 K2 K3
K4
K5
K6
K40
K41
K9
K10 K11 K12 K13 P1
15 Ventilators gravitational
type H [draw.5]
16 Side ventilation chimney
[draw. 6]
17 Surface ventilators type A
for K17, 19 i 20 [draw. 7, 29, 30, 31]
18 Connecting pipe
[draw. 9]
PVC-U
PVC-U
PP
PVC-U
110X680
110X330
217x285/ 110
110 x 380
K15
K16
P2
K33
19
20
Reduction [draw. 10]
PP
Ø 150/ Ø 160
Ø 100/ Ø 110
K35
K36
®
AT-15-7905/2009
Diameter
39/45
c.d. table 1
Pos. Brand name of product Drawing Material x height of width
[mm]
No according to catalogue
1 2 3 4 5 6
21 Reduction for the straight base
[draw. 11]
22 Reduction for surface
ventilators type A under the shingle covering and rolled materials [draw. 12]
23 Sealed neck band for K38 [draw. 13]
24 Roof bases straight (round) [draw. 14]
PP
PP
Aluminium
EPDM Pipe PVC-U
PP
Ø 110
Ø 150/ Ø 110
250x280
Ø 75
Ø 110
K37
K34
K39
K31
K32
25
26
27
28
Roof bases
[draw. 15, 16]
Roof bases
with a butyl seal. [draw. 17]
PVC- U
PVC- U Butyl rubber
Ø 160
Measurement
according to order
Ø 200
Measurement
according to order
Ø 160 Measurement
according to order
Ø 200 Measurement
according to order
K27
K29-1
K28
K30
29 Chimney head
[draw. 18]
30 Chimney head
for the ventilator [draw. 19]
31 Chimney ventilator
regulated Ø 110/490 for K21, 25 and 23 [draw. 20, 21, 22]
32 Chimney ventilator regulated isolated
Ø 110/490 for K22, 26 and 24 [draw. 23, 24, 25]
PP
PP
WTL-125
PP
PP
Ø 150 H -440
Ø 150
H-398
Ø 110
H-490
Ø 110 H-490
K14
K45
P3
P4
®
AT-15-7905/2009
Diameter
40/45
c.d. table 1
Pos. Brand name of product Drawing Material x height of width
[mm]
No according to catalogue
1 2 3 4 5 6 33 Chimney ventilator
regulated Ø150/700 for K52 and 53 [draw. 36, 37]
34 Chimney ventilator regulated isulated
Ø 150/700 for K 54 and 55 [draw. 38, 39]
35 Chimney ventilator
regulated to the ventilator
Ø 110/490 to K42, 43 and 44 [draw. 26, 27, 28]
36 Bitumious roof passage
”STANDARD” for K21, 22 and 42 [draw. 20, 23, 26]
37 Bitumious roof passage
”SIMPLE” for K 17 [draw. 29]
38 Universal roof passage for wavy roof sheets ”UNIWERSAL” for K 25, 26 i 44
[draw. 21, 24, 27]
39 Roof passage for wavy
covering ”OPTIMUM” for K20 [draw. 29]
40 Roof passage for flat covering ”EASY” for K19
[draw. 31]
41 Roof passage for wavy covering ”ROLLING” for K51 [draw. 32]
42 Roof passage straight for
flat covering ”NORMAL 110” for K 23, 24 and 43 [draw. 22, 25, 28]
PP
PP
PP
WTL-125
PP
PP
PP
PP
PP Butyl rubber seal
protected with silicone
paper
PP Butyl rubber seal
protected with silicone
paper
PP Butyl rubber seal
protected with silicone
paper
Ø 150 H 700
Ø 150 H 700
Ø110
H-490
468x390
468X390
445x295
445x295
oval 310x234
oval 310x234
oval 310x234
P5
P6
P7
P8
P9
P10
P11
P12
P13
P14
®
AT-15-7905/2009
Diameter x
41/45
c.d. tablicy 1
Pozs Brand name of product Drawing Material height or width
[mm]
No according to
catalogue1 2 3 4 5 6 43 Roof passages for moulded
roof covering ”PERFEKTA” 110” for K 48, 49 and 50 [draw. 33, 34, 35]
44 Straight roof passage for flat covering ”NORMAL” 150” for K 52 and 54
[draw. 36, 38]
45 Roof passages for moulded roof covering ”PERFEKTA” 150” for K 53 and 55 [draw. 37, 39]
46 Roof passage for roof tile covering ”TILE”
Single products:
PP Butyl rubber seal
protected with silicone
paper
PP Butyl rubber seal
protected with silicone
paper
PP Butyl rubber seal protected with silicone
paper
PP
Oval 310x234
Oval 365x225
Oval 365x225
420x335
P15
P16
P17
P18
Ventilation chimnies and ventilators, roofing paper chimnies, connecting pipes, reduction, roof bases, chimney heads, sealed neck band, which are produced as ready made elements and are introducted to the
turn over as single (are marked as K) or are ready made factory elements of assemblage sets (marked as P).
