25
FULL FEATURED AND AFFORDABLE EASY-TO-OPERATE Vibration pen with: Overall vibration measurement and Built-in FFT Bearing condition monitoring based on high frequency enveloping Store up to 500 points (LF waveforms or envelope waveforms) Route and off-route data acquisition PC connection via USB for detailed analysis EASY AND QUICK OPERATION Pocket size and light weight, built-in sensor and a handy design make this data collector always within reach, ready to measure vibration and control machine condition. Contrast graphic display with backlight and built-in FFT are designed for easy on-site condition monitoring and data analysis. Auto shutdown feature significantly increases battery lifetime. STD-500 Vibration Data Collector TECHNEKON | 2

Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

FULL FEATURED AND AFFORDABLE

EASY-TO-OPERATE

Vibration pen with:

Overall vibration measurement and Built-in FFT

Bearing condition monitoring based on high frequency enveloping

Store up to 500 points (LF waveforms or envelope waveforms)

Route and off-route data acquisition

PC connection via USB for detailed analysis

EASY AND QUICK OPERATION

Pocket size and light weight, built-in sensor and a handy design

make this data collector always within reach, ready to measure

vibration and control machine condition. Contrast graphic display

with backlight and built-in FFT are designed for easy on-site

condition monitoring and data analysis.

Auto shutdown feature significantly increases battery lifetime.

STD-500 Vibration Data Collector

TECHNEKON | 2

Page 2: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

TECHNEKON | 3

MULTIFUNCTIONAL

From quick on-site analysis to the delailed data processing

on your PC including spectrum analysis, trends creation,

detection location and severity of faults: imbalance,

misalignment, bed belt, bearing failure, soft foundation

and maintaining machinary condition database.

ROUTE AND OFF-ROUTE USABILITY

Uploading routes from Vibrodesigner Analysis Software

facilitates both data acquisition and creating of a unified

repository of diagnostics data by further automatic

downloading data onto your computer.

Page 3: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

TECHNEKON | 4

EASY TO USE

Only two buttons and intuitive menu make operation simple and

convenient:

point and press ENTER button

message is displayed on the LCD. The measured value is

shown, and collected wave is saved in the memory.

keyboard

display

tip

USB port

Power connector

Page 4: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

EXTRA FEATURES

measurement

Free firmware update available via USB

MEASUREMENT

Sensor built-in piezoelectric accelerometer

Low frequency measurement 10 to 1000 Hz (±1dB)

Enveloping measurement 5 kHz to 15 kHz

Sampling 8192

Internal FFT 3200 lines

MEMORY

DISPLAY

Type graphic, monochrome, with backlight

PC CONNECTION USB

POWER SUPPLY

Operating during up to 10 hours

Charging during up to 4 hours

ENVIRONMENT

Intrinsically save 1ExibIIBT3X

Case protection IP54

Tempreture -20 … +50 С

Humidity 90%

SIZE

WEIGHT 0,150 kg. (5,3 oz)

TECHNEKON | 5

Page 5: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Vibration Data Collector STD-500FEATURED AND AFFORDABLE EASY-TO-OPERATE

Page 6: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Vibration Data Collector STD-500

Page 7: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

STD-500 Accessories

Accessories:

•TD-500 Data Collector•USB cable•Charger•Case•Package

Page 8: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

STD-500 Interface

Vibration pen with:

•• Overall vibration measurement and Built-in FFT• Bearing condition monitoring based on high frequency enveloping• Store up to 500 points (LF waveforms or envelope waveforms)• Route and off-route data acquisition• PC connection via USB for detailed analysis

Page 9: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Physical and ElectricalSpecifications

Frequency range, Hz 10–1000

Enveloping measurement 5 kHz to 15 kHz

Vibration velocity RMS limits, mm/s 0.5-70

Measurement units Acceleration, Velocity, Displacement (P-P, Peak, RMS)

Sampling 8192Bandpass flatness, dB less than 1

Operating temperature, ° -20…+50Operating humidity (+35° ) 90%

Case dimensions, mm 186 35 21Weight, grams less than 150

Continuous use after complete charging, hours up to 10

Page 10: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Quick Start

1. Press the right button ( ) on the STD-500 front panel.The data collector is switched on. The main menu is displayed on the left of the LCD screen.2. To perform measurements, use the right button ( ) to navigate to theMEAS. iitem.3. Press the left button.The Measurement menu is displayed. The machine single-line menu is highlighted.4. Use the right button to select the machine you need.5. When selected, press the left button.The measurement point single-line menu is highlighted.

