2
Route the pass-through cable up to the top of the dashboard.(3) BEFORE YOU START: make sure you have the following: Ensure the engine is shut off. 1. ND2 device 2. Diagnostic pass-through cable 3. Velcro tape TECH SPECS & INSTALLATION 1 Unmount the diagnostic plug from the vehicle panel. 4 Locate the diagnostic port on the vehicle. 2 Attach the pass-through cable directly to the diagnostic plug. Secure the connection into position by turning the lock ring clockwise. 5 6 Insert the unused side of the pass- through cable into the plug port on the panel. (2) 7 Attach the end of the pass-through cable to the ND2. 8 Re-install all removed panels. Ensure loose cables are safely stowed and hidden from view. (4) 9 10 Select and thoroughly clean the mounting location on the dash with an alcohol wipe (5) 11 Remove the required panels to allow access to the panel where the vehicle’s diagnostic plug is mounted. (1) 3 CONNECTED TRUCK PLATFORM DEVICE (Refer to footnotes (#) at the end of this document.)

TECH SPECS & INSTALLATION · 2021. 2. 25. · • J1939, J1587, ISO 15765 • PHYSICAL ND2 TO VEHICLE CONNECTION • Diagnostic Link Connector (DLC) pass-through design • 6-pin

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TECH SPECS & INSTALLATION · 2021. 2. 25. · • J1939, J1587, ISO 15765 • PHYSICAL ND2 TO VEHICLE CONNECTION • Diagnostic Link Connector (DLC) pass-through design • 6-pin

Route the pass-through cable up to the top of the dashboard.(3)

BEFORE YOU START: make sure you have the following:

Ensure the engine is shut off.

1. ND2 device 2. Diagnostic pass-through cable 3. Velcro tape

TECH SPECS & INSTALLATION

1

Unmount the diagnostic plug from the vehicle panel.

4

Locate the diagnostic port on the vehicle.

2

Attach the pass-through cable directly to the diagnostic plug.

Secure the connection into position by turning the lock ring clockwise.

5 6

Insert the unused side of the pass- through cable into the plug port on the panel. (2)

7

Attach the end of the pass-through cable to the ND2.

8

Re-install all removed panels. Ensure loose cables are safely stowed and hidden from view. (4)

9 10

Select and thoroughly clean the mounting location on the dash with an alcohol wipe (5)

11

Remove the required panels to allow access to the panel where the vehicle’s diagnostic plug is mounted. (1)

3

CONNECTED TRUCKPLATFORM DEVICE

(Refer to footnotes (#) at the end of this document.)

Page 2: TECH SPECS & INSTALLATION · 2021. 2. 25. · • J1939, J1587, ISO 15765 • PHYSICAL ND2 TO VEHICLE CONNECTION • Diagnostic Link Connector (DLC) pass-through design • 6-pin

PLEASE NOTE: This document is designed to be a general reference to installation of the ND2 device. Vehicle variations will influence the overall installation of the ND2, and all variations cannot be reasonably documented. (1) - For general illustration only. If applicable, refer to your vehicle's OEM service information on how to disassemble panels required to access the Diagnostic Link Connector (DLC). (2) - Mounting of the ND2 Passthrough cable may not be able to be installed exactly as shown. Your specific vehicle variant will dictate the manner in which the Passthrough cable is connected to the vehicle. Please contact Noregon Support if the Passthrough cable cannot be appropriately installed in your application. (3) Mounting the ND2 on the vehicle dashboard is highly recommended, where line of sight through the front windshield is desirable for best GPS signal acquisition. Mounting the ND2 in other locations may affect vehicle tracking and loss in functionality. (4) Reinstall all removed panels according to the appropriate OEM service information. (5) Cleaning the dashboard with an alcohol wipe is highly recommended for proper adhesion of the included Velcro tape. Be sure to choose an ND2 mounting location that does not impede with the driver's view or surroundings. Noregon is not responsible for vehicle damages, accidents, injuries or deaths resulting from installation of devices that impair the viewpoint of a vehicle operator.

FOOTNOTES:

15

VEHICLE PARAMETER & DATA REPORTING• SAE J1587/J1939 Sensor Data• CURRENTLY SUPPORTED: Cummins, International, Detroit Diesel• OEM Proprietary DTCs (where supported)• User configurable vehicle-specific parameter monitoring and reporting

ND2 TO VEHICLE CONNECTIVITY• SUPPORTED VEHICLE NETWORKS: • CAN 2.0b, 3 Channels at 125/250/500 kbps • Single Channel J1708 (multiplexed with CAN for J1939-2 connector requirements)• SUPPORTED COMMUNICATION PROTOCOLS • J1939, J1587, ISO 15765• PHYSICAL ND2 TO VEHICLE CONNECTION • Diagnostic Link Connector (DLC) pass-through design • 6-pin or 9-pin heavy-duty deutsch • 16-pin heavy-duty OBD-II

TECHNICAL SPECS & FEATURESDIAGNOSTIC TROUBLE CODE (DTC) REPORTING• Standard HD J1939 DTCs• Standard HD J1587 DTCs• OEM Proprietary DTCs (where supported)

ND2 DEVICE SPECS & FEATURES• Cellular LTE Cat. M1• GPS Enabled• Device Dimensions: 5 x 3 x 1.5 inches (12.7 x 7.6 x 3.8 cm)• Operating Temperature Range: -40°F to 185°F (-40°C to +85°C)• Supports 12V and 24V systems• Typical Operating Power Requirement: < 4 Watts• Maximum Operating Power Requirement: < 14 Watts• Over The Air (OTA) Firmware and Parameter Configuration Updates

WWW.NOREGON.COM SL-ND2-INSTALL-2021-01-022221 | ©Noregon. All Rights Reserved

Check TripVision UPTIME to see if your vehicle is listed. Click on the “Search By Vin” field and type in the vehicle VIN. Select the vehicle from the left hand column and verify the tabbed information for the vehicle is accurate.

If the auto-commissioning process fails, a non-green LED will be lit and a solid beep will sound. Open the ND2 application and select the commissioning button. Scan the QR code on the device and enter the vehicle’s VIN. A success message will be displayed that commissioning is complete.

1514

Attach the Velcro strips together, then apply one side of the Velcro to the ND2. Remove the remaining backing of the velcro and mount the device securely to the dash by pressing the two together with light downward force to adhere to the cleaned location.

12

Turn the key to the “Key On/Engine Run” position to begin the automated commissioning process. When the install process completes, the green light will illuminate and a tone will sound intermittently. Turn the key to the “Off” position to stop the intermittent beeping and complete the auto-commissioning process.

13

EXPERIENCING ISSUES? Contact TripVision Support: (855) 889-5776

Please refer to the chart below to determine the status light of your device:

Upon connection, the LED will illuminate yellow until cellular connection is made. This process typically completes in 10-60 seconds, but can take up to 5 minutes.

The ND2 will check for bus activity every 3 seconds and will illuminate red if connection cannot be made. If during this time the cellular connection is lost, the device will revert back to illuminate purple until cellular connection is re-established. If the problem persists, try disconnecting the passthrough cable from the ND2, wait ten seconds, then reconnect the passthrough cable back into the port.

The device will illuminate green when the ND2 has made a successful connection and represents the device being online and capable of transmitting data.

CONFIRMING DEVICE CONNECTION:

YELLOW

RED

GREEN