®
AT-15-7905/2009
Ready made assemblage sets
Material/
Diameter
x
42/45
Table 2
No Pos.
1
Brand name of product
2
Drawing
3
Elements to complete
sets
4
height or
width [mm]
5
Elements for sets
6
according to
catalogue
7
1 Surface ventilator type A with a roof passage ”SIMPLE”
for bitumious covering. [draw. 29]
2 Surface ventilator type B for bitumious covering. [draw. 8]
PP Screws 4,5x30 - 4 pieces.
PP Screws 4,5x30 - 4 pieces.
468x390
490x340
P2 + P9
To use with K33 and K34
Set.
K17
K18
3 Surface ventilator with roof passage
Screws
PP 468x390 P2 +P11 + K39 K20
”OPTIMUM” for wavy roof sheets [draw. 30]
4 Surface ventilator with straight roof passage ”EASY” for existing bitumious covering, flat and trapezoidal roof sheets. [draw. 31]
5 Surface ventilator
with roof passage ”ROLLING” for moulded roof covering. [draw. 32]
6 Ventilation chimney
regulated Ø 110/490 with roof passage ”STANDARD” for bitumious covering. [draw. 20]
7 Ventilation chimney
regulated thermal
Ø 110/490 with roof passage ”STANDARD” bitumious covering.
[draw. 23]
8 Ventilation chimney
regulated to the
ventilator with roof passage
“STANDARD” for bitumious covering.
[draw. 26]
Farmer’s: 4,5x30 - 23 pieces., 4,5x60 - 1 pieces. Assemblage mould Tiler’s silicone - 40ml
PP Screws
4,5x60 - 10 pieces
PP Screws
4,5x60 - 10 pieces.
PP
Screws 4,5x30 - 4 pieces.
PP
Screws 4,5x30 - 4 pieces
PP
Screws
4,5x30 - 4 pieces.
and 4,5x60 - 10
pieces.
oval 310x237
oval
310x237
Ø 110
Ø 110
Ø110
P2+P12
P2+P13
P3+ P8
To use with K33 and K36
P4+ P8
To use with K33 and K36
P7+ P8
To use with K33 and K36
K19
K51
K21
K22
K42
®
AT-15-7905/2009
Material/
Diameter
x
43/45
c.d. table 2
No
Pos.
1
Brand name of product
2
Drawing
3
Elements to complete
sets
4
height or
width [mm]
5
Elements for sets
6
according to
catalogue
7
9 Ventilation chimney
regulated Ø 110/490 with roof passage ”UNIWERSAL” for wavy roof sheets [draw. 21]
10 Ventilation chimney
regulated Ø 110/490 isulated with roof passage ”UNIWERSAL” for wavy roof sheets [draw. 24]
11 Ventilation chimney
regulated Ø 110/490 to the ventilator with roof passage ”UNIWERSAL” for wavy roof sheets [draw. 27]
PP Screws
Farmer’s
4,5x30 - 27 pieces.
and 4,5x60 - 1 pieces.
Tiler’s silicone
- 40 ml
PP Screws 4,5x30 - 27 pieces. andi 4,5x60 - 1 piece Tiler’s silicone - 40 ml
PP Screws
4,5x30 - 27
pieces.
and 4,5x60 - 1 piece
Tiler’s silicone
- 40 ml
Ø 110 P3+ P10 +K39 + K33 and K36
Ø 110 P4+ P10 +K39
+ K33 and K36
Ø 110 P7+ P10 +K39
+ K33 and K36
K25
K26
K44
12 Ventilation chimney
regulated Ø 110/490
Screws
PP
Ø 110
P3+ P14
To use with
K23
with straight roof passage ”NORMAL” for existing bitumious covering, flat roof sheets and trapezoidal. [draw. 22]
13 Ventilation chimney
regulated insulated
Ø 110/490 with straight roof passage ”NORMAL” for existing
bitumious covering, flat roof sheets and
trapezoidal.