Page 11: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Quick Start

6. Use the right button to select the point you need.7. To start data acquisition, attach your data collector perpendicularly to the needed pointand press the left button.When finished, the Measurement is completed message is displayed on the LCD. The new data is recorded instead of old data.8. Press both buttons simultaneously.You are returned to the main menu.9. To analyze the collected data, use the right button to navigate to the ANALYS itemand then press the left button.10. Press the left button twice and view the collected data.

Page 12: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Main menu

Page 13: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Data Collection Mode

Data collection is performed from the main program menu.

Main menu

Data collection is carried out through the predefined route or in off-route points. Routes are uploaded into the STD-500 by means of Vibrodesigner-Expert and contain machines and machine points.A machine menu displays machine names of the uploaded routes. For off-route points, you can see “OFF-ROUTE” in the machine menus.A machine point menu displays the points in the following format: <NNN XXY NAME>, where NNN – the number of a point in the route, XX – the point number on a machine. Y – a measurement direction, NAME – a point name. Off-route points are displayed as <Point name NNN>, where NNN is the number of an off-route point.A machine is selected in the single-line machine menu. Pressing the left button results in switching to the machine point selection.

Page 14: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Data Collection Mode

Pressing the left button in the selected point results in either low-frequency measurement, or high-frequency envelope measurement, or in switching to the Analysis mode. To change the mode, press both the left and right buttons simultaneously to go back to the machinemenu, and then press both buttons again to go back to the main menu.In the main menu, you can select the following actions:· MEAS. – switch to the low-frequency signal measurement· MEAS. E – switch to the high-frequency measurement of the signal envelope· ANALYS – switch to the Analysis mode of the selected point.Depending on what parameters were used during the route point uploading, whether the low-frequency or high-frequency measurement is performed. So, you will see eitherMEAS or MEAS E in the lower left corner of the screen.

Main menu

Page 15: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Watch mode

In the Watch mode, the STD-500 collects vibration data and calculates an integral parameter without saving results in the device memory. To switch to the Watch mode, go to the main menu and select the Watch item.The Watch menu includes the following items:· MEAS – switch to the low-frequency signal measurement· MEAS E – switch to the high-frequency measurement of the signal envelope· ANALYS – switch to the Analysis mode of the measure.· UNITS – switch to the single-line menu to select measurement units for the low frequency measures. You cannot change measurement units for high-frequencysignals.

Main menu

Page 16: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Analysis ModeThe Analysis mode is designed to enable you to assess the measured data numerically and qualitatively. You can switch to the Analysis mode either from the main menu or from the Watch mode by selecting the ANALYS item.The screen in the Analysis mode is shown in the picture below.

You need first to specify a button mode, that is, which actions will be performed on pressing the buttons in the Analysis mode. You can choose one of the options listed below.

Button mode Description

<> Move the cursor along the X axis

Scl. Enlarge/shrink the X-axis view range

Scl.Y Enlarge/shrink the Y-axis view range

Units Change the graph measurement unit

Main menu

Page 17: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Options Menu

The Options menu commands are used to perform system operations, such as changing internal time and resetting ROM. The Options menu screens are shown in the picture below.

Main menu

Page 18: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Command DescriptionBacklight on Switching on/off highlighting

Set date and time Change internal date and time

Delete route Remove a route from the data collector memory

Del. Off-rt. Points Remove all off-route points from the data collector memory

Erase memory Reset a data collector ROM. This command is availableonly if the Memory error occurred

Accel <parameter> <meas units> Settings of the acceleration parameterVelocity <parameter> <meas units> Settings of the velocity parameter

Displ. <parameter> <meas units> Settings of the displacement parameter

Frequency <meas units> Settings of measurement unit for the frequency to be displayed

Options Menu

Main menu

Page 19: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

HF Spectrum Measurement Mode

To switch to the HF spectrum measurement mode, select HF SP. in the device main menu.First, the following message is displayed: “Measure HF spectrum? Yes/No”. Whenconfirmed, acceleration spectrum is measured in the 250-15000 Hz range, and the device is automatically switched to the Analysis mode.

Main menu

Page 20: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Communication with ComputerUse a standard USB cable to connect a STD-500 data collector to your workstation. When connected, the following message appears on the LCD screen: Connected to PC.When working with your data collector, you can use additional Vibrodesignersoftware.

Main menu

Page 21: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Communication with ComputerCreate inspection routes and load them into the data collector

Main menu

Page 22: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Communication with ComputerLoad collected data to a software database

Main menu

Page 23: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Communication with ComputerProcess and analyze collected data

Trends

Main menu

Page 24: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Setting

Communication with ComputerProcess and analyze collected data

Signals

Main menu

Page 25: Technekon-STD-500 - ESS POWER hanneld... · A machine point menu displays the points in the following format: , where NNN – the number of a point in the route,

Communication with ComputerProcess and analyze collected data

Signals

Main menu First slide