[draw. 25]
14 Ventilation chimney
regulated Ø 110/490 for the ventilator with a straight roof passage ”NORMAL” for existing bitumious covering, flat roof sheets and trapezoidal. [draw. 28]
4,5x30 - 4 pieces and 4,5x60 - 10 pieces.
PP Screws 4,5x30 - 4 pieces and 4,5x60 - 10 pieces.
PP
Screws
4,5x30 - 4 pieces.
and 4,5x60 - 10
pieces.
Ø 110
Ø110
K33 and K36
P4+ P14
To use with K33 and K36
P7+ P14
To use with K33 and K36
K24
K43
®
AT-15-7905/2009
Material/
Diameter x
44/45
c.d. table 2
Pos.
1
Name
2
Picture
3
Elements to complete
sets
4
height or
width [mm]
5
Elements for sets
6
No
according to
catalogue
7
15 Ventilation chimney
regulated Ø 110/490 with wavy roof passage ”PERFEKTA” for moulded covering. [draw. 33]
16 Ventilation chimney regulated insulated
Ø 110/490 with wavy roof passage ”PERFEKTA 110” for moulded covering. [draw. 34]
17 Ventilation chimney
regulated Ø 110/490 for the ventilator with wavy roof passage ”PERFEKTA 110” for moulded covering [draw. 35]
18 Ventilation chimney
regulated Ø 150/700 with a straight roof passage ”NORMAL 150” for existing bitumious covering, flat roof sheets
and trapezoidal [draw. 36]
19 Ventilation chimney
regulated Ø 150/700 with a wavy roof passage ”PERFEKTA
150” for moulded covering. [draw. 37]
20 Ventilation chimney
regulated insulated
Ø 150/700 with straight roof passage ”NORMAL 150” for existing bitumious covering, flat roof sheets and trapezoidal.
[draw. 38]
PP Screws
4,5x30 - 4 pieces
and 4,5x60 - 10
pieces.
PP Screws
4,5x30 - 4 pieces
and 4,5x60 - 10
pieces.
PP Screws
4,5x30 - 4 pieces
and 4,5x60 - 10
pieces.
PP
Screws
4,5x30 - 4 pieces
and 4,5x60 - 10
pieces.
PP Screws
4,5x30 - 4 pieces and 4,5x60 - 10 pieces.
PP Screws
4,5x30 - 4 pieces and 4,5x60 - 10 pieces.
Ø 110
Ø 110
Ø 110
Ø 150
Ø 150
Ø 150
P3+ P15 To use with
K33 and K36
P4+ P15
To use with K33 and K36
P7+ P15
To use with K33 and K36
P5 + P16
P5 + P17
P6 + P16
K48
K49
K50
K52
K53
K54
®
AT-15-7905/2009
Material/
Diameter
x
45/45
c.d. table 2
No
Pos.
1
Name
2
Picture
3
Elements to complete
sets
4
height or
width [mm]
5
Elements for sets
6
according to
catalogue
7
21 Ventilation chimney regulated insulated
Ø 150/700 with wavy roof passage „PERFEKTA 150” for moulded covering. [draw. 39]
22 Ventilation chimney
regulated Ø 110 with passage ”TILE” for covering roof tiles.
23 Ventilation chimney
regulated insulated
Ø 110 with passage ”TILE” for covering roof tiles.
PP Screws
4,5x30 - 4 pieces.
and 4,5x60 - 10
pieces.
PP
PP
Ø 150
Ø 110
Ø 110
P6 + P17
P3+P18
P4+P18
K55
K56
K57
24 Ventilation chimney
regulated with roof passage and sealed neck band for roof sheets [draw. 13]
PP
Assemblage
mould
Screws 4,5x30
- 16 pieces.
Assemblage
mould
Tiler’s silicone
- 40 ml.
Ø 110x635 P1+ K39
K38
25 Neck bands with base. [Bases and soles according to draw. 16 and 18. Drawings of cases according
to orders]
Factory set:
PP + PVC-U According to individual order
Cases according to project +
K14
K47
Ready made factory sets: ventilators, or regulated chimnies – are for ventilation sets for slanted roofs
covered with rolled materials, shingles or roof sheets. Complete sets are from chosen functional single products (P or K) and consist of roof base and chimney or the ventilator from
moulded bases and connecting elements. Sets, dependent on the destination are completed with additional assembling elements.